Military Engineer Services Tender

View complete overview of MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
NA
Opening Date8 Apr 2022
Closing Date6 May 2022
Tender Amount₹ 39,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified

251

-

-

... More
M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I all as specified. Note : punned thickness shall be measured for payment purpose

157

-

-

... More
Supply and lay brick of conventional size 230x110x75mm locallly available as protection of cable in trenches complete all as specifed and as directed.

16.8

-

-

... More
M&L PCC 1:4:8 type B2 (using 40 mm graded stone aggregate) as in foundation of pole & stay complete all as specified and directed.

0.8

-

-

... More
M&L PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in filling of pole & stay complete all as specified and directed.

8.1

-

-

... More
M&L PCC 1:2:4 type B2 (using 20 mm graded stone aggregate) as in coping of pole complete all as specified and directed.

1.7

-

-

... More
Supply and fix in repair ACSR conductor including stringing on LT poles complete incl aluminium binding wires, jumpering, bindings at insulators etc complete all as specified and directed.

2.5

-

-

... More
Cross arm, bracings, supports , clamps and back plate fabricated from structural steel section, including nut , bolts , washers, welding , bendings cold or hot, drilling hole for both in any shape or size as indicated or directed and inclusive of one prime coat of red oxide primer, one under coat and one finishing coat of synthetic enamel paint including taking down the old unserviceable cross arms complete all as specified and directed.

2.5

-

-

... More
Taking out old unserviceable steel tubular/RCC poles 9 mtr long and supply and erection of steel tublar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle all as specified and directed by Engr-in-Charge.

10

-

-

... More
Disconnecting the windings of loose overhead conductors of LT lines from insulators and restringing the same for proper sag and rewinding including aluminium winding wires, tapes etc and jumpering for any type of conductor complete of single run conductor complete all as specified and directed. Note: Quoted rate shall deemed inclusive of triming of tree branches around the poles upto 3 mtr and nothing extra shall be admissible on this account.

4000

-

-

... More
S&F in repair insulator pin type porcelain vitereous , white brown or green insulator including one galvanised mild steel spindle, two galvinised washer and one GI nut 100 mm height and 65 mm dia for 1100 Volt grade complete all as specified and directed.

30

-

-

... More
S&F in repair insulator shackle type, porcelain, vitereous, white brown or green insulator including one galvanised mild steel straps, washers, insulator bolts, washer and nuts for working pressure 1100 Volts height 100mm, dia 115mm, section of strap (31x5) mm dia of bolt 14 mm complete all as specified and directed.

30

-

-

... More
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls including taking down old unservicable cables, complete all as specified and directed for following sizes of cable :- Note:- Excavation, Earthwork, sand cushioning and brick protection shall be measured and paid for separately.

-

-

-

... More
10 Sqmm 2 Core.

350

-

-

... More
16 Sqmm 2 Core.

300

-

-

... More
16 Sqmm 4 Core.

300

-

-

... More
25 Sqmm 3.5 Core.

250

-

-

... More
35 Sqmm 3.5 Core.

300

-

-

... More
50 Sqmm 3.5 Core.

250

-

-

... More
70 Sqmm 3.5 Core.

300

-

-

... More
95 Sqmm 3.5 Core.

200

-

-

... More
120 Sqmm 3.5 Core.

200

-

-

... More
150 Sqmm 3.5 Core.

200

-

-

... More
S&F in repair moulded case circuit breaker four pole 400 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay complete all as specified and directed.

6

-

-

... More
S&F in repair moulded case circuit breaker four pole 350 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay complete all as specified and directed.

4

-

-

... More
S&F in repair moulded case circuit breaker four pole 250 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay complete all as specified and directed.

4

-

-

... More
S&F in repair moulded case circuit breaker four pole 200 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay complete all as specified and directed.

3

-

-

... More
S&F in repair moulded case circuit breaker four pole 160 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay complete all as specified and directed.

3

-

-

... More
S&F moulded case circuit breaker four pole 125 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay complete all as specified and directed.

3

-

-

... More
S&F in repair moulded case circuit breaker four pole 100 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay complete all as specified and directed.

4

-

-

... More
S&F in repair moulded case circuit breaker four pole 63 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay complete all as specified and directed.

4

-

-

... More
S&F in repair digital voltmeter 0 to 500 Volts 96mm x96mm flush type in LT Panels complete all as specified and directed.

2

-

-

... More
S&F in repair digital ammeter range as per existing 96mm x96mm flush type in LT panels complete all as specified and directed.

2

-

-

... More
S&F in repair LT current transformer ratio from 200/5 Amps or 100/5 or 400/5 in LT panels complete all as specified and directed.

2

-

-

... More
S&F in repair selector switch of voltmeter/ammeter in LT panel boards complete all as specified and directed.

2

-

-

... More
S&F in repair indicator assembly (RYB) LED type in LT panel boards complete all as specified and directed.

2

-

-

... More
S&F tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 40 mm bore including removing the rusted old one complete all as specified and directed.

20

-

-

... More
S&F tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 50 mm bore including removing the rusted old one complete all as specified and directed.

20

-

-

... More
Supply and Fix in repair of 1100 Volts grade heavy duty cable PVC insulated aluminium conductor as service connections served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm dia GI suspension wire one twin core cable flat or circular stranded conductor of size 10 sqmm 2 core complete all as specified and directed.

600

-

-

... More
Supply and Fix in repair of 1100 Volts grade heavy duty cable PVC insulated aluminium conductor as service connections served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm dia GI suspension wire one twin core cable flat or circular stranded conductor of size 16 sqmm 2 core complete all as specified and directed.

600

-

-

... More
M&L in Fix in repair of Earthing complete with GI earth plate 60cmx60cm and 6mm thick electrode and 4mm dia GI wire as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and including earth work, PCC pit and RCC cover, watering pipe 20 mm dia light grade,funnel, wire mesh, protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire, charcoal dust and salt etc. and connected to earthing test point complete all as specified and directed.

10

-

-

... More
S&F in Fix in repair of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 35W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and directed.

45

-

-

... More
S&F in Fix in repair of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 90W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and directed.

40

-

-

... More
S&F in Fix in repair of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 60W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and directed.

40

-

-

... More
S&F in Fix in repair of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 70W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and directed.

45

-

-

... More
Supply and fixing in repair of LED based energy saving & environment friendly long life versatile luminaire made in pressure die cast housing and heat sink with aluminium extruded with IP-65 of 30 watt complete with front toughened glass cover including connection with 2.5 sqmm 3 core PVC insulated copper wire complete all as specified and directed.

12

-

-

... More
Supply and fixing in repair of LED based, saving & environment friendly, long life versatile flood light Lumos IP-65 of 100 W capacity complete with front glass cover complete all as specified and directed.

20

-

-

... More
Supply and fixing in repair of LED based, saving & environment friendly, long life versatile flood light Lumos IP-65 of 120 W capacity complete with front glass cover complete all as specified and directed.

20

-

-

... More
S&F in replacement of LED driver suitable for 35W to 60W complete all as specified and directed.

30

-

-

... More
S&F in replacement of LED driver suitable for 70W complete all as specified and directed.

30

-

-

... More
S&F in replacement of LED driver suitable for 90W to 120 W complete all as specified and directed.

30

-

-

... More
Cutting out the burnt cable end and reconnecting with providing new lugs, tapes etc for cable size 25 sqmm 3.5 core to 50 sqmm 3.5 core complete all as specified and directed.

18

-

-

... More
Cutting out the burnt cable end and reconnecting with providing new lugs, tapes etc for cable size 70 sqmm 3.5 core to 120 sqmm 3.5 core complete all as specified and directed.

20

-

-

... More
M&L in repair of panel control wiring in LT Panels and Feeder Pillar Boxes using solid copper conductor single core PVC insulated 2.5 sqmm cable for voltmeter, ammeter, starters, indicators and selector switches etc complete all as specified and directed.

3

-

-

... More
S&F in Fix in repair PVC Line spacer of superior quality of 4 Way spiral type all as specified and as directed.

80

-

-

... More
S&F in Fix in repair PVC Line spacer of superior quality of 6 Way spiral type all as specified and as directed.

80

-

-

... More
Taking out old existing unservicable Panel and supply installation, commissioning of CPRI approved LT panel board, outdoor, cubical, dust and vermin proof made out of 3.15 mm thick MS sheet and steel section with back door detachable type fitted with nuts, bolts and washers and frint doors openable type fitted with knobs and hinges CRCA sheet IP-43 grade protcetion and having locking arrangement including individual chamber for MCB and MCCBs having sufficient space for working. LT Panel shall be prewired with suitable size OVC insulated copper conductor cable. The panel shall be powder coated and shall be mounted on angle iron frame made out of MS angle of size 50mmx50mmx6mm of height 30cm from floor level. The panel shall be be comprising and including supply and fixing of following items :- Loc:- Tattoo Grd

1

-

-

... More
(a) MCCB 400 Amps 36 KA, 415volts four pole with adjustable thermal setting - 01 No (Incomer)

-

-

-

... More
(b) MCCB 100 Amps 36 KA, 415volts four pole with adjustable thermal setting - 02 Nos

-

-

-

... More
(c) MCCB 200 Amps 36 KA, 415volts four pole with adjustable thermal setting - 01 Nos

-

-

-

... More
(d) Digital Voltmeter 0-500 Amp range 96x96 Sqmm size with four way selector switch - 01 No

-

-

-

... More
(e) Digital Ameter with CTs 0-500 Amp range 96x96 Sqmm size with four way selector switch - 01 No

-

-

-

... More
(f) LED Indication Lamp - 03Nos

-

-

-

... More
(g) Aluminium strip bus bar sleeve insulated 600 amps capacity four pole mounted on epoxy insulators - 01 No

-

-

-

... More
(h) cable entry with double comprissioning glands and two with provision of two Nos earthing terminals.

-

-

-

... More
(j) Internal wiring of panel board with single core copper cable PVC insulated of suitable size and control fuses.

-

-

-

... More
(k) Necessary grouting with PCC 1:3:6 and fixing arrangements as reqd incl mounting nut, bolt and washers complete

-

-

-

... More
Taking out old existing unservicable Panel and supply installation, commissioning of CPRI approved LT panel board, indoor, cubical, dust and vermin proof made out of 2mm thick MS sheet and steel section with back door detachable type fitted with nuts, bolts and washers and frint doors openable type fitted with knobs and hinges CRCA sheet IP-43 grade protcetion and having locking arrangement including individual chamber for MCB and MCCBs having sufficient space for working. LT Panel shall be prewired with suitable size OVC insulated cipper conductor cable. The panel shall be powder coated and shall bemounted on angle iron frame made out of MS angle of size 50x50x6mm of height 30cm from floor level. The panel shall be be comprising and including supply and fixing of following items :-

1

-

-

... More
(a) MCCB 125 Amps 25 KA, 415volts four pole with adjustable thermal setting - 01 No (Incomer)

-

-

-

... More
(b) MCCB 63 Amps 16 KA, 415volts four pole with adjustable thermal setting - 02 Nos

-

-

-

... More
(c) Digital Voltmeter 0-500 Amp range 96x96 Sqmm size with four way selector switch - 01 No

-

-

-

... More
(d) Digital Ameter with CTs 0-200 Amp range 96x96 Sqmm size with four way selector switch - 01 No

-

-

-

... More
(e) LED Indication Lamp - 03Nos

-

-

-

... More
(f) Aluminium strip bus bar sleeve insulated 300 amps capacity four pole mounted on epoxy insulators - 01 No

-

-

-

... More
(g) cable entry with double comprissioning glands and two with provision of two Nos earthing terminals.

-

-

-

... More
(h) Internal wiring of panel board with single core copper cable PVC insulated of suitable size and control fuses.

-

-

-

... More
(j) ON Load Changeover switch of 4 pole, 415 volt, 200 Amps capacity - 01 No

-

-

-

... More
(k) Necessary grouting with PCC 1:3:6 and fixing arrangements as reqd incl mounting nut, bolt and washers complete

-

-

-

... More
M&L painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia complete all as specified and directed.

60

-

-

... More
Supply and Fix in repair Off load change over switch in sheet metal enclosure of capacity 63 Amps, four pole, 415V, 50 Hz complete all as specified and directed.

3

-

-

... More
Supply and Fix in repair on load change over switch in sheet metal enclosure of capacity 100 Amps, four pole, 415V, 50 Hz complete all as specified and directed.

3

-

-

... More
Supply and Fix in repair Off load change over switch in sheet metal enclosure of capacity 200 Amps, four pole, 415V, 50 Hz complete all as specified and directed.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.