Military Engineer Services Tender
... More
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Mar 2025
Closing Date26 Mar 2025
Tender Amount₹ 34,50,000
Costs
EMD
₹ 69,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_700323_1Tender No
8194/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(c) 4 Core x 10 Sqmm Note for item 1.00 to 1.30:- Excavation, Earthwork, GI Pipe, etc. will be measured and paid under appropriate Items.
100
-
-
... More
Taking out old serviceable XLPE LT cable of any size and rerouting or relaying the same complete all as specified and directed.
200
-
-
... More
S & F of HDPE double wall corrugated pipe confirming to IS -14930 Part with IP protection IP-67 having inner dia 40 mm terminated up to termination end point complete all as specified and as directed.
700
-
-
... More
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge.
85.05
-
-
... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed by Engineer-in-Charge
75
-
-
... More
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge
10
-
-
... More
M & L for road cutting by manually for laying of LT UG cable/Galvanised Iron pipe including making good to distrubed surface after the completion of work with PCC 1:2:4 type B-2 on top including levelling and cambering according to existing road surface, refilling, watering, ramming etc all as specified and as directed.
12
-
-
... More
S & F GI pipe 50mm bore light grade with all fittings laid in trenches/on wall / on poles etc/ for protection complete all as specified and directed.
12
-
-
... More
Supply & Erecting Octagonal pole (7.0 Metre long) including Base Plate, suitable for mounting on RCC foundation alongwith accessories such as arm/ holding brackets, hold fast, base plate, foundation bolt, brackets shall be made of specified size NB and G.I heavy duty pipe approx. 1.4 M long, bent at the centre at an angle of 105 degrees, with necessary holding brackets, hold fasts etc. with special reducer at end to accommodate any type of street light fitting. The Pole along with bracket shall have one coat of anti-corrosion paint before dispatch to site and two coats of approved make and shade of enamel paint including writing MES Pole No.with synthetic Enamel Paint (First Grade/quality), complete all as specified and as directed.
NOTE : Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items.
4
-
-
... More
M&L Cement Concrete 1:4:8 (40mm graded aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Formwork (as/if required), complete all as specified and as directed.
1.22
-
-
... More
M&L Cement Concrete 1:2:4 (20mm graded aggregate) as in Coping of Poles, etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), complete all as specified and as directed.
0.36
-
-
... More
Taking down LED street light fitting/ LED flood light fitting of any watts and type from any height of pole/walls/high mast of any location and detecting the fault in the fitting by checking the accessories, wiring and refixing the same after repairs & incorporating the faulty spares complete all as directed by Engineer-in-Charge.
Note : Spares like driver and other accessories etc will be measured and paid separately under relevant items
120
-
-
... More
Supply only LED Driver suitable for existing upto 30 W LED light fittings complete all as specified and directed. Note for item :Drivers shall be techincally compatible for existing type of fittings & frame size shall be matched to existing fittings.
30
-
-
... More
Description all as per item No.13.00, but Driver suitable for more than 30 W and upto 60 W LED light Fittings
40
-
-
... More
Description all as per item No.13.00, but Driver suitable for more than 90 W and upto 150 W LED light Fittings
20
-
-
... More
Supply, installation, testing and commissioning integral LED Aviation Light 12W comprising aluminum Housing with polycarbonate enclosure including all necessary drilling, bolting or riveting etc complete all as specified and directed
Make : Bajaj, Phillips, Havells, Wipro or equivalent
Note : Necessary mounting arrangements for the lights are deemed to be inclusive in above quoted rates
1
-
-
... More
Supply, installation & testing light emitting diode street light Luminaries compressing pressure, die cast housing for better aesthetics and thermal management. Comprises of extruded aluminium housing with pre-wired gear tray with LED’s & drive, heat resistant flat glass suitable gasketed for IP 66 protection, high grade power coating and fitted with toughened glass with high power LED’s of not less than 60 watt incl surge protection complete including taking down existing fittings all as specified and directed. Make: Wipro, Havells, Phillips or equivalent
22
-
-
... More
Supply, installation & testing light emitting diode street light Luminaries compressing pressure, die cast housing for better aesthetics and thermal management. Comprises of extruded aluminium housing with pre-wired gear tray with LED’s & drive, heat resistant flat glass suitable gasketed for IP 66 protection, high grade power coating and fitted with toughened glass with high power LED’s of not less than 90 watt incl surge protection complete including taking down existing fittings all as specified and directed. Make: Wipro, Havells, Phillips or equivalent
8
-
-
... More
Supply and fixing post top lantern LED type 35 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 66 protection with impact and corrosion resistant complete with driver and lamp complete.
