The Singareni Collieries Company Limited Tender
... More
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
482546Tender No
CW/RD/e-51/2023-24Tender Authority
The Singareni Collieries Company Limited ViewPurchaser Address
-Website
http://https://scclmines.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply and Fixing 15 mm CP concealed stop Valve not less than 400 grams weight quarter turn spindle conforming to IS 8931
1
728
728
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand UPVC/ SWR Pipe (as per ISI- standards) fittings like bends, tees, Ys, etc., For Vent Cowl - 110mm dia
1
23
23.9
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Cement Concrete 1:5:10 with 40 mm size Crushed Granite metal of approved hard quality in foundations or Plinth etc., Complete. (But Excluding Cost of Cement) - with concrete mixer
2
3628
7257.98
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply and fixing Door frame of 100 x75mm with Non teak wood including supply and fixing with 6nos. M.S.Z type hold fasts made out of 50x3mm M.S.flat 300mm long in CC beds, etc., complete. (Excluding Cost of Bed Blocks.)
10
738
7389
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Varnishing/French Polishing to wood work - 2 coats - complete for finished item of work
14
184
2581.6
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply of Structural Steel Angles/Channels/Beams/ Square Bars for the month of August - 2023(Inclusive of 13.615% CP and OH)
0.24
68169
16360.56
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Extra depth of 450mm x 450mm Inspection Chamber beyond 450mm depth (Excluding cost of cement) Extra for every 0.100m (100mm) depth
2
481
962.92
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Add Extra for shuttering and centring charges for CC - Basement / Sidewalls, Water Tank Walls
12
393
4717.2
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and fixing 150mm x100mm SWG gully traps Conforming to IS- 651 and 4127 with C.I Grating and Constg. Brick masonry in CM 1:6 prop. including plastering and fitted with 304.8mm x288.6mm(12 Inchesx9 Inches) C.I Frame and hinged cover including earth work excavation (excluding cost of Cement)
1
618
618.1
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Conveyance charges of CEMENT including loading, unloading and stacking charges for 1 KM lead.
5.35
233
1247.08
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and fixing TV shape mirror with plastic frame size 609.6x457.2mm
1
610
610.9
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Labour Charges for Fabrication of steel works like window grills, compound wall grills, Iron Doors, windows, Verandah grils and window guard bars including cost of welding rods, power charges etc., ( Excluding cost of fixing in position)
240
34
8184
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and fixing of Stainless steel finish Health Faucet with 1m long tube, faucet gun and wall hook
1
567
567.4
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying, laying, jointing RCC NP2 hume pipes (socket and spigot) confirming to IS 458/2003, with necessary rubber rings (as per IS 5382/1985) cost and conveyance of all materials to site, labour charges, all operational charges etc complete as directed for finished item of Work For 150mm dia Pipes. NOTE:- Transportation of pipes includes up to 5 KM from Factory. For any extra lead, necessary extra lead charges may be added.
30
454
13647
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying, laying, fixing and commissioning the SWR pipes of Prince / Sudhakar / Kisan / Supreme or any ISI Brand SWR Pipe (as per ISI - standards) Type - A pipes (PVC / SWR pipe - 4Kg / sq.cm ) for rain water and vent pipes of any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice excluding cost of fittings - For 110mm dia 3M Double socket pipe
3
1055
3165.9
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Cement Concrete 1:3:6 with 40mm down size (50% of 40-20mm, 30% of 20-10mm and 20% of 10-4.75mm) graded Crushed Granite metal of approved hard quality including machine mixing, vibrating, etc., Complete for finished Item of work as directed for Side Walls of Drains or Basement/ Substructure of the Buildings (Excluding Cost of Cement, Centering and shuttering charges) (CA : 0.90 Cum, FA:0.45Cum)
3
3672
11016.27
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Conveyance charges of Steel including loading, unloading and stacking charges for Beyond 30KM (Rate/KM) lead.
