Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date10 Nov 2023
Closing Date30 Nov 2023
Tender Amount₹ 49,15,000
Costs
EMD
₹ 98,300Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Provn Of Certain Work Services In Jfs Test Cell And Certain Minor And Other Sanctioned Works
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_627966_1Bid Award Id
ViewTender No
8620/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S & F flame proof, weather proof exhaust fan 380 mm sweep, class 1, Zone 1, single phase 1440 RPM, rated 240 V, 50 cycle with CMR/CPRI hazhardous area gas group of IIA / IIB with fabricated construction casing suitable propeller wheel with dynamically balanced blades to avoid frictional spark hazardous front and rear guards 01 No, M-20 cable entry etc suitable for wall/bracket mounting arrangement etc duly dark grey epoxy powder coated as per shade 632 of IS -5 including writing MES No in 2 Cm height with synthetic enamel paint complete all as specified and directed.
1
-
-
Note for Item No 4:-
The quoted rate is deemed to be inclusive for cutting holes in wall of any type suitable to fix the exhaust fan and making the disturbed wall surfaces good by rendering in cement mortar 1:4 and necessary painting.
-
-
-
S & F Air Termination Single Pointed Aluminium Rod dia upto 12mm and length upto 300mm complete all as specified and as directed.
4
-
-
S & F Aluminium strip 25 x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
35
-
-
M&L earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt Magnesium Sulphate (1 : 1: 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion, complete all as per specified and as directed.
4
-
-
Note for Item No 8:-
(a) All Joints should be joined by Exothermic Welding or Brazing.
-
-
-
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
-
-
-
(c) Earth resistance tester will be provided by the contractor. It should be calibrated from authorised company/ lab..
-
-
-
(d) After testing if desired earth resistance of less than 3 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
-
-
-
(e) The quoted rate shall deemed to be inclusive for GI strip 32mm x 6mm and protection pipe of length up to 7.5m. The GI strip beyond 7.5 m shall be measured and paid seperately under relevant item here-in-after.
-
-
-
S&F Galvanised earth strip of size 32 x 6mm fixed on proper post insulator at the instrument end complete all as specified and directed.
25
-
-
Supply and fix GI pipe 40 mm bore light grade as supporting pipe for air termination rod with necessary cutting and fixing arrangements fo fix with roof including necessary Concrete foundation etc complete all as specified and as directed by Engr-in-Charge.
4
-
-
S & F Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw complete all as per specified and as directed.
4
-
-
S & F Epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and as directed
20
-
-
Supply and fixing in repairs movement detector for lighting control system with 180-360 degree detection angle, complete all as directed.
Make:- Legrand cat part No. 0488 17 or equivalent of Schnieder/ Siemens
50
-
-
Supply and fixing in repairs power contactor 25 Amp for lighting control swiches conforming to IEC/EN 61095 complete all as directed.
make:- Legrand cat part No.4125 44 or Schnieder/ Siemens
50
-
-
S&F in repairs factory made powder coated distribution board SPN, 2 way single door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified.
50
-
-
M & L for Sub main wiring for circuit complete with 2 runs of 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and including suitable size PVC Casing capping and accessories complete fixed surface to wall/roof/ceiling etc and including 1 run of 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring complete all as specified and directed.
220
-
-
Note for Item No 21:-
(a) 2 runs of 1.5 sqmm cable along with 1 run of 1.5 sqmm cable for earth conductor and PVC casing and capping shall be measured as one length.
-
-
-
Supply, installation, testing and commissioning of high quality standalone integrated full diffuser LED with PIR sensor, Troffer with a min system lumen of 3600 Lm (+/- 100 Lm tolerance) and system wattage not exceeding 36W (+/-5% tolerance) with an efficiency 100 lumen /watt. CCT of 6500K with SDCM of 5 and CRI 80 including taking down existing LED sensor light complete all as specified and directed.
Make :- Philips RC 383B LED 36S-6500 PSU OD WH PIR or similar in OSRAM/GE
65
-
-
Note for Item No 23:-
Technical specifications of the sensor light LED is as follows:-
(a) The housing should be of high quality CRCA & PS diffuser with PF 0.95 and THD = 10% input voltage range of 140-270V
-
-
-
(b) Lifetime of 50000 hours @ L70. Product should be suitable for continuous operation (14-16)hrs per day)m
-
-
-
(c) The LED light Engine (PCB) should be rectangular /square boards and not strip type, should be FR4 with 1mm thickness with more than 300 LEDs symmetrically mounted over it to maintain the optical and thermal stability of the system over the life time
-
-
-
(d) The sensor should be a motion detector and should be a connected with a digital interface to the led driver and it can be converted to a standard luminaire if this interface is not connected
-
-
-
(e) (plug and play device) The time delay in the sensor should be min 15 (+5) mins. The coverage of the sensor should be 1.5m radius when installed in height of 8 ft
-
-
-
(f) The luminaire should be class B serviceability (Driver needs to be separate and can be changed at site. The same family of luminary should be available in the both the version high Lumen (3600 Lm) and Low lumen (2800 Lm)
-
-
-
(g) The LED used in the luminaire shall be only of LG innotech, Lumileds APT Electronics , Nichia and CREE & no other make. The driver should have min of 3KV surge/burst protection.
-
-
-
(h)Standby mode power of the system should be less than 1 watt avg. Driver should be protected for open circuit & short circuit protection for LED side.
-
-
-
(j) Standby mode : when the occupancy sensor has turned off the luminaire.
-
-
-
S & F in repairs CRCA housing of size 2'x2' suitable for mounting the LED light on ceiling with all accessories and fittings complete all as specified and directed.
65
-
-
M&L point wiring using approved colour coding as per IS with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC conduit fixed on surface of wall, columns etc including PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) copper conductor as earth wire and connected to earth dolly for One light point/fan/bell point controlled by one switch complete all as specified and directed.
16
-
-
S & F modular switch 1 way 6 amp.1 module complete all as specified and directed.
16
-
-
S & F modular Socket, 6A - 2/3 pin combined, 2 module complete all as specified and directed.
16
-
-
S & F modular white cover plate with frame, 3 module complete all as specified and directed.
16
-
-
S & F modular Metal flush box, 3 module complete all as specified and directed.
16
-
-
S & F wall mounted fan 400 mm sweep, power input 55 watt ,1380 RPM, air delivery-75 CMM, single phase 230 volts high performance motor with over heat protection world class styling & finish, facility to control wind & nature mode, aerodynamically designed balanced AS blades including fixing arrangement on wall complete all as specified and directed. Make:- Havells Model -Sameera/ Usha - Max Air Super/ Crompton Greaves.
16
-
-
S&F factory made powder coated distribution board SPN, 8 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified.
2
-
-
S&F factory made powder coated distribution board SPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified.
4
-
-
Supply & fix single pole neutral, MCB 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
6
-
-
Supply & fix single pole MCB 6 to 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
12
-
-
M & L for Sub main wiring for circuit complete with 2 runs of 4 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and including suitable size PVC Casing capping and accessories complete fixed surface to wall/roof/ceiling etc and including 1 run of 4 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc complete all as specified and directed.
92
-
-
Note for Item No 44:-
(a) 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and PVC casing and capping shall be measured as one length.
-
-
-
Supply and installation of Clean Agent Based Standalone (Modular) Fire Suppression system HCFC 123.5 Kg MS SP Red with following specifications complete all as specified and directed.
Make :- Ceasefire/ Apollo/ Honey well (Morley)
5
-
-
(i) Capacity:- 5 Kg
-
-
-
(ii) Gross weight - 7.7 Kg
-
-
-
(iii) Empty weight - 2.7 Kg
-
-
-
(iv) Can Height - 264 mm
-
-
-
(v) Diameter - 240 mm
-
-
-
(vi) Discharge Time - 8 Sec
-
-
-
(vii) Discharge Mechanism - Automatic
-
-
-
(viii) Applicable on class A,B,C and electrically started fire
-
-
-
(ix) Can Construction :- Deep drawn & Co2 mig welded
-
-
-
(x) Valve Construction :- Forging & machining
-
-
-
(xi) Internal coating of can :- Epoxy powder coated
-
-
-
(xii) External coating of can :- Epoxy polyester powder coating
-
-
-
(xiii) Tests: Helium leak detection
-
-
-
(xiv) Sheet metal thickness :- 1.60mm
-
-
-
(xv) Warranty - The contractor shall submit warranty certificate for a period of 6 years from the date of completion.
-
-
-
Supply and installation of Modular clean room sandwiched wall panel made of 1 mm thick powder coated GI sheet on both sides and filled with Rock wool of density not less than 96 kg/cum along with GI sections for reinforcement along the periphery, suitable floor track and fixing accessories. The panel will be of profile type wall panel and overall thickness shall be 50mm and colour of the wall panel will be RAL-9002 complete all as specified and directed. Make: CG AIR TECH or equivalent make approved
93
-
-
Supply and installation of Modular clean room sandwiched non-walkable ceiling panel made out of 1mm thick Powder Coated GI sheet on both sides and filled with Rock wool of density not less than 96 kg/cum along with GI sections for reinforcement along the periphery with supports and fixing accessories. The panels will be Profile type ceiling Panel and overall thickness shall be 50mm & Colour of the ceiling panel will be RAL-9002 complete all as specified and directed. Make: CG AIR TECH or equivalent make approved
30
-
-
Note for Item No 62 & 63:-
The quoted rate is deemed to be inclusive for installation of flashing for wall panel & ceiling panel like bottom track/' L' anlge/ Self thread. Silicon sealeant / frisher Etc.
