Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date29 Nov 2024
Closing Soon27 Dec 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
110 KVA to 125 KVA 3 phase 50 HZ

3

-

-

... More
NOTE for item No-1.01 to 1.03 :- (i) The quoted rates of the contractor shall include for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under respective items of Sch `A’ as `Supply only. Quoted rates shall be inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil all as directed by the Engineer-in-Charge. (iii) Fresh engine oil replaced for DG sets shall be supplied by the contractor as “ Supply only” and shall be measured and paid separately under respective item of Sch ‘A’ . However, cost of filling is deemed to be included under the rates quoted by the contractor for above item.

-

-

-

... More
Supply only following spare parts of DG set of 15 KVA capacity as per the existing make of DG Set :-

-

-

-

... More
Fuel filter element ( Set of Two) Make : Kirloskar

2

-

-

... More
Oil Filter element (Set of Two) Make : Kirloskar

2

-

-

... More
Air Filter ( Set of Two) Make : Mico

2

-

-

... More
By pass filter Make : Mico

2

-

-

... More
Fan belt set ( Set of Two) Make:-Faral

2

-

-

... More
Radiator hose pipe of suitable size

2

-

-

... More
Supply only following parts of DG set of 25 to 30 KVA capacity as per the existing make of DG Set :-

-

-

-

... More
Fuel filter element ( Set of Two) Make : Kirloskar

6

-

-

... More
Oil Filter element (Set of Two) Make : Kirloskar

6

-

-

... More
Air Filter ( Set of Two) Make : Mico

6

-

-

... More
By pass filter Make : Mico

6

-

-

... More
Fan belt set ( Set of Two) Make:-Faral

10

-

-

... More
Radiator hose pipe of suitable size

6

-

-

... More
Supply only following parts of DG set of 110 KVA to 125 KVA capacity as per the existing make of DG Set :-

-

-

-

... More
Fuel filter element ( Set of Two) Make : Mico

3

-

-

... More
Oil Filter element (Set of Two) Make : Greaves

3

-

-

... More
Air Filter ( Set of Two) Make : Mico

3

-

-

... More
By pass filter Make : Mico

3

-

-

... More
Fan belt set ( Set of Two) Make:-Faral

3

-

-

... More
Radiator hose pipe of suitable size

3

-

-

... More
M&L in replacement for coolent for DG set as existing DG set manufacturers recommendation complete all as specified.

200

-

-

... More
Supply only engine oil of DG set of grade 20 W 40. Make :- Servo, Veedol & elf

210

-

-

... More
Supply only following items for battery 60 to 180 AH 12 Volts :-

-

-

-

... More
Heavy duty brass bettery terminal

30

-

-

... More
Battery cable 70 Sq mm multy stranded copper conductor

60

-

-

... More
M&L for overhauling of silencer assy after removing from DG set of any capacity, decarbonizes of silencer and extention pipe, cleaning repair to holes by gas welding, denting and reassembling the same to the Gen set incl covering with & including asbestos rope of suitable diameter complete all as specified and directed.

8

-

-

... More
Taking down radiator assembly of DG set of any capacity from engine mounting by opening water hose and nut bolt cleaning of radiator inside and out side with anti rust solution, checking the radiator by filling water and repairing for any leakage by brazing the radiator and ensure for no leakage Re- fixing the radiator at place including water hoses and refixing to exiting position all as directed.

10

-

-

... More
Taking down turbo charger from engine of DG set of any capacity for servicing and replacement of turbo kit complete all as specified and directed .

6

-

-

... More
Taking down unserviceable alternator from engine of DG set of any capacity for servicing and replacement of carbon brushes, PCB and refixing after servicing of unserviceable parts and testing complete all as specified and directed.

8

-

-

... More
Taking down unserviceable self starter 24 Volts for servicing and replacement of old carbon brushes, benteak, bearing and contact blades etc and refixing after servicing and replacement of unsv parts, complete all as specified and directed. (NOTE : Bearing of alternator will be measured and paid separately)

2

-

-

... More
Taking down unserviceable self starter 12 Volts for servicing and replacement of old carbon brushes, benteak, bearing and contact blades etc and re fixing after servicing and replacement of unsv parts (NOTE : Bearing of alternator will be measured and paid separately)

4

-

-

... More
Supply only self starter bearing suitable for 12/24 volts starter as per sample. Make :- NBC / SKF

10

-

-

... More
Dismantling the fuel injection pump from engine block of DG set of 15 KVA to 30 KVA capacity, disconnecting all fuel inlet and outlet lines, disconnecting the drive for carrying out repairs/ replacements including calibration, Re assambling of FIP and fixing back in position after repair / replacement of unserviceable parts complete all as directed. Note :- Calibration of FIP complete shall be got done from manufacturer authorized dealer / workshop to entire satisfaction of Engineer- in- Charge.

6

-

-

... More
Supply only following unsv spare parts of fuel injection pump of DG set of 15 KVA to 30 KVA to suit the requirement of the item and as approved :-

-

-

-

... More
Nozzle plunger Make : BOSCH or equivalent

6

-

-

... More
Delivery valves Make : BOSCH or equivalent

5

-

-

... More
Injecter holder with washers Make : Kirloskar or equivalent

6

-

-

... More
Injecter Make : BOSCH or equivalent

8

-

-

... More
FIP packing Kit Make : Kirloskar or equivalent

6

-

-

... More
Bearing number 30203 or suitable matching number Make : NBC/SKF

6

-

-

... More
Bearing number 6203 or suitable matching number Make : NBC/SKF

6

-

-

... More
Tappet bolt

12

-

-

... More
Roller pin Make : BOSCH or equivalent

12

-

-

... More
Cotton sleeves Make : Kirloskar or equivalent

10

-

-

... More
Sleeve holder Make : Kirloskar or equivalent

10

-

-

... More
Dismantaling the fuel injection pump from engine block DG set of 110 KVA to 125 KVA capacity, disconnecting all fuel inlet and outlet lines, disconnecting the drive Make MICO for carrying out repairs/replacements including calibration as under, Reassy of FIP & fixing back in position after repairs/replacements of unsv parts complete all as directed. Note- Calibration of FIP shall be done from MICO auth wksp/dealer to the entire satisfaction of Engineer-in-Charge

3

-

-

... More
Supply only following unsv spare parts of fuel injection pump of DG set of 110 KVA to 125 KVA capacity to suit the requirement of the item and as approved :-

-

-

-

... More
Nozzle Plunger Make : Kirloskar or equivalent

4

-

-

... More
Delivery valves Make : BOSCH or equivalent

4

-

-

... More
Injecter holder with washers Make : BOSCH or equivalent

4

-

-

... More
Injecter

4

-

-

... More
FIP Packing kit Make : Kirloskar or equivalent

3

-

-

... More
Bearing No 30203 Make : NBC/SKF

3

-

-

... More
Bearing No 6203 Make : Kirloskar or equivalent

3

-

-

... More
Tappet bolt Make : NBC/SKF

6

-

-

... More
Roller pin Make : Kirloskar or equivalent

6

-

-

... More
Cotton sleeves Make : Kirloskar or equivalent

6

-

-

... More
sleeve holder Make : BOSCH or equivalent

6

-

-

... More
Supply only following unsv parts of radiator as under:-

-

-

-

... More
V-belt suitable for DG Set of Capacity 15 to 30 KVA

7

-

-

... More
V-belt suitable for DG Set of Capacity 110 to 125 KVA

4

-

-

... More
Repair of armature by rewinding with the enamelled copper winding wire of existing gauge and connecting at position, testing & commissioning of DG set to the entire satisfaction of AGE E/M upto 125 KVA capacity DG set, complete all as specified & directed.

6

-

-

... More
Taking out old unsv self starter 24 Volts and providing new one company sealed self starter as per the existing size, make , model and type including testing complete all as directed by the Engr-in Charge.

2

-

-

... More
Taking out old unsv self starter 12 Volts and providing new one company sealed self starter as per the existing size, make , model and type including testing complete all as directed by the Engr-in Charge.

3

-

-

... More
Taking out old unsv DG set Controller for AMF Panel of 12 Volts for 15KVA DG set and providing new one company sealed DG Controller for AMF Panel as per the existing size , make , model and type including testing complete all as directed by the Engr-in Charge.

4

-

-

... More
Taking out old unsv DG set Controller for AMF Panel of 12 Volts for 30KVA DG set and providing new one company sealed DG Controller for AMF Panel as per the existing size , make , model and type including testing complete all as directed by the Engr-in Charge.

6

-

-

... More
Taking out old unsv DG set Controller for AMF Panel of 24 Volts for 110KVA DG set and providing new one company sealed DG Controller for AMF Panel as per the existing size , make , model and type including testing complete all as directed by the Engr-in Charge.

1

-

-

... More
Taking out old unsv DG set Controller for AMF Panel of 24 Volts for 125KVA DG set and providing new one company sealed DG Controller for AMF Panel as per the existing size , make , model and type including testing complete all as directed by the Engr-in Charge.

2

-

-

... More
Taking out old unsv DG set Oil sensor controller of 15 KVA to 30 KVA DG set and providing new one company sealed DG set oil sensor Controller for AMF Panel as per the existing size , make , model and type including testing complete all as directed by the Engr-in Charge.

4

-

-

... More
Taking out old unsv DG set Oil sensor controller of 110 KVA DG set and providing new one company sealed DG set oil sensor Controller for AMF Panel as per the existing size , make , model and type including testing complete all as directed by the Engr-in Charge.

1

-

-

... More
Taking out old unsv DG set Oil sensor controller of 125 KVA DG set and providing new one company sealed DG set oil sensor Controller for AMF Panel as per the existing size , make , model and type including testing complete all as directed by the Engr-in Charge.

2

-

-

... More
Taking out old unsv AVR of 110 KVA DG set and providing new one company sealed DG set AVR as per the existing size , make , model and type including testing complete all as directed by the Engr-in Charge.

1

-

-

... More
Taking out old unsv AVR of 125 KVA DG set and providing new one company sealed DG set AVR as per the existing size , make , model and type including testing complete all as directed by the Engr-in Charge.

2

-

-

... More
Taking out old unsv Battery 12 V, 70 AH and providing new one company sealed Battery 12 V, 70 AH as per the existing size , make Exide/ Exide express/Amron, including testing complete all as directed by the Engr-in Charge.

6

-

-

... More
Taking out old unsv Battery 12 V, 120 AH and providing new one company sealed Battery 12 V, 90 AH as per the existing size , make Exide/ Exide express/Amron, including testing complete all as directed by the Engr-in Charge.

3

-

-

... More
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor of size 10 Sqmm nominal cross section x 2 core. 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete all as specified.

300

-

-

... More
Description all as per item No 34.00 above but 16 Sqmm nominal cross section x 4 core.

200

-

-

... More
Description all as per item No 34.00 here-in-before but 25 Sqmm nominal cross section x 3.5 core.

200

-

-

... More
Description all as per item No 34.00 here-in-before but 35 Sqmm nominal cross section x 3.5 core.

200

-

-

... More
Description all as per item No 34.00 here-in-before but 50 Sqmm nominal cross section x 3.5 core.

200

-

-

... More
Description all as per item No 34.00 here-in-before but 70 Sqmm nominal cross section x 3.5 core.

300

-

-

... More
Description all as per item No 34.00 here-in-before but 95 Sqmm nominal cross section x 3.5 core.

300

-

-

... More
Description all as per item No 34.00 here-in-before but 120 Sqmm nominal cross section x 3.5 core.

200

-

-

... More
Supply and fixing in repairs MCB TPN, 415V, 40 to 100 Amps, 'C' series, complete all as specified.

12

-

-

... More
Supply and fix in repairs MCCB 125 Amps, 16 KA, TP, 415 volts with neutral link including aluminium cable lugs all as specified directed.

4

-

-

... More
Supply and fix in repairs MCCB 160 Amps, 16 KA, TP, 415 volts with neutral link including aluminium cable lugs all as specified directed.

5

-

-

... More
M&L in replacement of MCCB 4 Pole, adjustable thermal & fixed magnetic, braking capacity 36KA, 200 Amp complete including fixing in existing LT panel with necessary arrangement complete all as specified and directed.

4

-

-

... More
Taking down old unsv earthing complete and provide new Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground) with top edge of plate not less than 1.5m below normal ground level connecting to the GI earthing strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron and GI Strip 32x6mm protected by provision of GI Light grade pipe of 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregrate with 40mm thick cover of RCC (1:2:4) raniforced with XPM (weight not less than 4Kg/sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and 6mm dia MS bars handle made to shape, GI Light grade 40mm bore pipe for watering perforated at bottom 1.75m long placed on top edge for earth plate incl common salt and charcoal filling, test point made out of 75x50x6mm phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in any type ofsoill, returning filling in and removal of surplus soil to a distance not exceeding 50m all as per electrical plate no 3 of SSR 1991 Pt-I and connecting to earh test point incl testing on completion. Note:- The required resistance of Earthing shall be less than 2 ohm, If not fouund to the required resisstance, the contractor has to re earthing for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance.

20

-

-

... More
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc and getting out in any type soil complete all as specified and directed.

335

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.

180

-

-

... More
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.

160

-

-

... More
Sand cushioning to under ground cable, 8 cms thick before laying the cable and 15 cms thick after laying and stretching the cable in trenches including hand punning and consolidating, punned to 18cm thickness, complete all as specified and directed. Note : For payment purpose, only punned thickness shall be measured.

108

-

-

... More
Brick protection to cable with one layer of sub class 'B' brick, old size,brick covering laid dry, flat, transversally along the length of cable with width equal to the length of brick, complete all as specified and directed.

10.2

-

-

... More
S&F in replacement of 40mm bores of tubes 'light grade' galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable complete all as specified and directed.

48

-

-

... More
Supply, Installation, Fixing and Testing of AMF PANEL for 30KVA D.G Set made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54 in accordance with IEC 60529 and Color code RAL 7032 completely dyed in mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal size should be not less than 590mm x 800mm x 250 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. The Panel box shall have to be equipped with GRP handle lock with THREE point locking mechanism and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Panel Stand Angle Iron of 50x50x5mm and Copper Bus-bar with Heat Shrinkable Sleeves of capacity 100 Amp, TPN. Start/Stop Push Buttons, Auto/Manual Selector Switches, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed :- Make- Hensel/Schneider/ABB/Rittal/Siemens

2

-

-

... More
INCOMMING :- a). MCCB 100Amp 3P 30KA with Thermal and magnetic released with spreader links - 2 Nos ( Main & D.G ) b). 100 Amp Contactors Heavy Duty - 2 Nos c). LED indicator R/Y/B - 3 Sets d). Multi-functional Meter ( Volt,Amp,frequency ) with 3 Nos CT Coils 100/5A - 1 No e). Battery Charger 12V - 10Amp - 1 No f). Control MCB SP 2Amp- 6 Nos g). SM 500 Relay - 2 Nos h). On Delay Tmer - 2 Nos j). 8 Pin Relay - 1 No Note :- AMP Panel with Complete all accessories for Command to D.G Auto Start/Stop and convert in D.G and Electricity.

-

-

-

... More
Supply, Installation and Fixing and testing of AMF PANEL for 125KVA D.G Set made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54 in accordance with IEC 60529 and Color code RAL 7032 completely dyed in mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal size should be not less than 590mm x 800mm x 250 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. The Panel box shall have shall be equipped with GRP handle lock with THREE point locking mechanism and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Panel Stand Angle Iron of 50x50x5mm and Copper Bus-bar with Heat Shrinkable Sleeves of capacity 300 Amp, TPN. Start/Stop Push Buttons, Auto/Manual Selector Switches, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed :- Make-Hensel/Rittal/ABB/Schneider/Siemens

1

-

-

... More
INCOMMING :- a). MCCB 125Amp 4P 25KA with Thermal and magnetic released with spreader links - 2 Nos ( Main & D.G ) b). 125 Amp Contactors - 2 Nos c). LED indicator R/Y/B - 3 Sets d). Multi-functional Meter ( Volt,Amp,frequency ) with 3 Nos CT Coils 125/5A - 1 No e). Battery Charger 12V - 10Amp - 1 No f). Control MCB SP 2Amp- 6 Nos g). SM 500 Relay - 2 Nos h). On Delay Tmer - 2 Nos j). 8 Pin Relay - 1 No k) On load Manual changeover switch 125Amp 4P for bypass arrangement-2Nos. Note :- AMP Panel with Complete all accessories for Command to D.G Auto Start/Stop and convert in D.G and Electricity.

-

-

-

... More
Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for including removal complete all as specified and directed.

45

-

-

... More
75mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base of floor/hardstanding etc, finishing surface even and fair to receive topping layer, complete all as specified and directed.

300

-

-

... More
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.

8

-

-

... More
Machine pressed concrete interlocking paver block any shape, size and colour confirming to IS 15658-2006 of 80mm thickness, M-40 grade with grey cement and pigment over sand cushion including dismantling of existing interlocking paver block complete all as specified and directed. Note:- Sand cushioning shall be measured & paid seperately.

300

-

-

... More
Plain Cement Concrete 1:2:4, B-1 (using 20mm graded crushed stone aggregate) as in copings, hold fasts, plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including use and waste of necessary form work, complete all as specified.

3

-

-

... More
M&L in replacement of on load change over switch, 4 pole, capacity 160 Amp with SS enclosure complete incl fixing on wall, open execution type with necessary fixing arrangement complete all as specified and directed.

3

-

-

... More
M&L in replacement of on load change over switch, 4 pole, capacity 200 Amp with SS enclosure complete incl fixing on wall, open execution type with necessary fixing arrangement complete all as specified and directed.

3

-

-

... More
LED light luminaire 600mm x 600mm 35/36 watt, 220 Volts AV recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, Holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make- Havell Cat part No-PLUTONEO2X2PLR28WLED840S or equivalent of Make-Phillips, Crompton, wipro, bajaj as approved.

15

-

-

... More
Supply and fixing in replacement “Lithium based Energy Efficient Integrated Solar Street Light of 24 Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 53/55Wp , Lithium Battery 11.1/12.8V, 28.6AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI 70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 12-14kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. CAT part No- SOLAR AIO 24 W of Make Havells or equivalent cat part of Make as specified in list of make here in after as spproved by GE..

6

-

-

... More
Supply and fixing in replacement of battery charger set of capacity 24 Volt including charging lead with holding clamps, digital volt meter, ampere meter, SPN MCB 10 Amp for controlling DC circuit complete all as specified and directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.