Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 86,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_547696_1Bid Award Id
ViewTender No
GE (N) BKN TOKEN NO 49 /2022-2023Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolition of brick or stone masonary including all necessary arches, pillars, quions etc built in cement mortar.
35
-
-
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished indentical to existing finish without any extra cost to Govt), all as specified and directed by Engineer-in-Charge.
26
-
-
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished indentical to existing finish without any extra cost to Govt), all as specified and directed by Engineer-in-Charge.
30
-
-
Demolition of cement concrete in ground floor and pavings n.exc 15cm thick below or above ground level including tiles and similar works complete all as specified.
25
-
-
Taking down door shutter of any desc exc 1 sqm but not exc 2 sqm and refixing in the same opening after easing, adjustment and repair
5
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
1000
-
-
Taking up or down steel tubing 15 mm bore with connections for cleaning for refixing or removing to store yard complete all as specified
60
-
-
Taking up or down steel tubing 20 mm bore with connections for cleaning for refixing or removing to store yard complete all as specified
100
-
-
Dismantling water tanks and removing to store 500 lit to 1000 litr
2
-
-
M&L half brick work with fly ash briks old sized, straight or curved on plan to any radius buildt in CM 1:4 all as specified and directed
26
-
-
M&L for brick work with fly ash bricks old sized, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6.
32
-
-
M&L for pre painted galvalume aluminium zinc cozting GI based corrugated steel Sheet high rib profile tile pattern color coated 0.5 mm thick of 550 Mpa Tensile strength sheets as in roof covering and fixed as per manufacturers instruction (design as app by Engg in charge complete all as spfd ) Make :- TATA/JSW
935
-
-
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridge as specified
65
-
-
S&F Composite cement ceiling board 4 mm thick in ( 595 mmX595 mm ) pannel (Make-everest ramco or eql.) designer ceiling pre finished conforming to IS 14862 type B cateogory three incl GI frame , grid work,hold fast,suspended with suspender along with holding down bolt complete . (Note: Ceiling board shall confirming to IS-14862 ,shall be fire resistant , Moisture resistant and ceiling shall be suspended with suspenter and adjuster)
600
-
-
M&L for 15mm thick rendering on fair faces of brick surfaces finished even and smooth W/O using extra cement in cm 1:4 complete all as specified and as directed by Engineer-in-Charge.
650
-
-
M&L for 10mm thick rendering on brick or concrete surfaces in cm 1:6 finished even and smooth w/o using extra cement all as specified.
750
-
-
M&L for providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
220
-
-
M&L PCC 1:3:6 type C-2 20 mm graded stone aggregate as in foundations, filling and mass concrete , sub base complete all as spfd and as directed by engineer in charge
5
-
-
M&L for 40-50mm thick sand stone slab not exc 2mtr in length, punched dressed self faced set and pointed in CM 1:4 as in sun-shades, chajjas, shelves, cills landings, cover stone including cutting chasing as directed
25
-
-
Jodhpur stone of roof slab self faced 7.5cm to 10 cm thick 25 to 35 cm wide hoisted and set jointed and grouted in cement and sand mortar 1:6 comp.all as specified.
2
-
-
M&L cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foudation, filling, sub base and mass concrete all as specified.
24
-
-
M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 laying floor finishes complete all as specified.
810
-
-
M&L for machine cut kota stone flooring 20-25mm thick over cement screed base laid and jointeed with pigment to match the shade of the slab including rubbing and polishing all as spd and as directed by Engineer-in-charge.
650
-
-
M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
45
-
-
Cutting to existing kota stone flooring and polishing grinding upto mirror finish complete
200
-
-
M and L for white or coloured Non skid ceramic tiles exc 0.11 Sqm and nexc 0.18 Sqm , 7mm thick in floors set and jointed in neat cement slurry and pointed in coloured cement to match the floor laid over 15mm thick screed in cement mortar 1:6.
160
-
-
All as per item above but on vertical surface as in dado/skirting.
20
-
-
S&F 500 ltr Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, 450 ltr Capacity, including Ball brass valves, high pressure, with polythene float and flynut com
2
-
-
S&F in repair chromium plated Bib Tap, with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule, fancy type, CP, 15mm dia
6
-
-
Mild steel framed work such as grills, gratings, tank staging etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks, cooler stand and similar work conforming to Fe 290 Gd E-165 all as specified .
100
-
-
Dismantling structural steel work as in trusses nexc 10.00 mtr span .
2
-
-
Dismantling timber scantling 40 sq cm and over in section, in any position complete.
1
-
-
M&L steel work in tubular trussess/ purlins incl spl shaped washer etc. using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240. complete all as specified and directed by Engineer-In-Charge.
400
-
-
S&F Mild steel bolts.exc. 5 cm length not exc. 10 cm length (machine made) with hexagonal or square heads at one end and screwed the other , or screwed both ends, each screwed end to be fittied with washers and one hexagonal or square nut 11 to 15 mm neck dia complete all as specified and as directed by engineer-in-charge.
50
-
-
Erection and fixing only steel work in roof trusses including special shape washers et. Complete.
2000
-
-
M&L for hardcore of gauge nexc 63mm , deposited , spread and levelled in layers nex 15cm thick watered and rammed to a true surface
24
-
-
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and fair complete all as specified.
160
-
-
M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types as in platform Complete all as specified and directed
5
-
-
S&F 1.25 mm thick Pressed steel frames of size 125mm x 60mm for single doors including necessary fixing lugs, hinges, lock strike plate, etc complete all as per IS provns.
100
-
-
S&F 1.25 mm thick Pressed steel frames of size 105mm x 60mm for single doors including necessary fixing lugs, hinges, lock strike plate, etc complete all as per IS provns.
35
-
-
M&L for providing cement concrete 1:3:6 type C-0 using 20mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified.
0.75
-
-
S&F 35mm thick Factorymade second class hard wood plain framed pannelled shutter (two panels and double shutter) with lock rail and pannel or 9mm BWP comerical ply or 12mm venered particle board with comerical face venering on both faces. The size of rail and style as per IS-1003 part kilin seasoned
56
-
-
S&F 2nd class hardwood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass guage, etc. (without sash bars), edges of framing plain, chamfered or rounded. Fitted with cut and mitred beads for securing glass,etc. sizes of members of shutters as specified in SSR Part I, section 8, clause 8.24(a); supplied and fitted to chowkhats complete all as specified and as directed by Engineer-in-charge.
42
-
-
S&F mild steel barrel tower bolt, stove enamelled black with bright bolt of 150 mm complete.
92
-
-
S&F mild steel sliding door bolts plate type stove enameled black with bright bolt not less than 12 mm dia with and incl. a minimum of 6 bolts and nuts four on bolt plate and two on staple plate of 300 mm long complete all as specified and as directed by Engineer-In-Charge.
26
-
-
S&F MS pressed handle oval type stove enamel block with bright bolt of 150 mm. complete.
150
-
-
S&F brass 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed by engineer-in-charge.
30
-
-
S&F pressed steel window (box type) factory made glaged and guaged with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded incl a prov of cooler / Ac opening with shutter including one shop coat of red oxide primer complete all specified.
Note : i) The window shall be fabricated as per Drg No CEBZ/888R & 889 Sheet 1 to 4. ii) MS fillets, glazing, wire gauge shall be measured and paid separately. iii) opening incl provn shutter for cooler to be provided
35
-
-
S&F 4 mm Sheet glas ordinary quality and glazing with oil putty in square n exc. 0.5 sqm in each pane complete all as specified and as directed by Engineer-in-Charge.
40
-
-
M&L Galvanised stain less steel wire cloth 0.56 mm nominal dia of wire anfd averqagae width of aperature 1.18mm and fixed with tinned tracks, or galvanised wire spaples.
80
-
-
Do but fixed as in repairs .
15
-
-
M & L 15 mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
90
-
-
M & L 20 mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
160
-
-
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand including brackets & waste pipe etc complete all as specified.