-
-
-
Supply and installation of Cleanroom AL powder coated coving (wall to wall and ceiling to wall R-50 mm coving) complete all as specified and directed
175
-
-
S & F Corner Cups made of powder coated aluminium to cover up the corner joints of wall and ceiling panels complete all as specified and directed
16
-
-
S & F Single Leaf sandwiched door of overall size 1000mm X 1850mm X 50mm fabricated with 1 mm thick epoxy powder coated galvanised iron sheets on both sides and infilling of paper honey comb, frame of 1.2mm jam depth of door shutter in line with adjacent panel thickness and shutter width of 44mm along with following accessories complete all as specified and directed.
1
-
-
Note for Item No 67:- The following accessories are part of door and the quoted rate is deemed to be inclusive for the following:-
a) Stainless steel hinges - 03 Nos
b) Stainless steel D type handles - 02 Nos
c) Stainless steel push plates on push side with 0.8mm thick - 01 No. d) Heavy duty door closure - 01 No e) Double glazed view panel with bullet proof glass of 6mm thick with triangular clips and silicon sealant of size (300mm x 500mm)- 01
f) Mortice dead lock (ML 100D) with two side key operation cylinder
g) Tower bolt - 02 Nos
-
-
-
S & F Double Leaf sandwiched door of overall size 2000mm X 2330mm X 50mm fabricated with 1 mm thick epoxy powder coated galvanised iron sheets on both sides and infilling of paper honey comb, frame of 1.2mm jam depth of door shutter in line with adjacent panel thickness and shutter width of 44mm along with following accessories complete all as specified and directed.
1
-
-
Note for Item No 69:- The following accessories are part of door and the quoted rate is deemed to be inclusive for the following:-
a) Stainless steel hinges - 03 Nos/leaf
b) Stainless steel D type handles - 02 Nos/leaf
c) Stainless steel push plates on push side with 0.8mm thick - 01 No/leaf. d) Heavy duty door closure - 01 No/leaf e) Double glazed view panel with bullet proof glass of 6mm thick with triangular clips and silicon sealant of size (300mm x 500mm)- 01 No/Leaf
f) Mortice dead lock (ML 100D) with two side key operation cylinder
g) Tower bolt - 02 Nos/leaf
h) Stainless steel kick plates of 1.2mm thick with 300mm height for material transfer
-
-
-
Excavating in post holes (or similar holes) each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good surface as in hard / dense soil complete all as specified and as directed.
16
-
-
M & L Cement concrete 1:4:8 type D-2 using 40mm stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed
3.46
-
-
S & F Steel work in tubular trusses/ post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St.-240 complete all as specified and as directed
2072.04
-
-
M&L 5mm thick MS Plates (Plain or chequered) channels (confirming to Fe 410 W Gde E-250 A quality), square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed
169.34
-
-
M&L for Joist, channel, angle, or tee sections, fixed independently (confirming to Fe 410 W Gde E-250 A quality), without connecting plates, etc. complete all as specified and as directed
133.76
-
-
S&F Pre painted Coloured corrugated Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
122.64
-
-
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
17.52
-
-
Note for Item No 76 & 77:- (Pre-painted coloured Galvalume roofing) :-
-
-
-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
-
-
-
(ii) The contractor shall ensure that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
-
-
-
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
-
-
-
M&L MS flat iron wind ties (4mm thick 40mm wide) for roof including securing bolts including all necessary drilling, bolting or riveting, etc. , and similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
73.58
-
-
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mm complete all as specified and directed.
14
-
-
M&L Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
117.22
-
-
Note for item No 84 :-
(a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
-
-
-
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
-
-
-
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
-
-
-
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
-
-
-
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
-
-
-
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
-
-
-
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
-
-
-
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
-
-
-
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
-
-
-
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
-
-
-
Demolition of brick work built In cement mortar,including all quoin, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed.
2.5
-
-
M&L False ceiling using GI snap grid size 60x60cm with main runner 38x24,wall angle & cross tee 29x24mm wall angle 24x24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm with and including 4mm thick designer ceiling board complete all as specified and as directed.
77.3
-
-
M & L Powder coated aluminium work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/ stainless steel screws, all complete as specified and directed.
475
-
-
S & F Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
8.4
-
-
Note for Item No 97 & 98:
The thickness of the powder coating shall be of minimum 50 micron
-
-
-
Supply and Fix 4.8 mm thick plain sheet glass ordinary quality and glazed with oil putty in square of glass exc 0.5 sqm each pane complete all as specified and directed.
40
-
-
M & L 9 mm thick Pre-laminated particle board, interior Grade, pre-laminated both side with decorative choice lamination fixed with screws to timber frame work complete all as specified and as directed.
40
-
-
Supply and fixing 300 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed.
3
-
-
S&F Aluminium body door closer hydraulically regulated,designation No.3, universal type, suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed by Engr-in-charge.
3
-
-
S&F Floor door stopper of brass body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete all as specified and as directed.
3
-
-