Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Eprocure
Opening Date18 Oct 2024
Closing Soon7 Nov 2024
Tender Amount₹ 41,00,000
Costs
EMD
₹ 82,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680152_1Tender No
8541ATender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for water proofing treatment with the following specifications including taking down existing roof treatment of any description and cleaning with water and scrubbing and disposing off the rubbish outside the premises, complete all as specified and as per manufacturers instructions:- (i) Rendering 10mm thick in CM 1:4 on concrete surfaces mixed with water proofing compouund @ 3% by weitht of cement as leveling course (ii) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (iii) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5 Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iv) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane.
Note :- Water proofing compound shall be measured and paid separately.
50
-
-
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
125
-
-
S & F coloured joint free non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set, jointed and pointed in white or coloured cement to match over screed bed in cement mortar 1:4, 15 mm thick, complete all as specified and directed.
125
-
-
Material & labour for designer coloured chequred cement concrete tiles of size 20cm x 20cm x 25mm with jointed and pointed in neat cement slurry with grey cement and pigment to match the shade including screed bed 20mm in CM (1:4) complete all as specified and directed.
80
-
-
Taking down cement plaster of any description from wall/ceiling including raking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed.
212.5
-
-
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed.
109.4
-
-
M&L rendering 5mm thick in CM 1:4 with using water proofing compound over 10mm thick in CM 1:6 on external surfaces of block masontry even and smooth eithout using extra cement.(WPC shall be added in only 5mm thick top layer of plaster) complete all as specified and directed.
53.2
-
-
Supply only integral water proofing compound
20
-
-
M&L for rendering 5 mm thick in CM 1:3 finished even and smooth without using extra cement on ceiling including cement slurry 3 kg/sqm complete all as specified and directed.
50
-
-
M & L for two coats of OBD over a coat of primer on newly plastered surfaces of walls including nesessary preparation of surfaces complete all as specified and directed.
109.4
-
-
M&L for two coats of weather coat(Exterior) all guard emulsion, any colour/tined to new wall surfaces over a coat of primer including necessary preparation of wall surfaces complete all as specified and directed.
53.2
-
-
M & L for two coats of OBD over a coat of primer on newly plastered surfaces of ceiling including nesessary preparation of surfaces complete all as specified and directed.
50
-
-
M & L for preparing old decorated surfaces of ceiling and applying two coats of OBD over a coat of primer complete all as specified and directed.
116.4
-
-
M & L for two coats of OBD over a coat of primer on old plastered surfaces of walls including nesessary preparation of surfaces complete all as specified and directed.
109.3
-
-
M&L for two coats of weather coat(Exterior) all guard emulsion, any colour/tined over a coat of primer.including complete removal of old treated wall surfaces.
53.1
-
-
M&L for preparation of old steel surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
100
-
-
Taking down chowkats or frames with shutters area n.exc 1.5 Sqm each(without taking off shutters from the frame) complete all as specified and directed.
6
-
-
All as per Item No.20 above but are exc 1.5 Sqm but n.exc 4.00 Sqm complete all as specified and directed.
4
-
-
S & F Aluminium anodised (minimum anodisation is 15 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangement etc, complete with standard aluminium sections, all as specified and as directed by Engineer-in-charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco).
(Note:- Weight of various Aluminium sections shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only).
150
-
-
Supply only 4 mm thick ACP board (Aluminium Composite Panel ) fixed to aluminium frames complete all as specified and as directed.
8
-
-
Supply only 4mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed.
6
-
-
Supply only aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and as directed.
8
-
-
S&F in 75mm Size Butt hinges type C-21 , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified and as directed.
30
-
-
S&F in 100mm Size Butt hinges type B-21 , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified and as directed.
12
-
-
Supply & Fix in repairs 140mm long door stopper of aluminium alloy body and tounge, anodised with hard drawn steel spring fixed in floor complete all as specified and as directed.
4
-
-
S&F in repairs stainless steel CP coated decorative type curtain rod incl decorative brackets etc complete all as specified and as directed.
10
-
-
Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
4
-
-
M&L for PCC 1:3:6, type C2, (Using 40 mm graded stone aggregate), 100mm thick as in plinth protection/Sub base flooring, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed.
40
-
-
M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 10 to 30 mm from floor/roof slab/chajjas and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles including necessary scaffolding etc and removal of debris to a distance not exceeding 50m, complete all as specified and as directed.
77
-
-
M&L for application of high build polymer modified cement mortar (1:2.5) mixed with 3 kg SBR per bag of cement in ceiling surfaces 10 to 20mm thick in two layers surfaces over a coat of bonding agent Nito Bond SBR (1 Ltr SBR + 1 Ltr) water + 3 kg cement), complete all as specified and as directed.
77
-
-
Materials and labour for removing loose and broken concrete by chiselling /picking etc upto a depth of 50 to 100 mm from columns, beams and similar structural members cutting edges cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign material complete all as specified and as directed.
32
-
-
Materials and labour for applying one coat of anti corrossive primer @ 0.25 Lit/Sqm for the steel area to exposed old and new reinforcement to the full circumfrance and length of bars to form unbroken 40 Micron thick film all as specified and directed.
25
-
-
Materials and labour for applying one coat epoxy bonding agent @ 2.6 sqm/lit or as per manufactures instruction to old concrete surfaces all as specified and directed by Engr-in-Charge to surfaces of columns, beams and similar structural members complete all as specified and as directed.
