Military Engineer Services Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date8 Feb 2024
Closing DateCancelled
Tender Amount₹ 39,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying, laying, connecting, testing and commissioning of 3 core, 95 Sqmm, 11000 Volts grade (Earthed) XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor laid in trenches / under ground / wall / surface / tunnel /duct including taking out unserviceable burnt out cable complete all as specified and as directed.

300

-

-

... More
S & F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP protection of IP-67 having outer dia 120 mm and inner dia of 103 mm with necessary couplers, bends etc., for protection of LT cable all as specified and as directed.

285

-

-

... More
M & L for road / PCC cutting for laying of HT UG cable /GI pipe etc and making good the disturbed surface complete all as specified and as directed.

18

-

-

... More
Supply and laying GI tubing 100 mm bore, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and as directed.

18

-

-

... More
M & L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in lean concrete in foundation of poles, stay assembly, etc., including formwork (as/if required), complete all as specified and as directed.

4.32

-

-

... More
M & L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping of poles etc., and finishing the concrete surfaces fair and even including necessary formwork required at site(s), complete all as specified and as directed.

0.55

-

-

... More
Supply & erecting steel tubular swaged pole type 410-SP-55 (11.0 metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws including applying two coats of black bituminous paint internally and externally from bottom end of pole upto PCC coping and applying with two coats of aluminium painting over a coat of aluminium primer (externally from top of coping) including writing MES Pole No. with synthetic enamel paint (first grade/quality), complete all as specified and as directed. Note : Earthwork, cement concrete, etc. will be measured and paid under appropriate items.

6

-

-

... More
Supply & erecting steel tubular swaged pole type 410-SP-31 (9.0 metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws including applying two coats of black bituminous paint internally and externally from bottom end of pole upto PCC coping and applying with two coats of aluminium painting over a coat of aluminium primer (externally from top of coping) including writing MES Pole No. with synthetic enamel paint (first grade/quality), complete all as specified and as directed. Note : Earthwork, cement concrete, etc. will be measured and paid under appropriate Items.

6

-

-

... More
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated/ directed and inclusive of one coat of aluminium primer one under coat and one finishing coat of aluminium paint, complete all as specified and as directed.

2

-

-

... More
M & L for Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible sags and providing jumper, etc., fixing on electric poles and binding to insulators with aluminium binding wire as in OH conductors including stringing, tightening, etc., complete all as specified and as directed. Note : Cost of binding wire is deemed to be included in the quoted unit rate.

0.25

-

-

... More
S & F insulator pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11 KV grade, complete all as specified and as directed.

3

-

-

... More
S & F disc type insulator porcelain, vitreous, 145mm high and 255mm dia ball and socket type white, brown or green insulator single disc assembly for tension with tension clamps for conductors working pressure 11 KV, complete all as specified and as directed.

3

-

-

... More
S & F expulsion fuse, single pole, channel type /drop out type suitable as per site requirement with working pressure 11 KV grade of capacity 50 to 100 Amps including taking down unserviceable fuses, complete all as specified and as directed.

3

-

-

... More
Dismantling and taking out existing DO fuse unit 3 pole 11 KV channel mounted complete including supply and fix for new DO fuse unit 3 pole 11 KV channel mounted complete set including mounting on post top insulators and other misc accessories for the satisfactory completion of job complete all as directed by Engr-in-Charge.

3

-

-

... More
S & F lightening arrestor non linear resistor type conforming to IS 3070 (part-3) 1993 complete, line discharge class-3, nominal discharge current 10KA (peak), 12KV rated system, voltage peak value high current implus of 4/10 micro sec. wave shape 100 KA (peak) assembly suitable for 11 KV ,long duration discharge class-II with insulation level 28/75 KV and mounted on hot dip galvanized steel structure including all clamps, nuts, bolts and washers and connecting to earth with 4 mm dia GI wire including removal of existing unserviceable one complete all as specified and as directed.

5

-

-

... More
S & F switch air break gang operated for 11 KV grade, triple pole vertically mounted on insulator and fitted on steel frame, current rating 200 Amps, mechanically operated mechanism from ground level consisting of operating rod of GI pipe 25mm bore (dia) ‘light grade’ of suitable length worked from ground level and with locking arrangement mild steel FI clamp 50 x 6mm including dismantling old unserviceable switch air break of any description complete all as specified and as directed.

