Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date19 Sep 2022
Closing Date8 Oct 2022
Tender Amount₹ 48,40,000
Costs
EMD
₹ 96,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_552995_1Bid Award Id
ViewTender No
8680/GE/H/PBTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
1000
-
-
... More
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
600
-
-
... More
M&L for design mix reinforced cement concrete M-30 (Using 20 mm graded stone aggregate) as in Columns, pillars, piers, posts and struts etc complete all as specified and as directed
15
-
-
... More
M&L for design mix renforced cement concrete M-30 (Using 20 mm graded stone aggregate) as in beams,cantilevers,bressummers, etc complete all as specified and as directed
6
-
-
... More
M&L for design mix renforced cement concrete M-30 (Using 20 mm graded stone aggregate) as in Chajjas complete all as specified and as directed
1
-
-
... More
M&L for use and waste of formwork to sides of sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete flat complete all as specified and as directed.
170
-
-
... More
M&L for use and waste of formwork to chajjas, chullah hoods, troughs and similar items including edges for rough finished surfaces of concrete flat complete all as specified and as directed.
9
-
-
... More
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat complete all as specified and as directed.
120
-
-
... More
S&F for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde E-250) Quality -A complete all as specified and as directed
720
-
-
... More
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410-W Gde-E-250) quality A complete all as specified and as directed
4000
-
-
... More
S&F for pre painted Galvalume aluminium zinc coating GI based corrugated / trapezoidal section of steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa (AZ 150) as in roof covering fixed with self tapping screws complete all as specified and as directed
230
-
-
... More
S&F for pre painted Galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa (AZ 150) as in roof covering fixed with self tapping screws complete all as specified and as directed
45
-
-
... More
M&L for aluminium wind tie of any size fixed with self tapping screws with integral EPDM washer in roof covering complete all as specified and as directed
125
-
-
... More
M&L for preparation of new steel surfaces over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed
130
-
-
... More
S&F for mild steel holdfast, bands, straps, bracket/ clamp for eves gutter, valley gutter and similar conforming to Fe-290 Gde-E-165 complete all as specified and as directed
140
-
-
... More
M&L Pre-cast cement concrete block masonry type C1 1:3:6 (20mm graded aggregate)with solid blocks, exc 10cm in width and setting in mortar 1:6 complete
32
-
-
... More
M&L for rendering in two layer i.e. 5mm thick in CM 1:4 including with or without mixing water proofing compound over 10mm thick in CM (1:6) on concrete/block masonry surfaces and finished even and smooth without using extra cement on all as specified(Note WPC shall be measured and paid separately)
210
-
-
... More
M&L for 10mm thick plaster in CM (1:6) on fair faces of concrete/PCC block surfaces of walls finished even and smooth (without using extra cement) all as specified
200
-
-
... More
M&L for preparation of newly plastered wall surfaces with 3mm average thick wall care putty and applying two coat of oil bound distemper over one coat of primer including leveling the surface where undulation found with cement putty etc complete all as specified and directed
200
-
-
... More
M&L for preparation of newly plastered external wall appling two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm / litre and UV resistance as per IS 15489:2004 ,Alkali & fungal resistance ,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre /10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces
210
-
-
... More
M&L for powder coated anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed.
NOTES:
(i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc.
(iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
1300
-
-
... More
Supply only plain sheet glass 4.0 mm thick ordinary quality and glazing with aluminum glazing clip in aluminium window shutter not exc 0.5 Sqm in each pane.
38
-
-
... More
Supply only plain sheet glass 5.5 mm thick ordinary quality and glazing with aluminum glazing clip in aluminum Door shutter exc 0.5 Sqm in each pane.
7
-
-
... More
Supply only Aluminium alloy wire cloth 0.45 mm nominal dia of wire average width of aperture 1.40 mm and fixed with aluminum wire staples all as specified and directed
5
-
-
... More
M&L Pre-laminated particle board 12 mm thk interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work complete all as specified
80.5
-
-
... More
S&F Powder Coated aluminium grill of approved pattern cut to required size/shape and fixed with position with aluminium bedding & frame with & including F sections, fixed to aluminium windows/ventilators complete all as specified and directed
40
-
-
... More
S&F for 110mm dia PVC (SWR) single socketed pipes in any length complete with rubber ring joints laid in fixed to walls etc using synthetic rubber adhesive cement solvent complete all as specified
25
-
-
... More
S&F for 110mm dia PVC (SWR) bends any radius complete all as specified
4
-
-
... More
S&F for 110mm dia PVC (SWR) bends with acess door any radius complete all as specified
4
-
-
... More
Supply only water proofing compound
10
-
-
... More
M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., 6mm thick non-asbestos fibre cement building design boards fixed or laid/ inserted to aluminium frame work with screws complete all as specified and as directed.
198
-
-
... More
Demolition of cement concrete un-reinforced paving n.exc 15 cm thick above or below ground level complete all as specified and as directed
8
-
-
... More
M&L for Cement concrete PCC (1:2:4) Type B2 (using 40 mm graded aggregate) as in sub base 75 mm thick complete all as specified
200
-
-
... More
M&L for vitrified tiles light shade 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white/ coloured cement, laid over and including cement screed bed 15mm thick in cement mortar 1:4 complete all as specified
200
-
-
... More
Ditto all as per item No 38 above but as in skirting/dados etc. including backing coat 10mm thick in cement mortar 1:3 complete all as specified
5
-
-
... More
Supply only plain sheet glass 5.5 mm thick ordinary quality and glazing with aluminum glazing clip in aluminum window shutter not exc 0.5 Sqm in each pane
6.5
-
-
... More
S&F for aluminium (extruded section) body, door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to1000 mm width and of weight between 61 to 80 Kg and fixed complete all as specified and directed
8
-
-
... More
M&L Solar control film 50 micron thick reflective type sicked to glass panes as per instructions of manufacturers complete all as specified and directed
4
-
-
... More
M&L aluminium composite panel sheet of 3.0mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwitched by 2.5mm polyethylene core with PVDF coating of 30.0 micron fixed over frame of aluminium tubular section 25x50mm.20.0mm thick, dully fixed to wall/ceiling with expansion fastner, having panels not exc 1200x1200mm with necessary silicon filling, in approved pattern as in column, beam, wall etc. compete as specified and as directedNote: Necessary MS scaffolding required for work shall be deemed to be included in the quoted rate.
64
-
-
... More
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed / surface PVC conduits (Medium grade) of size not less than 20 mm dia incl proper colour coding Phase -red/yellow/blue, neutral- black and earth green all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories for modular fittings like cover plate with frame and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete for one light/fan point all as specified and directed. Make: Gloster/Havells/Anchor/ Polycab/ Finolex
-
-
-
... More
Description same as per Srl item No 43 above but One light/fan point controlled by one modular switch 5 Amps one way
37
-
-
... More
Description same as per Srl item No 43 above but, point wiring for 5 pin modular switch socket outlet , 6 Amps on independent board
10
-
-
... More
Description same as per Srl item No 43 above but, point wiring for 5 pin modular switch socket outlet , 6 Amps on same board
16
-
-
... More
Description same as per Srl item No 43 above but, One bell point controlled by one modular bell push switch 5 Amps one way
1
-
-
... More
All as per item No 43 above but point wiring with two single core 4.0 sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 6 pin 16 Amps modular socket out let on independent board
5
-
-
... More
S&F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed. Make : Roma (Anchor)/Legrand/Simens/Havells
63
-
-
... More
S&F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed. Make : Roma (Anchor)/Legrand/Simens/Havells
5
-
-
... More
S&F for switch socket outlet, modular type 16 A, 3 pin, flush type controlled by one switch 230 volts AC circuit complete all as specified and directed. Make : Roma (Anchor)/Legrand/Simens/Havells
5
-
-
... More
S&F for socket outlet modular type 1 way 6 Amps, 3 pin, flush type 230 volts AC circuit complete all as specified and directed. Make : Roma (Anchor)/Legrand/Simens/Havells
26
-
-
... More
S&F modular bell push 6 Amp one module 230 V AC Make : Make : Roma (Anchor)/Legrand/Simens/Havells
1
-
-
... More
Supply & fix AC starter switch of capacity 25 Amps working on 240 volts ACsupply , with 15 Amps plug top and 15 Amps Sockets suitble for air conditioner Make : Crabtree Model No : ACAO252504
5
-
-
... More
S&F for ceiling rose, 3 phase, PVC polycarbonate, isolated body complete all as specified and directed
14
-
-
... More
S&F Electric Bell, single pole working on 230 volts AC supply complete all as directed by Engineer -in- charge .Make: Make : Roma (Anchor)/Legrand/Simens/Havells
1
-
-
... More
S&F ceilling fan 1200 mm sweep, 220 Volts, 50 Hz AC supply, white colour including providing of twin core copper wire 23/0.0076 from ceiling fan to ceiling rose complete all as directed. Make: CG Model No. Briz Air Deco/ Usha/ Orient/ Havells
4
-
-
... More
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified.Make:Roma (Anchor)/Legrand/Simens/Havells
8
-
-
... More