Make: Wipro, Havells, Phillips or equivalent
2
-
-
... More
Supply and fixing bollard type LED type, 8 watt, 300lumens, warm white, 230 volts AC outdoor type with decorative bollard light IP 66 , Ik10 impact protection with impact and corrosion resistant complete with driver and lamp complete.
Make: Wipro, Havells, Phillips or equivalent
4
-
-
... More
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
4
-
-
... More
Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
6
-
-
... More
M & L for servicing/maintenance of high mast incl servicing of wrench, winding of motor, servicing of chain, pulley, lantern holder and all other movable parts etc all as specified and as directed by Engineer-in-Charge.
4
-
-
... More
S&F in replacement of GI Pipe bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary arrangement for fixing the existing street light fitting on pole / wall with two sets of clamps made out of flat iron 32 x 6mm, bolts, nuts and washers including applying two coats of aluminium paint over on coat of red oxide zinc chrome primer complete all as directed by Engr-in-Charge.
20
-
-
... More
M & L for PVC cable with copper conductor 1.5 sqmm, 2 core, 1100 volts grade multistranded for connecting from existing junction box to street light fitting including PVC conduit complete all as specified and directed
Make : Havells / Polycab / Finolex or equivalent
400
-
-
... More
Supply and fixing of PVC Junction box of size 140 x 140 x 95 mm, pole mounting hinged type including necessary clamp for MCB mounting and mounting of Box on pole/pipe with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as directed by Engr-in-charge. Make : Sintex / Hensel or equivalent
20
-
-
... More
Supply and fixing of PVC Junction box of size 270 x 225 x 135 mm, pole mounting hinged type including necessary clamp for MCB mounting and mounting of Box on pole/pipe with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as directed by Engr-in-charge. Make : Sintex / Hensel or equivalent
40
-
-
... More
M & L for switching on and off the street lights based on astro time controlling switch for automatic controller of street light with sheet metal enclosure consist of 230 Volt Astronomical Time Switch, 40 Amp MCB, contactor, internally pre wired, terminal blocks mounting brackets, cable glands and openable door with lock and key and manual setting features complete all as specefied and directed. Make: L&T, Legrand, Havells.
1
-
-
... More
S&F channel/flat iron of suitable size and remoulding the same by cutting/bending for fixing of junction boxes on poles of any type and any size with and including bolts, nuts and washers including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer complete all as specified and directed.
50
-
-
... More
M&L for cleaning LT/Street light poles of 8.5/9.0 mtrs long and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of aluminum paint over a coat of red oxide primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engineer-in-Charge.
70
-
-
... More
M&L for cleaning LT/Street light poles of 8.5/9.0 mtrs long and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of synthetic enamel weather proof emulsion distemper paint and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engineer-in-Charge.
60
-
-
... More
Supply & Fix MCB TPN, 32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002, integrated label holder, sliding bottom clamp, IP 20 protected terminal, sliding shutters, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc.
