Military Engineer Services Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Dec 2024
Closing Soon24 Dec 2024
Tender Amount₹ 39,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material and labour for preparation of old painted surface of Diesel /Elect Driven fire pump set with base frame (main pump/Jockey Pump) incl engine of cap 53.0 to 122.8 KW and motor of cap 45 to 110 KW (set of 4) incl diesel tank alongwith connected accessories inside the insatllation by scaraping out old painted surfaces and spray painting with synthetic enamel paint of existing colour all as specified and directed by Engr-in-Charge.

1

-

-

... More
Material and labour for preparation of old painted surface of GI pipe of diff size (Header 600 mm dia 6.00 mtr, Discharge pipe 300 mm dia 14.0 mtr, 200 mm dia 1.6 mtr, 100 mm dia 6.6 mtr) alongwith valves, NRV etc of any size connected with Fire fighting pumping sets incl the suppoting structure also inside the insatllation by scaraping out old painted surfaces and spray painting with synthetic enamel paint of existing colour all as specified and directed by Engr-in-Charge.

1

-

-

... More
M & L for Mechanical seals suitabile for VT Pump of discharge capacity 53 to 227 cum / hrs to prevent lekages all as per OEM recommendations all as specifed and as directed.

2

-

-

... More
M&L for Laser alignment of fire fighting pumping set with motor of cap 45 to 110 KW of any make/ model set complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
M & L taking down of damgaed glad packing from existing motor installed with VT pump of discharge cap 53 to 227 Cum/hrs and fix the new glad packing all as specified and directed by Engr In Charge.

4

-

-

... More
S & F in replacement Pressure gauge (steel body) 4" dial 0-14 kgs rating all as specified and as directed by Engr In Charge.

4

-

-

... More
Material and Labour for lifting the RCC slab upto 300 mm thick and about 2.5 ton to 4 ton in weight on jetty by cutting / chipping the clearance groove all around, keeping aside using a crane and refixing at the same location after carrying out repairs/ laying of pipeline including making good the surface with PCC 1:2:4, type B1, using 20mm graded stone aggregate complete all as specified and directed.

15

-

-

... More
M & L for taking down of GI flanged pipe of size 150 mm dia from duct , wall etc and re-fixing the same after reparing i.e. welding work, stopping leakage by fixing with rubber sheet not less than 3 mm and alingmnent with a correct manner etc all as specified and directed by Engr In Charge.

120

-

-

... More
Material and labour for preparation of old painted surface of GI flanged pipe of size 150 mm dia with bend, Tee etc alongwith valves, NRV, Hydrants etc of any size connected with fire water pipe line laid with any position i.e. duct, wall, alongwith Jetty (mounted with GI angle angle/channel at the interval of 1-2 mtr) , incl the suppoting structure also by scaraping out old painted surfaces and spray painting with synthetic enamel paint of existing colour, marking/ writing with black paint for direction, location etc all as specified and directed by Engr-in-Charge. (Note:- The Pipe laid inside duct should be painted and the lifting of duct shall be measured and paid separately under recpective items of BOQ)

480

-

-

... More
Description all as per item no 12 above but 80 mm dia.

100

-

-

... More
S & F cast iron sluice valve, 150 mm size or bore, class PN 1.6, ISI marked, heavy duty with brass spindle, operating wheel, flanged on both ends along with suitable new rubber packing (gasket), stainless steel bolts, nuts & washers and necessary modifications if required for fixing in location including taking down old unserviceable sluice valve of any description complete all as specified and as directed.

1

-

-

... More
M & L for taking down of the unsv expansion bellow and S & F in replacement of expansion bellow made of steel of size 300 mm dia with flange fixed in any position as complete all as specified and as directed.

1

-

-

... More
Description all as per item no 15 above but 200 mm dia.

1

-

-

... More
Description all as per item no 15 above but 150 mm dia.

1

-

-

... More
Description all as per item no 15 above but 80 mm dia.

1

-

-

... More
S&F hydrant valve for fire fighting, single headed, ISI marked, conforming to IS:5290, 63 mm dia or bore made of SS-304, oblique type with instantaneous hose coupling adapter etc., with necessary fitting material including taking down old unsv fire hydrant valve complete all as specified and as directed.

4

-

-

... More
S & F Non return valve flange type of size 200 mm dia (8") , ISI marked, heavy duty (as existing at site) complete all as specified and as directed.

