Military Engineer Services Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date25 Jan 2024
Closing Date20 Feb 2024
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F Pin type, composite silicon rubber polymeric type insulator150mm height,150mm dia for 11000 volts grade, 5 kN with ECR glass rod, forged steel top and bottom, silicon rubber housing and weather sheds, including one galvanized mild steel spindle, galvanized iron washer, spring and one galvanized iron nut all as specified and as directed including taking down existing unserviceable insulator complete all as specified and as as directed by engineer in charge. [Make: GK Electricals/ BHEL/ Jayshree/ WS Industries/ Southern Insulators/ Mysore]/ Areva/ ABB

6

-

-

... More
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete including dismantling existing rusted/ unserviceable cross arms complete all as specified and as as directed by engineer in charge.

1

-

-

... More
S&F long rod insulator, composite silicon rubber polymeric type 290mm height, 100mm dia for 11000 volts grade, 45 kN with ECR glass rod, forged steel tongue and cleaves, silicon rubber housing and weather sheds all as specified and as directed including taking down existing unserviceable disc type insulator complete all as specified and as as directed by engineer in charge. [Make: GK Electricals/ BHEL/ Jayshree/ WS Industries/ Southern Insulators/ Mysore]

9

-

-

... More
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping of pole including use & waste of necessary form work including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as as directed by engineer in charge.

1

-

-

... More
M&L for plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete for pole walls underneath 2pole/4pole structure, feeder pillar boxes etc. complete all as specified and as as directed by engineer in charge.

1

-

-

... More
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized earth strip of 32X6mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including and protected by 40mm dia medium grade GI pipe, watering arrangement with PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of Schedule Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion complete all as specified and as as directed by engineer in charge.

6

-

-

... More
S&F GI earth strip of size 32x6mm laid in trench or fixed to wall/ pole with necessary clamps and nuts, bolts etc. including taking out unserviceable earthing strip complete all as specified and as as directed by engineer in charge.

45

-

-

... More
M&L for Earthing complete with copper earth plate electrode 60cm x 60cm x 31.5mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to copper earth strip of 20X3mm size by means of bolts, nuts, check nuts and washers of copper and connected from earth plate electrode to main switch board/ earthing test point including and protected by 40mm dia medium grade GI pipe, watering arrangement with PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of Schedule Part-I 2009 and connected to earthing test point and testing on completion complete all as specified and as as directed by engineer in charge.

3

-

-

... More
S&F copper earth strip of size 20x3mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, fixed with necessary clamps and nuts, bolts etc. including taking out unserviceable strip complete all as specified and as as directed by engineer in charge.

40

-

-

... More
M&L for isolating, cutting, removing the existing damaged end termination and S&F outdoor end termination, heat shrinkable type suitable for HT UG cable, XLPE insulated of size 3 core x 70 to 95 sq.mm, 11KV grade including preparation complete all as specified and as as directed by engineer in charge. [Make: M-Seal/ Super seal/ Denson/ Raychem]

5

-

-

... More
All as per item No. 13 here-in-before but for HT UG cable of size 3 core x 120 to 240 sq.mm, 11KV grade complete all as specified and as as directed by engineer in charge. [Make: M-Seal/ Super seal/ Denson/ Raychem]

5

-

-

... More
M&L for cutting, removing the existing damaged joint and S&F straight through joint heat shrinkable type suitable for HT UG cable, XLPE insulated of size 3 core 70sqmm to 95 sq.mm, 11KV grade including preparation complete all as specified and as as directed by engineer in charge. [Make: M-Seal/ Super seal/ Denson/ Raychem]

3

-

-

... More
All as per item No. 15 here-in-before but for HT UG cable of size 3 core120 to240 sq.mm, 11KV grade complete all as specified and as as directed by engineer in charge. [Make: M-Seal/ Super seal/ Denson/ Raychem]

5

-

-

... More
Taking up the corroded/ deteriorated GI pipe from the road crossings/ obstructions and supply & laying GI Pipe 100mm dia medium grade complete all as specified and as as directed by engineer in charge. [Make: Tata/ Prakash/ Jindal/ Zenith/ Bansal]

12

-

-

... More
Supply, laying, testing and commissioning of LT XLPE insulated, sheathed, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of size 3.5 core x95 sq.mm. (laid in trenches, ducts, pole, wall etc.) including taking out old unserviceable LT cable from trenches/pole/ducts etc. complete all as specified and as as directed by engineer in charge. Note: (i) Necessary test results like continuity test, megger tests, shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Excavation earth work will be measured and paid separately.

80

-

-

... More
All as per Item No.18 herein before but cable of size 3½ core x 120sq.mm

210

-

-

... More
All as per Item No.18 herein before but cable of size 3½ core x 240sq.mm

80

-

-

... More
All as per Item No.18 herein before but cable of size 3½ core x 400sq.mm

120

-

-

... More
M&L for graded stone aggregate of 63mm size, spread and leveled around 4 pole/ 2 pole structure/ transformer yard complete all as specified and as as directed by engineer- in- charge.

