Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Feb 2025
Closing Date15 Feb 2025
Tender Amount₹ 36,50,000
Costs
EMD
₹ 73,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676230_3Tender No
8178/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(c) Fuel Filter Pre.
16
-
-
... More
(d) Fuel Filter Micro.
10
-
-
... More
(e) Air Filter Safety.
6
-
-
... More
(f) Air Filter Primary.
4
-
-
... More
(g) Koel Care Super Oil.
310
-
-
... More
(h) Koel Care Coolant Premix.
30
-
-
... More
S & F Battery 12 V 180 AH for DG set complete all as specified and directed.
2
-
-
... More
M & L for replacing the existing damaged/bulged radiator flexible rubber hose for 62.5 KVA to 160 KVA Capacity Genset installed at various installation and replaced with new radiator flexible hose with circular hose clips complete all as specified and directed by the Engineer-in-Charge.
2
-
-
... More
Description all as per Item No 4.00 above but 250 KVA Capacity Genset complete all as specified and directed by the Engineer-in-Charge.
1
-
-
... More
Taking down the existing worn out Fanbelt (V Belt) for 62.5 KVA to 160 KVA Capacity Genset installed at various installation and replaced with new fan belt complete all as specified and directed by the Engineer-in-Charge
2
-
-
... More
Description all as per Item No 6.00 above but 250 KVA Capacity Genset complete all as specified and directed by the Engineer-in-Charge.
1
-
-
... More
Taking down the existing unserviceable water pump assy for 62.5 KVA to 250 KVA Capacity Genset installed at various installation and replaced with new water pump assy complete all as specified and directed by the Engineer-in-Charge.
1
-
-
... More
Taking down old unserviceable point wiring, (light, fan, socket or power) complete including fittings & fixtures such as switch, ceiling rose, pendants, fan regulator, socket, etc., and making good the disturbed surface of wall, floors, ceiling etc to match with the existing including touch up of paint/white wash complete all as specified and directed.
60
-
-
... More
M & L for Point wiring with 1.5 Sq mm copper conductor multistranded FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing/conduit surface type and accessories of suitable size ISI marked and PVC terminal boxes of 1.6 mm thick of suitable size including fixing/grouting sunken/ surface/ concealed on wall & roof as per site requirement incl provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm multistranded copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for :
(a) One light point controlled by one, one way switch 5 Amps complete all as specified and as directed.
25
-
-
... More
Description all as per Item No 10.00 above but :
(b) One fan/exhaust point controlled by one switch complete all as specified and as directed.
15
-
-
... More
Description all as per Item No 10.00 above but :
(c) One socket 5 Amps on same board complete all as specified and as directed.
10
-
-
... More
Description all as per Item No 10.00 above but :
(d) One socket 5 Amps on independent board complete all as specified and as directed.
7
-
-
... More
Description all as per Item No 10.00 above but :
(e) One bell point controlled by one, one way bell switch 5 Amps complete all as specified and as directed.
3
-
-
... More
S & F ceiling fan regulator step type, regular/modular type heavy duty suitable to work on 230 volts Ac supply complete all as specified and as directed.
30
-
-
... More
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
30
-
-
... More
S & F in replacement sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed.
6
-
-
... More
S & F in replacement sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed.
4
-
-
... More
S & F in replacement sheet metal enclosure VTPN DB, 4 way incomer MCCB type with 200 Amps rated bus bar 315 volts double door with magnetic locking system including refixing / fixing of incoming & outgoing MCCB/ MCBs and making smooth the wall surfaces complete all as specified and as directed.
2
-
-
... More
Supply and Fixing only MCBs of following rating:-
(a) MCB SP 6 to 32 Amps 240V 10 KA. "C" Series complete all as specified and as directed.
40
-
-
... More
(b) MCB SPN upto 32 Amps 240V 10 KA. "C" Series complete all as specified and as directed.
10
-
-
... More
(c) MCB SPN 40 to 63 Amps 240V 10 KA. "C" Series complete all as specified and as directed.
4
-
-
... More
(d) MCB TP upto 32 Amps 415V 10 KA. "C" Series complete all as specified and as directed.
4
-
-
... More
(e) MCB TPN upto 63 Amps 415V 16 KA. "C" Series complete all as specified and as directed.
Note for Item Nos 16.00 to 16.40:- MCBs / MCCBs will have to suite upon with the base of the existing Panel / DB as per site requirement
2
-
-
... More
S & F in repairs switch piano single pole flush type 5 Amps, 230 volts including removal of old existing unsv one complete all as specified and as directed.
50
-
-
... More
S & F Modular switch 1 way 6 A, 1 Module complete all as specified and as directed.
50
-
-
... More
S & F Modular switch 1 way 16 A, 1 Module complete all as specified and as directed.
20
-
-
... More
S & F Modular Socket 6A-2/3 pin combined 2 module complete all as specified and as directed.
20
-
-
... More
S & F Modular Socket 6A/16-2/3 pin combined 2 module complete all as specified and as directed.
20
-
-
... More
S & F Modular Fan step regulator, 80W-2 Module complete all as specified and as directed.
20
-
-
... More
S & F Modular Bell Push 6 A, 1 Module complete all as specified and as directed.
5
-
-
... More
S & F ultra bright LED tube rod 18/20 with output of 1800 lumens (single side connection) with very high efficacy suitable for installation in existing tubelight G13 lamp holders to give glare free light with necessary wiring and removal of old existing unserviceable tube from fitting complete all as specified and as directed. Make :- Bajaj, Philips, Wipro, Havells, Syska, Jaquar
80
-
-
... More
S & F wall mounted LED 18/20 watts with out put of 1800 lumens , box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver connector block etc., complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 18 watts including removal of old existing unsv tube light fitting complete all as specified and as directed.
Make :- Bajaj, Philips, Wipro, Havells, Syska, Jaquar
40
-
-
... More
Taking out the existing any type of fittings on ceilings and S & F 36 Watt LED luminaire suitable for 600 x 600mm modular ceiling grid including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 3600 total lumen. The 36 W system shall be operating at 220-240v AC supply having internal driver with IP20,surge protection 2KV , ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz .The system efficacy must be between 80-100 lumen /watt ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , CRI minimum 80. PF should be greater than 0.95 , THD 10% . Individual LED's should not be visible for glare free output ,colour temperature 6500k complete all as specified and as directed. Make :- Bajaj, Philips, Wipro, Havells, Syska, Jaquar
6
-
-
... More
Taking down the ceiling / exhaust fans of any model, size & sweep carefully from its original position and dismantling motor and over hauling complete by cleaning all dust / grease with kerosene or petrol, & replacement of unserviceable bearings, bushes, split pins and nut and bolts and applying new grease for bearings, reassembling the motor and fixing the blades, preparation of old surfaces of fan of any sweep & model and painting with synthetic enamelled paint by spraying including filling cavities and testing and refixing the same complete as directed by Engr in Charge.
Note for Item (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as ''Supply only'' (s) of this schedule. However labour element involved in replacement is included in unit rate quoted against this Item.
(ii). Any unforeseen minor repair and minor parts like Rubber bush, MS Clamps, split pins, base frames, nuts, bolts etc that are not covered under Item No 28.00 to 28.30 but required to complete the repair work / smooth functioning of fan motor shall be deemed to be included with the unit rate .Transportation of Stator / Rotor parts for machining & rewinding, shaft / bushing for machining , welding , turning at lathe shop at Port Blair are also deemed to be included with unit rate.
(iii). Rewinding of stator / rotor of motor, any machine work where involved shall be measured and paid separetely against relevant item of this schedule.
45
-
-
... More
Supply only following spares of ceiling / exhaust fan of any model, size & sweep to incorporate against each Item of Schedule 'A' here-in-above complete all as specifed & directed (a) Supply only ball bearing suitable for ceiling fan upto 1400 mm sweep complete all as specified and as directed.
30
-
-
... More
(b) Supply only ball bearing suitable for Exhuast fan upto 450 mm sweep complete all as specified and as directed.
5
-
-
... More
(c) M&L for rewinding the motor of ceiling Fan 1200mm/1400mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size & capacity including, varnishing, drying etc, and refixing the stator and rotor perfectly to rotate smoothly and connection alongwith fixing of 2.5 MFD fan capacitor complete including taking out burned unserviceable copper winding wire all as specified and as directed.
30
-
-
... More
(d) M & L for rewinding the motor of Exhaust Fan 300 / 450 mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size & Capacity including, varnishing, drying etc,and refixing the stator and rotor perfectly to rotate smoothly and connection alongwith fixing of suitable fan capacitor complete including taking out burned unserviceable copper winding wire all as specified and as directed.
Note for item 28.20 and 28.30:- Rates for incorporation of new fan capacitor of suitable capacities for smooth runinng of fans are deemed to be inclusive in the quoted rates
7
-
-
... More
S & F in repairs capacitor 2.5 MFD capacity including removal of unserviceable ones complete all as specified and as directed.
70
-
-
... More
S & F in repairs capacitor 4 MFD capacity including removal of unserviceable ones complete all as specified and directed.
5
-
-
... More
M & L for taking out & servicing split type air conditioner in situ (Split type air conditioner comprises wiith outdoor and indoor unit complete) of capacity 1.5/ 2.0 TR of any make and any type by replacing unserviceable parts from the machine including charging of Refrigerant gas after vacuuming and leak testing. Brazing the suction/ discharge tubes where required and cleaning of cooling coil and condenser coil, oiling, greasing of blower motor, checking of electrical circuit and replacement of defective electric blower fan motor, over load protector, relay, capacitor etc to achive proper cooling effect and also checking of electronic circuit of machine and repair where necessory by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing commissioning & refixing in same or new location complete all as specified and as directed.
12
-
-
... More
Note:- (i) Compressor where ever is required shall be measured and paid separately under respective item.
(ii) During vacuming the machine existing Refrigerant shall be collected in cylinder and the same shall be reused while charging after carry out of repair and additional qty required for smooth functioning shall be measured and paid separately under respective item.
(iii) Spares parts whereever is required shall be measured and paid separately under respective item of schedule A.
(iv) Unit rate is deemed to be included for minor parts such as capilary tube, machine screw, washer, rubber bush etc required for proper setting of machine.
(v) Unit rate is deemed to be included for necessary opening in window / wall of any type and thickness, cutting of grill any type / size fixing of AC & necessary plywood, commercial type, 6 mm thick of suitable size as packing material to cover the hole/ window
(vi) Transportation for shifting of AC's will be provided by contractor and rate for same is deemed to be included in quoted rate.
-
-
-
... More
Supply only electric blower fan motor of split AC 230 volt 1340 RPM single shaft with ball bearing for any make split AC 1.5 Ton capacity complete all as specified and directed.
2
-
-
... More
Supply only running capacitor upto 50 (+,- 6) MFD and complete all as specified and as directed.
5
-
-
... More
Supply only starting capacitor 100/120 MFD complete and complete all as specified and directed.
2
-
-
... More
S & F for indoor unit condenser coil of split type air conditioner 1.5 ton capacity wall mounted operation and performing on cooling system of make as per site requirement including removal of old existing unsv one complete all as specified and as directed.
1
-
-
... More
Taking down existing unserviceable outdoor condenser coil unit and supply and fix new outdoor condenser coil unit for 1.5 TR capacity Split AC working with compressor of make as per site requirement complete all as specified and as directed.
1
-
-
... More
S & F for flexible PVC/hose pipe 20 mm dia heavy duty from outdoor unit including removal of old existing unsv one complete all as specified and directed.
50
-
-
... More
M & L for filling up & charging of R - 22, 32, 410a etc refrigerant or type of gas as per site requirement for window/spilt type air conditioner of capacity 1.5TR, refrigerator and water cooler of capacity 80/40 litres after leak testing of complete system and making good by bracing complete all as specified and as directed.
10
-
-
... More
S & F for PCB (Printed Circuit Board) of indoor unit suitable for existing 1.5 ton capacity split AC including removal of old existing unsv one complete all as specified and as directed.
2
-
-
... More
Removing the old unserviceable sealed compressor unit from split AC of any make, capacity 1.5 TR and supply and fixing new hermetically sealed compressor of same make as that of the existing for split AC of capacity 1.5 TR with necessary mounting arrangements suitable for working with non CFC refrigerant including charging of non CFC refrigerant gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and as directed.
1
-
-
... More
Disconnecting/dismantling in position minor servicing /overhaul of 11 KV distribution transformers upto 500 KVA capacity for any type of leakage/defect at LT/HT bushing, gasket, drain plug etc., after disconnecting of electric supply and earth connections, drain out transformer oil and keeping in close containers for re-use, lifting /removing of top cover of transformer if it requires, re-assembling of transformer with S & F of new gasket set assembly, replacement of nuts, bolts and washers, as required at site, re filling of Transformer oil, complete after electric connections and testing complete all as specified and directed by Engr-in-Charge.
