Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date21 Feb 2024
Closing Date11 Mar 2024
Tender Amount₹ 44,00,000
Costs
EMD
₹ 88,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_643457_1Bid Award Id
ViewTender No
8451ATender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling wall and ceiling board fibre, pulp insulation etc or insulation boards any thickness including cover fillets complete all as specified .
40
-
-
Demolition of PCC Block wall built in cement mortar or lime mortar complete of any description all as specified and directed.
2
-
-
M&L Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) all as specified.
4.5
-
-
S&F GI frame work for PVC Wall Paneling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm fixed to wall at approx 900mm centre to centre with Gleat and steel expansion fasteners with and including wall section of 0.55 mm thickness having kurled web of 50 mm and flange of 28 mm each with PVC sheet of 1.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre fixed with joining for ‘J’ trim & ‘T’ Section including hanging of 6 mm dia GI (upto 1200 mm length) adjusting level finished to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and as directed
40
-
-
M&L for 100 mm thick PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in sub bases,
32
-
-
M&L for 25mm thk PCC 1:2:4 type B-0 using 12.5 mm graded agg as in flooring finished fair and even without using extra cement.
250
-
-
M&L Virified tiles 10 mm thick (square/ rectangular) any shade polished, area of each tiles exceeding 0.42sqm and not exceeding 1.00sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15 mm thick in Cement mortor 1:4 for laying floor finishes.
250
-
-
M&L Virified tiles 10 mm thick (square/ rectangular) any shade polished, area of each tiles exceeding 0.42sqm and not exceeding 1.00sqm, in wall surfaces(skirting/daddo) set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 10 mm thick in Cement mortor 1:4 all as specified and directed.
100
-
-
M&L Rendering 10mm thick on internal sides wall of Brick / Concrete Surfaces in CM (1:6) finished even & smooth without using extra cement.
50
-
-
M&L Rendering 15mm thick on sides of wall of Brick / Concrete Surfaces in CM (1:6) with level plast including 3 to 5% of water proofing compound finished even & smooth without using extra cement.( Note Waterproofing compound and level plast paid separately) Complete all as specified and directed.
50
-
-
Supply only integral WPC
12
-
-
M&L Rendering 10mm thick on concrete surfaces such as sofit of slab, chajja etc in CM (1:3) finished even & smooth without using extra cement.
15
-
-
Materials and labour for Preparation of New plastered surfaces of walls and applying two coats of Plastic emulsion paint over a coat of primer complete all as specified and as directed .
50
-
-
Materials and labour for complete removal of existing treatment on walls and applying one coat of Putty to make the wall surface in plumb line and applying two coats of Plastic emulsion paint over a coat of primer complete all as specified and as directed .
130
-
-
Preparation of old external surfaces of walls, Facias, cornices etc and applying one coat of weather proof anti fungal paint (Apex - ultima) on coat of external wall putty on walls all as per manufacturer instruction and as directed by Engineer-in-Charge.
50
-
-
M& L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima)
20
-
-
Taking down chowkats or frames exceeding exc 1.5 sqm but n exc 4 sqm each (Without taking off shutters & Grill from the frame).
2
-
-
S & F Aluminium anodised (minimum anodisation is 15 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco).
(Note:- Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only).
100
-
-
Supply only 4.0mm thick Sheet glass ordinary quality and glazing with oil putty in Square nexc 0.5sqm in each panel.
10
-
-
M&L for 12 mm thick prelaminated particle board to fixed in repair interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work.
2
-
-
S&F 100 Butt hinges extruded aluminium alloy, anodised. With galvanished mild steel hinge pin anodised and fixed type B-21
3
-
-
S&F 200mm Aluminium anodised barrel tower bolts of extruded sections.
6
-
-
S&F 150mm Extruded aluminium alloy handles, fabricated type, anodised.
6
-
-
Taking up or down, 25mm dia bore, GI tubing, medium grade, including cleaning for refixing or removing from site, complete all as specified and as directed by Engineer-in-Charge.
20
-
-
Taking up or down, 20mm dia bore, GI tubing, medium grade, including cleaning for refixing or removing from site, complete all as specified and as directed by Engineer-in-Charge.