2

-

-

... More
Dismantling and servicing of air break gang operated switches HT 11 KV 3 phase, any capacity ( 200/400 ) Amps vertical / horizontal mounted including insulators and operating mechanism for repair/replacement of broken / worn out components and insulators etc., with or without taking down from pole complete all as specified and directed. Note :- (a) Parts needed to be replaced shall be measured and paid seperately as 'supply only' against appropriate items of schedule. However labour component involved in replacement is included in unit rate quoted against this Item. The unit rate shall deemed to be included for handling of serviceable materials for reuse to site and as directed (b) Any minor repairs involved to make the GOD functional even if notified by Engineer-in-Charge shall be carried out by the Contractor without any extra cost to the Department.

10

-

-

... More
Supply only male contact/ moving contact blade suitable for air break gang operated switches, 11KV, complete all as specified and as directed.

3

-

-

... More
Supply only female contact/ fix contact jaw suitable for air break gang operated switches, 11KV, complete all as specified and as directed.

3

-

-

... More
Supply only tinned copper flexible jumper 200/400 Amps, suitable for air break gang operated switches, 11KV, complete all as specified and as directed.

3

-

-

... More
Supply only MS jumper carrier, suitable for air break gang operated switches, 11KV, complete all as specified and as directed.

3

-

-

... More
Supply only back connector plate, suitable for air break gang operated switches, 11KV, complete all as specified and as directed.

3

-

-

... More
M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15cm size all as specified and as directed.

10

-

-

... More
M & L for advance maintenance free G.I. SAFE EARTHING electrode with pipe of not less than 50 mm outer dia (thickness not less than 2.5mm) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32x 6 mm (upto 7.5 m). The GI electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg back fill compound to provide maximum contact between the electrode and back fill compound. Backfill compound should be eco-frendly and having RoHs certification, GI electrode shall be tested from CPRI. The earting pit should be covered with PCC (1:2:4 , type B-1) cover of 450 x 450 mm complete all as specified and as directed. Make: ASHLOK / INDELEC/JMV /TERCEL.

15

-

-

... More
M & L for maintenance of earthings of installations like cleaning of earth pits, treatment of earthing by pouring salt water, replacement of perished wire mesh, unserviceable funnel and repair works like patch works to the PCC chambers and RCC cover with CM(1:4) including painting of chamber from outside complete all as specified and as directed.

25

-

-

... More
M & L for stay assembly comprising of MS stay plate 6 mm thick and of size 300 x 300 mm and 20 mm dia MS stay rod, 2150 mm long including thimbles GI stay strand 7/3.15 mm dia of required length complete all as shown on electrical plate No.1 on page No.495 of MES Sch SSR Part-I 2009 including necessary excavation PCC (1:3:6) type C-2 (using 40mm graded stone aggregate), loop insulator as specified in SI and including taking down old unserviceable one complete all as directed by Engr-in-Charge.

5

-

-

... More
M & L for attending of HT 11 kV break downs, checking faults and renewal of burnt fuse wires in 11kV installations with necessary tools i.e 11kv discharge rod, meggers, gloves etc complete all as directed by Engr-in-Charge. Note: (i) T & P shall be provided by the contractor free of cost, and the rate quoted shall deemed to include this aspect. (ii) One skilled electrician and helper shall be provided while attending this job free of cost, and the rate quoted shall deemed to include this aspect. (iii) Proper isolation and safety guidelines shall be followed by the contractor, in case of any eventuality the contractor is fully responsible.

5

-

-

... More
M & L for cable jointing kit for 11 KV (earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm including taking out old unserviceable one complete all as directed by Engr-in-Charge.

2

-

-

... More
M & L for cable jointing kit for 11 KV (earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm including taking out old unserviceable one complete all as specified and as directed. Note: Earth work shall be measured and paid separately.

6

-

-

... More
M & L for disconnection of all primary/ secondary connections of the defective transformer rating up to 320 kVA outdoor / indoor type, any make, taking down / out from plinth / pole / platform with the help of suitable crane and transporting the same carefully to workshop for repair and bringing back and testing, installation & commissioning in its original existing position by making all neccessary connections complete all as directed by Engr-in-Charge. Note :- Quoted rate shall be inclusive of crane and transporting charges to and fro to Port Blair in this Job.

1

-

-

... More
M & L for opening top cover of transformer taking out complete oil and keeping in clean and dry container, taking out core & winding from the body, remove the sludge from tank complete and segregation of HT/LT leg coil from transformer including job assembling of jointing the connections of HT/LT coil in core assembling complete insulation works, setting of core, making new connections (as per existing connections), proper alignment of job including keeping in oven chamber as per IS specification of respective transformer capacity to remove the moisture as well as fixing of upper yoke lamination, checking, tightening, nuts, bolts, washers and all types of gasket (bushing and tank) etc and welding if any leakage found in body or fins, making good deficient item if any, testing the jobs with megger for proper results including two coats of anti corrosive paint after cleaning inside transformer tanks and two coats of outside painting including writing KVA capacity, repairs of body by means of welding, jointing if required complete for capacity up to 320 KVA with complete testing and commissioning all as directed by Engr-in-Charge.

1

-

-

... More
M & L for making primary /secondary coil with insulating copper wire of required gauge craft paper cotton tape HT/LT insulation as per specification of old existing transformer including making of coil as required of various capacity of transformer complete all as directed by Engr-in-Charge.

100

-

-

... More
M & L for reconditioning of over heated HT/ LT coil of transformer up to 320 KVA after removing all old insulation any type and re-insulation as required and remaking of LT coil complete all as directed by Engr-in-Charge.

100

-

-

... More
M & L for opening of the 11 KV / 0.433 KV distribution transformer rating up to 320 KVA by removing the inspection cover / top cover, decanning of the transformer oil up to the required level, check leaked cork seal (if any), check the unserviceable insulators & LT/HT bush (if any) complete from the shell and making connections of LT/HT bush, insulators & cork seals to avoid leakage and refilling oil back to existing postion into the transformer complete testing & commissioning complete all as directed by Engr-in-Charge. Note: Spares shall be measured and paid separately under relevant items.

2

-

-

... More
S & F of HT bushing rod / studs for any make of transformer rating up to 320 kVA mounted on pole/plinth, made of brass of suitable size with nut and washers, insulator and fittings etc as per size and shape of original complete including taking down old unserviceable one complete all as directed by Engr-in-Charge.

2

-

-

... More
S & F of LT bushing rod / studs for any make of transformer rating up to 320 kVA mounted on pole/plinth, made of brass of suitable size with nut and washers, insulator and fittings etc as per size and shape of original complete including taking down old unserviceable one complete all as directed by Engr-in-Charge.

2

-

-

... More
S & F gasket set (cork sheet) for any make of transformer rating upto 320 KVA for top of transformer or conservator tank after decanning the required level of oil including taking down old unserviceable one complete all as directed by Engr -in-Charge.

2

-

-

... More
M & L for replacement of air breather with filled silica gel suitable for any make of transformer rating up to 320 KVA mounted on plinth/pole including taking out old unserviceable one complete all as directed by Engr-in-Charge.

10

-

-

... More
M & L for dehydration including filtration cleaning of transformer oil in transformer indoor/ outdoor type by centrifusion / machine having minimum capacity 1000 to 30000 ltrs/ hrs including testing insulation and viscosity of oil before and after dehydration complete all as directed by Engr-in-Charge.

1700

-

-

... More
M & L for shifting of any make of transformer rating up to 320 KVA mounted on plinth /pole from existing location to new location and existing transformer vice versa, including removing and reconnections of HT/LT side, jumper / cable connection, control cable connection of both transformers including testing and commissioning complete all as directed by Engr-in-Charge. Note:- The rate quoted is deemed to be inclusive of necessary crane / vehicle charges for shifting and installation of the transformer.