20

-

-

... More
Removing old burnt/ damaged end termination for LT cable 1100 Volt , 3½ core 70 to 150sq.mm and supply and making new end termination with suitable size of lugs duly crimped after isolating supply to transformer/ LT pillar box/ LT panel and disconnecting burnt/ faulty cable from the bunch of cable gland and reconnecting the cable with new nuts, bolts and washers of nickel chromium plated applying petroleum jelly after end termination, testing and commissioning complete all as specified and as directed by Engineer in charge.

11

-

-

... More
All as per Item No. 23 herein before but for cable of size 3½ core x 185 to 300sq.mm

9

-

-

... More
All as per Item No. 23 herein before but for cable of size 3½ core 400 to 500sq.mm

11

-

-

... More
M&L for preparation of old decorated surfaces of walls of transformer plinth by scraping and wire brushing and applying one coat of cement paint complete all as specified and as directed by Engineer in charge.

30

-

-

... More
Cutting bushes, levelling the area around E/M installation such as sub stations, 4/2 pole structure etc. including surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out roots, jungles etc. throw away not less than 50 mtr from the site and making good all as specified and as directed

40

-

-

... More
M&L for writing SM No./MES No. on plants and machinery/ Cope boxe No and feeding location with synthetic enamel paint/ stickering with letters of height 8cm complete all as specified and as directed by Engineer in charge.

25

-

-

... More
Taking out LT panel/junction box of any size by disconnecting all incoming and outgoing cables including breaking of PCC foundation for transporting and fixing in other place safely as directed including re-fixing of LT panel board with new PCC foundation, angle supports, nuts, bolts and washers including transportation like crane, truck etc without disturbing existing electrical system complete all as specified and as directed. Note: (i) Necessary excavtion earthwork, PCC for new place work will be measured and paid seperately. (ii) The cost of braking PCC and removing of Poles is deemed to be included in the Quoted rate. (iii) The cost of transportation for crane, truck etc to shift the removed Panels from one place to another place is deemed to be included in the Quoted rate.

1

-

-

... More
M&L for online centrifuging (filtration/dehydration) of transformer oil including checking dielectric strength of oil before and after filteration for transformers located under GE Haddo area with suitable machine having filteration, heating and pumping facility to improve the dielectric strength / insulation value of the transformer oil upto 60KV/Min. (a) The contractor will take shut down orders in working before commencement of the work from Engineer-in-charge. (b) The contractor shall ensure no wastage of transformer oil. (c) The Contractor is solely responsible for any damage to the transformer during filtration operations. He is responsible for making good any damage to the transformer at his own cost without any extra cost to the department. (d) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration. (e) the di-electric strenght of oil shall be tested before & after filtration. Test results shall be submitted to engineer-in-charge.

14000

-

-

... More
Material and labour for preparation of old painted surfaces of floor mounted indoor/outdoor type transformer from 100 KVA to 500 KVA capacity by cleaning/rubbing with course cloth wire brushes to remove dust deposits oil grease and repainting by applying one coat of spray paint with synthetic enamel paint of approved colour without disturbing/damaging the electrical net work system/equipment including making of capacity /rating /incoming outgoing details in capital english alphabet of suitable size with radium stickers all as specified and directed.

15

-

-

... More
All as per item No 31 above but from 750 KVA to 2000KVA

8

-

-

... More
Supply and fix silica gel breather assembly complete with breather unit and silica gel including connecting with proper rubberised gasket and necessary fittings GI fittings for fixing/assembling upto 2000KVA transformer complete by removing the unserviceable breather assembly all as specified and directed. Make : Patel Electrical Industries or equivalent recommende by OEM

15

-

-

... More
Supply, filling and for topping up the transformer with new transformer oil duly filtered with filtration plant. Make : Power Oil Ltd/Savita/Castrol. Note : (a) The transformer oil shall be type EHV confirming to IS - 3351983. (b) Mineral oil grade shall be used. (c ) The transformer oil should have a high dielectric strength not less than 60 KV/Min.

2300

-

-

... More
Taking down burnt defective drawnout/inlet Valve (Brass 1 1/2" size) and supply and fixing new drawn out/Inlet valve (brass 1 1/2") suitable for any make of 100 to 2000KVA Transformer all as specified and directed

1

-

-

... More
Taking down defective unserviceable LT bush porcelain insulator and supply and fix news LT bush porcelain insulator with oil seal for transformer outdoor/indoor up to capacity of 500 KVA including opening the top cover for fixing of LT Bush if necessary complete all as specified and directed

8

-

-

... More
All as per item No 36 above but of capacity from 750KVA to 2000KVA.

4

-

-

... More
Taking down defective unserviceable HT bush porcelain insulator and supply and fix news HT bush porcelain insulator for transformer outdoor/indoor up to 500KVA including opening the top cover for fixing of LT Bush if necessary complete all as specified and directed

6

-

-

... More
All as per item No 38 above but from 750KVA to 2000KVA.