1

-

-

... More
S & F Non return valve flange type of size 300 mm dia (12"), ISI marked, heavy duty(as existing at site) complete all as specified and as directed.

1

-

-

... More
S&F butterfly valve, 200 mm size or bore (8"), ISI marked, heavy duty brass, side handle operated (as existing at site) for fire fighting including taking down old unserviceable one complete all as specified and as directed.

1

-

-

... More
Description all as per item No 22 above but 150 mm size or bore (6").

1

-

-

... More
Description all as per item No 22 above but 100 mm size or bore (4").

1

-

-

... More
Description all as per item No 22 above but 80 mm size or bore (3").

1

-

-

... More
M&L for replacement of 150 mm dia or bore galvanized steel tubing with all fitting, heavy duty, with all fittings and laid on floor/ in trenches, ducts etc or fixed to walls and ceilings, with outside colour coding in RED/BLUE including taking down old unserviceable pipe complete all as specified and as directed.

15

-

-

... More
Description all as per item No 26 but 80 mm dia.

15

-

-

... More
Taking down unserviceable self-starter 12 volts from 53 to 122.8 KW of diesel engine installed fire fighting pumping set of make-Greaves , as existing, dismantling and opening of stater and armature,replace the wornout carbon brush, pinion,ignition coil bearing,bushing, including servicing, varnishing of stater after repairing assembling,refixed to same position complete all as specified and directed.

2

-

-

... More
S&F in repairs Electronic timer with auxiliary voltage of 110/240v, 50Hz for operation of 9-30 sec complete all as specified and as directed by Engineer-in-charge.

1

-

-

... More
M&L for carrying out "B" check for 53 to 122.8 KW diesel engine installed fire fighting pumping set of make-Greaves , as existing as per manufacturer's recommendation including replacement of necessary spares and Filters such as Fuel filter, SLO Bypass filter and lub oil filter complete including rectification of minor defects, cleaning of air filters/ breather & coolant tank with air blower, replacement of Engine oil & coolant and tuning of engine all as specified and directed. [Notes: (i) Supply only Engine oil & Coolant shall be measured and paid separately. (ii) Rate quoted shall include for all filters, topping up distilled water in batteries & minor accessories like nuts, bolts, 'O' rings etc.]

4

-

-

... More
Supply only Engine oil 15w 40 type:CH4 or CI4 as per requirement and manufacturer recommendation .

80

-

-

... More
Supply only Engine coolant suitable for 53 to 122.8 KW diesel engine, Make-Greaves

20

-

-

... More
S&F battery terminal, brass heavy duty (two nos) complete suitable for fixing on battery poles with nuts and bolts complete including disconnecting and taking down unserviceable battery terminal all as specified and directed.

4

-

-

... More
S&F battery lead copper conductor single core 70 sq.mm, 2 metre long (two nos) complete including soldering of copper lugs including disconnecting and taking down unserviceable battery lead complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supply and fixing of square shaped cooling fan (6") suitable for LT Panel alomgwith connection, testing complete alla s specified and directed by Engr in charge.

2

-

-

... More
Dismantling of Fuel pump from 53 to 122.8 KW of diesel engine installed fire fighting pumping set , make-Greaves for Replacement of FIP Solenoid switch for fuel pump and re-connecting for the same fuel pump properly including all as specified .

2

-

-

... More
Draininng up the fuel tank/Diesel tank in a separate empty barrels, disconnecting the fuel lines from the fuel filters and taking out the fuel tank and clearing internally and remove the accumulated slludge/Sediments and arresting leakages, reconnecting back all the removed fuel lines and mounting the diesel tank its orginal position, supply and replacing the drain plug suitable and including painting of external surfaces by using synthetic enamel paint of two coats over one coat of red oxide primer testing complete for 53 to 122.8 KW of diesel engine of make- Greaves .

2

-

-

... More
Supply and connect and test lead acid battery heavy duty 12 volt 180 AH complete with initial charging complete all as specified.

1

-

-

... More
Supply and fix against repairs SMPS/ Automatic battery charger 240 V input , 12 V / 10 - 15 Amps output with auto cut off and floating with selector switch and indicators, set of fuses complete all as spcified and directed by Engineer-in-charge.

1

-

-

... More
M & L for Checking of 53 to 122.8 KW of diesel engine internel connections like battery connections, solenoid adjusting and PCB contoller etc and tuning of DG Set of capacity 30KVA to 125KVA when and as required basis complete all as directed.