7.5
8
63
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Providing Dadooing to walls with ceramic wall tiles of size 200x300mm / 245mm x 325 mm and thickness 6 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, set over base coat of CM (1:3) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost and conveyance of all materials, labour charges etc., complete for finished item of work,( But Excluding Cost of Cement )
16
702
11239.84
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Reinforced Cement Concrete 1 : 1.5 : 3 with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum) - For Lintels.
0.7
10455
7318.84
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand UPVC / SWR Traps ( as per ISI- standards ) - For 4 Inches(101.6mm) Nahani Trap (With Jali with inlet)
2
170
340.8
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply and Fixing of CPVC Pipes along with Fittings to meet the requirement of ASTM-D 2846 etc., complete - For 28.60mm OD Pipe - SDR 11
50
273
13670
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Plastering to brick masonry with cement mortar 1:4, 12mm thick including raking out of joints ( But Excluding Cost of Cement )
23
160
3690.81
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Providing and fixing 600mm x600mm, 15mm thick Arm strong false ceiling system manufactured by M/s Arm strong world Industries using hot dipped Galvanised Steel section exposed surface with pre-coated capping, main Tee of size 24x32mm at every 1200mm c/c maximum and rotary stitched cross tee of size 24x27mm at evry 600mm c/c and sub-cross tee of size 24mm x25mm at 1200mm c/c and wall angle of size 19x19mm fixed to periphery of the wall and the above grid is suspended at every 1200mm c/c in both directions using 2.0 mm thick pre-straightened GI Wire laying fine fissured butt edge ceiling tiles of 15mm thick mineral fibre Board for finished size 600x600mm including Cost and conveyance of all materials and labour charges such as cutting, fixing of standing of frame work exposing roof making complete for finished item of work
57
1354
77195.1
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;S and F CP finish steel towel rod of 600 mm long and 20 mm dia with brackets
1
484
484.9
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Construction of 450mm x 450mm and 450mm depth Inspection Chamber with CC 1:4:8 base of 150mm thick 40 mm Crushed Granite metal and 225 mm thick Brick masonary walls in CM 1:6 with fly ash bricks of size 225 x 100 x 60mm with 50kg/Sq. Cm Compressive strength and plastering with CM 1:4; 12mm thick including rendering the surfaces smooth both inside and outside and channelling to required slope including supply and fixing precast RCC 1:2:4 cover of 50mm thick and 600 X 600mm size with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal, including earthwork excavation to the required depth etc; complete for finished item of work (but excluding cost of cement steel and its fabrication charges.)
1
3202
3202.22
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and fixing of CPVC unions - For 15 mm (1/2 inch) union
2
77
154.2
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Binding wall 225 x 225mm size with brick in cement mortar 1:6 with fly ash bricks of compressive strength 50Kg/cm2 with 20mm thick plastering with cement mortar 1:6, without cornice (But Excluding Cost of Cement )
22
508
11191.18
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Rate for conveyance of RCC socket and spigot pipes on all weather roading including loading Unloading and stacking (per metre of effective length) (for NP2 pipes). (Rate for every additional 1 Km. lead or part there of beyond 5KM initial lead is only payable) - For 150 mm Dia pipes
150
-
51
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying Aluminium anodised Sections of approved make for Doors, partitions, windows, Ventilators (including anodisation cost) Confirming to IS 11857-1986
74
348
25811.2
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Extra depth of Circular Man Hole of Size 900mm dia( Excluding Rock cutting) beyond 450mm depth (Excluding cost of cement) Extra for every 0.100m(100mm) depth
2
705
1411.1
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply of 20mm PPR Ball Valve conforming to DIN Standards 8077/8092 including transportation of material to anywhere in the State (Excluding Taxes) - For
2
211
422.6
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Flooring with Non-skid Ceramic floor tiles of size 400 x 400 mm and thickness between 7-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, set over base coat of cement mortar (1:6), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per Sqm and jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost and conveyance of all materials, labour charges etc., complete for finished item of work, (But Excluding Cost of Cement )
61
870
53112.09
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Reinforced Cement Concrete 1 : 1.5 : 3 with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum) - For Sunshades.