3

-

-

... More
M&L for isolating the HT supply of transformer, disconnecting HT and LT Cable connections of transformer by opening clamps, bus bar extension and isolating the cables from transformer, outdoor of 100 to 2000 KVA capacities, checking of transformer pressure release valve, oil condition and carrying out tests such as HV/LV megger test, ratio test, magnetic balance test, short circuit test including opening the inspection cover/top lid after drain out of oil as required to check the lead condition from winding to bus rods including necessary soldering/jointing, fixing of new sleeves etc, and charging of transformer and making all necessary connections / assembly & control circuits all as specified and directed.

5

-

-

... More
Taking down unserviceable sheet gasket (Cork sheet), Supply and fix synthetic rubberized cork sheet gasket 6mm thick 2' x 3' size approx sheet thick as required at site for top cover HT/LT bushes at places existing and tighting all the bushings and top cover to avoid any oil leakages of capacity 100 KVA to 500 KVA complete all as specified and directed

2

-

-

... More
All as above item but no. 41 of capacity 750 KVA to 2000KVA

2

-

-

... More
Disconnecting defective out door/indoor transformers, 11KV/433 V of various capacities up to 2000KVA from HT/LT sides taking down transformer oil completely, storing oil in suitable container (to be provided by the contractor), lifting the top cover and core assembly carefully and checking the conditions, refilling the transformer coil completely after necessary repairs, re-fixing core assembly including fixing the top cover and painting to transformer complete all as specified and directed. Note (a) Rewinding of transformer shall be measured and paid separately. (b) In case of major repairs/replacement in transformer, which can not be undertaken at site, the transformer shall be shifted to civil workshop and refixed at site after rewinding by Hydra and connected accessories (complete transformer). (c) Dismantling of core and repairs shall be measured and paid separately. (d) Rate quoted shall deemed to be inclusive of Shifting of transformer to workshop and back. (e) Complete gaskets, nuts and bolts shall be replaced by the contractor and the rate deemed to be inclusive.

3

-

-

... More
M&L for lifting of transformer core of capacity 100 to 500 KVA and keeping the core inside oven chamber to remove moisture and increasing of the insulation value of core and drying the core assembly for minimum 3 days at a temp of 120°C. Note :- (a) Cost for lifting/lowering the core of transformer by crane is inclusive. (b) Labour for fixing the connection/removal of connection inside the heating chamber is inclusive. (c) Power consumption for heating core for improving insulation value is inclusive. (d) Temperature 120°C to be maintained and inclusive in rate quoted.

3

-

-

... More
All as per item no 44 above but of capacity 750 KVA to 2000 KVA.

2

-

-

... More
Taking down burnt defective high tension copper coil of Transformer and supply and fix new HT copper coil made out of proper/ required as per the existing size copper wire enameled of high quality matching with the existing impedance and pre- insulation all as specified and directed. Note : (a) The cost of coil shall be inclusive of varnish sleeving of insulating material. (b) Cost of taking down the clamps, upper channels and core & HT links and re-clamp, positioning with separators, brazing etc completely.

160

-

-

... More
Taking down burnt defective Low tension copper coil/copper strip of Transformer/DG Set alternator and supply and fix new LT copper coil/copper strip of existing size made out of proper/ required copper wire enameled of high quality matching with the existing impedance and pre- insulation all as specified and directed. Note : (a) The cost of coil shall be inclusive of varnish sleeving of insulating material. (b) Cost of taking down the clamps, upper channels and core & LT links and re-clamp, positioning with separators, brazing etc completely.

180

-

-

... More
Taking down unserviceble tinned copper bus bar of various sizes from HT/LT side cable bushing rods from the transformer of 63KVA to 2000KVA capacity and supply and fix electrolyte tinned copper bus bar of suitable size and length including making holes as required at site to the transformer LT/HT side cable bushing rods all as specified and directed.

65

-

-

... More
Supply and fix offload tap changer assembly suitable for 11/.433KV, any make upto 500KVA transformer with 7 tapping position including opening top cover, conservator etc as fixed against repairs all as specified and directed.

1

-

-

... More
All as per Item No.49 above but of capacity 750 - 2000 KVA.

1

-

-

... More
Dismantling of existing cement mortor, taking down the existing transformer platform complete all as specified & directed

10

-

-

... More
Material and labour for air termination single pointed aluminium rod 12 mm dia, 300mm long and taking down the unserviceable/broken one including removing from site all as specified and directedby Engineer-in-Charge.

5

-

-

... More
Material and labour for aluminium strip of size 25 x 3.15 mm with saddle or fixed with screws etc., for roof conductor and down conductor, above ground including taking down unserviceable/broken aluminium strip all as specified and directed. Note : Fixing for insulators will be paid separately.

150

-

-

... More
Material and labour for test point terminal block made of gun metal or phosphorus bronze of size 75 x 25 x 10 mm drilled and screwed including 3 Nos. 8 mm dia, 25 mm long hexa headed screwed including taking down unserviceable one and remove from site all as specified and directed.

3

-

-

... More
M&L for shifting of Transformer of capacity upto 2000KVA from MES power house to variours substations/transformer locations at haddo area by road and removing the faulty transformer from the plingth and fixing/errecting of the healthy tansformer with the hydra/crane support, making necessary HT/LT cable connections, earth connections and restoration of power supply all as specified and as directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.