1

-

-

... More
S&F PCB Controller as per existing make and model as per site requirement and suitable for 53 to 122.8 KW of diesel engine including making connections and tuning of DG Set including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge.

1

-

-

... More
S&F in repairs fuel hose pipe/lube oil hose pipe of 10 mm to 25 mm dia (60psi) flexible type, heavy duty as per existing length for 53 to 122.8 KW of diesel engine complete all as directed.

4

-

-

... More
S&F in repairs fuel hose pipe/lube oil hose pipe of 32 mm to 50mm dia flexible type, heavy duty as per existing length for 53 to 122.8 KW of diesel engine complete all as directed.

3

-

-

... More
M&L Cotton waste for cleaning of DG sets all as specified and as directed by Engineer-in-charge.

12

-

-

... More
Taking down old Silencer Exhaust pipe of any dia and length of existing make and model mouted at any height and cleaning with cleaning agents, metal filling as per site requirement for 53 to 122.8 KW of diesel engine, refixing the same Silencer Exhaust pipe with necessary new nuts, bolts and washers including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Taking down old Silencer Exhaust pipe and S&F Silencer Exhaust pipe with wool insulation of any dia and length of existing make and model mouted at any height as per site requirement for 53 to 122.8 KW of diesel engine installed with necessary new nuts, bolts and washers including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge.

1

-

-

... More
Taking down the unsv shaft connected fixed between Engine and VT Pump of discharge capacity 53 to 227 cum / hrs and replaced with new as per site requirement, re-assembling, commissioning, testing complete all as specified and directed by Engr In Charge.

1

-

-

... More
S & F in replacement Panel LED Phase indicator (R-Y-G) along with connected wiring not less than 1.0 sqmm copper wire all as specified and directed by Engr In Charge.

7

-

-

... More
S & F in replacement of Volt meter/ Ammter analog type of size 72 x 72 mm,1 phase, class -1, 0.5 VA with connected wiring all as specified and directed by Engr In Charge.

4

-

-

... More
S & F in replacement of MCCB 3 pole, 500/630 Amps, 50 Hz, 415 Volts, 50 KA Adjustable Thermal and Fixed Magnetic setting, with separator link - 1 No . (Make - L&T, Havells, Indoasian)

1

-

-

... More
Description all as item No 50.0 above but 160 Amps, 50 KA. (Make - L&T, havells, Indoasian)

1

-

-

... More
Description all as item No 50.0 above but 200 Amps, 36 KA. (Make - L&T, havells, Indoasian)

2

-

-

... More
S & F PVC Insulated and PVC Round Sheathed 3 core 1.5 sqmm Bright Annealed Bare Copper Conductor Heavy Duty Flexible Cables for Voltage Grade 1100 Volts. Make : Polycab /Gloster/ Anchor/ Havells/ Finolex

60

-

-

... More
S & F in replacement of MN 12 Thermal over load relay, nominal CT ratio -30 Amp complete all as specified and directed by Engr In Charge. Make- L & T or equivalent. (Make-L&T, Siemens or equivalent)

1

-

-

... More
S & F in replacement of 3 Pole Power Contactor MO 70 type, Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 along with all connection after installation of the same complete all as specified and directed by Engr In Charge. (Make-L&T, Siemens or equivalent)

1

-

-

... More
Decription all as per item No 55.0 but MO 95 type.

1

-

-

... More
Decription all as per item No 55.0 but MO 110 type.

1

-

-

... More
Decription all as per item No 55.0 but MO 250 type.

1

-

-

... More
S & F in replacement of electronic timer , 240 VAC, 50/60 Hz/ , Timing 3s to 120s , pulse timing 60 ms along with all connection after installation of the same complete all as specified and directed by Engr In Charge. Make- L & T or equivalent.

1

-

-

... More
Supply & Fixing in replacement of hooter suitable for 240 V , AC for fire fighting control Panel complete all as specified and directed by Engr In Charge.

1

-

-

... More
M & L for disconnection the power supply and servicing / repairing the fire fighting system alarm/indication control panel, checking the heathness of the all the control wiring , calibration , testing of the panel including replacement of spares and make it functional with satisfaction of Engr In Charge complete all as specified and directed.

1

-

-

... More
M & L for disconnection the power supply and servicing / repairing the LT control panel cum starter panel for control of Motors of diff cap, checking the heathness of the all the control wiring ,calibration of relays, testing of the panel indications, tightening of all the connectors/moving parts etc make it functional with satisfaction of Engr In Charge complete all as specified and directed.

