Military Engineer Services Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Nov 2024
Closing Soon29 Nov 2024
Tender Amount₹ 32,97,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Labour only to attend complaints of building security lights, Street lights, hanger lights, focus lights and flood lights of any capacity and type with the help of skilled electrician and helper and replacement of defective wires, rectifying loose connections, repair of cable junction box, replacement of LED drivers, surge arresters etc all as specified and as directed by Engineer-in-Charge. Note: (i) All complaints must be attended and rectified within 12 hrs from the time of information on regular interval or requirement basis. (ii) All the spares such as cables, cable junction box, street light brackets, LED street lights and any other connected accessories shall be measured and paid under relevant item separately. (iii) Repair and replacement of all kind as mentioned above in each pole shall be considered as one job at one time. (iv) safety equipments, ladder and vehicle shall be provided by the contractor at his own cost. (v) Record of complaints shall be maintained in a neat long register by the contractor and shall be put up to Engineer in charge and site executive for record before payment.

158

-

-

... More
Supply and fixing in replacement security/street light bracket 1.5 Mtr long made out of "Medium grade" GI pipe of size 32/40 mm dia including necessary bending / welding drilling of holes etc and mounting/fixing on poles / walls etc with and including FI clamps of size 40mm x 6mm and suitable length with necessary nuts, bolts and washers complete all as specified and directed.

50

-

-

... More
S&F in repair PVC insulated twin core cable 6 Sq mm with solid aluminium conductor cable complete all as specified and directed.

200

-

-

... More
Supply and fixing in repairs new generation IP 65 protected LED 40 Watts Gate Light, energy saving environmental friendly, long lige aesthetically designed with good indirect symmetrical light distribution, die cast aluminium landscape lumination with high power COBLED as light source complete all as specified and directed.

6

-

-

... More
S&F in repairs LED 10 Watts, Garden Light Inverted Pyramid Tripod Type with IP 65 protection, including nuts, bolts and other accessories for fixing complete all as specified and directed.

10

-

-

... More
S&F in repairs LED 10 Watts, Bamboo type LED bollard with IP 65 protection, including nuts, bolts and other accessories for fixing complete all as specified and directed.

6

-

-

... More
Supply, laying, jointing and commissioning in replacement LT underground cables XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multistranded aluminium conductors, 1100 volts grade cross sectional area 16 Sqmm 4 core including taking down unserviceable cable, laid in trenches complete all as specified and directed.

192

-

-

... More
Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part -1 of size 63mm outer dia and 50 mm inner dia complete all as specified and as directed.

360

-

-

... More
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil) for laying of cables, GI pipe or filling of earth resistance enhance compound and getting out including levelling of bottom surface to required level complete all as specified and directed

97.2

-

-

... More
Returning filling in including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and as directed.

96.07

-

-

... More
Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.

1.12

-

-

... More
S&F in repair MCB TPN, 415 Volts, AC 50 Hz 63 Amps, 10 KA, 'B' curve complete all as specified and directed.

5

-

-

... More
S&F in repair MCB SPN, 230 Volts, AC 50 Hz 63 Amps, 10 KA, 'B' curve complete all as specified and directed.

5

-

-

... More
S&F in repair MCB SP, 415 Volts, AC 50 Hz 10 Amps, 10 KA, 'B' curve complete all as specified and directed.

10

-

-

... More
M&L for earthing complete with Galvanised steel earth plate electrode of size 600mmx600mmx6mm, buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth plate not less than 1.5 Mtrs deep below normal ground level, connected to GI earth strip of size 32x6 mm by means of brazing and connected to earthing test point / distribution board/equipments or any other indicated situation by means of brazing all as shown in electrical plate No.3 of SSR Part I (2009) and testing on completion including necessary excavation and earth work in any type of soil, returning filling, removing of soil. GI medium grade pipe 20 mm dia 1.5 mtr long with funnel wire mesh as watering pipe, and GI medium GI medium grade pipe 32mm dia as earth lead protection pipe. Earth pit chamber made of PCC 1:2:4 type B1 using 20mm graded stone aggregate including 40mm thick chamber cover made of 1:2:4 type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 100 c/c on both ways precast chamber cover with lifting handle 16mm dia round bars including charcoal and common salt in alternate layer of 15cm thick covering all faces of earth electrode plate, including taking down old one, complete all as specified and directed. (Note :- (i) The rates quoted for the complete earthing shall deemed to include the cost of GI wire 4.00 mm dia and GI medium grade protection pipe upto 7.5 Mtrs. (ii) GI earth strip and GI medium grade protection pipe beyond 7.5 Mtrs length shall be measured and paid separately. (iii) Fresh red soil required to be re-filled and existing calcium carbonate skeleton mixed soil to be removed from site.

5

-

-

... More
S&F GI strip 32 x 6.0 mm with saddles and fixing screws on porcelain insulator/ spacer fixed at every 1 mtr length for extension, re-routing an re-alignment etc of earthing strip on roof/wall and joining the same with existing/New earth test point complete all as specified and directed by Engr-in-Charge.

70

-

-

... More
M&L for earthing complete with Copper earth plate electrode of size 600mmx600mmx3.15mm, buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth plate not less than 1.5 Mtrs deep below normal ground level, connected to copper earth strip of size 20x3 mm dia by means of brazing and connected to earthing test point / distribution board/equipments or any other indicated situation by means of brazing all as shown in electrical plate No.3 of SSR Part I (2009) and testing on completion including necessary excavation and earth work in any type of soil, returning filling, removing of soil. GI medium grade pipe 20 mm dia 1.5 mtr long with funnel and wire mesh as watering pipe, and GI medium grade pipe 40mm dia as earth lead protection pipe. Earth pit chamber made of PCC 1:2:4 type B1 using 20mm graded stone aggregate including 40mm thick chamber cover made of 1:2:4 type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 100 c/c on both ways precast chamber cover with lifting handle 16mm dia round bars including charcoal and common salt in alternate layer of 15cm thick covering all faces of earth electrode plate, including taking down old one, complete all as specified and directed. ((Note :- (i) The rates quoted for the complete earthing shall deemed to include the cost of GI wire 4.00 mm dia and GI medium grade protection pipe upto 7.5 Mtrs. (ii) GI earth strip and GI medium grade protection pipe beyond 7.5 Mtrs length shall be measured and paid separately. (iii) Fresh red soil required to be re-filled and existing calcium carbonate skeleton mixed soil to be removed from site.

4

-

-

... More
S&F copper earth strip 20 x 3.15 mm with saddles and fixing screws on porcelain insulator/ spacer fixed at every 1 mtr length for extension, re-routing an re-alignment etc of earthing strip on roof/wall and joining the same with existing/New earth test point including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
M&L in repairs for air termination, single pointed aluminium rod, 12mm dia and 300mm long including necessary fixing arrangement using clamp, nuts and bolts after taking down old unserviceable termination rod complete all as specified and directed.

12

-

-

... More
M&L in repairs for air termination, single pointed copper rod, 12mm dia and 300mm long including necessary fixing arrangement using clamp, nuts and bolts after taking down old unserviceable termination rod complete all as specified and directed.

12

-

-

... More
M&L for laying of HDPE pipe 32mm dia for protection of Earth strip from leakage current complete including taking out of earth strip from its original path complete all as specified and directed.

180

-

-

... More
M&L for digging earth pit of size 45cm x 45cm x 60cm into the adjacent of the high resistance GI/Copper earth pit, make a bore at the bottom of the earth pit of dia 200mm to a depth of 2 mtr, providing/inserting a GI pipe 40mm medium grade of length 2mtr into the hole/bore and fill the bore/hole with Back Filling Compound of Bentonite powder complete 3 X bag of 25Kg BFC including after mixing with water and making gel type compound including necessary GI/Copper strip connection of pipe to the existing earth strip of size 32 x 6mm GI/Copper strip by proper welding/soldering at both ends including returning, filling of loose soil complete all as specified and directed. Note: Joints at both ends of GI pipe and GI strip should be welded.

56

-

-

... More
Labour only for maintenance of conventional earth pit, repair and plastering of cracked earth pit & cover with cement mortar 1:4 ratio, pouring salt water solution of salt and water ratio 1:3) 5Kg : 15Ltr to bldg earthing, tightening of earth electrode, removing grass around the earth pit, repair/replacement of funnels, M&L of salt water of 5Kg common salt dissolved in 15 ltr water all as specified and as directed by Engineer-in-Charge. Note: (i) Location for repairing of earth pit chamber and earth pit covers shall be as per the direction of Engineer-in-Charge. (ii) All the maint works/replacement of parts are independent to each other except salt water solution.