6
-
-
S&Fin repair 15mm bore PVC connection with PTMT nuts length 450 mm
6
-
-
S&F in repair fancy type chromium plated stop valve/Angle valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions chromium plated of size 15 mm. all as specified
6
-
-
S&F in repair Towel ring of PTMT with and incl chromium plated brass screws and wooden /plastic cleats
6
-
-
S&F in repair 600X450 mm bevelled edge mirror of selected quality glass moulnted on 6mm AC building board or commercial ply complete all as specified & directed by Engg-in-charge
6
-
-
S&F in repair 32 mm size cp waste coupling (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) incl waste pipe
6
-
-
S&F in repair soap dish Make Jaquar/ cera or eqivalent
6
-
-
S&F 75 mm bore CI floor trap plain with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
6
-
-
Pillar taps, 15mm dia, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, long screwed shanks and fly nuts, screwed for iron pipe and fixed in repairs.MAKE: JAQUAR OR EQUIVALENT
6
-
-
PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring jointed fixed to floor/walls..
60
-
-
PVC (SWR) pipes 75 mm bore, single socketed, in any length with rubber ring jointed fixed to floor/walls.
52
-
-
S&F in replacement curtain rod 20mm dia, mild steel, chromium plated, fancy type with fixing brackets and knobs at both ends as per site requirement complete all as specified and directed by Engr-in-Charge Note :- The cost of brackets and knobs is deemed to be incl in the quoted rate. Nothinbg extra shall be paid on this account.
60
-
-
M&L for prep of new plastered and unplastered surfaces of walls by applying a 3 mm thick thin layer of Birla white putty to give uniform surface applying coat of oil bound distamper on walls old decorated surfaces of desired finish as app by Eng-in-charge in any position
750
-
-
M&L Complete removal of existing treatment of walls and applying two coats of oil bound distemper over a thin coat of wall care putty complete all as specified and as directed by Engineer-in-Charge.
50
-
-
M&L for Preparing new/old platered surface and applying two coats of white wash on wall complete all as specified and as dircted by Engineer-In-Charge.
200
-
-
M&L for prep of new plastered and unplastered surfaces of walls and applying two coat of Cement Base Paint on walls oover a coat of alkaili resistant priming paint by Eng-in-charge in any position
650
-
-
M&L Complete removal of existing treatment of walls and applying two coats of cement based paint complete all as specified and as directed by Engineer-in-Charge.
50
-
-
M&L for preparation of steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint of Red oxide zinc chrome primer all as specified.
150
-
-
Do but one coat on old decorated surfaces.
10
-
-
M&L for two coats of synthetic enamel paint on new wooden surfaces incl prep over a coat of pink primmer.
130
-
-
Demolition of cement concrete as in floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
6
-
-
M&L hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layer n exc. 15 cm thick watered and rammed to a true surface
6
-
-
M&L for 75mm thick PCC (1:4:8), type C2 using 40mm graded stone agg as in sub base of floors etc finished even and rough complete all as specified and directed.
36
-
-
M & L for Screed bed or bedding layer of mortar(1:6) 15mm thick for laying floor finishes complete all as specified and directed.
36
-
-
M&L Chequered cement concrete tiles 20cmx20cmx25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigment complete all as specified and directed.
36
-
-
M&L for PCC (1:4:8) type D2, using 40mm graded stone agg as in mass filling and fdn complete all as specified and directed.
2.5
-
-
M&L for Brick work with fly ash bricks old size straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed by Engr-In-Charge.
1
-
-
M&L for 15mm thick Rendering in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished fair and even complete.
11
-
-
Taking down carefully existing unserviceable Copper/aluminum batten/surface conduit/concealed conduit point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc (including old MS sunken boxes) and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc complete all as specified and as directed by the Engr-in-Charge.
76
-
-
Taking down of unserviceable DBs/switch fuses/changeover in sheet steel enclosure complete with MCBs/Fuse/grips any capacity and removing from site and making good disturbed surface of wall, floor etc. Taking after disconnecting all cable complete all as specified and as directed by the Engr-in-Charge.
9
-
-
Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including new non-metallic rigid PVC concealed conduit, not less than 20 mm dia, medium duty ISI marked, including conduit fittings such as tees, bends etc terminating in and including new sunken box covered with and including 3 mm thick bakelite laminated sheet top cover of approved make for one fan or light or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, multi stranded as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
76
-
-
All as per item No 83 here-in-before but socket point on the same board with other switches complete as specifed as directed by Engineer - In - Charge
14
-
-
All as per item No 83 here-in-before but socket point on independent board complete as specifed as directed by Engineer - In - Charge
12
-
-
All as per item No 83 here-in-before but cable 2.5 Sqmm for 15 Amps switch socket outlet on independent board complete as specifed as directed by Engineer - In - Charge
12
-
-
S&F Switch piano flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge S&F Socket outlet 2 in 1, 3 pin, 5A ISI marked, complete all as specified and as directed by Engineer-in-Charge
96
-
-
S&F Socket outlet 2 in 1, 3 pin, 5A ISI marked, complete all as specified and as directed by Engineer-in-Charge
20
-
-
S&F switch socket combination 5 in 1, 5/16 amp flush type fixed on laminated sheet top cover (laminated sheet top cover is including in point wiring).
12
-
-
S&F Lamp holder insulated body with back plate for conduit/casing capping fittings complete all as specified and as directed by Engineer-in-Charge Make : CG/Havells/Phillips.
26
-
-
S&F Ceiling rose PVC/poly carbonate insulated body three terminal ISI marked, complete all as specified and as directed by Engineer-in-Charge.
14
-
-
Supply & fix LED bulk head ,09W / 10 W, IP65 diacast aluminium housing powder coating finished complete all as specified and directed by Engineer-in-charge.Make : CG / havell's / Phillips.
14
-
-
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louver
12
-
-
Sheet metal enclosure for distribution boards, suitable for fixing MCBs 240 volts with 200 Amps rated bus bar, SPN, 4 ways double door , supplied and fixed in repair, including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make - Legrand/ GE/Seimens/L&T/Schneider/Indo Asian/C & S/Strandard/BCH/HPL
14
-
-
S&F MCB single pole, 240 volts of rating 6-32 Amps, breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge Make : Legrand / Schneider / ABB/ Havells
26
-
-
MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens/L&T/Indo Asian/C&S/ABB/BCH /Havells
14
-
-
S&F Decorative ultra slim linear LED lightening fixture, energy efficent 18 Watt complete all as specified and directed by engineer-in-charge.Make SYSKA/BAJAJ/PHILIPS/C.G/wipro
30
-
-
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.00 sq mm 2 core
100
-
-
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 mtr in depth for route of cable and getting out complete all as specified and as directed by the Engr-in-charge.
27
-
-
Returning, filling in soft/loose soil including spreading, leveling watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engr-in-charge.
15.3
-
-
Removing of surplus soil to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
11.7
-
-
Protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class 'B' bricks complete all as specified and directed by Engr-in-charge.
0.8
-
-
Local tibba dry sand cushioning for protection of cable complete all as specified and as directed by Engineer-in-charge. Note Local approved tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning.
8.1
-
-
M & L GI tubing light grade for protection of cables with pole/ in ground of size 40mm dia complete all as specified and as directed by Engineer-in-Charge.
6
-
-
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I.
17
-
-
Supply and fix steel tubular swaged poles type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping .
14
-
-
Supply, laying and testing Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power under ground cable ( heavy duty) with aluminium conductor, 1100 volts LT grade of cross-sectional area 10 Sqmm 4 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid in repair including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.(ii) Road manually cutting/floor cutting/cutting holes etc in wall required for laying /fixing of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same)
500
-
-
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge.
96
-
-
Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge.
57.6
-
-
Removing of surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge.