1

-

-

... More
Supply and filling/top up of hydraulic oil upto required level in Engine, VT Pump of any cap complete all as specified and directed by Engr In Charge.

1

-

-

... More
Transportaion and labour for shifting of Diesel by container (cap 200 ltrs each), from NSRY Power House to NSCB (Ross Islands) DG substation all as specified and directed by Engr In Charge. NOTE:- (i) The quoted rate is for shifting of one filled container (200 Ltrs) only. (ii) The quoted rate is included for necessary T&P, vehicle, boat, labours etc for shifting of Diesel. (iii) The each container of Diesel should be transported upto DG Installation at NSCB Islands. (iv) The Containers shall be Contractor's property for the entire contract period. (v) Always min 10 x filled containers of Diesel should be kept at Substation (Ross Isands) as standby. (vi) The Contractor will plan for shifting of Diesel before ending the reserve quantity of Diesel and inform to Engr In Charge.

63

-

-

... More
M&L for carrying out "B" check for 15 KVA diesel engine installed at NSCB Islands set of make-Greaves , as per manufacturer's recommendation including replacement of necessary spares and Filters such as Fuel filter, SLO Bypass filter and lub oil filter complete including rectification of minor defects, cleaning of air filters/ breather & coolant tank with air blower, replacement of Engine oil & coolant and tuning of engine all as specified and directed. [Notes: (i) Supply only Engine oil & Coolant shall be measured and paid separately. (ii) Rate quoted shall include for all filters, topping up distilled water in batteries & minor accessories like nuts, bolts, 'O' rings etc.]

6

-

-

... More
Supply and fixing with wall/ pillar/ iron structure etc of hot dip galvanised perforated cable tray, with solid cover fabricated from GI Sheet in standared length of 2.4 mtr of thickness 1.2 mm , depth 50 mm , width 300 mm anolgwith ,accessories i.e. bends (any type), right/left/center reducer , tee, straight coupler etc as required at site including MS work for support/ hanging of suitable size as directed complete all as specified and directed by Engr In Charge . Note:- (i) The measurement shall be calculated as RM incl accessories for the cable tray.

30

-

-

... More
Supply and laying of Insulating mats for working LT 1100 V, of class 'B' confirming to IS 15652//2006, ISI marked , High Die electric Strength , water and moisture proof of size 2 mtr x1 mtr x 2.0 mm. complete all as specified and directed.

5

-

-

... More
Material and labour in replacement Retro Reflective installation sign boards of size 4 feet x 4 feet fabricated out of 16 gauge MS sheet ,framed with stainless steel heavy duty pipe of size 50 mm bore duly welded/riveted with MS square pipe of size 25 mm x 25 mm at height 1.5 meter above ground level on stainless steel heavy duty pipe of size 50 mm bore embaded 60 CM in PCC 1:2:4 type B 1 block of size 45 cm x 45 cm x 45 cm including necessary excavation and earth work .The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The wiriting matter i.e. details of Installation, location etc. will be in English language on both sides with reflective adhesive painted tapes all as directed and specified by Engineer -in-charge.

2

-

-

... More
Material and labour for making of Schematic diagram network glow sign board of E/M installation duly comprising of following details:-follows:- (a) The diagram board should be not less than 6' x 5' x 6" (b) The structure should be made of framed by Stainless steel square tube 25 mm x 25 mm (c) The top sheet should be white acrelic sheet and rear sheet should be not less than 1.5 mm thick MS sheet. (d) 04 x 20 watt LED tube light fitted inside the diagram alongwith complete wiring with controlling switch. (d) It should be hanged on the wall by drilling and fixing as directed. (e) Min 10 mtr PVC sheathed wire 1.5 sqmm 3 core . (f) The schematic diagram should be prepared by the contractor as per site data.

1

-

-

... More
Material and labour for fixing of Retro Reflective installation board of size 4 feet x 5 feet ,framed with stainless steel heavy duty square pipe of size 25 mm x 25 duly welded with SS plate , 2 mm thick with hanging arrangement to be fixed with wall as dirtected. The details of Installation/equipments should be mentioned with reflective sticker on blue background film and the wiriting materials i.e. details of Installation, location etc. will be in English language on front side with reflective adhesive painted tapes all as directed and specified by Engineer -in-charge. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.

4

-

-

... More
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip 32 mm x6 mm as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.