1
14840
14840.79
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply and Fixing of 15 mm brass angle stop valve of quarter turn spindle type of not less than 400 grams weight with internal threaded conforming to IS 8931
1
729
729.2
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Providing and fixing PVC Door Frame of the size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2Nos. of 150mm long brackets of 15x15mm M.S square tube. The two vertical door profiles are to be reinforced with 19x19mm MS Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long MS screws through the frame by using PVC fasteners. A minimum of 4Nos. of screws to be provided for Each vertical member and minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-charge for finished item of work as per Approved Make
5.5
357
1968.45
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Construction of 900mm dia and 450mm depth circular manhole with CC 1:4:8 base of 150mm thick with 40 mm Crushed Granite metal, 225mm thick Brick masonry walls in C.M 1:6 with Flyash bricks of size 225X100x60mm and having compressive strength of 50 kg/sqcm, plastering with CM 1:4,12mm thick including rendering the surfaces smooth both inside and outside and benching with 100mm thick CC 1:2:4 with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal and channelling to required slope including supply and fixing precast RCC 1:2:4 cover of 50mm thick and 600mm dia using 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal, including earth work excavation to the required depth etc. complete for finished item of work (but excluding cost of cement, steel and its fabrication charges.)
2
4749
9499.12
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, and 15mm x 15mm for top and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC â??Câ?? channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail and bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the â??Câ?? Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturerâ??s specification and drawing for finished item of work including the Following Aluminium anodised fittings complete.: Single Shutter as per Approved Make a) 1no.of 200mm long aldrop with 16mm dia shoot. b) 2 nos. 200 to 250mm mm long tower bolt with 10mm dia shoot. c) 2 no. 100 mm to 150 mm long grip handle. d) 3 nos.150 mm long butt hinges.
1.5
3295
4942.65
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Plastering to brick masonry with cement mortar 1:6, 12mm thick including raking out of joints ( But Excluding Cost of Cement )
340
160
54559.8
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;S and F of 15 mm brass body CP finish long body bib tap of not less than 400 grams weight with quarter turn spindle internal / external threaded connection conforming to IS 8931
2
908
1817.4
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Conveyance charges of Steel including loading, unloading and stacking charges for Beyond 5KM and upto 30KM(Rate/KM) lead.
7.5
10
75.75
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and Fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS: 2556 - Part-4:1972 with waste fittings like 32mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400grams Seiko/Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550x400mm - Single C.P. Pillar Cock
1
2533
2533.8
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Labour charges for making and fixing Aluminium Doors as per approved drawing with aluminium anodized sections including cost of screws, bolts and nuts, beeding etc., excluding cost of alluminium sections and fixtures. The rate includes labour charges for fixing of glass/ particle boards.
10.08
836
8433.94
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and fixing of CPVC unions - For 25mm (1 inch) union
2
120
240.6
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and fixing 4 mm thick plain float glass panes of saint gobain / modiguard or equivalent make including putty / wooden beading / Rubber beading for wooden / iron windows.
13
1053
13699.4
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and Placing on Terrace(at all floor levels) polyethylene water storage tank with Double layer Approved Make and manufacture with cover and suitable locking arrangement and making necessary holes for inlet and outlets and over flow pipes but without fittings and base support for tanks
2000
9
19000
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply and fixing of PVC low level Cistern with internal components and short bend 10 Ltrs capacity Single flush
1
1887
1887.6
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Flyash Brick masonry with solid blocks of size 290x225x140mm with 50kg/cm2 Compressive strength in C.M.1:6 for superstructure including scaffolding etc., (But Excluding Cost of Cement ) complete.