Make : Legrand / L&T / Havells or equivalent
5
-
-
... More
Description all as per item No.30.00, but MCB TPN 40 A
5
-
-
... More
Description all as per item No.30.00, but MCB SPN 32 A, 240V
10
-
-
... More
Description all as per item No.30.00, but MCB SP 6-32 A, 240V
60
-
-
... More
M&L for earthing with galvanised steel earth plate electrode 60cmX60cmX6mm burried earth pit not less than 2.25m depth below normal ground level with to edge of the plate vertically to depth of not less than 1.5 m below ground level connected to & including Galvanised earth strip of size 25 x 4 mm by mean of GI bolts & nuts etc with provision of char-coal and salt etc all as per electrical plate No-3 of SSR-2010 including RCC cover and MS angle iron frame, watering with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc. complete all as specified and directed by Engineer-in-charge.
Note : 1. Earth work is deemed to be included in the Quoted Rate.
2. GI Strip as required at site is deemed to be included in the quoted rate.
6
-
-
... More
Periodical maintenance of DG set as per manufacturer recommendation including painting of the following DG sets installed at various location and various capacity complete all as specified and directed by Engineer-in-charge.
-
-
-
... More
DG set 140/160/320 KVA Capacity
9
-
-
... More
DG set 125 KVA Capacity
6
-
-
... More
DG set 82.50 KVA Capacity
1
-
-
... More
DG set 62.5 KVA Capacity
4
-
-
... More
DG set 50 KVA Capacity
2
-
-
... More
DG set 30 KVA Capacity
1
-
-
... More
DG set 25/20 KVA Capacity
2
-
-
... More
Note:- Item No. 32.10 to 32.70
(a) Checking the fanbelt , Fuel , Oil filter, Air Filter, FIP Performance,FIP Oil level, Tappet Clearance, adjustment of fuel pump timing, tighting of base bolt nuts, battery distilled water level, vibration damper mounting, radiator, radiator hose, panel board cable connection tighting.
(b) Service engineer report from authorised dealer shall be submitted for every check about the performance and maintenance of DG Sets
(c). Highly skilled labours and tools for maintenance/checks repairs/replacement is deemed to be included in the rate quoated by the contractor
(d). Replacement of spares , Coolant,Distilled water , Engine Oil, Fuel/Oil/Air filter shall be measured under relevant items & Minor spares parts including door hinges, indicator lamp are deemed to be included in the quoted rate.
-
-
-
... More
Disconnecting, removing and dismantling radiator assembly from the following capacity DG sets and descaling the radiator thoroughly with using suitable any other chemical solvent agent as approved by the Engineer-in-Charge, stopping of leakeage at place to copper cores and tubes by brazing scrapping the existing Oil paint, dusting and painting the radiator with enamelled paint etc re-installing and commissioning all as directedby Engineer-in-charge
-
-
-
... More
20 KVA to 62.5 KVA Capacity Genset
2
-
-
... More
82.5 KVA to 160 KVA Capacity Genset
2
-
-
... More
320 KVA Capacity Genset
1
-
-
... More
Disconecting the existing battery of capacity 12V upto 100 AH from the DG Set, taking it to battery workshop, draining out the complete unserviceable sulphuric acid from the battery, filling up with new sulphuric acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG Set, start the engine for satisfactory function all as directed by Engineer-in-Charge.
2
-
-
... More
All as per item No. 34.00 herein before but 12V,180AH
2
-
-
... More
M&L for replacing the worn out carbon brushes slip ring type in alternator of any capacity DG set including all necessary connected works all as directed by Engineer-in-Charge.
5
-
-
... More
M&L for removing defective AVR from Alternator and replacing with new AVR upto 82.5 KVA DG sets Make as per existing all as specified and directed by Engineer -in-Charge
2
-
-
... More
All as per item 36.00 here in before but Alternator capacity more than 125 KVA and upto 320 KVA Capacity. Make as per existing all as specified and directed by Engineer -in-Charge
2
-
-
... More
Material and labour for disconnecting electrical and mechanical connections of the following capacity Alternatror , 415V, 50 HZ removing from foundation/diesel engine coupling and Transporting private Work shop, dismantling the alternator in parts and removing the burn out copper winding coil carefully, cleaning slots and replacing the insulation paper and winding F class copper conductor winding wire of exsisting size/shape , glass sleeves of connecting leads, binding/tightining loose coils with binding cloths , varnishing and applying the bactol on the excitor coil/winding with supper varnish, heating the windings at appropriate tempeature to achive required insulation resistance with out damaging the other parts, replacement of driving and non-driving end bearings, cleaning ,greasing, reassembling/installing/connecting and testing with megger for insualtion resistance etc as directed by the Engineer-in-charge
-
-
-
... More
25 KVA to 100 KVA Capacity Genset
1
-
-
... More
125 KVA to 160 KVA Capacity Genset
1
-
-
... More
320 KVA Capacity Genset
1
-
-
... More
M&L for replacing the old unserviceable battery lead with copper terminals approximately 2.5 mtr length including applying jelly over the battery pole and terminals all as directed by Engineer-in-Charge.
6
-
-
... More
M&L for replacing the old unserviceable battery Terminals ( Positive& Negative ) including brazing work and applying jelly over the battery pole and terminals all as directed by Engineer-in-Charge.
5
-
-
... More
M&L for replacing the damaged/burn out battery terminal pole (positive/negative) 12 V DC battery and recosting lead as per the site requirement complete all as specified and directed by the Enginner-in-charge
5
-
-
... More
Supply and fix in replacement of the following spares during repairs :-
-
-
-
... More
Oil filter suitable for 20 KVA to 50 KVA Capacity Genset with 'O' ring
5
-
-
... More
Oil filter suitable for 62.5 KVA to 100 KVA Capacity Genset with 'O' ring
5
-
-
... More
Oil filter suitable for 125 KVA to 320 KVA Capacity Genset with 'O' ring
22
-
-
... More
Diesel filter 20 KVA to 50 KVA Capacity Genset with 'O' ring
10
-
-
... More
Diesel filter 62.5 KVA to 100 KVA Capacity Genset with 'O' ring
10
-
-
... More
Diesel filter 125 KVA to 320 KVA Capacity Genset with 'O' ring
21
-
-
... More
Air filter suitable for 20 KVA to 50 KVA Capacity Genset
4
-
-
... More
Air filter suitable for 62.5 KVA to 100 KVA Capacity Genset
3
-
-
... More
Air filter suitable for 125 KVA to 320 KVA Capacity Genset
4
-
-
... More
Rocker arm packing kit suitable for 20 KVA to 50 KVA Capacity Genset
1
-
-
... More
Rocker arm packing kit for 62.5 KVA to 100 KVA Capacity Genset
1
-
-
... More
Rocker arm packing kit 125 KVA to 140 KVA Capacity Genset
1
-
-
... More
Engine Oill 20W-40. Make : Castrol/BP
420
-
-
... More
Radiator Coolant premix type
220
-
-
... More
Distilled Water with PVC Container
50
-
-
... More
Electrolite with PVC Container
10
-
-
... More
Bearing Grease
2
-
-
... More
Petrolium Jelly
2
-
-
... More
Cotton Waste
2
-
-
... More
Selector Switch as per sample
2
-
-
... More
Contactors any size
2
-
-
... More
M & L for replacing the existing damaged/bulged radiator flexible rubber hose for the following capacity DG sets installed at various installation and replaced with new radiator flexible hose with circular hose clips complete all as specified and directed by the Engineer-in-charge.
