Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 8,920Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_643900_1Bid Award Id
ViewTender No
8554/A/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F in renewal of running capacitor 50 mfd for split type AC's of capacity 1.5/2.0 TR complete all as specified and directed.
20
-
-
S&F in renewal of indoor blower fan motor, single phase, 230 Volt of split type AC Suitable for 1.5 TR capacity complete all as specified and directed.
15
-
-
S&F in renewal of indoor blower fan motor, single phase, 230 Volt of split type AC Suitable for 2.0 TR capacity complete all as specified and directed.
10
-
-
S&F in renewal of burnt compressor of capacity 2.0 TR of split type AC unit and re-fixing the same after renewal from the company make original compressor as per existing Make & Model of rotary type including gas charging complete all as specified and directed.
Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the unit quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
5
-
-
S&F in renewal of burnt compressor of capacity 1.5 TR of split type ACs unit and re-fixing the same after renewal from the company make original compressor as per existing Make & Model of rotary type including gas charging complete all as specified and directed.
Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the unit quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
5
-
-
M&L for repair to leaking area of split type AC unit of capacity 2.0/1.5 TR including dehydration, gas charging of gas R22/R410A/R-32 as applicable, pressure check & testing complete all as specified and directed.
Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the unit quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
38
-
-
S&F in renewal of air filter of indoor unit for split type AC units of capacity 1.5/2.0 TR as per existing Make & Model complete all as specified and directed.
20
-
-
S&F in renewal of insulation for Split AC Copper Tube 5/8 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed.
50
-
-
S&F in renewal of insulation for Split AC Copper Tube 1/2 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed.
50
-
-
S&F in renewal of insulation for Split AC Copper Tube 1/4 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed.
50
-
-
S&F in renewal of 3 core copper PVC insulated FRLSH cable of size 4.0 Sqmm, flexible cables, 1100 Volts and confirming to IS: 694 complete all as specified and directed.
100
-
-
S&F in renewal of suction line (1/4") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
25
-
-
S&F in renewal of discharge line (5/8") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
25
-
-
S&F in renewal of discharge line (1/2") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
25
-
-
S&F in renewal of PCBs indoor/ outdoor units as per existing Make & model for Split type AC of Capacity 2.0 TR/ 1.5 TR complete all as Specified and Directed.
15
-
-
S&F in renewal of Flexible PVC drain pipe of size 15mm bore & suitable for Split type AC of Capacity 1.5/2.0 TR complete all as specified and directed.
100
-
-
S&F in renewal of outdoor unit fan blade as per existing Make and model suitable for Split type AC of Capacity 1.5 TR complete all as Specified and directed.
5
-
-
S&F in renewal of outdoor unit fan blade as per existing Make and model suitable for Split type AC of Capacity 2.0 TR complete all as Specified and directed.
5
-
-
S&F in renewal of outdoor unit condenser fan motor as per existing Make & model suitable for 1.5 TR capacity air conditioner complete all as specified and directed.
5
-
-
S&F in renewal of outdoor unit condenser fan motor as per existing Make & model suitable for 2.0 TR capacity air conditioner complete all as specified and directed.
5
-
-
M&L for shifting of Split AC's of capacity 1.5/2.0 TR with indoor, outdoor including all connected accessories after pumping down the gas and , refitting, topping up the gas, testing and commissioning complete all as specified and directed.
4
-
-
S F in renewal of brass flare nut 5/8 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
3
-
-
S&F in renewal of brass flare nut 1/2 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
3
-
-
S&F in renewal of brass flare nut 1/4 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
3
-
-
M&L for repair / servicing of existing UPS incuding dismantling electric connection and cleaning of realy junction point, connection & testing of UPS including replacement of U/S part of 05 KVA complete all as specified and directed. Note :- (a) Minor item / spares parts shall deemed to be included in the unit quoted rate & not to be paid separtely .
5
-
-
S&F in renewal of single pole and neutral sheet metal enclosure with a two pin and earth plug and socket and including one MCB SPN 20 Amp, 240 Volt, MCB, 'C' curve type with AC box, rupturing capacity 10 KA complete all as specified and directed.
10
-
-
S&F in renewal of MCB single pole 6 to 32 Amp, 'C' curve having rupturing capacity 10 KA conforming to IS-8828-1996, IEC-60898, complete all as specified & directed.
10
-
-
S&F in renewal of metal clad plug 2P+E for all type of AC's as per existing Make and size complete all as specified & directed.
10
-
-
S&F in renewal of metal clad socket 2P+E for all type of AC's as per existing Make and size complete all as specified & directed.
10
-
-