3

-

-

... More
M & L for Chemical earthing complete with copper earth plate electrode 90cm x 60cm x 5mm thick burried in ground vertically to a depth not less than 5 mtrs below ground level with top edge of plate at a depth not less than 4.25 mtrs below nominal ground level with a bottom layer MG SO4 of 10cm thick, earth plate surrounded with graphite powder, vegetable soil mixture, charcol and common salt in equal proportion around and 15cm above the plate and 10cm thick MG SO4 as top layer and the remaining portion filled with excavated earth and connected with copper strip 32mm x 6mm duly brazed up to 7.5 mtrs length and connected to earthing test point, GI pipe light grade 40mm bore for watering with funnel and wire mesh all as shown in Elect Plate No.3 of MES Sch Pt I and as specified and testing on completion including provn of earth pit with necessary earth work, PCC (1:2:4) type B1 Chamber, cast iron frame with hinged pit cover of size 12" x 12" having 7kg weight complete all as specified and directed. NOTE : (i) All the joint copper strips shall be of brasing only. (ii) Test result of Earthing to be submitted by Contractor for all earthing. (iii) Earth resistance value should be less than 1 ohm for each earthing.

2

-

-

... More
S & F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required copper strip 32 x 6 mm all as directed ad specified.

30

-

-

... More
S & F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strip 32 x 6 mm all as directed ad specified.

40

-

-

... More
Disconnection the power supply, opening the automatic fire dection system control panel, servicing/checking/ cleaning the panel, cheking all the connection , testing the panel alongwith smoke detectors, control wiring etc upto satisfaction level of Engr In Charge complete all as specified and directed.

1

-

-

... More
S& F in replacement of smoke detectors mounted at any height of ceiling/roof complete all as specified and directed.

25

-

-

... More
Supply,laying,testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2 x 10 sqmm (laid in terenches,ducts,pole,wall etc.) incl taking down old unsv cable all as specified and directed.

100

-

-

... More
All as per above item No.77.0 here in before but cable size 4 x 16 sqmm.

300

-

-

... More
All as per above item No. 77.0 here in before but of cable size 4 x 25 sqmm .

46

-

-

... More
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 40 mm(OD) x 32mm (ID) along with connected accessories like couplers.bends,end caps etc. for HT cable protection all as specified and directed.Make:Rex Poly Extrusion Ltd/ Tirupati Plastomatics Pvt Ltd.

85

-

-

... More
All as per above item No 80.0 here in before but of size 50 mm(OD) x 38mm(ID).

294.1

-

-

... More
Supply & fix in replacement FRP pole box 170 x 170 x 105 mm consisting of 1 No 50 A 4 pole connector and 1 No 16 A MCB SP including taking down the old/unserviceable junction boxes all as specified and directed. Make : SINTEX Cat No. GS-JB-1414 or equivalent & Make of MCB: L&T/Havells/ Legrand/Indo Asian

4

-

-

... More
Supply & fix in replacement FRP pole box 240 x 130 x 95 mm (inside dimension) consisting of 1 No 50 A 4 pole connector and 1 No 6-16 A MCB SP(as required) including taking down the old/unserviceable junction boxes all as specified and directed. Make : SINTEX Cat No. GS-JB or equivalent Make of MCB: L&T/Havells/ Legrand/ Indo Asian

6

-

-

... More
LABOUR ONLY for repairing and rectification of faults in security lights / street lights/ flood lights / highbay lights by disconnecting the electrical connections and bringing on ground and refixing the same, back in position after carrying out repairs by checking the peanut lamps/ electrical connections/ electronic drivers etc., and testing after making it fully serviceable by checking the condition of electronic driver and replacing only if required complete all as specified and as directed. NOTES : (i) One Electrician and one helper shall be deputed daily to JE E/Ms office during office hours to ascertain the repairs to be carried out for lights under his AOR.(ii) Necessary T & P arrangements for carrying out repairs shall be under taken by the contractor.

15

-

-

... More
Supply and fixing of LED street light fixture of cap 70 watt ,aerodynamically designed for all weather conditions with excellent thermal management, made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. Efficacy 110/120 LPW, with 10KV SPD including taking down the old unsv light fitting of any type all as specified and directed. Make: CG Model No :TRP-409-70-57-SL-GL-NSG or equivalent model of /Philips/ Havells/ Luker

10

-

-

... More
Supply and fixing in replacement of LED floodlight of cap 200 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, System efficacy ≥ 110/120LPW 10KV included driver including fixing on High mast of any hight or any pole/ wall/ iron structure etc including taking down of the old unserviceable halogen/any type of old unsv light fittings all as specified and directed. Make: CG Model No : LFLN-200-CDL/60-M or equivalent model of /Philips/Havells/Luker

15

-

-

... More
Description all as per item No 86.0 above but LED floodlight of cap 135 watt. Make: CG Model No :LFLN-135-CDL/60-M or equivalent model of /Philips/Havells/Luker

6

-

-

... More
S & F Sub main wiring with PVC insulated cable 2 single core 2.5 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red/Yellow/Blue, Neutral- black and earth- green in and incl rigid PVC conduit concealed in wall/ on surface/ below ground (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 2.5 sq mm for earth continuity incl taking down of old existing sub main wriring all as specified and directed.

50

-

-

... More
S&F MCB, SP, "C" series, 240 volts, 6-32 Amps, 10kA rupturing capacity including taking down old unserviceable one complete all as specified and as directed.

35

-

-

... More
S&F MCB, SPN, "C" series, 240 volts, 40 Amps, 10kA rupturing capacity including taking down old unserviceable one complete all as specified and as directed.

5

-

-

... More
S&F MCB, TPN, "C" series, 240 volts, 40-100 Amps, 10kA rupturing capacity including taking down old unserviceable one complete all as specified and as directed.

6

-

-

... More
LABOUR ONLY for repairing and rectification of in High mast light fixed at a height of 16m to 32m by disconnecting the electrical connections and bringing on ground by operating existing motor and refixing the same, back in position after carrying out repairs/ servicing the Mechanism incl greasing of steel rope by checking electrical connections/ electronic drivers/ light fittings etc., and testing after making it fully serviceable complete all as specified and as directed. NOTES : (i) Necessary items to be replaced shall be measured as supply only under revevant item of the Schedule. (ii) Necessary arrangements for carrying out repairs shall be under taken by the contractor.

1

-

-

... More
Taking down old timer panel and supply and fixing of out door type Street light timer Panel /Distribution Boards with pole, panel etc as directed alongwith 65A 3 pole/230 Volts contactor and Digital 24 hrs/ Analog Time Switch, 63 A MCB, Manual and Auto Mode Toggle switch cable connectors, cable gland etc including suitable fixing arrangement with existing pole/ panel all as specified and directed. Make: Cat No. TL065AB0 of indoasian Time lite or equivalent.

1

-

-

... More
Supply and fix in replacement of timer heavy duty analog time switches of 110- 230 V 50Hz with built in battery, 16A capacity with backup of 100 hrs weekly programmable all as specified and directed including taking down the old damaged timer. Make : Indo Asian Cat No : TA926453 or equivalent in L&T/ Legrand / Havells

1

-

-

... More
Supply and fix in replacement of contactor , 3 pole, 415V, 40A cap , ML2 , 2 NO+NC utilised for heavy duty by taking down the old perished / deteriorated contactor aganist repairs all as specified and directed. Make: L&T Cat No SS90701,or equivalent Havells or INDO ASIAN CAT No 850533

1

-

-

... More
Preparation of old painted surfaces GRP / steel tubular poles with double arms of street lights upto 10.0 metre height by scraping with emery paper and making free from rust, dust and any foreign material and applying one coat of synthetic enamel paint of tint as directed including letter writing such as pole number and source point of electric supply with black paint and fluorescent paint in circumference of poles /mast towers of various heights complete all as specified and as directed.

17

-

-

... More
Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed.

55

-

-

... More
Taking down existing unserviceable main switches/ distribution boards/Fuse Units of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.

2

-

-

... More
Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed.

87

-

-

... More
Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.

210

-

-

... More
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25 mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3 mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for the following :-

-

-

-

... More
ONE LIGHT/FAN point controlled by one, one way 5 Amps switch.

22

-

-

... More
ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on independent board.

12

-

-

... More
ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on same board.

9

-

-

... More
ONE BELL point controlled by one, one way 5 Amps switch.

2

-

-

... More
Description same as per item Sl No 101 above but point wiring with two single core 4.0 Sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 3 pin 15 Amps socket out let on independent board complete all as specified and directed.

10

-

-

... More
S & F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed.

63

-

-

... More
S & F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed.

36

-

-

... More
S & F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16, universal complete all as specified and directed.

20

-

-

... More
S & F Switch modular type , single pole one way 16 amps complete all as specified and directed.