-
-
-
... More
20 KVA to 50 KVA Capacity Genset
2
-
-
... More
62.5 KVA to 100 KVA Capacity Genset
1
-
-
... More
125 KVA to 320 KVA Capacity Genset
2
-
-
... More
Taking down the existing worn out Fanbelt (V Belt) for the following capacity installed at various installation and replaced with new fan belt complete all as specified and directed by the Engineer-in-charge
-
-
-
... More
20 KVA to 50 KVA Capacity Genset
2
-
-
... More
62.5 KVA to 100 KVA Capacity Genset
2
-
-
... More
125 KVA to 320 KVA Capacity Genset
3
-
-
... More
Taking down the existing unserviceable water pump assy for the following capacity DG Sets installed at various installation and replaced with new water pump assy complete all as specified and directed by the Engineer-in-charge
-
-
-
... More
20 KVA to 50 KVA Capacity Genset
1
-
-
... More
62.5 KVA to 100 KVA Capacity Genset
1
-
-
... More
125 KVA to 320 KVA Capacity Genset
1
-
-
... More
Taking down the existing defective panel board indication lamp (RYB) from the panel and replaced with LED indicator lamp with holder complete all as specified and directed by the Engineer-in-charge
2
-
-
... More
Taking down the existing defective RPM meter along with cable and replaced with RPM meter complete all as specified and directed by the Engineer-in-charge
1
-
-
... More
Taking down the existing defective radiator cap from the Radiator and replaced with new radiator cap complete all as specified and directed by the Engineer-in-charge
2
-
-
... More
Taking down the existing unserviceable Oil pump assy for the following capacity DG Sets installed at various installation and replaced with new Oil pump assy complete all as specified and directed by the Engineer-in-charge
-
-
-
... More
20 KVA to 82.5 KVA Capacity Genset
1
-
-
... More
100 KVA to 160 KVA Capacity Genset
1
-
-
... More
320 KVA Capacity Genset
1
-
-
... More
Taking down the existing Unserviceable panel board ON/Off push button and replaced with new push button complete all as specified and directed by the Enginner-in-charge
2
-
-
... More
Taking down the existing defective injector and fuel injection pump (FIP)for the following capacity DG Set installed at various installation and replacement of work out spares like delivery valves, Nozzles, bearings, fly weight, packing kit, and copper washer kit and recalibration of FIP and refixing in same position and testing of full load checking of pressure complete all as specified and directed by the Engineer-in-charge
-
-
-
... More
20 KVA to 82.5 KVA Capacity Genset
1
-
-
... More
100 KVA to 160 KVA Capacity Genset
1
-
-
... More
320 KVA Capacity Genset
1
-
-
... More
Taking down the existing defective DC Ammeter and volt meter from the panel and replaced with new Combined DC Ammeter and Volt meter including necessary wiring and wiring material complete all as specified and directed by the Engineer-in-charge
1
-
-
... More
Taking down the existing defective Self starter from Genset 12 V Capacity installed at various installation and replacement of work out spares like Bendex drive, carbon brush, solenoid coil, Armature including rewinding stator, refixing in same position and testing complete all as specified and directed by the Engineer-in-charge
2
-
-
... More
Taking down the existing defective unserviceable Self starter from Genset 12 V Capacity installed and replace with new self starter in same position and testing complete all as specified and directed by the Engineer-in-charge. Make - LUCAS/TVS or equivelent as per existing make.
1
-
-
... More
Taking down the existing defective/damaged Oil flexible ( Metal mesh/rubber) hose and replaced with new Oil flexible hose for upto 160 KVA capacity Genset including replacement of connector etc., complete all as specified and directed by the Engineer-in-charge
4
-
-
... More
S&F Battery12 V 180 AH for DG set complete all as specified and directed by Engr-in-charge.
2
-
-
... More
S&F Battery12 V 100/90 AH for DG set complete all as specified and directed by Engr-in-charge.
Make for Item No. 62 & 63: AMCO/KIRLOSKAR/EXIDE XPRESS/AMARAJA
1
-
-
... More
Taking down the existing defective water temperature gauge from the panel and replaced with water temperature gauge along with connected links complete all as specified and directed by the Engineer -in-charge
2
-
-
... More
Material & Labour for overhauling of DG Set 320 KVA such as works of Engine piston, cylinder head, crankshaft, camshaft, lathe works including replacement of bearing bush, turbo charger, connecting rod bolt, piston ring set, cylinder liner, intermediate ring, bush for injector etc and replacement of other worn out or damaged items as required all as specified and as directed by Engineer-in-Charge.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%