10
-
-
S&F of Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe fittings fixed to walls and ceilings or laid in floors complete all as specified.(a) Outer diameter of pipe in 20 mm
30
-
-
All as per item no 29.00 here in before but for Outer diameter of pipe in 25 mm
10
-
-
S & F in repairs1000 litres capacity Rotational moulded polythene water storage tanks(cylindrical vertical with closed top) hoisted in position all as specified in SSR Part I
1
-
-
S&F inrepairs 15mm Bore Stop Valves / Angular cock with wall flange chrome kubix prime Make: Jaquar Cat Code No KUP-CHR-35053PM.
10
-
-
S&F inrepairs 15mm Bore Stop Valves / Angular cock with wall flange chrome kubix prime Make: Jaquar Cat Code No QQT 7053.
10
-
-
S&F in repairs two way bib tap with wall Flange Make: Jaquar Cat Part NO QQT 7041 screwed down screwed for iron pipe or brass ferule etc complete all as specified and as directed by Engineer-in-Charge.
6
-
-
S&F in Repair 6mm thickness looking mirror bevelled Edge mounted on bracket as necessary brequirement with chromium plated brass screws and cup washers complete all as specified and directed by the Engineer -in- charge..
6
-
-
S&F in repairs Gun Metal Gate valves 20 mm dia with iron wheel head screwed both ends for iron pipes.
6
-
-
S&F in repairs Chromium Plated Steel Grating of Jaquar Square Shape Body Shower, For Bathroom, Model Name/Number: Make: Jaquar Cat code no BSH-CHR-1751
9
-
-
S & F in Repairs Hand Shower (Health Faucet) with 8mm Dia 1.2 Meter Long Flexible Tube and Wall Hook Make: Jaquar Cat code No ALD-CHR-573 Complete all as specified and directed
6
-
-
Supply and fix vitreous china CASCADE type WC single piece-WC with PP seat Cover, hinges, fixing accessories set, cistern fittings complete of size 640 x 360 x 690 mm , P trap-180mm in approved colour all as specified and directed as per ISI mark. Make : Jaguar cat Part No. SLS-WHT-6851P or equivalent .
5
-
-
S & F in Repairs Bib Cock Make: Jaquar Cat Code no QQT 7073 complete all as specified and directed.
5
-
-
S&F in repair Oval shape vitreous china white thin Rim table top basin of size 500x380x120mm with 32mm waste coupling brass chromium plated suitable for wash hand basins all as specified and directed by Enge-in-Charge.
Make: Jaquar Cat code No JDS-WHT-25937
6
-
-
S & F in Repairs Bottle trap 32mm dia Make: Jaquar Cat code No ALD 769L250X190 complete all as specified and directed
8
-
-
S&F in repairs SS Towel holder all as specified. Make: Jaquar cat code no. AQN7711
6
-
-
S & F in Repair corner Glass Shelf with Bracket all as specified and directed Make: Jaquar Cat ACN 1173
6
-
-
S & F in Repair Towel Ring Round Complte all as specified and directed.
Make: Jaquar Cat AQN 7721
6
-
-
Supply and fix brass CP 15mm dia bore Central hole basin mixer with regular spout without popup waste system with 450mm long braided hoses, 20mm cartridge size also available complete all as specified and as directed by Engineer-in-Charge. Make: Jaquar cat Part No.FLR-5167NB
6
-
-
S&F in repairs PVC flexible connections 15 mm dia 450 mm long with brass checknuts .
14
-
-
S&F in Repair Jaguar Toilet Paper Holder Make: Jaquar Cat Part No AQN 7751 all as specified and directed by Engineer in charge. .
6
-
-
S&F in Repair Jaguar Glass Shelf 550mm long Make: Jaquar Cat Part No AQN 7771 all as specified and directed by Engineer in charge. .
6
-
-
Supply and fix in repairs brass CP 15mm dia bore wall mixer 3-in-1 system with provision for both hand shower and overhead complete with 115mm long bend pipe, connecting legs & wall flange (without) hand & overhead shower) complete all as specified and as directed by Engineer-in-Charge. Make: Jaquar cat Part No.FLR-5281N or equivalent
6
-
-
S&F in Repair 20mm thick marble tiles machine cut in skirting/dado/ Cooking Plate form / Table Top laid over cement screed and jointed with grey cement slurry including cutting and polishing of type all as specified and directed by Engineer in charge. ( Note :- Colour/ Shade is finalized by GE)
6
-
-
S&F in repairs PVC flexible connections 15 mm dia 450 mm long with brass checknuts .
19
-
-
Taking down PVC waste ,vent,rain water pipes incl fittings in any position
50
-
-
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls
6
-
-
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,laid in floor.
16
-
-
S&F 75mm dia outlet PVC (SWR) PVC (SWR) multi floor trap with grating including jointing with solvent cement
15
-
-
S&F PVC (SWR) Gully trap 125/110 mm,seting and incl joining with solvent cement
10
-
-
S&F 110mm PVC (SWR) WC connector bent type setting including Joining with solvent cement
10
-
-
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls
8
-
-
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,laid in floors.
20
-
-
S&F 75mm dia PVC (SWR) bend with oval access door
2
-
-
S&F 110mm dia PVC (SWR) bend with oval access door
2
-
-
S&F PVC (SWR) cowls 110mm dia.
4
-
-
S&F PVC (SWR) cowls 75mm dia.
4
-
-
M&L for precast man holes cover slab with 1:2:4 type B1 using 20mm graded stone aggregate set in CM 1:4 incl cost of use and waste of clean sawn wooden form work but excl cost of reinforcement all as specified
0.4
-
-
M&L PCC 1:3:6 type B1 using 20mm graded stone aggregate as in surface channel / benching incl cost of use and waste of clean sawn wooden form work all as specified
0.1
-
-
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-ted/stoped ends etc
10
-
-
M&L for 20mm thick Granite of any type work table rubbed and polished in steps, jambs , pillars, cooking platforms and the like including pointing with white cement 1:2 using marble dust with admixture of pigment to match with shade of granite including Screed bed of coat 20mm thick CM (1:4) complete
2
-
-
M & L for RCC- M -30 Design Mix as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in,shelves and the likeall as specified and directed
0.5
-
-
Use and waste of form work to sides and sofit of Roof Slab & Chajja etc for Fair finished surfaces.
8
-
-
TMT bars 10 mm dia and over cut to length bent to shape required and binding with mild steel wire annealed not less than 0.9 mm dia
50
-
-
Dismantling of stone slabs and tiles of any description or thickness in floors, approns and laid bedded and pointed in any mortar etc.
3.5
-
-
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for slab,shelves etc complete all as specified and directed
3.5
-
-
Demolition of Concrete of any description and in any position complete all as specified and as directed.
25
-
-
M&L 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 finsihed the surfaces even and smooth without using extra cement.
9
-
-
Extra for forming fair finished drain or channel 80 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed
114
-
-
M&L rendering 15 mm thick cement plaster in cement mortar 1:3 on fair faces of brickwork or concrete surfaces finished fair and even complete all as specified and directed
50
-
-
M&L for 20mm thick Screed bed or bedding layer of Cement mortar 1:3 for laying floor finishes complete all as specified and directed.
50
-
-
M&L 20 x 20 x 4mm thick Glass mosaic tile flooring of any pattern as approved in fountain over 6mm thick Dr Fixit Cementious tile adhesive(C2 T Highly deformable) for tiles over two coats of Dr fixit Fast flex water proofing coating over two coats of URP coating in ratio to cement of (1:1.5 by weight) on fair faces of screed base including sealing of joints using water resistant tile grout in water to powder ratio (1:2.5 by volume) of Dr fixit all as per manufacturers instruction complete all as specified and directed.
Make : Italia Glass mosaic (Vitro)
52
-
-
M&L 20 x 20 x 4mm thick Glass mosaic tile in vertical surface of walls of any pattern as approved in fountain over 6mm thick Dr Fixit Cementious tile adhesive(C2 T Highly deformable) for tiles over two coats of Dr Fixit Fast flex water proofing coating over two coats of URP coating in ratio to cement of (1:1.5 by weight) on fair faces of plaster including sealing of joints using water resistant tile grout in water to powder ratio (1:2.5 by volume) of Dr Fixit all as per manufacturers instruction complete all as specified and directed.
Make :Italia Glass Mosaic (Vitro)
57
-
-
M&L Mild steel corrosion resistant TMT bars 10mm dia and over cut to length, bent to shape required including cranking and bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia) or securing with clips complete.
541
-
-
M &L for precast manhole covers with plain faces using RCC 1:2:4 type B1 and set in CM 1:4 including formwork.
3.5
-
-
M&L 40 mm thk cement concrete type B1, 1:2:4 (using 20mm graded aggregate) as in floors complete all as specified and directed.
635
-
-
M&L Maxgrip tiles for ramps & wet areas of size 400x 400 x 10 mm/ 600 x 600 x 10 mm in floor etc,set and jointed in neat cement sluryy and pointed in coloured cement to match as in floor over 15mm thick screed bed in CM (1:6) all as specified.