32
-
-
Use and waste off fair finished flat Form work to RCC columns, posts and similar items including edges complete all as specified and as directed.
32
-
-
Materials and labour for non shrink, cementitous micro concrete mixed with 12.5 graded stone aggregate using Renderoc RG or equivalent as approved by GE (18 Kg Aggregate : 25 Kg Renderoc RG) respectively (as per manufatures instruction) laid in average thickness 50 to 100 mm in situ completee all as specified and directed
1.6
-
-
Materials and labour for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces all as specified.
Make : Concure WB white of Fosroc or equivalent as approved by GE.
32
-
-
Dismantling of posts or struts (wood, steel or RCC) of any section along with old, unserviceable barbed wire, if any, including taking out embedded portion from ground and making good disturbed ground complete all as specified and as directed.
417.6
-
-
M&L for PCC 1:3:6 type C2(using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
5
-
-
Demolition of concrete of any description in any position not other specifically provided for gate post complete all as specified and directed.
42.4
-
-
Dismantling fencing wire mesh, any type complete all as specified and as directed.
1050
-
-
Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out in Hard/dense soil returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm watering and removing surplus soil to a distance not exceeding 50m and making good surfaces complete all as specified and as directed.
116
-
-
S&F Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
2494
-
-
S&F Mild steel TMT bars 5 to 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
1090
-
-
M&L Preparation of newly plastered surfaces of wall & applying Two or more coatsof 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
273
-
-
Use & waste of Form work to sides of square or rectangular columns, pillars, posts and struts for fair finished surfaces of concrete complete all as specified and directed.
181
-
-
Use & waste of Form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for fair finished flat surfaces of concrete complete all as specified and directed.
202
-
-
Providing reinforced cement concrete type B-1, 1:2:4 (20mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc for fencing, average sectional area exc 100 Sq cm, but not exc 250 Sq cm with or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified and directed.
32.6
-
-
Providing reinforced cement concrete type B-1, 1:2:4 (20mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc for fencing, average sectional area n.exc 100 Sq cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and directed.
1.5
-
-
Supply only PVC coated (1mm thick) chain link fencing exc 2.00 but n.exc 3.50 kg per sqm with size of mesh 50 x 50 mm and thickness of wire n.exc 2.83 mm complete all as specified and directed.
4459
-
-
Fixing only PVC coated chain link fencing including fixing of line wires any mesh, size and any type of standards, rails, straining bolts etc including provision of binding wires complete.(Supply of MS line wire and flat iron bolt & nuts measured and paid seperately) complete all as specified and directed.
1365
-
-
Supply only 6mm dia GI wire PVC coated for support/line wire to chain link fencing complete all as specified and as directed.
300.5
-
-
Supply only mild steel angles, bars, flats etc as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
799.5
-
-
Supply only mild steel bolts with hexagonal or square head one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 5 cm long n.exc 10 cm long dia metre of neck exceeding 11 to 15 mm complete all as specified and as directed.
47.5
-
-
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (each line wire to be measured)
22.8
-
-
Material and Labour for painting to new steel and iron surfaces of exc. 10cm wide or girth by two coats of synthetic enamel paints over a coat of red oxide primer including preparation complete all as specified and as directed.
31.2
-
-
M&L for preparation new steel surfaces of any description n.exc 10cm width or girth when unconnected with other painting or when painted in a different tint, and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
15.6
-
-
Taking down carefully aluminium point wiring (light, fan, socket or power) DBs complete offering credit, making good disturbed surfaces of walls, floors, etc, all as specified and as directed.
34
-
-
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets,fan regulators etc., all as specified and as directed forthe following:- (a) One light point controlled by one switch
14
-
-
(b) One fan point controlled by one switch and one regulator
8
-
-
(c) One 3 pin switch socket outlet point 5 amps on independent board
10
-
-
All as per item No 2 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed.
2
-
-
Supply and fix in repair switch piano flush button single pole oneway 5 amp complete all as specified and as directed.
22
-
-
Supply and fix in repair switch socket combination 3 & 2 pin (multi pin) 5 amp flush type complete all as specified and as directed.
10
-
-
Supply and fix in repair switch socket outlet multipurpose 3 pin 15 and 5 amp controlled by one switch, flush type complete all as specified and as directed.
2
-
-
Supply and fix in repair ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and as directed.
22
-
-
Supply and fix in repair fan speed regulator, electronic suitable socket type for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge
8
-
-
Taking down old unserviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site with new clamps, nuts, washers, safety wire of size not less than 1.00mm & bolts including cotter pin for complete all as directed.
8
-
-
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, double door suitable for mounting MCBs including taking down old MCB/DB complete all as specified and directed.
Note-: Incoming & outgoing connections from the DB shall be provided with proper lugs/ thimbles etc
1
-
-
Supply and fix in repair MCB single pole 240 volts, 6 to 32 amps "B" series complete all as specified and as directed.
6
-
-
Supply and fix in repair single pole and netural 240 Volts 32 amps complete all as specified and as directed.
1
-
-
Supply and fixing in repair aluminium housing LED batten 22 /20 Watt mounted batten fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
12
-
-
Supply & Lay in repair XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 35 Sqmm 3.5 Core in trenches/along the wall/including making all connections, saddles, spacers including scaffolding if any required for saddling the cable in walls of building of height up to 25 meter, complete with aluminium lugs as required at site and as directed.
48
-
-
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
7.1
-
-
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
6.3
-
-
Removing excavated soil to a distance not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
0.8
-
-
Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed.
35
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%