S&F recessed mounted 18 watts worm/white round shape/square shape white/yellow colour as required at site , down light LED panel light fitting with ultra bright luminier comprises of thermaly conductive material,pre wired with high effeciency electronic driver with high translucent frosted diffuser gets glare free,smooth light distribution complete all as directed by Engineer-in-Charge. Make : CG Cat Part No : LSCRM-18W-CDL/NW/WW/Philips Cat Part No Astra Max Metal Panel/ Havells
30
-
-
... More
Supplying, fixing and testing Tube light fittings LED 20 watts 4 feet including all accessories and fixing arrangements for fixing the light fitting white/worm (yellow colour) as suitable at site complete all as specified and directed Make Philips Cat Part No : Astra line/ CG Cat Part No. CCS-100-20-65-HL2-DP-NWH/Philips/Havells
2
-
-
... More
Supplying, fixing and testing Tube light fittings 2 feet mirror optical including all accessories and fixing arrangements for fixing the light fitting white/worm (yellow colour) as suitable at site complete all as specified and directed.Make : Philips Model No LED 48027/65/86 ultron/ CG Cat Part No. LCCS-102-10-65-SL-DP-NWH/Philips Model No :Astra Line/Havells
1
-
-
... More
S&F Sub main wiring with PVC insulated cable 2 single core 6 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red/Yellow/Blue, Neutral- black and earth- green in and incl rigid PVC casing and caping on wall (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 4.0 sq mm for earth continuity all as directed. Note : 3 length of cable and one length casing caping shall be measured and paid for one length. Make: Gloster/ Havells/Anchor/Polycab/Finolex
50
-
-
... More
S&F DB VTPN sheet metal enclosure double door suitable for incoming upto MCCB 160 Amps/200 Amps & outgoing MCB TP / SP (IP-43) Protection Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete all as specified and directed. Make : Indo Asian /Havells/L&T/Legrand
1
-
-
... More
Supply and Fixing 4 pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed Make : Indo Asian /Havells/L&T/Legrand
1
-
-
... More
S&F SPN DB sheet metal enclosure double door suitable (IP-43) Protection 10 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete. Make : Indo Asian/Havells/L&T
1
-
-
... More
S&F MCB SPN 40 Amps (`C’ series) having current rating 10 KA complete all as specified and directed Make : Indo Asian /Havells/L&T
1
-
-
... More
S&F MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed Make : Indo Asian/Havells/L&T
20
-
-
... More
M&L of submain wiring in repair with 2 runs of 6.0 Sq mm multistranded copper conductor PVC insulated (FRLS), 1100 Volts grade and one run of 4.0 sqmm PVC insulated (FRLS) multistranded copper earth continuity conductor including lugs of suitable size drawn in and including rigid PVC casing & caping of suitable size but not less than 25 mm width complete all as directed .Make of wire : Polycab/Gloster/Anchor/ Havells/ Finolex and Make of PVC conduit : Modi/Precision/Supreme/Finolex /Polycab NOTE : Two runs of 6.0 Sqmm cable, one run of 4.0 Sqmm cable alongwith PVC casing & caping shall be measured as one unit.
20
-
-
... More
M&L of submain wiring in repair with 2 runs of 4.0 Sq mm multistranded copper conductor PVC insulated (FRLS), 1100 Volts grade and one run of 2.5 sqmm PVC insulated (FRLS) multistranded copper earth continuity conductor including lugs of suitable size drawn in and including rigid PVC casing & caping of suitable size but not less than 25 mm width complete all as directed .Make of wire : Polycab/Gloster/Anchor/ Havells/ Finolex and Make of PVC conduit : Modi/Precision/Supreme/Finolex /Polycab NOTE : Two runs of 4.0 Sqmm cable, one run of 2.5 Sqmm cable alongwith PVC casing & caping shall be measured as one unit
60
-
-
... More
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed.
NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
1
-
-
... More
Supply,laying,testing and commissioning of LT XLPE insulated, sheathed, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of size 25 sqmm sqmm 3.5 core core (laid in trenches, ducts, pole, wall etc.) including taking out old unserviceable LT cable from trenches/pole/ducts etc. complete all as specified and as directed by Engineer in Charge.Note : (i). Necessary test results like continuity test, megger tests, shall be submitted to Engineer-in-Charge before the cable is laid.(ii). Excavation earth work will be measured and paid separately Make:Make:Gloster/Havells/Anchor/Polycab/Finolex
120
-
-
... More
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm including coupler, o ring and bend etc complete polyethylene with smooth internal and profiled external surface for non pressure upto 95 Sqmm under ground cable complete all as specified.Make : REX POLYEXTRUSION LTD or its equivalent as approved
110
-
-