Military Engineer Services Tender
View complete overview of MES Tender
Costs
EMD
₹ 86,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_688798_1Bid Award Id
ViewTender No
134 WE-86(T)/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F in replacement cable jointing kit for 11KV grade cable for Outdoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed.
4
-
-
... More
S&F in replacement cable jointing kit for 11KV grade cable for Indoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed.
8
-
-
... More
S&F in replacement cable jointing kit for 11KV grade cable for Indoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed.
2
-
-
... More
S&F in replacement cable jointing kit for 11KV grade cable for straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed.
7
-
-
... More
S&F in replacement cable jointing kit for 11KV grade cable for straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed.
2
-
-
... More
Supply, laying, testing and commissioning XLPE HT cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor, 11000 Volts grade (earthed) of size 3 Core 95 Sqmm, laid in trenches / floor / duct / fixed on poles through GI tubing in different locations/ areas, complete all as specified and directed.
496
-
-
... More
Supply, laying, testing and commissioning XLPE HT cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor, 11000 Volts grade (earthed) of size 3 Core 120 Sqmm, laid in trenches / floor / duct / fixed on poles through GI tubing in different locations/ areas, complete all as specified and directed.
460
-
-
... More
S&F in repairs including testing of swing out explusion fuse isolated assembly with fuse carrier outdoor type 11 KV supply 50 Amp (DO fuse) including mounting bracket & post insulator, complete all as specified and directed.
3
-
-
... More
S&F in repairs transmission class type drop out fuse, 11000 Volts rating 25-50 Amps, outdoor type, complete all as specified and directed.
3
-
-
... More
S&F in repairs lightening arrestor, expulsion type complete with all fittings, transmission class, discharge capacity of 65 Kilo Amps, suitable for 11 KV, complete all as specified and directed.
2
-
-
... More
Repairing / Servicing the air break isolating switch of HT 11 KV 100/200 Amps by replacing the defective major spares including provn of minor parts, bolts, nuts etc, complete all as specified and directed. NOTES :- Major spare parts shall be measured and paid seperately under relevant items of BOQ.
2
-
-
... More
S&F in repairs following 11KV Air Break Switch spares, complete all as specified and directed :-
-
-
-
... More
Male contact/ moving contact blade.
6
-
-
... More
Female contact / fix contact jaw.
6
-
-
... More
MS jumper carrier.
6
-
-
... More
Back connector plate.
6
-
-
... More
Repairing / Servicing the air break isolating switch of HT 33 KV 100/200 Amps by replacing the defective major spares including provn of minor parts, bolts, nuts etc, complete all as specified and directed. NOTES :- Major spare parts shall be measured and paid seperately under relevant items of BOQ.
1
-
-
... More
S&F in repairs following 33KV Air Break Switch spares, complete all as specified and directed :-
-
-
-
... More
Male contact/ moving contact blade.
3
-
-
... More
Female contact / fix contact jaw.
3
-
-
... More
Rotating contactor pipe 400 A
1
-
-
... More
MS jumper carrier.
3
-
-
... More
Back connector plate.
3
-
-
... More
S&F in repairs drop out (DO) fuse unit expulsion type, outdoor, three pole, 200 Amp suitable for HT 33 KV, comprising of insulators, steel base mounting frame, GI nut bolts etc with 30A, HT barrel type fuse, complete all as specified and directed.
1
-
-
... More
S&F in repairs including testing and commissioning of (GOD) gang operated type air break isolating switch, horizontal / vertical type mounting complete, double break and operation rod of suitable length 400 Amps capacity and suitable for 33 KV HT supply, complete all as specified and directed.
1
-
-
... More
S&F in repairs lightening arrestor, zinc oxide gap less type, station class suitable for 33 KV /10 KA, complete with all fittings, complete all as specified and directed.
3
-
-
... More
S&F in repairs single post insulator, 33 KV with mounting spindle etc, complete all as specified and directed.
2
-
-
... More
S&F in repairs pin insulator, 33 KV with mounting spindle etc, complete all as specified and directed.
2
-
-
... More
S&F in repairs disc insulator, 33 KV with hardware fittings etc, complete all as specified and directed.
9
-
-
... More
M&L for preparation of old painted external surfaces of HT, 2 pole structure consisting of HT 11 mtr steel pole, cross arms, GOD assy with pipe, DO fuse assy, clamps etc, of any description and applying one coat of aluminium paint manually, complete all as specified and directed.
NOTES :- (a) The rates inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item
(b) The painting work will be carried out during Holidays only to avoid electric shut down.
12
-
-
... More
M&L for preparation of old painted external surfaces of HT, 4 pole structure consisting of HT 11 mtr steel pole, cross arms, GOD assy with pipe, DO fuse assy, clamps etc, of any description and applying one coat of aluminium paint manually, complete all as specified and directed.
NOTES :- (a) The rates inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item
(b) The painting work will be carried out during Holidays only to avoid electric shut down.
8
-
-
... More
M&L for preparation of old painted surfaces of HT 33/11 KV MRS at Old Air Field, consisting of steel poles / ISMBs, cross arms, GOD pipe, clamps etc. having of any description and applying one coat of aluminium paint manually, complete all as specified and directed.
NOTES :- (a) The rates inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item. (b) The painting work will be carried out during Holidays only to avoid electric shut down.
2
-
-
... More
S&F in repairs including testing of metering & protection current transformer oil filled, outdoor type of 33 KV capacity ratio 100-50/5 or 200-100/5 class=5P, 10/1 15 VA including dismantling old existing CT, complete all as specified and directed.
2
-
-
... More
S&F in repairs cable end box heat shrinkable type, outdoor type, suitable for XLPE cable 3 core 300 Sqmm, 33 KV HT supply, complete all as specified and directed.
2
-
-
... More
Dismantling old and burnt out PT unit, 11000/1100 volts draw out type epoxy resin cast type, taking out contact with lead and bushing from the bus bar and PT, replacing by new one of same model, suitable for 11 KV VCB including testing on completion, complete all as specified and directed.
1
-
-
... More
M&L for cutting and trimming of tree branches of girth 25mm to 75mm to 3mtr all around of any size, which is obstructing illumination of street light and touching LT/ HT over head line, by using required tools and plants including removing trimmed tree branches, complete all as specified and directed.
NOTE :- Each cutting and trimming will be measured and paid separately.
615
-
-
... More
S&F in replacement of synthetic insulating rubber mat, ISI Marked of size 1 mtr x 2 mtr x 19mm, suitable for 11/33 KV as per IS-15652-2006 (Superseeding IS-5424) suitable for electric sock safety at 33 KV MRS at Old Air Field, complete all as specified and directed.
18
-
-
... More
M&L for replacement of temperature gauge suitable size for power transformer / AVR of any capacity, complete all as specified and directed.
4
-
-
... More
S&F in repairs bolted type LM 6 alloy aluminium rigid stud type terminal connector of type universal connector suitable for 33/11 KV type ACSR conductor / busbar, complete all as specified and directed.
1
-
-
... More
S&F in repairs bolted type LM 6 alloy aluminium rigid pad type terminal connector for pad to conductor suitable for 33/11 KV type ACSR conductor, complete all as specified and directed.
1
-
-
... More
S&F in repairs bolted type LM 6 alloy aluminium rigid parallel connector conductor to conductor suitable for 33/11 KV type ACSR conductor, complete all as specified and directed.
1
-
-
... More
Taking out the existing HT AVR unit 11000 volts grade (Make : Adrew Yule) carefully by dismantling all incoming & outgoing electrical/ mechanical connections lifting and transport to reputed work shop by means of using suitable tools & plants,opening the body of buckbooster/ AVR units find out the defects and servicing, repair/ removing including replacing the defective spare parts and re-assembling, complete all as specified and directed (De-hydration of oil/ new winding willbe measured and paid under relevant item of this BOQ). The job involves the following :-
(a) Dismantling & taking down carefully from plant room by disconnecting all electrical/ mechanical connection from HT and LT side including transporting to work shop.
(b) Opening the body of the AVR/ buck booster units complete, drain out the oil, lift the cover and coil assemble, checking the serviceability state of spares such as moving carbon roller, windings, insulating oil, LT/ HT elect connections, HT/ LT bushings, HT/ LT brass terminals, tig & tag connectors, chain rack, limit switch, bearings, couplings, motor, micor porcessor based PCB card, CT/PT assembly, Aux/ reversible contactors, winding/ oil temp/ buchloz relays assembly, earthing connections, copper strip etc. and repair/ replace the same existing model/ make and making fully serviceable state of AVR/ buck booster assembly at site including testing as per OEM specifications, complete all as specified and directed.
(c) Cleaning the core laminations assembly by oil complete, removing the carbon sediments. dust in the coil and core gently without making any damage to coil and core.
(d) Re-assembling all dismantled parts including provision of new gasket, nut, bolts, refilling with transformer oil and transporting back to original location including electric/ mechanical connection testing and commissioning, complete all as specified and directed.
1
-
-
... More
S&F in repairs moving carbon rollers of existing size and make, suitable for 2000 KVA AVR unit, complete all as specified and directed.
24
-
-
... More
S&F in repairs Tie & Tac brass connectors, suitable for 2000 KVA AVR unit, complete all as specified and directed.
24
-
-
... More
S&F in repairs chain rack (double) including bearing, suitable for 2000 KVA AVR unit, complete all as specified and directed.
2
-
-
... More
S&F in repairs limit switch, suitable for 2000 KVA AVR unit, complete all as specified and directed.
2
-
-
... More
S&F in repairs SS coupling, suitable for 2000 KVA AVR unit, complete all as specified and directed.
1
-
-
... More
S&F in repairs chain assembly, suitable for 2000 KVA AVR unit, complete all as specified and directed.
1
-
-
... More
S&F in repairs synchronous motor, suitable for 2000 KVA AVR unit, complete all as specified and directed.
1
-
-
... More
S&F in repairs PCB card, suitable for 2000 KVA AVR unit, complete all as specified and directed.
1
-
-
... More
S&F in repairs PT unit 11000/ 1100 Volts, suitable for 2000 KVA AVR buck booster unit, complete all as specified and directed.
1
-
-
... More
S&F in repairs reversible contactor 3 pole 800 Amps, suitable for 2000 KVA AVR unit, complete all as specified and directed.
1
-
-
... More
S&F in repairs winding temperature relay complete, suitable for 2000 KVA AVR unit, complete all as specified and directed.
1
-
-
... More
S&F in repairs oil temperature relay complete, suitable for 2000 KVA AVR unit, complete all as specified and directed.
1
-
-
... More
S&F in repairs buchloz relay assembly complete, suitable for 2000 KVA AVR unit, complete all as specified and directed.
1
-
-
... More
S&F in repairs copper strip of any size, suitable for 2000 KVA AVR unit, complete all as specified and directed.
8
-
-
... More
S&F in repairs connector strip 16/ 24 way, suitable for 2000 KVA AVR unit, complete all as specified and directed.
1
-
-
... More
S&F in repairs aux contactor, suitable for 2000 KVA AVR unit, complete all as specified and directed.
2
-
-
... More
Taking down carefully the existing 11KV/433 V distribution transformer of capacity 100 KVA to 600 KVA by disconnecting HT overhead connection / underground cables and earth strips etc, from any substation / locations using suitable capacity of crane or by any other mechanical method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer, transportation to site and unloading including placing at given/ existing position and re-commissioning complete all as specified and directed.
NOTE :- All required T&P for disonnection, connection, loading and loading including necessary petty items such as bolts, nuts etc will be arranged by the contractor and rates for the same shall be deemed to be included in the rates quoted.
10
-
-
... More
M&L for repairs toTransformer step down 11KV/0.433 KV of any type of capacity 100 KVA to 250 KVA, after dismantling the transformer body carefully, opening the top cover of transformer for inspection / repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/ sludge deposited in transformer housing core, renewal/ replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nuts and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, Painting of complete transformer body from outside and inside by weather proof type using spray gun, Marking of MES/SM Number etc, replacement of conservator tank glass, re-intalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed. NOTE :- Winding wire including labour for making of coils and LT/HT bushes will be measured & paid seperately.
6
-
-
... More
All as per Srl item No 54.00 above, but of capacity 11 KV/0.433 KV, 315 KVA to 600 KVA, complete all as specified and directed.
4
-
-
... More
Supply and filling of fresh transformer oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation / leakage / losses due to dehydration in HT 33 KV transformerv / HT 11 KV AVTR / Distribution transformer 100 to 600 KVA or for replacement complete including removing of old unservicable transformer oil, complete all as specified and directed. NOTE :- Proper document should be maintained by the contractor and submit to Engr-in-Charge.
2600
-
-
... More
M&L for conducting oil filtration by stream line / vacuum type filter machine to remove the moisture / carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer incl routine testing after filtration for any capacity of transformers/ AVR/CT/ PT units, complete all as directed. NOTES :- (a) The contractor shall change the filter assy before starting the filtration of power / distribution transformer of capacity 600 KVA and more capacities in presence of Engr-in-Charge.
(b) Proper document should be maintained by the contractor and submit to Engr-in-Charge.
9600
-
-
... More
S&F in replacement brass terminal rod with nuts, bolts washers & bushings, suitable for HT side of the transformer of any make and capacity from 100 KVA to 300 KVA, complete all as specified and directed.
10
-
-
... More
All as per Srl item No 58.00 above but LT side, complete all as specified and directed.
10
-
-
... More
M&L for replacement of brass terminal rod with nuts, bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 315 KVA to 600 KVA, complete all as specified and directed.
8
-
-
... More
All as per Srl item No 60.00 above but LT side, complete all as specified and directed.
8
-
-
... More
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100 KVA to 300 KVA transformer, complete all as specified and directed.
12
-
-
... More
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA to 600 KVA transformer, complete all as specified and directed.
14
-
-
... More
M&L for painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc, paint free after painting including writing the MES/SM Number with white enamelled paint, complete all as directed for capacity of transformer 63 KVA to 300 KVA (Indoor/outdoor type), complete all as specified and directed.
5
-
-
... More
All as per Srl item No 64.00 above, but for capacity of transformer 300 KVA to 600 KVA (Indoor/outdoor type), complete all as specified and directed.
4
-
-
... More
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 63 KVA to 600 KVA transformer and 1000 KVA to 2000 KVA transformer/ AVR units, complete all as specified and directed.
26
-
-
... More
M&L for earthing complete with GI earth plate electrode of size 60cmx60cmx6mm thick electrode, burried directly in ground, (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to GI strip of size 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 05 and including earth work, PCC pit and RCC cover, watering pipe 20mm light grade, funnel, wire mesh, charcoal dust, 40mm dia light grade protection pipe and salt etc, and connected to earthing test point including dismantling of old unserviceable earthing and taking out material, complete all as specified and directed.
14
-
-
... More
M&L for replacement off load tap changer for distribution transformer of any make and capacity from 200-600 KVA, complete all as specified and directed.
4
-
-
... More
M&L for super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding the HT transformer / HT AVR of any capacity and any make, complete all as specified and directed.
697
-
-
... More
M&L for replacement of bush type insulator white / brown / green, working pressure 433 Volts LT side, complete all as specified and directed.
36
-
-
... More
M&L for servicing and repairing of OLTC (ON load Tap changer) for 11 KV Transformer by disconnecting and dismantling all burnt out cables / fuses/ relays / contactors, toggle switch/knobs / indicators / reading units and other accessories repairs / replace the unserviceable items and making the OLTC serviceable condition and connecting back to its original position, complete all as specified and directed.
2
-
-
... More
M&L for servicing of 33 KV VCB / 11 KV VCB / bus coupler by dismantling, cleaning, greasing the complete VCB with attached relays bus bar etc. insulation testing, setting the contact gap by measuring as required re-assembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning, complete all as specified and directed.
NOTE :- New spare parts shall be measured and paid separately under respective items of this BOQ.
8
-
-
... More
M&L for carrying out primary & secondary injection test of 33 KV or 11 KV indoor / outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning including submitting the test report, complete all as specified and directed.
NOTE :- PIT / SIT for VCB will be carried out in 6 months intervals and each primary & secondary injection test will be measured and paid and considered as one unit.
6
-
-
... More
Supply and fixing in repairs the following spares for outdoor VCB 33 KV, 800 A, 750 MVA fault level 36 V-26/2000 & VCB 11 KV 400 Amps 25 KA 250 MVA as approved by GE, complete all as specified and directed :-
-
-
-
... More
Closing coil 24/30V DC .
2
-
-
... More
Tripping coil 24/30V DC.
2
-
-
... More
Antipumping device 24/30V DC.
3
-
-
... More
33 KV porcelain bushing for VCB Top.
3
-
-
... More
33 KV porcelain bushing for VCB bottom.
3
-
-
... More
Connector strip 16 Way.
4
-
-
... More
Earth Fault and over current relay of L & T Model No MC61A 24-110V.
3
-
-
... More
Digital type power factor indicator meter.
4
-
-
... More
Digital type Voltmeter / Ammeter 96mm x 96mm size.
4
-
-
... More
LED type indicator lamp assembly.
5
-
-
... More
Vaccum interrupter for indoor VCB.
2
-
-
... More
Spout incoming side.
3
-
-
... More
Spout outgoing side.
4
-
-
... More
Epoxy insulators bushings for incoming / outgoing cables / bus bar suppors as per existng size of VCBs.
11
-
-
... More
Insulated copper bus bar of existing size and thickness for VCBs.
2
-
-
... More
Gear system assembly complete with handle for charging / discharging of VCBs.
2
-
-
... More
Spring charging motor for VCBs.
1
-
-
... More
Supply only tinned copper fuse wire SWG No 001, 11 KV grade having fire resistant copper wire mixed with silver coated fuse wire of capacity 2.5 to 5 Amps in 250 mtrs roll all as specified and directed.
20
-
-
... More
Supply only tinned copper fuse wire SWG No 001, 11 KV grade having fire resistant copper wire mixed with silver coated fuse wire of capacity 5 to 10 Amps in 250 mtrs roll all as specified and directed.
30
-
-
... More
Supply only tinned copper fuse wire SWG No 001, 11 KV grade having fire resistant copper wire mixed with silver coated fuse wire of capacity 20 to 25 Amps in 250 mtrs roll all as specified and directed.
40
-
-
... More
Supply only tinned copper fuse wire SWG No 001, 11 KV grade having fire resistant copper wire mixed with silver coated fuse wire of capacity 50 to 60 Amps in 250 mtrs roll all as specified and directed.
10
-
-
... More
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of cables, erection of poles, stays etc. and getting out in hard/ dense soil, complete all as specified and directed.
258.1
-
-
... More
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
171.5
-
-
... More
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
86.6
-
-
... More
Supply and laying dry river sand, laid in trenches for cable protection, as 8cm thick below the cable and 15cm thick above the cable, complete all as specified and directed.
NOTE :- Punned thickness of sand shall be measured and paid.
69.7
-
-
... More
M&L for sub class 'B' brick, old size, as in covering protection to the eletric cable, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to length of brick, complete all as specified and directed.
7.5
-
-
... More
S&F in repairs trenches on wall of 80mm bore GI tubing, medium grade, laid in trenches, road crossing, cable protection or fixed to walls with MS clamps, complete all as specified and directed.
12
-
-
... More
All as per Srl item No 84.00 above, but 100mm bore pipe.
12
-
-
... More
M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) for pole and stay foundation, complete all as specified and directed.
2
-
-
... More
M&L for PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for pole and stay foundation, complete all as specified and directed.
2
-
-
... More
M&L for 40mm graded coarse aggregate (broken stone or boulders), laying in sub - station yard, complete all as specified and directed.
22
-
-
... More
M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in coping including necessary form work, complete all as specified and directed.
4
-
-
... More
NOTE :-
An amount of Rs. 3,90,033.75 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.
-
-
-
Evaluation Notes How It Works ?