32
5973
191164.16
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply and Fixing of CPVC Pipes along with Fittings to meet the requirement of ASTM-D 2846 etc., complete - For 22.20mm OD Pipe - SDR 11
30
230
6906
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Acrylic exterior emulsion Painting to New walls with Grade-II i.e., Ace or equivalent paint of Approved Make 2 coats over a base coat of Grade -II primer (making 3 coats in all) complete for finished Item of work -For External Walls
170
167
28458
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Labour Charges for Fixing of window grills, compound wall grills, Iron Doors, windows, Verandah grils, and window guard bars in position etc., complete.
240
5
1368
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Reinforced Cement Concrete 1 : 1.5 : 3 with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum) - For roof Slab - up to 150mm thick.
1.1
8414
9256.05
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Conveyance charges of Steel including loading, unloading and stacking charges for 5 KM lead.
0.3
317
95.32
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand UPVC/ SWR Pipe (as per ISI- standards) fittings like bends, tees, Ys, etc., For Plain Bend 87.5 degrees.- 110mm dia
2
104
209
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply and fixing best Indian make plastic seat and lid for European water closets with rubber or plastic Buffers as per IS 2548-1996
1
1369
1369.3
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and fixing wash down European water closet of first quality conforming to IS 2556-Part-2-2004 of white glazed with P trap. Plastic seat and lid is to be paid extra.
1
2118
2118.9
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply of 25mm PPR Ball Valve conforming to DIN Standards 8077/8092 including transportation of material to anywhere in the State (Excluding Taxes) - For
2
279
559
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply and Fixing of CPVC Pipes along with Fittings to meet the requirement of ASTM-D 2846 etc., complete - For 15.90mm OD Pipe - SDR 11
15
191
2874
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supply and fixing Flush door shutters, solid bond wood block board type with teak ply on both faces.: 35 mm thick conforming to IS:2202 as per Approved Make including the following Aluminium anodised fittings : conforming to relevant IS standards : Single Shutter a) 3 nos. 150 mm long butt hinges. ; b) 1 nos. 200 mm to 250 mm long tower bolt with 10mm dia shoot. c)2no.of 300mm long aldrop with 16mm dia rod. d) 2 no. 100 mm to 150 mm long grip handle. e) 1 no. foot door stopper with brass clip.
7
3837
26865.3
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Filling with excavated earth (excluding rock)/ Sand in trenches, sides of foundations and basement with initial lead in layers not exceeding 15 cm thick, consolidating Each deposited layer by watering and ramming including cost and conveyance of water to work site and all operational, incidental, labour charges, hire charges of T and P etc., complete for finished item of work. (APSS NO. 309 and 310) (Excluding cost of sand) - by Manual Means
30
34
1035
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and fixing of CPVC unions - For 20mm (3/4 inch) union
2
96
193
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Supplying and Fixing 15mm PVC connection with brass union nut C.P coated
2
137
274.2
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Roofing/side sheeting with Pre-painted Galvalume Trapezoidal Profile Roofing sheets with 0.50mm thickness, Coating: Alu-Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colours fixed with Suitable Bolts, nuts and washers, including fixing of wind ties as per the requirement etc., and including cost and conveyance of all materials etc., complete (with / without Ridges/ valley gutters) for finished Item of work as directed. (cost of wind ties and its fabrication charges are not included)
10
796
7969
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Providing Superior quality wall care putty 2 coats for internal / external walls complete for finished Item of work.
210
119
25116
... More
Alterations to existing garage for conversion into rooms for Digital X Ray plant Specialist Doctor;Earth work excavation for foundations and depositing on bank for all lifts and with an initial lead up to 50m including all operational, incidental, labour charges such as shoring, sheeting, planking, strutting, etc. complete for finished item of work as per SS - 20 B (APSS 308) - Ordinary Soil-Manual Means -Up to 3 m depth
25
243
6080
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements