Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Sep 2024
Closing Date21 Oct 2024
Tender Amount₹ 39,00,000
Costs
EMD
₹ 78,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676182_1Bid Award Id
ViewTender No
8902/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Compressor for window/split type AC of capacity 1.5 TR
8
-
-
Compressor for window/split type AC of capacity 2/2.5 TR
16
-
-
Compressor for window/split type AC of capacity 3.0TR/3.5 TR (Vertical/Cassette type)
8
-
-
Compressor for refrigerator of capacity 165 to 180 ltr
4
-
-
Compressor for refrigerator of capacity 285/310 ltr
4
-
-
Compressor for water coller of capacity 40/80 ltr
8
-
-
Taking down unserviceable/damaged wall mounted copper cooling coil unit of split type AC (Inverter or reguar type) complete by means of disconnecting elecrical connection and suction and discharge pipe line and S&F new cooling coil unit of suitable capacity of existing (dismantled) model or equvialent make approved by Engineer-in-charge including remote control, proper fixing on wall, connecting to electrical system, suction and discharge pipe line, drain water pipe line all as directed, commissiong and testing complete for satisfactory performance of unit after gas charging of following capacity including transportation. Note:- Before taking down the unit the gas shall be stored in a container for refilling, additional gas (if requried) shall be measured and paid separately under respective items of this schedule
-
-
-
Suitable for split type AC of capacity 1.5 TR, 230 Volt AC
4
-
-
Suitable for Split type AC of capacity 2 TR, 230 Volt AC
10
-
-
Taking down unserviceable/damaged/rusted condenser unit of split type AC (Inverter/regular type) complete by means of disconnecting electrical connection, suction and discharge pipe line and S&F new condenser unit consisting of body, motor, condenser & blade suited for exisitng (dismantled) model or equivalent make approved by Engr-in-Charge, connecting to suciton and discharge pipe line to compressor after refixing compressor of existing unit all as directed, commissioning and testing complete for satisfactoroy performance of unit after Gas charging of following capacity including 14 RM suction and discharge copper pipe of adequate size with insulation. Note : Before taking down the unit the gas shall be stored in a container for refilling, additional gas (if required) shall be measured and paid separtely under respective items of this schedule
-
-
-
Suitable for 1.5 TR capacity
4
-
-
Suitable for 2 TR capacity
10
-
-
M&L Servicing of window type AC 1.5/2 TR capacity including leak testing with nitrogen gas, dehydrating/vaccumising, leak arresting, flaring, brazing and replacing of filter, cleaning and washing with causitc soda to condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to motor, painting to base tray and outer cover with two coat of synthetic enamel paint, including transportation, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
30
-
-
M&L Servicing of indoor & outdoor unit of split type AC 1.5/2 TR capacity including leak testing, leak arresting, brazing and replacing the filter after that cleaning/washing with caustic soda to condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to motor, painting to base tray with two coast of syntheic enamelled paint, including taking out and refixing the machine at its original location including transportaiton, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
50
-
-
M&L Servicing of Indoor & Outdoor unit of vertical type AC 3.5/3 TR capacity including leak testing between indoor and outdoor unit pipe line, leak arresting, brazing, and replacing the filter after that cleaning/washing with caustic soda to condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to motor, painting to base tray with two coast synthetic enamelled paint, including taking out and refixing the machine at its original location including transportation, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
8
-
-
M&L Servicing of indoor & outdoor of cassette type AC of any capacity disconnecting the indoor and outdoor unit of 3.0 TR capacity including leak testing between indoor and outdoor unit pipe line, leak arresting brazing, and replacing the filter after that cleaning/washing with caustic soda to condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to motor, painting to base tray with two coat of synthetic enamelled paint, including taking out and refixing the machine at its original localion including transportation, connecting of all electrical connections, testing & commissiong complete all as specified and directed.
3
-
-
M&L Servicing to water cooler of any capacity after disconnecting the water cooler from electric and water supply, cleaning/washing the condenser unit with use of Caustic Soda, cleaning the condenser coil, greasing the fan motor, checking/repairing the electric wiring thoroughly, cleaning of water storage tank, replacement of push cock washer, applying one coat of synthetic enamelled paint in basement area housing compressor & condenser and fan motor all as directed by Engineer-in charge including writing SM No with capacity in redium stickers, date of servicing and CA No. in 30 mm size letters with black paint. Note for Item No 06 to 10: 1 :The rate quoted including cutting, welding, brazing, and de-scaling refrigerant tubing. 2 : Spares shall be measured and paid separately.