18

-

-

... More
S & F modular bell push 5Amps flush type 230v, 50Hz AC complete all as specified and directed.

2

-

-

... More
S&F, Electric Bell, Ding dong type working on 230 volts AC supply complete all as specified and directed.

5

-

-

... More
S & F stepped type, electronic fan regulator modular type complete all as specified and directed.

20

-

-

... More
M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 5A, 240 volts complete all as specified and as directed.

16

-

-

... More
S&F in repairs switch socket combination box type 2 in 1, 5 pin, 5 Amps, flush type,universal complete all as specified and as directed. Make: Anchor/Cona/Legrand

10

-

-

... More
S&F in repairs switch socket combination box type 2 in 1, 6 pin, 5 Amps & 15 Amps, flush type,universal complete all as specified and as directed. Make: Anchor/Cona/Legrand

10

-

-

... More
S & F in replacement of capacitor 2.5 mfd, 230 Volts for ceiling fans including taking out old unserviceable one complete all as specified and as directed. Make:- Capco/ Univarsal/ Tibcon/ Epcos

50

-

-

... More
Taking down carefully ceiling fan of any sweep/ cap/ make from its existing position of any height/ loaction after disconnecting from electricity, dismantling blades, opening up for carrying out servicing/over hauling, examining for damaged worn out parts like shaft, ball bearings etc., and applying grease to bearings, assembling back, preparing painted surfaces by cleaning dust, grease etc., and by filling cavities with filler to receive spray paint using synthetic enamel paint of existing shade, fixing up blades and hanging back in position and providing and connecting up with 1.0 sqmm twin core twisted flexible copper conductor of suitable length from connector of fan to ceiling rose and testing complete all as specified and as directed.

40

-

-

... More
Description same as per item Sl No 113 above but, exhaust fan of any sweep/cap/type complete all as specified and directed.

5

-

-

... More
Description same as per item Sl No 113 above but, wall mounted fan of 600 mm sweep complete all as specified and directed.

4

-

-

... More
S & F air ventilating fan 250 mm sweep single ph, 230 volt, PVC body with louvers incl all fixing arrangement complete all as specified and directed. Make: Havells, model No- FHVVEDXOWH10 Ventil Air DX or CG, Model No: BRISK AIR NEO or equivalent to Orient / Usha/ Khaitan

3

-

-

... More
S & F in replacement of Supply & fix motor starter switch of capacity 25 Amps working on 240 volts AC supply alongwith with 25 Amps mini MCB SP type 'C' 240 volts for air conditioner complete all as specified and directed.

6

-

-

... More
M&L for Sub main wiring complete with four runs (3P+1N) of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32 mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25 mm dia PVC conduit and conduit accessories fixed in concealed or on surface of wall/ceiling/roof/ floor complete all as specified and as directed.

40

-

-

... More
Description same as per item Sl No 118 above but sub main wiring with four runs (3P+1N) of 6.0 Sqmm single core duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire. NOTE for item No 118 & 119: Four runs (3P+1N) of copper conductor, One run of copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.

20

-

-

... More
Description same as per item Sl No 118 above but sub main wiring with two runs (1P+1N) of 6.0 Sqmm single core duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire.

30

-

-

... More
Description same as per item Sl No 118 above but sub main wiring with two runs (1P+1N) of 4.0 Sqmm single core duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire.

70

-

-

... More
Description same as per item Sl No 118 above but sub main wiring with two runs (1P+1N) of 1.5 Sqmm single core duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire. NOTE for Item No( 120 to 122): Two runs (1P+1N) of copper conductor, One run of 1.5 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.

50

-

-

... More
Supply and fixing Insulated Plug & Socket with single pole + neutral and earth encolsure with a three pin plug with socket complete with one MCB SPN of 32 Amps (`C’ series) having current rating 10 KA all as specified and directed. Make- Havells model No -DHDPBDP032 or equivalent

4

-

-

... More
Supply and fixing Insulated Plug & Socket with three pole + neutral and earth encolsure with a five pin plug with socket complete with one MCB TPN of 32 Amps (`C’ series) having current rating 10 KA all as specified and directed. Make- Havells model No -DHDPBTN032 or equivalent

2

-

-

... More
S & F in replacement of Triple pole and neutral sheet steel powder coated Distribution board IP -43 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 415 V, 50 Hz supply double door TPN DB system 04 ways, and making good to the distrubed surface /walls complete all as specified and directed.