38.4
-
-
Material & Labour for sand cushioning using clean local tibba fine sand for under ground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified.
(Note Punned thickness shall be considered for payment purpose)
28.8
-
-
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified.
0.4
-
-
Boring of holes 110 mm dia, manually without disturbing the top surface for laying of cables/GI pipes under road , pavement, hard standing complete all as specified and as directed by the Engineer-in-Charge.
10
-
-
Supply and fix galvanized iron pipe 40 mm light grade ISI Marked complete for cable protection and LED brackets, laid in trenches, floors, fixed to walls, pole with suitable FI clamps complete all as specified and directed ISI marked.
21
-
-
Suppy and Fixing LED based street light, housing made up of LM6 pressure die cast aluminium alloy with effectie thermal management, sturdiness. The fixture should have a minimum system efficiency of more than 100 lumen/watt and a minimum system lumen output of not less than 4500 lumens and maximum system wattage 45 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be wthstand up to 440v for 8hrs, two surge proection not less than 5KV one on driver and one external surge protection, PF0.95 and THD10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory. Make:- CG/Phillips/Wipro
14
-
-
Supply and fixing thermplastic cable junction box with IP 66/67 weather prrof protection for outdoor installation with knockouts for cable entry of size 205x255x122 mm suitable for LT UG cable 10 Sqmm to 25 Sqmm Make Hensel / Sintex
14
-
-
Supply & fixing FRLS PVC insulated Copper conductor, two single core of size 1.5sqmm complete for terminal box to street/ flood light fitting.
98
-
-
Supply,fixing, testing and commissioning electric storage water heater (Geyser) vertical type with glass lined tank of capacity 25 Ltrs, BEE and minimum 5 Star Rating on wall including grouting suitable size of nuts, bolts and washers and making good the surfaces of walls to match with the existing surface including PVC connection, transportation up to site complete all as specified and directed by Engineer in charge.
22
-
-
M&L new sub main wiring with 2 single core, multi-stranded PVC insulated cable unsheathed 1100 volts grade with copper conductor of size 4 sq mm drawn in and including PVC conduct /casing capping including earth continuity conductor cable of size 2.5 sq mm PVC insulated unsheathed copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.
440
-
-
Supply & fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 Volt. complete all as specified and directed by Engineer in charge.
22
-
-
Supply and fixing stop cock cast iorn fency chromium plated type for 15mm bore GI pipe complete all as specified and directed by Engineer in charge.
44
-
-
S&F bib Tap fency chromium plated type, 15mm bore, cast cooper alloy with crutch or butterfly handle, screwed for iron pipe complete all as specified and directed by Engineer in charge.
22
-
-
Supply and fixing GI pipe 15mm medium grade with all fittings complete all as specified and directed by Engineer in charge.
440
-
-
Supply and fixing GI pipe 20 mm medium grade with all fittings complete all as specified and directed by Engineer in charge.
200
-
-
S&F sheet metal enclosure DB 12 way, SPN single door with 200 rated bus bar complete all as specified and directed by Engineer in charge.
10
-
-
S&F sheet metal enclosure DB 2 way, SPN single door with 200 rated bus bar complete all as specified and directed by Engineer in charge.
22
-
-
S&F MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
32
-
-
Supply and laying or fixing or passing through pipe, stranded conductor 1100 volts grade heavy duty cable, two single core, with PVC insulated aluminium conductor served with an inner sheahing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq mm nominal cross section in service connections.
594
-
-
Supply and laying or fixing or passing through pipe, stranded conductor 1100 volts grade heavy duty cable, three single core, with PVC insulated aluminium conductor served with an inner sheahing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq mm nominal cross section in service connections.
100
-
-
Supply and fix Rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fix in position all as specified
7
-
-
Supply and fixing Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ballscrewed for iron pipe and fixed. (Minimum weight 15mm-142gms/2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm-690gms
7
-
-
Supply and fix Nipple suitable for HDPE water tank.(Minimum weight 15 mm-38gms/20mm-45gms /25mm- 65gms)
14
-
-