Military Engineer Services Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Civil And Construction
Solid Waste Management
Pipe Line Project
Eprocure
Opening Date21 Nov 2024
Closing Date5 Dec 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Summary

Repairs And Cleaning Of Sewage Lines, Repair To Drains, Hard Standing, Ms Gate And Grills At Nts, Marcos, Nad, Chouldari Dam,porthrapur Filtration Plant, Dad Qtrs, Periera Enclave Under Age B/r Ii Of Ge Minnie Bay, Port Blair

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Systematicaly cleaning and desilting of pipe sewers of any type and upto 200 mm dia including man holes and gully trap of any size and depth by passing knots, bambboo, kamti and disc of required size, pumping out liquid waste/ sewage, plugging diverting the flow in the drain, if necessary and stacking the removed silt/ sludge in deposits as directed including taking precautionary measures such as safty belts, dry cells, torch for lighting in side the manholes and drain etc, sprinkling bleaching powder on the silt/ sludge removed to avoid bad smell and disposal of silt out side MD land complete all as specified and as directed by the Engineer-in-charge

350

-

-

... More
Cleaning of drains (open) including getting out depth up to 15 cm average of all vegetation, foreign materials, silt etc from drain complete all as specified and as directed by the Engineer-in-charge

500

-

-

... More
Cleaning of drains by destiling mud, vegetation, debries waste materials depositets etc, cleaning/removing manually/mechanically up to a depth of 60 cm and removing the materials outside md land complete all as specified and as directed by the Engineer-in-charge

50

-

-

... More
Cleaning carefully (with fresh water) the blockage in CI / PVC Pipe on walls & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M complete all as specified and as directed by the Engineer-in-charge

-

-

-

... More
(a) 75mm dia pipe

100

-

-

... More
(b) 110mm dia pipe

80

-

-

... More
Cutting hole carfefully behing wall of WC/IWC or kitchen bend/Tee of any dia in CI/PVC pipe to remove bend or trap and replace with new one sealing with solvent in joints of bend or trap and making good of cutting portion of wall with cement concrete 1:2:4 finished with rendering in CM 1:3 and finished with two coats of acrylic emulsion paint to match the existing surface to stop seepage and leakages including necessary scaffolding up to a height of 20.00 complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by the Engineer-in-charge

100

-

-

... More
Demolition of Precast Concrete work/ precast concreteblock built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed by the Engineer-in-charge

15

-

-

... More
M & L for Pre-cast cement concrete block masonry using PCC, Type C-2 solid blocks, exceeding 10 cm in width and setting in Cement Mortar 1:6, straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed by the Engineer-in-charge

15

-

-

... More
S & F weep holes pvc pipe 100 mm dia into block masonary complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
M&L for rendering 5mm thick in concrete or brick surface in CM 1:4 over 10 mm thick backing coat in CM 1:6 even & smooth without using extra cement complete all as specified and as directed by the Engineer-in-charge

245

-

-

... More
M&L for preparing newly plastered surfaces of wall and applying two or more coats if required of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and as directed by the Engineer-in-charge Make:Asian Paint Suprema ultima Note: Rate inclusive of scaffolding at any height

245

-

-

... More
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed by the Engineer-in-charge

18.8

-

-

... More
M & L for MS work such as fencing post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) Mild steel Angles, bars, flats etc., including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by the Engineer-in-charge

600

-

-

... More
S&F Framed work such as grills, gratings gates , etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed by the Engineer-in-charge

800

-

-

... More
M & L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes,riveted or welded Fe 290 (dge E-165) complete all as specified and as directed by the Engineer-in-charge

40

-

-

... More
S & F Mild steel screw bolts of 11 to 15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10 cm and not exceeding 15 cm complete all as specified and as directed by the Engineer-in-charge

40

-

-

... More
M & L for steel work in tubular tru-sses including special shaped washer etc. complete tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed by the Engineer-in-charge

400

-

-

... More
M&L for applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer on steel surfaces of any description, over 10 cm width or girth, not otherwise described including preparing new steel surfaces complete all as specified and as directed by the Engineer-in-charge

150

-

-

... More
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-charge

13

-

-

... More
M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in copings etc complete all as specified and as directed by the Engineer-in-charge

3

-

-

... More
M & L for PCC type C2 1:3:6 (40 mm graded agg)in surface channel and drain complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
M&L for plain cement concrete in foundations, filling and mass-concrete Type D2 1:4:8 (40 mm graded aggre-gate) complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
Demolition of reinforced Concrete in ground floors and pavings n exc 15 cm thickness complete all as specified and as directed by the Engineer-in-charge

3

-

-

... More
M&L for precast cover slab with 1:2:4 type B1 using 20mm graded stone aggregate incl cost of use and waste of clean sawn wooden form work but excl cost of reinforcement all as specified incl removal of existing unserviceable cover slab complete all as specified and as directed by the Engineer-in-charge

3

-

-

... More
M&L for TMT bars 10mm dia and over cut to length, bent to shape required incl cranking and hooking ends and binding with MS wire (annealed) of dia not less than 0.90mm complete all as specified and as directed by the Engineer-in-charge

400

-

-

... More
S & F in repairs Vitreous China Squatting Pan"Orissa pattern" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe)& Provision of concrete bedding and making good to floor complete all as specified and as directed by the Engineer-in-charge

4

-

-

... More
Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and as directed by the Engineer-in-charge

30

-

-

... More
Dismantling of Plain or Corrugated Steel sheeting of any gauge, thickness of roof in roof coverings, complete all as specified and as directed.

140

-

-

... More
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed by the Engineer-in-charge

120

-

-

... More
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley gutter, drip, and straight flashing complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F in repairs Aluminium wind ties for roof including all necessary drilling, bolting or rivetting fixed with GI self tapping screws as specified for roof sheeting complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F in repairs 3.5mm dia GI chain link fencing PVC coated 50mmx50mm mesh including fixing of MS flate iron,rod & bolt to fencing post complete all as specified and as directed by the Engineer-in-charge Note:MS flat,rod& bolts shall be measured and paid separately.

400

-

-

... More
Supply only mild steel screw bolts 10mm dia machine made with hexagonal or square head at one end and screwed the other or screwed both ends for fixing of chain link fencing complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
Supply only Mild Steel bars for support to chain link fencing complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
Supply only Mild Steel Flat iron as in fillets for securing wire mesh including all necessary drilling, bolting or riveting etc and similar work confirming to Fe-410-0 to Fe-310-0 complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
S & F in repairs galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S & F in repairs GI concentrina barbed tape wire fencing of dia exceeding 450 mm but not exceding 600 mm of coil when unstrectched to be provided on the top of compound wall not less than 6 (six) rounds per metre length of wall including clips as per manufacturer instructions complete all as specified and as directed by the Engineer-in-charge

200

-

-

... More
Taking down shrubs / vegetation growth from crevices completely, upto any height with all safety equipements complete all as specified and as directed by the Engineer-in-charge Note :- inclusive any height of scoffolding all as specified .

50

-

-

... More
Dismantling Floor, Hearth or Wall Tiling including cement mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris of the premises complete all as specified and as directed by the Engineer-in-charge

232

-

-

... More
M&L for chequered cement concrete tiles mixed with grey cement and no pigment of size 300x300 x22-25 mm thick set jointed and pointed in neat cement slurry in floors incl 20 mm thick screed in CM 1:4 complete all as specified and as directed by the Engineer-in-charge

50

-

-

... More
M & L for 300 x 300 x 8 - 10mm thick coloured vitrified heavy duty chequered tiles as in floor/wall set and jointed in cement slurry and pointed in coloured cement to match laid over 15mm thick cement mortar in CM 1:6 complete all as specified and as directed by the Engineer-in-charge

50

-

-

... More
M & L for PCC type D2 1:4:8 75 mm thick (40 mm graded agg) as in sub base complete all as specified and as directed by the Engineer-in-charge

100

-

-

... More
M & L for machine pressed precast concrete interlocking paver block glossy finish any shape & size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade complete all as specified and as directed by the Engineer-in-charge

100

-

-

... More
M & L for crushed sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by the Engineer-in-charge

4

-

-

... More
M & L for non Skid Ceramic Tiles, Coloured, of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 mm to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed by the Engineer-in-charge

40

-

-

... More
M & L for non skid Ceramic Tiles, Coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 mm to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed by the Engineer-in-charge

50

-

-

... More
M & L for glazed ceramic tiles, Coloured, of size 450X 300X 7 to 8mmmm thick as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 10mm thick in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-charge

42

-

-

... More
M&L for preparation of old plastered wall surfaces and applying one coat of acrylic wheather coat emulsion based premium quality matt finish exterior antifungal paint with one coat of primer as per manufacturer's instructionscomplete all as specified and as directed by the Engineer-in-charge

1000

-

-

... More
M & L for preparation of old wooden surfaces exc 10cm width and girth and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-charge

300

-

-

... More
M & L for preparation of old steel surfaces exc 10cm width and girth and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-charge

200

-

-

... More
M & L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed by the Engineer-in-charge

500

-

-

... More
M & L for preparation of old distempered surfaces of ceiling and applying one coat of oil bound distempercomplete all as specified and as directed by the Engineer-in-charge

100

-

-

... More
M&L for preparing new/old wall in side shaft surfaces for cleaning the fungi/algae growth by washing/scrubbing etc, including making arrangements for scaffolding and making good any damage/weak surfaces (plastering exceeding 0.5 Sqm shall be measured and paid in respective item) to match the existing surfaces and applying two coats of water proof elastomeric coating as per manufacturer's instructions complete all as specified and as directed by the Engineer-in-charge

50

-

-

... More
Taking down existing wash basins or kitchen sinks any size and type for repairs, refixing the same in position after necessary repairs / replacement of brackets with cement mortar 1:3 complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F in repairs 32mm waste coupling, brass, chromium plated for glazed ware sinks and basins etc, with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F in repairs 40mm wastecoupling, brass, chromium plated for glazed ware sinks and basins etc, with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
M&L in repair for chromium plated wall mixer with provision for both telephone shower and over head shower with 115mm long bend pipe and wall flange fixed complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S & F in repair Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated with crutch or butterfly handle, screwed down for iron pipe etc complete all as specified and as directed by the Engineer-in-charge

50

-

-

... More
Fixing only in repairs bib cock including cleaning, removing of air block/washer etc of any type and size complete all as specified and as directed by the Engineer-in-charge

25

-

-

... More
S & F in repairs Vitreous china wash hand basin, white, flat back of size 550 mm X 400 mm excluding pillar tap, and waste fittings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
Fixing only in repairs pillar taps including cleaning, removing of air block/washer etc of any type and size complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S & F in repairs Ball Brass Valve, 25 mm dia, high pressure, with polythene float and fly nut complete, screwed for iron pipe, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S & F in repairs Ball Brass Valve, 20 mm dia, high pressure, with polythene float and fly nut complete, screwed for iron pipe, cast copper alloy with crutch or butterfly handle screwed down or brass ferrule complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S&F in repairs angular cock cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
Fixing only in repairs angular cock including cleaning, removing of air block/washer etc of any type and size complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F in repairs stop valves cast copper alloy chromium plated fancy type screwed down high pressure screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
Fixing only in repairs stop cock including cleaning, removing of air block/washer etc of any type and size complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F in repairs stop valves cast copper alloy chromium plated with long shank and cup (concealed type) fancy type screwed down high pressure screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed .

20

-

-

... More
Fixing only in repairs concealed stop cock of any type and size after cleaning and removing of washer of blockage complete all as specified and as directed by the Engineer-in-charge

35

-

-

... More
S & F in repairs Vitreous China white Squatting Pan IWC of pattern long Pan of Size 580 mm 'P' or 'S' trap, front or back inlet and foot rests ( excluding cistern and flush pipe) including Provision of concrete bedding in 1:5:10 and making good to floor complete all as specified and as directed by the Engineer-in-charge

9

-

-

... More
Fixing only in repairs by replacing minor parts like flushing knob, float, screws etc of PVC flush tank low level cistern, 10 ltr capacity, including connecting to existing water supplyline and water closet pan complete.