14
-
-
Taking out old/burnt selector switch and S & F new selector switch for window type AC of capacity as per requirement
12
-
-
Taking out old/burnt blower motor and supply and fixing blower motor double shaft, single/double speed, single phase, AC, 230 V non inverter type (OEM approved) for the following capacity (as per sample) all as directed
-
-
-
1/4 HP
3
-
-
1/5 HP
2
-
-
1/6 HP
3
-
-
Taking out old unserviceable fan blade and S & F new fan blade for window/split/tower type AC of any capacity.
10
-
-
Taking out of old/burnt blower motor, 230V and S&F new blower motor 230 V for indoor unit of split AC inverter tyoe of any capacity.
4
-
-
M & L for replacement of unserviceable remote control with PC board complete suitable for existing model of window type/split type/tower type of any capacity regular type (OEM approved make).
5
-
-
Material and labour for replacement of unserviceable PC board complete suitable for existing model of window type/split type/tower type/inverter type AC of any capacity (OEM approved make).
9
-
-
Material and labour for replacement of unserviceable remote control suitable for existing model of window type/split type/tower type/inverter type AC of any capacity (OEM approved make).
12
-
-
Material and labour for replacement fan motor capacitor of following capacities.
-
-
-
4 MFD
20
-
-
6 MFD
20
-
-
10 MFD
20
-
-
Material and labour for replacement of power contactor ML-3 type, heavy duty, three pole 415 Volt AC.45 Amps (AC1 rating) capacity with auxiliary contactor of (2 No + 2 NC) with coil voltage comple all as specified and as directed
2
-
-
Material and labour for replacement of power contactor ML-1.5 type, heavy duty, three pole 415 Volt AC.45 Amps (AC1 rating) capacity with auxiliary contactor of (2 No + 2 NC) with coil voltage comple all as specified and as directed
2
-
-
Material and labour for replacement of bi-metal overload relay, direct mounting type suitable for ML series contractor of range 13-21 Amps/20-32 Amps Make : L&T type, ML or equivalent make in GE/Siemens
2
-
-
Material and labour for replacement of electronic timer, type ET -100,230 volt AC complete all as specified and as directed
2
-
-
Material and labour for replacement of single phase preventer model VSP - 1. Make : Minitec or equivalent model of approved make specified in appendix "B" to particular specification
4
-
-
Supply only Refrigerent gas in manufacturer sealed cylinder of following type:-
-
-
-
Supply only Refrigerent gas R-22/32 in manufactures sealed cylinder.
220
-
-
Supply only Refrigerent gas R-410/404/401a in manufactures sealed cylinder.
50
-
-
Supply & fixing in repair RO Membrane filter as per existing make & model
6
-
-
Taking down old unserviceble outdoor unit fan motor of capacity 11.5 TR air conditioner plant and supply & fix new fan motor of capacity 250 volts, 50 Hz, AC supply complete.
4
-
-
Material and labour for replacement of new cooling coil unit suitable for Refrigerator of capacity 165 to 180 Lts.
4
-
-
Material and labour for replacement of new cooling coil unit suitable for Refrigerator of capacity 285 to 310 Lts.
4
-
-
Material and labour for replacement of magnetic door panel gasket complete suitable for existing model of refrigerator of capacity 165 to 180 Lts including taking out of broken/unserviceable old existing one.
2
-
-
Material and labour for replacement of magnetic door panel gasket complete suitabel for existing model of refrigerator of capacity 285 to 310 Lts.
2
-
-
Taking out old unserviceable thermostat and Supply & Fix new thermostat of approved make and suitable size & model for the following.
-
-
-
Thermostat No 2059 with knob for window type AC
7
-
-
Auto 'D' themostat No 1027 with knob for refrigerator
6
-
-
Thermostat No 2064 with knob for water cooler
6
-
-
Taking out old unserviceable potential box type relay and supply & Fix new potential box relay/PTC relay of suitable model for window/split type AC capacity 1.5/2.0 TR
10
-
-
Taking out old unserviceable OLP - 1622 and Supply & Fix new OLP - 1622 relay for window type AC.
5
-
-
Taking out old/burnt starting capacitor/running capacitor and supply & Fix new starting capacitor of following capacities:-
-
-
-
Upto 36 MFD
30
-
-
40 MFD to 60 MFD
30
-
-
Material and labour for replacement of 3 core, 2.5 sqmm, copper conductor PVC insulated flexible cabel from main supply point to outdoor unit point as directed any specified by Engineer-in-charge.
80
-
-
Material and labour for replacement of 15mm bore PTMT float valve for water cooler of any capacity complete all as specified and as directed
10
-
-
Material and labour for replacement of PVC flexible pipe 600 mm long complete for water cooler of any capacity complete all as specified and as directed.
10
-
-
Supply & fixing in repair carbon filter as per existing make & model
10
-
-
Supply & fixing in repair sediment filter as per existing make & model
6
-
-
Supply & Fix of Starter switch of capacity 25 amps, working on 240 volts AC supply, for air conditioner. Make : (Crabtree: Cat Part No. ACTO252504.
18
-
-
Supply & Fix in repair of exisiting microprocessor based ARTIC controlled board and fixed with new ARTIC board including suitabel sensor for window/split/tower/cassetter/Inverter type AC working on 415/230 volts, 50Hz all as directed.
30
-
-
Material and labour for insulation material of suitable size in repair to cover the indoor and outdoor unit of piping connection with suitable clamping all as directed.
110
-
-
Supply & Fix powder coated brackets of suitable for fixing of outdoor unit all as directed.
44
-
-
Material and labour for replacement of old/burnt out condenser fan motor, single shaft upto 40W capacity single phase, 230V AC for water cooler.
12
-
-
Material and labour for Replacement of unserviceable push cock,15 mm dia brass chromium plated for water
8
-
-
Supply & Fix in repair fan blade for water cooler of any capacity.
6
-
-
Material and labour for replacement of copper tubing, confirming to relevant IS of following sizes.
-
-
-
5/8" flare size.
100
-
-
1/2" flare size.
100
-
-
3/8" flare size.
100
-
-
1/4" flare size.
100
-
-
Supply & Fix in replacement of sheet metal enclosure with socket plug top & MCB single pole and Neutral enclosure with two pin and earth plug & socket complete with one single pole MCB 20 Amps complete all as specified and directed.
8
-
-
M&L for repairs to voltage stabilizer automatic opertion single phase of various make & capacity (0.5 to 5 KVA) by dismantling / opening the stabilizer for checking the parts/components, circuit for proper functioning, cleaning inside the stabilizer, replacement of defective minor itmes i.e screws, lugs, cut out/fuses, reset switches, rubber packing etc.re assembling the stabilizer testing on rated equipment load for automatic operation to stabilizer standard out put voltage, all as specified and directed by Engr-in-Charge Note:(i) Any spare part of stabilizer if found defective will be measured as supply and fix in repairs under respective item of this Schedule 'A' (ii) Cost of spare parts shall be included in the unit quoted rate
14
-
-
Supply and fix in repair electronic circuit card (PCB) suitabel for automatic single phase stabilizer 5KVA capacity of various make with high & low voltage cutout device but excluding ICS, as directed by Engr-in-Charge.
16
-
-
All as per item No 50 above but suitable for 4 KVA capacity stabilizer
16
-
-
Supply and fix in repair main transformer made from super enameled, copper wound conductor suitable for existing various make single phase stabilizer of capacity 5/4 KVA as specified & directed by Engr-in-Charge.
16
-
-
M&L for leak testing with nitrogen gas of window type AC 1.50/2 TR capacity including, dehydrating/vaccumising, leak arresting, flaring, brazing and taking out and refixing the machine at its original location including transportation, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
26
-
-
M&L for leak testing with nitrogen gas of Split type AC Upto 2.5 TR capacity including, dehydrating/vaccumising, leak arresting, flaring, brazing and taking out and refixing the machine at its original location including transportation, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
49
-
-
M & L for testing with nitrogen gas of vertical type AC upto 4.0 TR capacity including, dehydrating/ vaccumising, leack arresting, flaring, brazing and taking out and refixing the machine at its original location including transportation, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
8
-
-
Taking down old unserviceable and S & F for PVC Conduit pipe of size 20mm dia including fittings all as specified and directed.
100
-
-
Taking down old unserviceable and S & F for PVC Conduit pipe of size 40mm dia including fittings all as specified and directed.
16
-
-
Evaluation Notes How It Works ?