2

-

-

... More
S & F in replacement of MCB DB, SPN, 12-way, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.

1

-

-

... More
Description same as per item Sl No 126 above but 8 way.

1

-

-

... More
S & F in replacement of MCCB, 4 pole, 100 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed.

1

-

-

... More
S & F in replacement of MCCB, 4 pole, 63 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed.

1

-

-

... More
S & F in replacement of MCB, TP, "C" series, 230 volts, 40-63 Amps, 10 KA rupturing capacity complete all as specified and as directed.

3

-

-

... More
S & F in replacement of MCB, SPN, "C" series, 230 volts, 32 Amps, 10 KA rupturing capacity complete all as specified and as directed.

8

-

-

... More
S & F in replacement of RCCB for earth leakage protection double pole, 240 volts, 40 Amps, 100 mA rupturing capacity complete all as specified and as directed.

4

-

-

... More
S & F in replacement of RCCB for earth leakage protection four pole, 415 volts, 80 Amps, 100 mA rupturing capacity complete all as specified and as directed.

1

-

-

... More
S & F of LED slim panel lighting fixture of 15 Watt recess mounted 220V , 50Hz with finished in premium white powder coating ,environmental friendly energy efficient fitting recess mounted round/square in shape (Warm white/ white colour as per requirement of site complete) of light as required at site) complete all as specified and directed. Make - Luker Cat Part No : LNPR15 or equivalent make in CG/ Philips/ Havells. NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting .

20

-

-

... More
S & F of 18 watts surface mounted LED light fitting , white/yellow colour as reuired as site with slim high perfomanance surfaced mounted LED light fittings, round/square shape as required at site made from die-cast aluminium and CRCA covering, powder coated in white colour complete all as specified and directed. MAKE: Luker Cat No LNPSRR18 or equivalent make of Havells/ CG/ Philips

4

-

-

... More
S & F in replacement and testing Tube light fittings LED 20 watts 4 feet including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Luker Cat Part No : LT5M20 or equivalent to CG/Philips/ Havells

35

-

-

... More
S & F in replacement and testing Tube light fittings LED 10 watts 2 feet including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Luker Cat Part No : LT510P or equivalent to CG/Philips Havells

10

-

-

... More
S & F in replacement of LED tube of cap 20 watt, 4' long suitable for existing light fitting installed at any position incl taking down of fitting and re-fixing of the same after replacing the tube all as specified and directed by Engr In Charge.

30

-

-

... More
S & F in replacement of and testing LED recessed mounted 595 mm x 595 mm luminarie with high transmitive diffuser of cap 40 watt, with longer life and less maintenance including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: LUKER model No LKM 2240 of any colour (WH/NWH/WW) as reuired or equivalent to Philips/CG/ Havells . NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting

9

-

-

... More
S & F Surface mounted general purpose square shaped luminaire with low height CRCA housing and high transmissivity diffuser of cap 40 watt of size 595 mm x595mm x 65 mm including all accessories and fixing arrangements for fixing the light fitting to any heighted indoor palces complete all as specified and directed. Make :- Luker model No- LKMSRS40 or equivalent to Havells/ CG/ Philips

9

-

-

... More
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.

1

-

-

... More
S & F in replacement of PVC insulated copper conductor cable of following sizes, 1100 Volts grade,singl core of any colour for Phase/ neutral of earth, Heavy Duty, served with inner sheathing (flexible) industrial cable complete all as specified.

-

-

-

... More
10.0 sqmm single core

35

-

-

... More
6.0 sqmm single core

32

-

-

... More
4.0 sqmm single core

75

-

-

... More
1.5 sqmm single core

55

-

-

... More
Taking down carefully existing split type air conditoner of any make,type, size and any tonnage keep in safe custody of contractor and painting the outer area and re-fixing the same after charging of gas, adding new copper pipe line as required at its location after completion of work all as directed.

3

-

-

... More
M&L for Repair to point wiring for light/fan/socket by cutting, removing and replacing the burnt and unserviceable wire with new FRLS cable and conduits with copper conductor 1.5/2.5 Sqmm size, jointing with same size wires, replacing the saddles, refixing the loose/hanging conduits/casing capping properly all as directed. Note:(i) Rate is inclusive for FRLS cable and other minor items (ii) The representative of the contractor shall report to Engineer-in-charge/JE on daily basis to carry out repairs and completion report to be submitted all as specified and as directed

35

-

-

... More
S&F in replacement of MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and directed.

25

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.