20

-

-

... More
S&F in repairs gun metal gate valves with iron wheel head screwed both ends for iron pipe of dia 20mm complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S&F in repairs gun metal gate valves with iron wheel head screwed both ends for iron pipe of dia 25mm complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S&F PVC in repairs flexible connections 16mm size of length 450mm with, brass unions and rubber washers on either side for connecting water supply line to WHB, flush tank, etc., complete all as specified and as directed by the Engineer-in-charge

26

-

-

... More
S&F in repairs brass chromium plated shower rose with or without swivel joint 100mm size complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F in repairs PVC waste pipe 32mm dia for wash hand basin complete all as specified and as directed by the Engineer-in-charge

25

-

-

... More
S & F in repairs PVC waste Pipe of size 40 mm for sink complete all as specified and as directed by the Engineer-in-charge

15

-

-

... More
S & F in repairs 600 mm X 450 mm Mirror of selected quality glass, 5 mm thick, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
Taking out old unserviceable PVC Pipe of size 75mm , 110mm & 150mm from trenches and walls with all fittings incl necessary excavation,RFR and Removal upto 250 mtrs complete all as specified and as directed by the Engineer-in-charge

425

-

-

... More
S&F 150mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by the Engineer-in-charge

200

-

-

... More
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls complete all as specified and as directed by the Engineer-in-charge

40

-

-

... More
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls complete all as specified and as directed by the Engineer-in-charge

70

-

-

... More
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to floors complete all as specified and as directed by the Engineer-in-charge

45

-

-

... More
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to floors complete all as specified and as directed by the Engineer-in-charge

55

-

-

... More
Refixing old pipes after taking down any dia complete all as specified and as directed by the Engineer-in-charge

15

-

-

... More
S&F 75mm dia PVC (SWR) bend with oval access door complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F 110mm dia PVC (SWR) bend /shoe without oval access door complete all as specified and as directed by the Engineer-in-charge

30

-

-

... More
S&F 110mm dia PVC (SWR) branch piece (single Y)equal or unequal with oval access door complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F PVC (SWR) cowls 110mm dia complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F CI bend(any radius) 110mm bore of pipe diminishing pieces with oval access door complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F CI bend(any radius) 75mm bore of pipe diminishing pieces with oval access door complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F in repair CI branch pieces 110 mm ,single (equal or unequals)ordinary or inverted(spigot or socketed type)or with parallel branches with access door complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F in repair CI branch pieces 75mm ,single (equal or unequals)ordinary or inverted(spigot or socketed type)or with parallel branches with access door complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
Excavation in trenches in hard / dense soil n.exc. 1.5M wide and n.exc. 1.5M deep and getting out complete all as specified and as directed by the Engineer-in-charge

15

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and as directed by the Engineer-in-charge

12

-

-

... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m complete all as specified and as directed by the Engineer-in-charge

3

-

-

... More
S&F in repair PVC (SWR) floor trap,plain with grating 75/ mm with incl jointing with solvent cement complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S&F in repair PVC (SWR) floor trap,plain with grating 110 mm with incl jointing with solvent cement complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S&F in repair 75 mm PVC nahani trap with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S&F in repair 110 mm PVC nahani trap with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed by the Engineer-in-charge

5

-

-

... More
S & F in repairs PTMT Graiting square /rounded150 mm size [Minimum weight 100 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and as directed by the Engineer-in-charge

15

-

-

... More
S & F in repairs PTMT Graiting square /rounded100 mm size [Minimum weight 100 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and as directed by the Engineer-in-charge

15

-

-

... More
Taking down existing chowkats or frames n.exc. 1.5 Sqm each without taking off shutters from the frames complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of rudraksh colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and as directed by Engr-in-Charge

15

-

-

... More
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube in opeing,complete all as specified and as directed by the Engineer-in-charge

48

-

-

... More
S & F 75 mm size, medium weight Butt Hinges, cold rolled, Stainless steel including fixtures complete all as specified and as directed by the Engineer-in-charge

30

-

-

... More
S&F extruded aluminium alloy handle fabricated type anodised 100mm longcomplete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F in repairs PVC flush tank low level cistern, 10 ltr capacity, including connecting to existing water supply line and water closet pan complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
Taking up or down old/chocked water tubings 15mm bore with fittings from trenches /walls and stacking at site including cleaning for refixing in new or old position or credit to contractor complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
Taking up or down old/chocked water tubings 20 mm bore with fittings from trenches /walls and stacking at site including cleaning for refixing in new or old position or credit to contractor complete all as specified and as directed by the Engineer-in-charge

100

-

-

... More
Taking up or down old/chocked water tubings 25mm or 32 mm bore with fittings from trenches /walls and stacking at site including cleaning for refixing in new or old position or credit to contractor all as directed by Engineer-in-Charge.

120

-

-

... More
S&F 15 mm outer dia CPVC pipes of pressure rating 10kgf/cm2 fixed complete to walls ,ceiling s or in floors etc complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
All as per item no.117 here in before but 20 mm bore tube complete all as specified and as directed by the Engineer-in-charge

100

-

-

... More
All as per iitem no.117 here in before but 25 mm bore tube complete all as specified and as directed by the Engineer-in-charge

100

-

-

... More
All as per item no.117 here in before but 32 mm bore tube complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F 20mm outer dia CPVC pipes brass Elbow (3/4 X1/2) complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F 16 mm outer dia CPVC female brass adaptor (FTA/FBTA) complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F 20mm outer dia CPVC female brass adaptor (FTA/FBTA) complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F 25 mm outer dia CPVC female brass adaptor (FTA/FBTA) complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F 25 mm outer dia tank Adaptor complete all as specified and as directed by the Engineer-in-charge

20

-

-

... More
S&F 20mm outer dia union complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F 25 mm outer dia union complete all as specified and as directed by the Engineer-in-charge

15

-

-

... More
S&F 16 mm outer dia Brass Tee complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F 20 mm outer dia Brass Tee complete all as specified and as directed by the Engineer-in-charge

10

-

-

... More
S&F 25 mm outer dia Brass Tee complete all as specified and as directed by the Engineer-in-charge

15

-

-

... More
Cutting chases in concrete block walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-charge

60

-

-

... More
S&F in Repairs Vitreous Chaina Urinal, Half stall Long type of size 315x375x620 mm colour white incl urinal spearder pf PTMT of any colour for fixing with 15 mm dia pipe (minimum weighr 60 gms ) complete all as specified and as directed by the Engineer-in-charge

4

-

-

... More
M&L attending to petty repair job to plumbing/ internal water supply works such as repair to leaking bib taps/ pillar taps/ mixers/stop cocks/angle valves/concealed stop clock etc by tightening and providing washer, disc spindle or any other minor accessories, repair to float valves. Flushing cistern by minor adjustments, leaking water supply lines by tightening GI fittings or refixing water supply or sanitary fixtures using thread/Teflon tapes at site to make the system functional complete as specified and directed by Engineer-in-Charge. Note:-(a) Each repair Job shall be measured as one job. (b) Job involving replacement of taps/valves shall not be mearured under this item. (c) Contractor to provide one plumber with helper daily to report to JE (Civ) at 08:30 hrs for detailment of duty complaints and resubmit complaints slip to JE (Civ) in the evening at 05:00 PM on daily basis. (d) For non providing plumber recovery @ Rs. 100.00 per hour with maximum Rs. 800/day.

700

-

-

... More
M&L for prepration of old painted surfaces and applying one coat of synthetic enamal(Ordinery tint ) paint on road kerb serfaces / concrete surfaces of any description over 10 cm girth or width not otherwise described complete all as specified and as directed by the Engineer-in-charge

130

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.