Military Engineer Services Tender
View complete overview of MES Tender
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair/maint Work At Fad And Other Adjoining Area
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_674618_1Bid Award Id
ViewTender No
8500-163/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(c) 3.5 Core 120 to 150sqmm
500
-
-
... More
(d) 3.5 Core 185 to 400 sqmm
490
-
-
... More
(e) 2 Core 10 Sqmm
700
-
-
... More
M&L for dismantling of LT Poles 8.5mtr/9mtr including earth excavation upto 1.65 mtr for Hard dense soil, PCC demolition from foundation to upto palantimg depth and PCC coping etc, dismantling of existing accessories of Poles.i.e. Street Light alongwith Poles , PVC Junction Boxes, PVC cables of any size from Junction Boxes to Street Light etc complete all as speified and directed
12
-
-
... More
Supply & laying in replacement including testing & commissioning of cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:-
Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A
-
-
-
... More
(a) 3.5 Core 400 Sqmm
30
-
-
... More
(b) 3.5 Core 300 Sqmm
30
-
-
... More
(c) 3.5 Core 240 Sqmm
50
-
-
... More
(d) 3.5 Core 185 Sqmm
100
-
-
... More
(e) 3.5 Core 150 Sqmm
100
-
-
... More
(f) 3.5 Core 120 Sqmm
200
-
-
... More
(g) 3.5 Core 95 Sqmm
230
-
-
... More
(h) 3.5 Core 70 Sqmm
240
-
-
... More
(j) 3.5 Core 50 Sqmm
250
-
-
... More
(k) 3.5 Core 35 Sqmm
250
-
-
... More
(l) 4 Core 25 Sqmm
250
-
-
... More
(m) 4 Core 16 Sqmm
400
-
-
... More
(n) 4 Core 10 Sqmm
400
-
-
... More
(o) 2 Core 10 Sqmm
300
-
-
... More
Relaying serviceable LT UG cable of follwing sizes complete all as specified and directed.
Note:Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A
-
-
-
... More
(a) 3.5 Core 400 Sqmm
50
-
-
... More
(b) 3.5 Core 300 Sqmm
50
-
-
... More
(c) 3.5 Core 240 Sqmm
90
-
-
... More
(d) 3.5 Core 185 Sqmm
90
-
-
... More
(e) 3.5 Core 150 Sqmm
100
-
-
... More
(f) 3.5 Core 120 Sqmm
100
-
-
... More
(g) 3.5 Core 95 Sqmm
300
-
-
... More
(h) 3.5 Core 70 Sqmm
300
-
-
... More
(j) 3.5 Core 50 Sqmm
300
-
-
... More
(k) 3.5 Core 35 Sqmm
250
-
-
... More
(m) 4 Core 25 Sqmm
250
-
-
... More
(n) 4 core 10 -16 Sqmm
400
-
-
... More
(o) 2 Core 10 Sqmm
400
-
-
... More
Excavation in trenches in Hard/Dense soil, n.exc 1.5m wide and n.exc 1.5 m depth and getting out for foundation of pole, stay, laying of cable and pipe etc complete all as specified and directed.
703.08
-
-
... More
Returning and filling in, including spreading and well ramming in layers n exc 25 cm complete all as specified and directed.
224
-
-
... More
Removing excavated material a distance n.exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.
289.31
-
-
... More
M&L for dry sand cushioing to under ground cable in trenches incl spreading, leveling and hand punning complete all as specified and directed.
Note : For measurement purpose punned thickness shall be considered.
281.23
-
-
... More
Taking out old unserviceable bricks from the trench obtain during excavation for LT cables and staking aside for reuse or disposal etc complete all as specified and directed.
30.19
-
-
... More
Laying only serviceable bricks for protection of cable obtained from item No 9
15.1
-
-
... More
Supply and laying common fly ash building sub class B old size bricks, laid in right angle over the cable, complete all as specified.
15.1
-
-
... More
Supply and lay G.I pipe light grade in replacement with all fittings required for protection of under ground cable of following sizes:-
-
-
-
... More
(a) 150 mm
6
-
-
... More
(b) 100 mm
6
-
-
... More
(c) 80 mm
6
-
-
... More
(d) 50 mm
12
-
-
... More
(e) 40 mm
12
-
-
... More
M&L for Floor/PCC/Footpath cutting through existing PCC/floor/Footpath approx size width 15cm X 60cm depth as required for Realying/Laying of cable/ pipe etc and making good with and including earthwork and necessary excavation, complete material required to match with the existing one or with PCC 1:2:4 type B1 complete all as specified and as directed by Engr-in-Charge.
30
-
-
... More
M&L for drilling hole horizontally under road / pavement /hardstanding by trenchless method using machine suitable and including required size of HDPE pipe/GI Pipe etc complete all as specified and directed.
Note:- Pipes shall be measured and paid seperately
18
-
-
... More
Supply and lay High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches:-
-
-
-
... More
(a) 150 mm
6
-
-
... More
(b) 100 mm
6
-
-
... More
(c) 50 mm
6
-
-
... More
(d) 40 mm
12
-
-
... More
M&L for Straight through LT cable heat shirnkable jointing kit suitable for LT UG of following sizes cable complete
-
-
-
... More
(a) 10 Sqmm 4 Core/2 Core to 16 Sqmm 4 Core
15
-
-
... More
(b) 25 Sqmm 4 Core to 50 Sqmm 3.5 Core
14
-
-
... More
(c) 70 Sqmm 3.5 Core to 120 Sqmm 3.5 Core
12
-
-
... More
(d) 150 Sqmm 3.5 Core to 185 Sqmm 3.5 Core
6
-
-
... More
(e) 240 Sqmm 3.5 Core to 300 Sqmm 3.5 Core
2
-
-
... More
(f) 400 Sqmm 3.5 Core
2
-
-
... More
Labour for restretching/tightening the existing LT overhead conductors & GI earth wire mounted on insulators of any type on poles manually or by mechanical means to the extent of permissible sag and tension and binding with steel wires of appropriate size complete having 5 to 7 conductors per span of approx 35-40 mtr length. All as specified and directed by Engr-in-Charge.
4
-
-
... More
M&L in replacement aluminium conductor steel reinforced fixing on the over head LT pole with the help of aluminium tapes/ binding wire, taking down and complete all as specified as directed by the Engr-in-Charge
0.5
-
-
... More
M&L in replacement galvanised steel wire 4mm dia fixing on the over head LT pole with the help of aluminium tapes/ binding wire, taking down and complete all as specified as directed by th Engr-in-Charge
0.03
-
-
... More
Pruning/trimming of branches of trees interfering or overhanging electrical overhead lines in such a way to have a clearance of not be less than 2 mtrs from the outermost conductors on both side complete all as specified and directed by Engr-in-Charge (Span of conductor shall be measured from insulator to insulator without allowance for overlapping) All as specified and directed by Engr-in-Charge.
6
-
-
... More
Pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 100 mm height 65 mm dia 1100 volts grade including taking down complete all as specified and directed Make:BHEL/National
6
-
-
... More
Shackle type porcelain vitreous white brown or green insulator including one galvanised mild steel straps washers insulators bolts washers and nut as under 100 mm height 115 mm dia 1100 volts grade including taking down Engr-in-Charge Make:BHEL/National
6
-
-
... More
M&L for plain concrete cement PCC 1:4:8 type D2 for base and foundation (using 40mm graded coarse aggregate) for foundation of poles including necessary form work complete all as speified and directed
4.35
-
-
... More
M&L for PCC PCC 1:3:6 type C1 (using 20 mm graded aggregate) for coping of poles including fair finishing the exposed surfaces even and smooth without using extra cement including necessary formwork complete all as speified and directed
0.01
-
-
... More
M&L in replacement cross arms bracing supports clamps and back plate fabricated from structural steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one umder coat and one finishing coat of paint including taking down
0.6
-
-
... More
M&L in replacement steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts & screws as specified type SP-31 9 mtrs long complete all as specified and directed.
6
-
-
... More
M&L for preparation of existing surface of steel tubular pole by srapping down peeled off old paint, cleaning etc of length 8.5/9/11 mtrs and cross arms etc and applying one coat of aluminium coat paint including rewriting pole Nos as directed with black paint complete all as specified and directed by Engr-in-Charge.
40
-
-
... More
Dismantling the existing Air Circuit Breaker 630 Amps 3 phase 415 volts AC supply including disconnection of electrical and opening the system. Servicing the complete ACB including reassembling the same after repairing / servicing, testing and commissioning etc. servicing / maintenance and calibration & testing of relay any type by injecting fault current with testing equipment e.g. Earth fault relay/Over current relay,etc of breakers installed at different power distribution sub stns. The fault level setting of these relays shall be in such a way that individual breaker will activate / trip to arrest the fault in local circuit and fault will not travel to main breakers all as specified and directed.
2
-
-
... More
M&L for fixing of MCCBs in replacement of 63 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
5
-
-
... More
M&L for fixing of MCCBs in replacement of 100 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
6
-
-
... More
M&L for fixing of MCCBs in replacement of 125 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
5
-
-
... More
M&L for fixing of MCCBs in replacement of 160 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
3
-
-
... More
M&L for fixing of MCCBs in replacement of 200 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
3
-
-
... More
M&L for fixing of MCCBs in replacement of 250 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
3
-
-
... More
M&L for fixing of MCCBs in replacement of 400 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
3
-
-
... More
M&L for fixing of MCCBs in replacement of 63 Amps, 3 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
4
-
-
... More
M&L for fixing of MCCBs in replacement of 100 Amps, 3 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
5
-
-
... More
M&L for fixing of MCCBs in replacement of 125 Amps, 3 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
5
-
-
... More
M&L for fixing of MCCBs in replacement of 160 Amps, 3 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
5
-
-
... More
M&L for fixing of MCCBs in replacement of 200 Amps, 3 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
5
-
-
... More
Dismantling of Old Unserviceable/Burnt MCCBs 4 pole /3 Pole of any capacity complete all as specified and directed.
52
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized iron strip 32X6mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 part – I connected to machinery/equipment for Timer Panel etc. as required 32x6 mm dia galvanized iron with 40mm GI light Grade pipe for protection including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thick in PCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and 20mm bore GI watering pipe medium grade, etc. complete all as specified and directed.
15
-
-
... More
All as per item No 42.00 mentioned above but 4mm dia GI earth wire as Earth electrode complete all as specified and directed.
12
-
-
... More
M&L for fixing only existing LT street light Pole 8.5mtr/9mtr including earth excavation upto 1.65 mtr for Hard dense soil, PCC 1:4:8 type D2 40mm graded foundation .9mX.9mX.15m and .6mX.6m X 1.5m upto planting depth, PCC coping 1:3:6 type C1 20mm graded aggregate from ground level to 30m height and 15m thick around the pole etc complete all as specified and directed.
6
-
-
... More
M&L for refixing the Street Lights alongwith its all accessories i.e. Street light pole 1.2 mtr of 50mm dia , existing PVC cable connection from Junction Box to Street Light Pole etc, refixing of PVC Junction boxes complete all as specified and directed
6
-
-
... More
M&L for preparation of existing surface of LT Panel by srapping down peeled off old paint, cleaning etc of size upto 900mm X 400mm X 900mm (L X W X H) and applying primer on cleaned surface and applying Two coat of Siemens Grey Paint and Black paint on Angle Iron etc complete all as specified and directed by Engr-in-Charge.
15
-
-
... More
M&L for preparation of existing surface of LT Panel by srapping down peeled off old paint, cleaning etc of size upto 1000mm X 400mm X 1000mm (L X W X H) and applying primer on cleaned surface and applying Two coat of Siemens Grey Paint and Black paint on Angle Iron etc complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
M&L for preparation of existing surface of LT Panel by srapping down peeled off old paint, cleaning etc of size upto 1200mm X 400mm X 1200mm (L X W X H) and applying primer on cleaned surface and applying Two coat of Siemens Grey Paint and Black paint on Angle Iron etc complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
S&F LT Busbar Box, made of CRCA Sheet double door outdoor type factory made and assembled of size not less than 750x400x900(LXBXH) with 3.15mm thick CRCA Sheet , shall be provided 04 Nos Busbar of 400 Amp 50 KA and shall also be provided 4 Nos 40x40x5mm thick angle iron supports up to each 0.6 Mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth/floor mounting with fasteners, nut bolts etc as per site requirement complete all as directed by the Engr-in-Charge.
5
-
-
... More
S&F LT Busbar Box, made of CRCA Sheet double door outdoor type factory made and assembled of size not less than 450x150x450(LXBXH) with 3.15mm thick CRCA Sheet , shall be provided 04 Nos Busbar of 400 Amp 50 KA and shall also be provided 4 Nos 40x40x5mm thick angle iron supports up to each 0.6 Mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth/floor mounting with fasteners, nut bolts etc as per site requirement complete all as directed by the Engr-in-Charge.
8
-
-
... More
S&F testing, commissioning and installation in replacement Multifunction Meter LED ,Accuracy Class 1, with RS 485 Parameters V,A,F,PF,kW,kVA,kVAR,
kWh,kVAh,kVARh,Runhours,On Hours, Phase angle, Interrupts,THD, Events(High-Low), Neutral Current including suitable size of CTs etc complete all as specified and directed.
Make: Legrand/L&T/Schneider
5
-
-
... More
S&F in repair's flexible flat PVC insulated FRLS PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 25 Sqmm single core including jointing material and connection work, complete all as specified and as directed by Engr-in-Charge.
5
-
-
... More
S&F in repair's, flexible flat PVC insulated FRLS PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 16 Sqmm single core including jointing material and connection work, complete all as specified and as directed by Engr-in-Charge.
5
-
-
... More
S&F in repair's flexible flat PVC insulated FRLS PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 35 Sqmm single core including jointing material and connection work, complete all as specified and as directed by Engr-in-Charge.
5
-
-
... More
S&F in repair's flexible flat PVC insulated FRLS PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 50 Sqmm single core including jointing material and connection work, complete all as specified and as directed by Engr-in-Charge.
5
-
-
... More
S&F galvanised or codmium plated high tensile Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long of 5 to 10mm dia of neck complete all as specified and as directed
3
-
-
... More
All as per item No 56.00 mentioned above but n exc 11 to 15mm dia of neck complete all as specified and as directed
2
-
-
... More
All as per item No 56.00 mentioned above but n exc 16 to 20mm dia of neck complete all as specified and as directed
2
-
-
... More
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and as directed
20
-
-
... More
S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning of capacity TPN 16 To 32 AMP complete all as specified and as directed
10
-
-
... More
S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning of capacity TPN 40 To 63 AMP complete all as specified and as directed
10
-
-
Evaluation Notes How It Works ?