Note :- (i) If retrieved transformer oil's di-electric strength is less than 20 KV it will be replaced with new one in relevent items. (ii) If any minor items is required for smooth functioning of transformer including general cleaning of surrounding area and equipment also, the cost of the same will be deemend to be included in the unit rates.
3
-
-
... More
Checking of old transformer oil and re-filling the same to transformer after de-hydrate of oil in filtration machine. The machine continuously round the clock till the result of oil upto 50 KV dielectric strength in 2.5 mm gap is achieved complete all as specified and as directed.
1200
-
-
... More
M & L for filling of new transformer oil having dielectric strength not less than 60 KV complete all as specified and directed by the Engineer-in-Charge Make:- Power oil / Castrol
300
-
-
... More
M & L for breather container of suitable capacity for 11 KV up to 500 KVA distribution transformer complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
M & L in replacement of lightening arrestor expulsion type 11 KV with all fittings, transmission class, discharge discharge current class II rating 9 KV 10 KA including fixing arrangement as required complete all as specified and as directed.
1
-
-
... More
M & L in replacement of 11 KV DO Fuse unit channel type with all types of fixing arrangement complete including dismantling all as specified and directed by Engr-in-Charge.
1
-
-
... More
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
118.65
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and as directed.
106.23
-
-
... More
Removing excavated material (soil) to a distance not exc. 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed.
20.1
-
-
... More
Supply and laying XLPE, insulated, armoured, heavy duty, electric cable of cross sectional area 3.5 Core x 120 Sqmm with stranded aluminium conductors, 1100 volts grade, laid in trenches/ fixing on wall /poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, including taking down existing unserviceable cable with GI protections pipes, complete all as specified and as directed.
Make : Havells / Polycab / Finolex / Gloster
70
-
-
... More
Description all as per Item No 50.00 above but of cross sectional area 3.5 Core x 70 Sq mm complete all as specified and as directed.
120
-
-
... More
Description all as per Item No 50.00 above but of cross sectional area 4 Core x 25 Sq mm complete all as specified and as directed.
100
-
-
... More
Description all as per Item No 50.00 above but of cross sectional area 2 Core x 16 Sq mm complete all as specified and as directed.
100
-
-
... More
S & F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 120 mm and inner dia of 103 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed.
170
-
-
... More
S & F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed.
190
-
-
... More
S & F GI pipe 50mm bore light grade with all fittings laid in trenches/on wall / on poles etc/ for protection complete all as specified and directed.
18
-
-
... More
Supply and installation of LED 45 W Street Light, IP-66 (Waterproof) Outdoor Light, Cool White with BIS approved driver, heat management with aluminum heat sink, with protections available -short circuit, open circuit, under voltage, over voltage, isolution, 6kv - internal surge protection complete all as specified and as directed. Note : Necessary 20 mm PVC conduit & 1 sq mm 3 core PVC sheathed PVC insulated copper cable upto 5 m is deemed to be inclusive in quoted rate.
5
-
-
... More
Supply and installation LED 100 W Flood Light, IP-66 Outdoor Light, Cool White with BIS approved driver, heat management with aluminum heat sink, with protections available -short circuit, open circuit, under voltage, over voltage, isolution, 6kv - internal surge protection complete all as specified and as directed.
2
-
-
... More
S & Fin repairs 9 W LED Lamp suitable for garden lights including removal of unserviceable one from the existing fitting and refixing it in same position complete all as specifed and as directed.
50
-
-
... More
S & F replacement of driver of LED street light / flood light / garden light/ gate light of upto 90W and including necessary connections to make fitting serviceable complete all as directed.
41
-
-
... More
S & F replacement of driver LED street light / flood light of more than 90 W and including necessary connections to make fitting serviceable complete all as specified and as directed.
15
-
-
... More
M & L for preparation of old painted surfaces of two pole RCC structural and transformer and cleaning the surface etc., and applying two coats of synthetic enamel paint based paint white colour and in bottom black colour including applying two coats of synthetic enamel paint silver colour on bracket of street lights and on clamps, writing the all details as per direction complete all as specified and as directed.
4
-
-
... More
M & L for preparation of old painted surfaces of steel tubular / RCC pole and cleaning the surface etc. and applying two coats of synthetic enamel paint based paint white colour and in bottom black colour including applying two coats of synthetic enamel paint silver colour on bracket of street lights and on clamps, writing the all details as per direction complete all as specified and as directed.
Note : 1.5 Sqmm multistranded copper cable drawn in 20 mm non rigid PVC conduit including clamping from fitting to FRP Junction box are deemed to be inclusive in above quoted rates
50
-
-
... More
M & L for preparation of old painted surfaces of LT feeder piller box/HT & LT panels by scrapping with wire brush and cleaning etc. and applying two coats of synthetic enamel paint with use of spray gun of approved grey colour and writing the details as per direction with white colour in back ground complete all as specified and as directed.
8
-
-
... More
Dismantling unserviceable burnt out timer by disconnecting the cable and repairing of existing three phase timer in the existing panel boards with new display, switches, relay, MCBs, bolts, nuts, lugs & glands etc complete all as specited and directed.
Make: L&T, Legrand, Havells
1
-
-
... More
Dismantling unserviceable burnt out MCCB by disconnecting the cable and S & F new MCCB's in the existing panel boards with new bolts, nuts, lugs & glands etc of the following capacities complete all as specited and directed.
Make: L&T, Legrand, Havells
(a) MCCB 25 to 100 A Fixed type, 4 pole 16 KA, 415 Volts.
3
-
-
... More
(b) MCCB 160 A Fixed type, 4 pole 16 KA, 415 Volts.
3
-
-
... More
(c) MCCB 200 A Fixed type, 4 pole 16 KA, 415 Volts.
1
-
-
... More
(d) MCCB 200 A Fixed type, 4 pole 16 KA, 415 Volts.
1
-
-
... More
M & L for addition alteration in old GI/CPVC pipe, screwing, cutting, threading, fixing of GI fittings like union, elbow, tees, nipples, dummy, plugs etc of upto 100 mm bore including attending any minor work regarding pipe line complete all as specified and as directed.
Note:- Rates for necessary GI fittings like union, tees, nipples, elbow etc is deemed to be inclusive in above quoted rates.
6
-
-
... More
S & F steel tubes, 100mm dia bore medium grade galvanized with all fittings and fixed complete laid in floors / trenches / fixed to wall and ceiling including taking down the existing old pipe complete all as specified and directed.
6
-
-
... More
Description all as per Item No 65.00 above but 80 mm dia bore complete all as specified and as directed.
18
-
-
... More
Description all as per Item No 65.00 above but 50 mm dia bore complete all as specified and as directed.
12
-
-
... More
S & F CPVC pipe 20 mm dia bore with all fittings and fixed complete laid in floors / trenches / fixed to wall and ceiling including taking down the existing old pipe complete all as specified and directed.
40
-
-
... More
S & F CPVC pipe 25mm dia bore with all fittings and fixed complete laid in floors / trenches / fixed to wall and ceiling including taking down the existing old pipe complete all as specified and directed.
100
-
-
... More
S & F CPVC pipe 40 mm dia bore with all fittings and fixed complete laid in floors / trenches / fixed to wall and ceiling including taking down the existing old pipe complete all as specified and directed.
100
-
-
... More
M & L for cleaning of shallow water wells of size 4m dia, 10m depth by dewatering the complete well, removing the sediments settled at the bottom and depositing where directed, scrapping the walls with wire brush and washing with clear water and applying two coats of anti fungal white paint internally and writing the date of cleaning, due date of cleaning and capacity of well in paint (white letters on black background) complete all as specified and as directed.
3
-
-
... More
M & L for cleaning of RCC water tanks (inside) by dewatering the complete tank, removing the sediments settled at the bottom of tank, scrapping with the help of shovels, hard brushes and physical cleaning of tanks (Reservoir) by de-scaling/brooming silt and sludge and other deposits from inner side (bottom of dome), collecting and taking them out with the help of manual labour and depositing at a distance not exceeding 50m and making the tank clean and washing properly with bleaching powder mixed with water (1:10) and applying two coats of white wash both internally writing the date of cleaning and capacity of tank in paint (white letters on black back ground) and including removing of any vegetation growth on and around the tank complete all as specified and directed by Engineer -in-charge with the following capacities and description:-
Note:- (i) Work is to be executed at 15 to 25m height (ii) All necessary T&P, labours and materials will be arranged by the contractor with pre cautionary measures (a) Overhead reservoir of capacity 45,000 litres
1
-
-
... More
Description all as per Item No 72.00 above but Underground sump of capacity 20,000 litres complete all as specified and as directed.
4
-
-
... More
Description all as per Item No 72.00 above but Underground sump of capacity 3,00,000 litres complete all as specified and as directed.
1
-
-
... More
M & L for cleaning of RCC / rotational moulded PVC water storage service tanks of capacity 5000 litres on buildings by dewatering complete tank, removing sediments setteld at the bottom of tank and scraping the walls and bottom of tank, removing any vegetation growth and cleaning with bleaching powder solution, washing with clear water and writing the date of cleaning in white paint complete all as specified and as directed.
10
-
-
... More
Description all as per Item No 75.00 above but 2000 litres capacity complete all as specified and as directed.
20
-
-
... More
Description all as per Item No 75.00 above but 1000 litres capacity complete all as specified and as directed.
30
-
-
... More
Description all as per Item No 75.00 above but 500 litres capacity complete all as specified and as directed.
24
-
-
... More
Dismantling existing unserviceable PVC water tanks and supply and fix PVC rotational moulded water tank of 2000 litres capacity two layered hoisted and fixed in position including provision of necessary inlet / outlet / over flow pipe and connected with the existing pipe lines complete all as specified and directed.
1
-
-
... More
Description all as per Item No 79.00 above but 1000 litres capacity complete all as specified and as directed.
2
-
-
... More
Description all as per Item No 79.00 above but 500 litres capacity complete all as specified and as directed.
1
-
-
... More
S & F ball valve, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm bore dia including taking down the existing old one complete all as specified and directed.
3
-
-
... More
S & F ball valve, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 25 mm bore dia including taking down the existing old one complete all as specified and directed.
4
-
-
... More
S & F Gun metal gate valve,with iron wheel head, screwed both ends for iron pipe 20mm bore dia including taking down the existing old one complete all as specified and directed.
4
-
-
... More
S & F Gun metal gate valve,with iron wheel head, screwed both ends for iron pipe 25mm bore dia including taking down the existing old one complete all as specified and directed.
8
-
-
... More
S & F Gun metal gate valve,with iron wheel head, screwed both ends for iron pipe 40mm bore dia including taking down the existing old one complete all as specified and directed.
3
-
-
... More
S & F Gun metal gate valve,with iron wheel head, screwed both ends for iron pipe 50mm bore dia including taking down the existing old one complete all as specified and directed.
3
-
-
... More
M & L for full automatic star Delta motor starter in sheet steel enclosure with motor rating AC-3 duty, 415 Volts, 50 Hz, 6 phase suitable for 7.50 HP to 20 HP electric motor of centrifugal pump having discharge 15000 GPH at 30meter head including incoming electric panel and outgoing of starter with electric motor terminal plate with lugs and thimbles complete with mounting arrangement and testing on completion all as specified and directed by Engineer-in-Charge.
2
-
-
... More
S & F Single Phase DOL Starter with enclosure for 2 HP complete all as specified and as directed.
Make: L&T/Siemens/ ABB/ C&G/ GE
1
-
-
... More
Supply only the following materials required for day to day maintenance of water supply installations : - (a) Bleaching Powder for disinfection of water complete all as specified and as directed.
150
-
-
... More
(b) Granular hi-strength chlorine chemical with CIAS OF CHLORINE STRENGTH 55 % available 45 Kg drum complete all as specified and as directed.
90
-
-
... More
(c) White Sulphate alum in 10 Kg Blocks for sedimentation of water complete all as specified and as directed.
100
-
-
... More
M & L for overhauling of pressure feed filter plant of capacity upto 27000 LPH by carefully removing the old unserviceable media complete from plant from its installed position carrying out the maintenance with following replacements and reinstalling in its original position and testing on completion, and painting of pressure filter all as specified and directed. Note: Pressure feed filter needs to be cleaned and change the media once in a year & media replaced will be paid saperately (a) Sand filter media (Coarse/ Fine Sand) complete all as specified and as directed.
2
-
-
... More
(b) Sand filter media (Coarse/ Fine Sand) complete all as specified and as directed.
600
-
-
... More
(c) Dolomite/ Pebbles complete all as specified and as directed.
600
-
-
... More
(c) Coarse/ Fine Silex for Pressure Filter complete all as specified and as directed.
600
-
-
... More
(d) Activated Carbon complete all as specified and as directed.
500
-
-
... More
M & L for overhauling of RO plant of capacity 1000 LPH by carefully dismantling the complete plant from the installed position carrying out the following maintenance and re-installing in its original position including testing in completion complete all as specified and directed.
(a) Opening the raw water fed pump (01 No) replacing the unserviceable water seal and re-assembling
(b) Disconnecting and removing unserviceable PU4 pipes (Approx 15m) and connecting new PU4 pipes.
(c) Steel water tank cleaning and brazing if required of capacity 5000 ltr
Note: The materials and element for fixing of items are deemed to be included in the unit rate quoted.
1
-
-
... More
Supply and fixing ,testing the following materials required for overhauling of RO plant:- (a) 10/5 micron jumbo filter cartridge
6
-
-
... More
(b) Membrane of dimension 40"x40"
2
-
-
... More
(c) Multi port valve 25 NB
1
-
-
... More
(d) Chemical wash for membrane
12
-
-
... More
M & L for Rewinding burnt coils of Induction Motor capacity upto 5 HP obtained from site as defective taken into workshop replace winding with super enamelled copper winding wire as per existing size and guage to achieve the required /specified RPM including taking out old unserviceable winding, cleaning / repairing damaged slots , complete all as specified and directed.
1
-
-
... More
M & L for Rewinding burnt coils of Induction Motor capacity 7.5 to 15 HP obtained from site as defective taken into workshop replace winding with super enamelled copper winding wire as per existing size and guage to achieve the required /specified RPM including taking out old unserviceable winding, cleaning/ repairing damaged slots complete all as specified and directed.
2
-
-
... More
S & F CI foot valve 50mm dia with flanged ends jointing with suitable rubber gasket, nuts, bolts and washers complete including taking down the existing unserviceable old one from well/sump complete all as specified and directed.
1
-
-
... More
Description all as per Item No 96.00 above but 80 mm dia complete all as specified and as directed.
3
-
-
... More
M & L for Sluice Valve 100/80 mm bore PN 1.6 class including removal of old unserviceable one complete all as specifed and as directed
3
-
-
... More
S & F Single phase preventer fixed on existing pump panel/stator panel complete all as specified and as directed.
6
-
-
... More
Servicing / overhauling of Electric driven Vertical / Horizontal split casing Pump sets installed at Pump Houses coupled with upto 15 HP Motor along with following others repairs.
(a) Taking out pump from its Position by decoupling from Motor and disconnecting all suction /delivery water connections , setting aside Pump from base plate (b) Dismantaling of Pump complete part by part carefully , degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts.
(c) Replacement of Gasket set and gland packing rope .
(d) Reassembeling the Pump complete with all existing serviceable parts obtained against Item No 19.1, greasing the bearing with bearing grease , and new parts as ordered by Engineer in Charge.(Note : New parts shall be measured and paid separately under appropraite Item here-in-after)
4
-
-
... More
(e) Reinstall the Pump at its existing Position , couple with the Motor and connecting all suction delivery water connections and testing on completion
Note:- (i) Any Parts required for replacement shall be measured and paid seperately under appropriate item as ''Supply only'' (s) of this schedule. However labour element involved in replacement is included in unit rate quoted against this Item.
(ii) Any unforeseen minor repair and minor parts that are not covered under Items hereinbefore but required to complete the repair work / smooth functioning of Motor / Pump shall be deemed to be included with the unit rate .Transportation of Stator / Rotor parts for machining & rewinding, shaft impeller bushing for machining , welding , turning at lathe shop at Port Blair are also deemed to be included with unit rate.
(iii) Rewinding of stator / rotor of motor, any machine work where involved shall be measured and paid separetely against relevant item of this schedule.
-
-
-
... More
Supply only the following Items of Pumpset & Motor to incorporate against each Item No 100.00 above :
(a) Rubbers for Coupling for different capacity pump set
8
-
-
... More
(b) Bearing as per existing size
2
-
-
... More
(c) Bakelite Terminal connection plate with brass nuts bolts and washers
3
-
-
... More
(d) Plastic Rotar Fan
2
-
-
... More
(e) GI Flange 80 mm bore
8
-
-
... More
(f) GI Flange 50 mm bore
2
-
-
... More
(g) Leather gasket for Flange 100 mm bore
2
-
-
... More
(h) Leather gasket for Flange 80 mm bore
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%