1

-

-

... More
M & L for cleaning /painting the HT poles of OH lines and HT 11 mtr steel tubular poles poles / four poles / two poles structure complete with cross arms any height and of any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt / dust /rust carefully and applying two coats of synthetic aluminium paint including marking and colour washing of pole coping details for Two poles with cross Arms complete all as specified and as directed.

2

-

-

... More
Description all as per Item No 44 above but HT 11mtrs single pole complete all as specified and as directed.

5

-

-

... More
M & L for cleaning / painting the HT poles of OH lines and HT 11 mtr PCC / RCC poles / four poles / two poles structure complete with cross arms any height and of any description thoroughly with necessary cleaning agent including scrapping up of old paint dirt / dust / rust carefully and applying two coats of synthetic weather proof distemper paint and two coats of aluminium paint for channels and other metallic parts including marking and colour washing of pole coping details for two poles with cross arms complete all as specified and as directed.

5

-

-

... More
Description all as per Item No 45 above but four poles with cross arms complete all as specified and as directed.

2

-

-

... More
Description all as per Item No 45 above but HT 11mtrs single pole complete all as specified and as directed.

6

-

-

... More
M & L for spray painting of upto 320 KVA transformer pole mounted / plinth mounted at site and applying two coats of synthetic enameled smoke grey paint after removing all dust & rust and paint shall confirm to IS 2032 including marking or transformer capacity with stencil letter with black or white paint, font and size of letter shall be as directed by Engr-in-Charge.

10

-

-

... More
M & L for meggering with 1000v / 2500v / 5000v hand operated megger machine of HT overhead conductor between span to span/ two pole structure/ four pole structure, any type insulator with complete diconnection & reconnection of jumper for checking of fault and rectification for any size any place after disconnection of AB switch complete all as directed by Engr-in-Charge.

5

-

-

... More
S & F cable route indicator, made out of 150mm dia and 6mm thick MS plate, duly embossed with description as "HT UG cable" fitted to 0.5m long angle iron of size 25mm x 25mm x 3mm with bolts and nuts and painting all over with two coats of aluminium paint over one coat of red oxide primer and embedded in PCC (1:3:6) type C-1 block of size 200mm x 200mm x 200mm and planted in cable trench all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply & filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacement up to desired level of transformer oil capacity complete all as specified and as directed. Note: Dielectric strength of oil should not be less than 42 KV/cm Make : Gulf / Power Oil/ ServoElectra/ HP transformer Oil

100

-

-

... More
S & F for electric shock treatment coloured chart of English and Hindi languages of size 2' x 3' PVC transparent sheet and back side with hardboard cover of 3 mm thick including suitable hanging arrangement complete all as specified and as directed.

4

-

-

... More
Supplying and laying stone aggregate of size 40mm to 60mm properly in transformer yard upto 100mm depth all as specified and as directed by Engr-in-Charge.

20

-

-

... More
Supply only Rubber Mat of size 2m x 1m x 25mm for electrical insulation suitable for upto 11KV electric supply all as specified and as directed by Engr-in-Charge.

16

-

-

... More
M & L for cutting anxious green growth /vegetation growth for cleaning out the area around transformer installations and two/four pole structure at ground level by cutting out root, unwanted plants, bushes and removal of the same by surface excavation not exc 30cm deep avg 15 cm deep in any type of soil complete all as specified and as directed.

1000

-

-

... More
REPAIR/RENEWAL OF SPARES AND SERVICING OF STANDBY DIESEL GENSETS AT VARIOUS LOCATIONS OF INS BAAZ, ARMY LAND, 3U DET & COAST GUARD Periodical maintenance of DG set of 140 KVA capacity as per manufacturer recommendation including painting, installed at various location complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
Description all as per Item No 54 above but DG set of 125 KVA capacity complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Description all as per Item No 54 above but DG set of 82.5 KVA capacity complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Description all as per Item No 54 above but DG set of 62.5 KVA capacity complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Description all as per Item No 54 above but DG set of 50 KVA capacity complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Description all as per Item No 54 above but DG set of 25 KVA capacity complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Description all as per Item No 54 above but DG set of 20 KVA capacity complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Note:- Item Nos. 54 to 54.6 (a) Checking the fan belt, fuel, oil filter, air filter, FIP performance, FIP oil level, tappet clearance, adjustment of fuel pump timing, tighting of base bolt nuts, battery distilled water level, vibration damper mounting, radiator, radiator hose, panel board cable connection tighting. (b) Service Engineer report from authorised dealer shall be submitted for every check about the performance and maintenance of DG sets (c) Highly skilled labours and tools for maintenance/checks repairs /replacement is deemed to be included in the rate quoated by the contractor (d) Replacement of spares, coolant, distilled water, engine oil, fuel/ oil/air filter shall be measured under relevant items & minor spares parts including door hinges are deemed to be included in the quoted rate. (e) Mechanic , Supervisor and Maintenance Engineer must be skilled and must have knowledge of maintenance of DG Sets and attending minor and major fault when it arise.

-

-

-

... More
Disconnecting, removing and dismantling radiator assembly from 20 KVA to 50 KVA capacity Genset and descaling the radiator thoroughly with suitable chemical solvent agent as approved by the Engineer-in-Charge, stopping of leakeage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enamelled paint etc re-installing and commissioning all as directed by Engr-in-Charge.

1

-

-

... More
Description all as per Item No 55 above but 62.5 KVA to 100 KVA capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
Description all as per Item No 55 above but 125 KVA to 140 KVA capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
Disconnecting the existing battery of capacity 12V 92/100 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable sulphuric acid from the battery, filling up with new sulphuric acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engr-in-Charge.

1

-

-

... More
Description all as per item No 56 above but of capacity 12V,180AH complete all as directed by Engr-in-Charge.

1

-

-

... More
M & L for replacing the worn out carbon brushes slip ring type in alternator of any capacity DG set including all necessary connected works all as directed by Engr-in-Charge.

5

-

-

... More
Draining out the existing diesel from the tank of 20 KVA to 50 KVA Capacity Genset , kept as side for repouring, taking out the complete fuel tank of any capacity from its position after disconnecting all the fuel lines, carryout cleaning work with solutions, removing the dust and foreign materials from the tank, drying the tank, blow with air painting and carry out recaliberation of diesel tank to the specified level including replacement of PVC level pipe, refix the tank in its original position, connecting all the removed fuel connections, refilling the kept diesel back to the tank carefully, remove air from the fuel connections, start the engine and test for satisfactory function all as directed by Engr-in-Charge.

2

-

-

... More
Description all as per Item No 58 above but 62.5 KVA to 100 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
Description all as per Item No 58 above but 125 KVA to 140 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
M & L for removing defective AVR from alternator and replacing with new AVR upto 100 KVA DG sets make as per existing all as specified and directed by Engr -in-Charge.

2

-

-

... More
Description all as per item No 59 above but Alternator capacity more than 100 KVA and upto 140 KVA capacity of make as per existing all as specified and directed by Engr -in-Charge.

1

-

-

... More
M & L for disconnecting electrical and mechanical connections of 20 KVA to 50 KVA Capacity Genset alternator, 415 volts, 50 HZ removing from foundations /diesel engine coupling and transporting private work shop, dismantling the alternator in parts and carrying out servicing , varnishing and applying the bactol on the exciter coils /winding with super varnish, heating the windings at appropriate temperature to achieve required insulation resistance without damaging the other parts, replacement of driving and non driving end bearings, cleaning, greasing, reassembling /installing /connecting and testing with megger for insulation resistance etc all as directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 60 above but 62.5 KVA to 100 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
Description all as per Item No 60 above but 125 KVA to 140 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
M & L for disconnecting electrical and mechanical connections of 20 KVA to 50 KVA Capacity Genset Alternatror, 415V, 50 HZ removing from foundation /diesel engine coupling and transporting to private work shop, dismantling the alternator in parts and removing the burn out copper winding coil carefully, cleaning slots and replacing the insulation paper and winding F class copper conductor winding wire of existing size/shape , glass sleeves of connecting leads, binding / tightening loose coils with binding clothes , varnishing and applying the bactol on the exciter coil/ winding with supper varnish, heating the windings at appropriate temperature to achieve required insulation resistance without damaging the other parts, replacement of driving and non-driving end bearings, cleaning, greasing, reassembling / installing /connecting and testing with megger for insulation resistance etc as directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 61 above but 62.5 KVA to 100 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
Description all as per Item No 61 above but 125 KVA to 140 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
M & L for replacing the old unserviceable battery lead with copper terminals approximately 2.5 mtr length including applying jelly over the battery pole and terminals all as directed by Engr-in-Charge.

10

-

-

... More
M & L for replacing the old unserviceable battery terminals ( Positive & Negative ) including brazing work and applying jelly over the battery pole and terminals all as directed by Engr-in-Charge.

5

-

-

... More
M & L for replacing the damaged/burn out battery terminal pole (positive / negative) 12 V DC battery and recosting lead as per the site requirement complete all as specified and directed by the Engr-in-Charge.

5

-

-

... More
S & F in replacement of the following spares during repairs :- (a) Oil filter capacity 1/2 litre with 'O' ring complete all as directed by Engr-in-Charge.

5

-

-

... More
(b) Oil filter capacity 1 litre with 'O' ring complete all as directed by Engr-in-Charge.

5

-

-

... More
(c) Diesel filter capacity 1/2 litre with 'O' ring ( Pre & Micro) complete all as directed by Engr-in-Charge.

4

-

-

... More
(d) Diesel filter capacity 1 litre with 'O' ring ( Pre & Micro) complete all as directed by Engr-in-Charge.

5

-

-

... More
(e) Sump/Crank case packing suitable for 20 KVA to 50 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
(f) Sump/Crank case packing suitable for 62.5 KVA to 100 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
(g) Sump/Crank case packing suitable for 125 KVA to 140 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
(h) Air filter suitable for 20 KVA to 50 KVA Capacity Genset complete all as directed by Engr-in-Charge.

3

-

-

... More
(j) Air filter suitable for 62.5 KVA to 100 KVA Capacity Genset complete all as directed by Engr-in-Charge.

2

-

-

... More
(k) Air filter suitable for 125 KVA to 140 KVA Capacity Genset complete all as directed by Engr-in-Charge.

4

-

-

... More
(l) Rocker arm packing kit suitable for 20 KVA to 50 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
(m) Rocker arm packing kit for 62.5 KVA to 100 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
(n) Rocker arm packing kit 125 KVA to 140 KVA Capacity Genset complete all as directed by Engr-in-Charge.

1

-

-

... More
(o) Engine Oill 20W-40 complete all as directed by Engr-in-Charge. Make : Castrol/BP

400

-

-

... More
(p) Radiator Coolant complete all as directed by Engr-in-Charge.

200

-

-

... More
(q) Distilled water with PVC container complete all as directed by Engr-in-Charge.

50

-

-

... More
(r) Electrolite with PVC container complete all as directed by Engr-in-Charge.

10

-

-

... More
(s) Bearing Grease complete all as directed by Engr-in-Charge.

20

-

-

... More
(t) Petroleum Jelly complete all as directed by Engr-in-Charge.

3

-

-

... More
(u) Cotton Waste complete all as directed by Engr-in-Charge.

5

-

-

... More
(v) Selector Switch as per sample complete all as directed by Engr-in-Charge.

3

-

-

... More
(w) Contactors complete all as directed by Engr-in-Charge.

2

-

-

... More
M & L for replacing the existing damaged /bulged radiator flexible rubber hose for 20 KVA to 50 KVA Capacity Genset installed at various installation and replaced with new radiator flexible hose with circular hose clips complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Description all as per Item No 66 above but 62.5 KVA to 100 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 66 above but 125 KVA to 140 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Taking down the existing worn out fanbelt (V Belt) for 20 KVA to 50 KVA Capacity Genset installed at various installation and replaced with new fan belt complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Description all as per Item No 67 above but 62.5 KVA to 100 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Description all as per Item No 67 above but 125 KVA to 140 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Taking down the existing unserviceable water pump assy for 20 KVA to 50 KVA Capacity Genset installed at various installation and replaced with new water pump assy complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 68 above but 62.5 KVA to 100 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 68 above but 125 KVA to 140 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Taking down the existing defective panel board indication lamp (RYB) from the panel and replaced with LED indicator lamp with holder complete all as specified and directed by the Engr-in-Charge

2

-

-

... More
Taking down the existing defective panel board Hours meter from the panel and replaced with Analog Hours meter complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Taking down the existing defective RPM meter along with cable and replaced with RPM meter complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Taking down the existing defective radiator cap from the radiator and replaced with new radiator cap complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Taking down the existing Volt meter / Ammeter / Frequency Meter from the panel board and replace with new digital Voltmeter/ Ammeter / Frequency Meter including necessary wiring and wiring material all as specified and directed by the Engr-in-Charge. Make: AE/MECO

3

-

-

... More
Taking down the existing unserviceable oil pump assy for 20 KVA to 50 KVA Capacity Genset installed at various installation and replaced with new oil pump assy complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 74 above but 62.5 KVA to 100 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 74 above but 125 KVA to 140 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Taking down the existing unserviceable panel board ON/OFF push button and replaced with new push button complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Taking down the existing defective oil pressure gauge from the panel and replaced with new oil pressure gauge along with metal flexible pipe complete as as specified and directed by the Engr-in-Charge. Make: AE/MECO

2

-

-

... More
Taking down the existing defective oil temperature gauge from the panel and replaced with oil temperature gauge along with connected links complete all as specified and directed by the Engr -in-Charge. Make: AE/MECO

2

-

-

... More
Taking down the existing defective injector and Fuel Injection Pump (FIP) for 20 KVA to 50 KVA Capacity Genset installed at various installation and replacement of work out spares like delivery valves, nozzles, bearings, fly weight, packing kit, and copper washer kit and recalibration of FIP and refixing in same position and testing of full load checking of pressure complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 78 above but 62.5 KVA to 100 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 78 above but 125 KVA to 140 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Taking down the existing defective DC Ammeter and volt meter from the panel and replaced with new combined DC Ammeter and Volt meter including necessary wiring and wiring material complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Taking down the existing defective self starter from Genset 12 V capacity installed at various installation and replacement of work out spares like Bendex drive, carbon brush, solenoid coil, Armature including rewinding stator, refixing in same position and testing complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per item No 80 above but 24V complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Taking down the existing defective unserviceable self starter from Genset 12 V capacity installed and replace with new self starter in same position and testing complete all as specified and directed by the Engr-in-Charge. Make: LUCAS/TVS or equivalent as per existing make.

1

-

-

... More
Description all as per item No 81 above but 24V complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Taking down the existing defective /damaged oil flexible (Metal mesh /rubber) hose and replaced with new oil flexible hose for 20 KVA to 50 KVA Capacity Genset including replacement of connector etc., complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 82 above but 62.5 KVA to 100 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 82 above but 125 KVA to 140 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
S & F Battery 12 V 180 AH for DG set complete all as specified and directed by Engr-in-Charge. Make : Amco / Kirloskar/ Exide/ Xpress / Amaraja

2

-

-

... More
S & F Battery 12 V 100/90 AH for DG set complete all as specified and directed by Engr-in-Charge. Make : Amco / Kirloskar/ Exide/ Xpress / Amaraja

2

-

-

... More
Taking down the existing defective water temperature gauge from the panel and replaced with water temperature gauge along with connected links complete all as specified and directed by the Engr-in-Charge.

2

-

-

... More
Taking down the existing defective / damaged radiator and replace with new radiator for 20 KVA to 50 KVA Capacity Genset including replacement of connector etc., complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 86 above but 62.5 KVA to 100 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Description all as per Item No 86 above but 125 KVA to 140 KVA Capacity Genset complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
S & F Battery Charger including all the connections as required to charge the battery single phase 50 Hz complete all as specified and as directed by Engr-in-Charge.

3

-

-

... More
M & L for overhauling of DG set upto 150 KVA such as works of engine piston, cylinder head, crank shaft, cam shaft, lathe works including replacement of bearing bush, turbo charger, connecting rod bolt, piston ring set, cylinder liner, intermediate ring, bush for injector etc and replacement of other worn out or damaged items as required all as specified and as directed by Engr-in-Charge.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.