Military Engineer Services Tender

... More
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date26 May 2020
Closing Date20 Jun 2020
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(c) DHPP (Diesel) will be issued by MES free for filling for consumption/use for running of DG Sets. (d) The fuel tank of DG Set shall be top upped with diesel as available in the barrels before 12 hrs of starting of Captive DG set.(Note: Diesel shall be issued by MES for topping up fuel tank and proper documents shall be mentained about topping up diesel for each DG Set) (e) The person deployed in shift will not allowed to leave the duty station until reliver reported and take over the complete installation for operation of complete installation. In case of absence of operator in the installation , penality to the tune of double the quoted unit rate shall be imposed.

-

-

-

... More
(f) Log Sheet , Shut down Ragister, Maintinace register, Installation earthing testing register and break down register, Fuel register, Hours Run register as avaialble with installation shall be properly mentained by the person depolyed in respective shifts (g) After filling of fuel tanks empty barrels shall be kept at the location earmarked. (h) Minor items such as grease, cotton and other spanners/ tools & plants as required for handling of DG sets shall be arranged by the contractor. (j) Quoted unit rate shall be deemed to be inclusive of all activities as above.

-

-

-

... More
(k) Salary of the operators be paid by the contractor in their respective Adhar linked accounts confirming to labour law of Andaman Nicobar Govt and summary will be produced to the department at time of payment. (l) Tools for minor repair be provided by the Contractor. (f) Uniform with safety shoe, first aid box for operator will be provided by the contractor. (m) Man power deployed by the contractor shall have enrolled with with EPF & ESIC. (n) Man power shall have insurance for Rs. 2.00 Lakh provided by the Contractor. (o) While operating the DG set some minor items such as greases, cotton co waste etc. shall be provided by the contractor , the contractor shall quote their unit rate accordingly.

-

-

-

... More
Material and Labour for Comprehensive maintenance of under mentioned HT/LT Panels at Captive Power House with qualified engineer / technician for regular periodical service to ensure safe operation and safe function of tripping mechanism of installation :- (a) Vaccum Circuit Breaker 400 Amps - 2 Nos (b) Transformer Floor mounted Step up 415/11000 Volts Indoor Type Capacity- 400 KVA - 2 Nos (c) LT Air circuit breakers of capacity 600 to 1200 Am ps (d) Synchronizing panels and safety relays and floot cum boost battery chargers and control wiring

2

-

-

... More
Note :- (i) The rate includes minor spare parts for VCB and LT panels. (ii) The maintenance work should be carried out through qualified engineer as and when required and the cost of transportation, boarding and messing shall be included in the quoted rate. (iii) For seticfactry comprehensive maitinance of Panels , all Panels shall be got checked /tested by rep of OEM in terms of OEM of Panels set instrctuctions and certficate in this regard shall be obtained, same shall be submitted to Engineer in Charge for thier setsfaction (iv) Before commencement of work 1st Inspection of Rep of OEM shall be carried out by the contractor so as to get proper running/maintinace Panels

-

-

-

... More
Material and Labour for comprehensive and preventive maintenance of under mentioned DG Set for day to day, weekly, monthly, quarterly and half yearly through qualified engineer as per manufacturer’s instruction or authenticated by Kirloskar Engineer:- (a) DG Set No - I (500 KVA) DV2/KV seies (b) DG Set No - II (500 KVA) (c) DG Set No - I (400 KVA) KV Series (d) DG Set No - II (400 KVA) KV Series (e) DG Set No - (600 KVA) DV2 Series (f) DG Set - 1010KVA -01 Nos

12

-

-

... More
Note :- (i) (i)The complete periodical maintenance of captive DG set to be carried out during the contract period with 1 Kirloskar Senior Engineer (OEM) having minimum 5 year experience in maintenance of DG set. (ii) All consumable store required for captive power DG Set will be supplied under Sch `A' Part III except cotton waste, grease and any minor parts to ensure Engine and Alternator Operational (iii) The stationery and registers required should be provided for the period of contract. (iv) Any minor repair occurred to be cleared within 24 hrs and major repair will be cleared within one week. (v) (v) At any given time during contract period all DG set should be kept serviceable except during maintenance period and major repair. (iv) Before commencement of work 1st Inspection of Rep of OEM shall be carried out by the contractor for all DG Sets, so as to get proper running/maintinace DG Sets

