Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Aerospace and Defence
Eprocure
Opening Date27 Aug 2022
Closing Date30 Sep 2022
Tender Amount₹ 2,44,00,000
Costs
EMD
₹ 3,19,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_548121_1Bid Award Id
ViewTender No
80253 / E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Excavation over areas not exceeding 1.50 m in depth and getting out in Hard / Dense soil complete all as specified and as directed.
724
-
-
... More
Excavation over areas exceeding 1.50 m and not exceeding 3.00 m in depth and getting out in Hard / Dense soil complete all as specified and as directed.
95
-
-
... More
M & L for Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled with power road roller of 8 to 12 ton capacity and consolidated to required gradient and camber complete all as specified.
295
-
-
... More
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
61
-
-
... More
M & L for RCC M–30 Design Mix, using 20mm graded stone aggregate as in foundations including Pile Caps, Rafts, Footings, Foundation Beams, Plinth Beams, Bases for Columns etc. complete all as specified and as directed.
371
-
-
... More
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts etc. and embankments complete all as specified and as directed.
47
-
-
... More
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
74800
-
-
... More
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
1375
-
-
... More
Use and removal of steel formwork to sides of concrete foundations, pile caps, footings, bases of columns, raft and raft beams, sides and soffits [if any] of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed.
242
-
-
... More
Use and removal of steel formwork to sides of pillars, posts, struts, piers, columns and stanchions of any shape / cross section for fair finished surfaces of concrete complete all as specified and as directed.
117
-
-
... More
S & F UPVC Pipe of 150 mm bore [SCH-80] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, sockets etc and fixed to walls, ceiling, and laid on floors or in trenches including testing complete all as specified and as directed.
120
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
754
-
-
... More
Removal of excavated material [Soil] to a distance exceeding 250m and not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
777
-
-
... More
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
81
-
-
... More
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150 mm dia of pipe complete all as specified and as directed.
4
-
-
... More
M & L for Moorum / Red Bajri filling under Floors or in Pavings laid in layers not exceeding 15 cm thick, spread levelled and rammed / rolled with power road roller of 8 to 12 ton capacity including watering to and consolidated to required level, gradient and camber required complete all as specified and as directed. Note: Measurements shall be taken after consolidation of earth and 10% deduction shall be made for payments.
60
-
-
... More
M & L for preparation of Bituminous / Concrete surfaces of Taxiway, Turning Pads, Runway surfaces by removing all dirt, scales, oil grease and foreign materials etc. and Painting Lines, Dashes, Arrows, Letters, etc. and the like exceeding 10cm width or girth with Two Coats of Water based Acrylic Runway Marking Paint of colour White or Golden Yellow [Retro Reflective Type] with White or Black Borders, Cold applied type, applied by skilled painter / applicator complete all as specified and as directed.
300
-
-
... More
M & L for preparing newly plastered / concrete Wall / Ceiling surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on Wall / Ceiling surfaces complete all as specified and as directed.
200
-
-
... More
M & L for applying Two coats of Epoxy Concrete Floor Coating [Consisting of Resin & Hardener] [Dark Grey Colour] by using stiff brushes and/or rollers over a coat of Epoxy Primer on concrete surfaces for creating bonding between Epoxy coating and concrete surfaces including preparation of surfaces, removing all undulations with wire brush or electric floor scrubber or etching with suitable tools, pressure cleaning the surface with clean water and finally cleaning the surface with industrial vaccume cleaner to remove all foreign matter, dust and debris etc. including filling the cracks if any / air voids with suitable Epoxy Grout, finishing the surface to even and plain surface using suitable means to remove all imperfections and entrapped air complete all as specified as directed and as per manufacturer’s instructions.
678
-
-
... More
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 95 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed. Note: The rate quoted deemed to be inclusive of Cable Jointing Kits required for terminations.
1350
-
-
... More
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 70 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed. Note: The rate quoted deemed to be inclusive of Cable Jointing Kits required for terminations.
2800
-
-
... More
Supply and laying of DWC [Double Wall Corrugated] HDPE Pipe and including fittings such as couplers, bends, end caps etc., ISI marked of outer dia of 63mm and inner dia 50mm polyethylene with smooth internal and profiled external surface for non pressure under ground cable complete all as specified.
4000
-
-
... More
M & L Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
16
-
-
... More
Supplying and laying GI pipe, 40mm dia, Light grade including all fittings for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
100
-
-
... More
Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 100 Amps rating TPN bus bars of high conductivity Aluminium Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 55. The panel shall be fixed with angle iron frame made of angles of size 75 X 75 X 8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following:
[a] MCCB, 63 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Incoming]
[b] MCCB, 40 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 2 Nos [Outgoing]
[c] Multi Function Meter, Digital Type [Displaying A, V, PF, Hz, KVA, KW, KVAR, KWH, KVARH etc. Class 1.0] with CTs & Selector Switch – 1 Set
[d] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set.
4
-
-
... More
Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 100 Amps rating TPN bus bars of high conductivity Aluminium Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 55. The panel shall be fixed with angle iron frame made of angles of size 75 X 75 X 8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following:
[a] MCCB, 40 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Incoming]
[b] MCCB, 32 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Outgoing]
[c] MCB, 16 Amps, SPN, 10 KA, 240 Volts, AC, 50 Hz, B Curve – 1 Nos [Outgoing]
[d] Multi Function Meter, Digital Type [Displaying A, V, PF, Hz, KVA, KW, KVAR, KWH, KVARH etc. Class 1.0] with CTs & Selector Switch – 1 Set
[e] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set.
4
-
-