115

-

-

... More
S & F test point terminal block inside the box which made out of gun metal or phosphorous bronze of size 75mm X 75mm X 25 mm, duly painted with 2 coats of synthetic enamel paint powder coated after applying 2 coat of primer over it, drilled and screwed including 3 Nos 8mm dia 25 mm long hex Head screw including thermoplastic weather proof terminal empty box for fixing the terminal block complete all as specified and directed.

9

-

-

... More
S&F in repairs LED street light fitting 45 watt with efficacy 110 lm/W, Wide voltage operating range of 140 V - 270 Volts & Wide temperature operating range: -10 °C to +50 °C, with best in class design & robust heat sink for better heat dissipation, electronic driver unit and IP 66 protection, IK & Surge Protection including necessary mounting bolts, nuts and washers including taking down u/s fitting complete all as specified and as directed.

95

-

-

... More
S&F in repair LED flood light 200 Watt ( 19800 System Lumens ) with efficacy 110 lm/W, Wide voltage operating range of 140 V - 270 Volts & Wide temperature operating range: -10 °C to +50 °C & Surge Protection Upto 10 kV, suitable for fixing on high mast pole, energy saving, environment friendly, long life, die-cast aluminium body with highly efficient LEDs as light source, including electronic drivers and IP 66 protection, all fixing arrangement like nuts, bolts, washers or cross arms if required, including taking down old light, complete all as specified and directed.

5

-

-

... More
S&F in repair LED flood light 50 Watt ( 5000 System Lumens ) with efficacy 105 lm/W, Wide voltage operating range of 140 V - 270 Volts & Wide temperature operating range: -10 °C to +50 °C, IP 66 protection, energy saving, environment friendly, long life, die-cast aluminium body with highly efficient LEDs as light source, including electronic drivers and all fixing arrangement like nuts, bolts, washers or cross arms if required, including taking down old light, complete all as specified and directed.

10

-

-

... More
S&F in repairs LED street light fitting 70 watt ( 7500 System Lumens ) with efficacy 110 lm/W, Wide voltage operating range of 140 V - 270 Volts & Wide temperature operating range: -10 °C to +50 °C, made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass including electronic driver and IP 66 protection, impact resistance of IK07 & Surge Protection including necessary mounting bolts, nuts and washers including taking down u/s fitting complete all as specified and as directed.

15

-

-

... More
S&F in repairs LED street light fitting 150 watt ( 11000 System Lumens ) with efficacy 110 lm/W, Wide voltage operating range of 140 V - 270 Volts & Wide temperature operating range: -10 °C to +50 °C, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having top opening separate driver compartment including electronic driver and IP 66 protection, impact resistance of IK08 & Surge Protection including necessary mounting bolts, nuts and washers including taking down u/s fitting complete all as specified and as directed.

15

-

-

... More
Supply and fixing in repairs new generation IP 65 protected LED 40 Watts post top energy saving environmental friendly, IP 65 protection, long lige aesthetically designed with good indirect symmetrical light distribution, die cast aluminium landscape lumination with high power COBLED as light source.

2

-

-

... More
Supply and fixing Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (9.00 metres long), including suitable single arm for street light fitting, and dismantling the existing old broken concrete pole with footing complete all as specified and as directed.

5

-

-

... More
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate with smooth finished without using extra cement above ground level complete all as specified and directed.

1.5

-

-

... More
S&F in repairs PVC Conduit pipe of size 20mm including elbow, long bends, saddle clamps, nuts, bolts and washers complete all as specified and directed.

50

-

-

... More
S&F in repair PVC insulated twin core cable 6 Sq mm with solid aluminium conductor cable complete all as specified and directed.

150

-

-

... More
Supply & fixing in replacement KIOSK Box (Junction box) weather proof made up of one piece mounted on SMC base and door pole mounted double door hinged (R) of size (240x130x95)mm complete all as directed.

20

-

-

... More
Supply, laying, jointing and commissioning in replacement LT underground cables XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multistranded aluminium conductors, 1100 volts grade cross sectional area 25 Sqmm 4 core including taking down unserviceable cable, laid in trenches complete all as specified and directed.

192

-

-

... More
M & L for replacement of unserviceable LED strip of gate light/round gate light, Garden light. LED Strip 24 watts 3000K per meter, cool white light, voltage operating range of 140 V - 270 Volts & Wide temperature operating range: -10 °C to +50 °C, 80lm/w with driver input supply 140 to 270 volt output supply 12 volt DC (24W 2A 12V DC) complete all as specified and directed by Engr-in-Charge. Note : 1 meter strip led and 1 x driver considering in each Job including necessary Soldering work.

25

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.