-

-

-

... More
Note :- Contd... (v) At any given time during contract period all DG set should be kept serviceable except during maintenance period and major repair. (vi) Service engineer deployed to carrying out periodical maintenance in DG set should be brought out any major spare parts requirements for replacement before one month through inspection note. (vii) The complete captive installation and surrounding area to be kept clean around the clock with available manpower during shift duties. (viii) The maintenance work should be carried out through qualified engineer as and when required and the cost of transportation, boarding and messing be included in the quoted rates. (ix) Spare parts shall be measured and paind under respective items (iv) Before commencement of work 1st Inspection of Rep of OEM shall be carried out by the contractor for all DG Sets, so as to get proper running/maintinace DG Sets

-

-

-

... More
Supply of Engine Oil (type ‘K’ Oil of supper grade SAE 15-40) or as specified by manufacturer for topping up or replacement of lubricating oils during periodical maintenance/daily checks complete all as specified and as directed.

1500

-

-

... More
Supply only Lub oil filter suitable for 600/500 KVA DG Set of KOEL Part No. DVO. 014.27 for DV 2 series engine all as specified and directed.

22

-

-

... More
Supply only Lub oil filter suitable for 600/500 KVA DG Set of KOEL Part No. DVO. 014.11 for DV 2 Series engine all as specified and directed.

22

-

-

... More
Supply only Fuel filter catridge suitable for 600/500 KVA DG Set of KOEL Part No. DVO. 020.03.0.00. for DV2 series engine

44

-

-

... More
Supply only Water Separator filter for DV2 series engine all as specified and directed.

4

-

-

... More
Supply only Water Separator filter mounting assembly complete for DV2 series engine all as specified and directed.

2

-

-

... More
Supply only Air Cleaner Primary Element for DV2 series engine 600 KVA all as specified and directed.

2

-

-

... More
Supply only Air Cleaner Safety Element for DV 2 series engine 600 KVA all as specified and directed.

2

-

-

... More
Supply only Air Cleaner Primary Element for DV2 series engine 500 KVA all as specified and directed.

2

-

-

... More
Supply only Air Cleaner Safety Element for DV 2 series engine 500 KVA all as specified and directed.

2

-

-

... More
Supply only Lub oil filter suitable for 400/500 KVA DG Sets of KOEL Part No. KVO. 043.03.0.00 all as specified and directed.

24

-

-

... More
Supply only Fuel filter suitable for 400/500 KVA DG Sets of KOEL Part No. KVO. 110.01.0.00 all as specified and directed.

12

-

-

... More
Supply only Fuel filter element KOEL Part No. KV2. 506.20.0.00 all as specified and directed.

12

-

-

... More
Supply only Seal ring for fuel pre filter Part No. KV2. 506.09.0.00 all as specified and directed.

10

-

-

... More
Supply only Air Cleaner Primary Element Part No. KV8.505.02.0.00 for 400 KVA engine all as specified and directed.

2

-

-

... More
Supply only Air Cleaner safety Element Part No. KV8.505.03.0.00 for 400 KVA engine all as specified and directed.

2

-

-

... More
Supply only coolant premixer DFC 50 all as specified and directed.

218

-

-

... More
Supply only Water Separator with complete assembly Part No. KV2.506.05.0.00 for 400 KVA engine all as specified and directed.

4

-

-

... More
Supply only V Belt wrapped 1170 DVO.016.23.0.00 suitable for engine pully to charging alternator 600/500 KVA DV2 series engine all as specified and directed.

2

-

-

... More
Supply only V Belt Cogged B X 58 DVO.016.08.0.00 suitable for engine pully to radiator fan pully/water pump 600/500 KVA DV 2 series engine all as specified and directed.

4

-

-

... More
Supply only V Belt Cogged DV2.016.01.0.00 suitable for engine pully to radiator fan pully/water pump 600/500 KVA DV 2 series engine all as specified and directed.

2

-

-

... More
Supply only V Belt Cogged suitable for engine pully to charging alternator 400 KVA KV series engine all as specified and directed.

3

-

-

... More
Supply only V Belt Cogged suitable for engine pully to radiator fan pully/water pump 400 KVA KV series engine all as specified and directed.

3

-

-

... More
Supply only automatic voltage regulator having terminal of PQR , F1,F2 aand R1 R2 suitable for 500/400 KVA alternator as per standared excitation voltage with variable triacs for control the voltage, stability etc Make - Altex

1

-

-

... More
Supply only self starter motor DC 24 volts suitable for DV2 engine 600 KVA Make - Lucas, CD TVS,Boosh or equivalnet

1

-

-

... More
Supply only self starter motor DC 24 volts suitable for DV2 engine 500 KVA Make - Lucas, CD TVS,Boosh or equivalnet

1

-

-

... More
Supply only self starter motor DC 24 volts suitable for KVO engine 400 KVA Make - Lucas, CD TVS,Boosh or equivalnet

1

-

-

... More
Supply only charging alternator 24 volts DC suitable for 1500 RPM engine with voltage control regulator all as directed

1

-

-

... More
Supply only Hose TC Drain KVO.047.19.0.00 all as specified and directed.

6

-

-

... More
Supply only under voltage trip device (UVT) for ACBs oerating voltage 415 volts

1

-

-

... More
Supply only Shunt trip/closing coil oerating voltage 220/415 volts

1

-

-

... More
Supply only key inter lock

1

-

-

... More
Supply only indicator lamp RYB LED type

3

-

-

... More
Supply only arc chute 415 volts suitable for 600 to 1200 ACBs

3

-

-

... More
Supply only arcing contact moving 600 to 1200 amps ACBs

1

-

-

... More
Supply only Hose rubber inter cooler to engine suitable for DV2 series engine all as directed

2

-

-

... More
Supply only hose rubber engine to radiator suitable for DV2 series engine all as directed

2

-

-

... More
Supply only flex hose for vent F6.669.09.0.00

1

-

-

... More
Supply only sensor unit with thermostat element

3

-

-

... More
Supply only intake manifold DVO.023.09.0.00

1

-

-

... More
Supply only Fuel pipe for tank to filter with necessary fixing arrangement

2

-

-

... More
Supply only automatic voltage regulator having terminal of PQR , F1,F2 aand R1 R2, Q1 Q2, A1 A2 suitable for 600/500 KVA alternator as per standared excitation voltage 67 volts with variable triacs for control the voltage, stability etc Model TVAR 30 or TVAR 15 Make - Kirloskar Green

1

-

-

... More
Supply only Engine speed controler unit KVO.105.03.0.00 (Actuator controller)

1

-

-

... More
Material and Labour for Comprehensive and preventive maintenance of transformer including taking shut down from main substation and drain out the transformer oil and to be collected in barrel by opening the transformer cover of capacity 630 to 1500 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking the any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required complete for entire satisfaction of Engineer in Charge. under mentioned Stepup Transformer for Monthly , quarterly, Half yearly and Annual through OEM as per their instructions:- (i) Transformer 1000 KVA - Make: (ii) Transformer 500KVA -02 Nos Make:

3

-

-

... More
Note: (i) OEM Certificate /Test Report Must be submitted to the Department at the time of Payment. (ii) Consumable item will be paid seprately.

-

-

-

... More
Material and Labour for Comprehensive and preventive maintenance of VCB Taking proper shutdown & Isolate the HT electric supply and taking out the trolley of VCB HT 11KV 400 to 630 amps of any make and type and servicing of all minor/major parts of the VCB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire trolley component all as directed , inserting the trolley, testing the complete HT electric supply and putting on supply on load complete all as directed. under mentioned Vaccum Circuit Breaker for Monthly , quarterly, Half yearly and Annual through OEM as per their instructions:- (i)Vaccum Circuit Breaker-07 Nos Make: Note: OEM Certificate /Test Report Must be submitted to the Department at the time of Payment. (ii) Consumable item will be paid seprately.

7

-

-

... More
Dehydration of transformer oil with proper dehydration machine to achieve dielectric strength between 45 to 50 KV including testing/recording of dielectric strength result before and after of dehydration complete all as specified and directed.

2000

-

-

... More
Supply only transformer oil having dielectric strength not less than 45 KV complete all as specified and directed.Make: Castrol/ Savita.

420

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.