600
-
-
M&L Granite (of any type) tiles 18 - 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes all as specified and directed
35
-
-
Taking down carefully copper point wiring (light, fan, socket or power) DBs complete offering credit, making good disturbed surfaces of walls, floors, etc, all as specified and as directed.
80
-
-
M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including concealed pvc conduit, fixed on wall / ceiling with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified.(a) One light point controlled by one switch
46
-
-
One exhaust fan point controlled by one switch
6
-
-
One fan point controlled by one switch and one regulator
8
-
-
One 3 pin switch socket outlet point 5 amps on independent board
16
-
-
All as per item No 87.00 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed.
4
-
-
Supply and fixing Modular switch 1 way 5 A, 1 module all as specified and directed.
76
-
-
Supply and fixing Modular switch 1 way 15 A, 1 module all as specified and directed.
4
-
-
Supply and fixing Modular Bell push 5A, 1 module all as specified and directed.
2
-
-
Supply and fixing modular socket outlet, 2/3 pin combined , 6 Amps, 2 module, 230 volts all as specified and directed.
16
-
-
Supply and fixing modular socket outlet, 2/3 pin combined , 6/16 Amps, 2 module, 230 volts all as specified and directed.
4
-
-
Supply and fixing modular fan step regulator, 230 V, AC, 120W - 2 module
8
-
-
Taking down serviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site with new clamps, nuts, washers, safety wire of size not less than 1.00mm & bolts including cotter pin for complete all as directed.
8
-
-
Taking down serviceable exhaust 300 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades complete and refixing back at site with new clamps, nuts, washers & bolts complete all as directed.
6
-
-
S & F Single pole and neutral metal enclosure with 2 pin and earth plug and socket and top plug complete with 20 Amps MCB SP , 240 Volt all as specified and as directed
4
-
-
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, double door suitable for mounting MCBs including taking down old MCB/DB complete all as specified and directed.
Note-: Incoming & outgoing connections from the DB shall be provided with proper lugs/ thimbles etc
4
-
-
Supply and fix in repair sheet metal enclosure Loadline distribution vertical DB, MCCB as incomer 4 ways 415 volts, with 200 amps rated bus bar double door suitable for mounting MCCB 100 A TPN as incomer and MCBs as outgoing, Triple pole as incoming complete all as specified and directed including taking down old MCB DBs complete.Thye Rate shall be included the incomer MCCB TPN of 100 Amps
Note-: Incoming & outgoing connections from the DB shall be provided with proper lugs/ thimbles etc
1
-
-
Supply and fix in repair MCB single pole 240 volts, 6 to 32 amps "B" series complete all as specified and as directed by Engineer-in-Charge
24
-
-
Supply and fix single pole and netural 240 Volts 32 amps complete all as specified and as directed by Engineer-in-Charge
2
-
-
Supply and fixing energy efficient aluminium housing LED Smart bright batten 22 /20 Watt mounted batten fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
26
-
-
Supply and fix LED lamp of 9/10 watt all as speciifed and dircted
4
-
-
Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
4
-
-
S & F LED Wall light 20 Watt, white colour provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable wall light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
6
-
-
S & F LED Bed side1 x 2 Watt, Bronze Metal Synthetic provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, including taking down old unserviceable bed light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
2
-
-
S&F 25 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
4
-
-
M & L in repairs for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of casing caping & one run of earth continuity conductor shall be measured as one running metre.
80
-
-
All as per item no 111.00 here in before but wiring of size 4 sqmm complete all as specified and directed.
122
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
2
-
-
supply & Lay XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 25 Sqmm 3.5 Core in trenches/along the wall/including making all connections, saddles, spacers including scaffolding if any required for saddling the cable in walls of building of height up to 25 meter, complete with aluminium lugs as required at site and as directed by Engr-in-Charge
120
-
-
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out Soft/loose Soil
24
-
-
Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cm soil / hard dense soil.
21
-
-
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point.Soft Soil / hard dense soil
3
-
-
Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed.
100
-
-
S&F tube light grade galvanised with all fittings laid in trenches of following size (a) 50 mm bore.
6
-
-
Material and Labour for cutting bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with cement concrete 1:2:4, type, B-2 to match the existing surfaces of the road all as specified and as directed by Engineer in charge.
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements