Military Engineer Services Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_629987_1Bid Award Id
ViewTender No
8756/2023-24/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR MAINTENANCE OF LT PANEL FEEDER PILLAR AND CONNECTED WORKS AT ZONE 1 UNDER GE (U) BATHINDA..
REPAIR MAINTENANCE OF LT PANEL FEEDER PILLAR AND CONNECTED WORKS AT ZONE 1 UNDER GE (U) BATHINDA..
REPAIR MAINTENANCE OF LT PANEL FEEDER PILLAR AND CONNECTED WORKS AT ZONE 1 UNDER GE (U) BATHINDA..
BOQ Items
... More
M&L in replacement of Aauminium lugs for LT cables 95 to 300 sqmm complete all as directed.
100
-
-
... More
S&F in repair cable joint kit 1100 Volts heat shrinkable straight through for cable of size above 185 to 300 sq mm complete all as directed
5
-
-
... More
Supply,Fixing and testing in repair LT Air circuit breaker 800 Amp . 4 pole , 415 volts , 50 Hz, 65 KA, thermal magnetic release Manual draw out type complete all as per manufacturers instructions and as directed.
2
-
-
... More
Supply, fabricating, installation, testing , commissioning and electrically connecting in repair LT panel Board CPRI approved of size 120cm x 120cm x 50 cm , 415 volts ,factory made , machine pressed , dust and vermin proof , out door type made with CRCA sheet 3.15 mm thick , LT Panel internally and externally shall be painted with expoxy powder coating paint & two coats primer, before being given the stove epoxy finish. , both side opening in two halves with rubber beading , including AL bus bar of 630 Amp capacity , 4 strip mounted on porcelain insulator , bus bar chamber and shall be provided with inspection covers , Each MCCB / Cubical switch shall have the indipendent opening panel and shall be mounted on angle iron frame and legs made from angle iron of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer , embeding and grouting in PCC (1:2:4) type B:1 using 20 mm graded crushed stone aggregate in foundation including necessay earth work complete ,including all connections to MCCBs incoming/outgoing with suitable size of AL bus bar comprising of following accessories including testing complete all as directed
(a) MCCB 4 pole 415 volts 350 Amp rating with breaking capacity 36 KA, adjustable thermal 70-100%-and fixed magnetic setting lcs = 100% lcu .- 01No. (incoming) (b) MCCB 4 pole 415 volts 160 Amp rating with breaking capacity 36 KA, adjustable thermal 70-100%-and fixed magnetic setting lcs = 100% lcu = 02 Nos. (outgoing).
(c) MCCB 4 pole 415 volts 100 Amp rating with breaking capacity 25 KA, adjustable thermal 70-100%-and fixed magnetic setting lcs = 100% lcu = 02 Nos (outgoing). (d) Spare pocket for fixing of 01 No. MCCB with separate compartment - 02 Nos. (e) Multifunction meter for measuring ampere,voltage, frequency & CTs of suitable ratio etc complete - 1 No
(f) Indicator lamp R,Y,B = 01 Set of three.
9
-
-
... More
Material & Labour for disconnecting the LT cable connections from panel MCCBs/MCBs and removing the carbon from the contacts by cleaning through CTC SOLUTION , if the cable insulation is deterioated Excavate the loop of the cable and make new connection with suitable size of lugs including replacment of the unserviceable or defective parts i.e rusted nuts, bolts,old damged/ corroded door hinges /door lock/bus bar, front or back door etc (doors hinges, door lock shall be weld properly) and reassemble the panel with all the connection properly tight and checked.Control wiring and CT PT connection of the panel shall be proper to be made serviceable to the entire satisfaction of the Engineer in Charge. Foundation of the panel shall be repaired with existing specifications if deteriorated and coloured with base frame properly mounted complete all as specified and directed by the Engineer in Charge.
30
-
-
... More
S&F in repair cable joint kit 1100 Volts heat shrinkable end termination kit indoor / outdoor type for cable of size 70 to 150 sqmm complete all as directed.
15
-
-
... More
Supply , Fixing , installation, commissioning and testing in repair LT junction box cubical type of size 60cm x 40cm x 30 cm, 415 volts for outdoor use made of CRCA sheet 3.15 mm thick powder coated ,machine pressed front opening with single door with MCCB 100Amps 4Pole 25 kA provision of rubber beading and locking system including aluminium bus bar 4 strip of size 30 mm wide and 6 mm thick with provision of hole on bus bar for fixing of cable mounted on PVC / epoxy insulators, mounted on angle legs of size 25mm x 25mm x 5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer ,legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded crushed stone aggregate) including all provision of opening for incomming/outgoing cables and testing complete all as directed. Note for serial item No. 01 to 03: The make of CRCA sheet shall be of TATA / SAIL/ RINL/ JINDAL. Purchase Vr to be produced at the time of payment.
10
-
-
... More
Material and Labour for repairing the LT panel board body by replacing with new CRCA sheet of existing gauge size and shape for door / body of Pane/feeder pillar box, with hinjes and door lock should be well welded complete all as specified and as directed.
4
-
-
... More
S&F in repair cable joint kit 1100 Volts heat shrinkable end termination kit indoor / outdoor type for cable of size 185 to 300 sqmm complete all as directed.
10
-
-
... More
Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size 2 to 4 core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junction box/LT panel/O/H line complete all as directed. Note:-
(I) the cost of required excavation, returning filling, relaying sand cushioning /brick protection and cost of drawing the required length from protection pipe, breaking of required brick work/plaster/concrete and redoing the same with required cement work to match the existing surface is deemed to be included in the quoted rate of thi item and nothing extra shall be paid on this account.
(ii) Additional cable/ protection pipe required at site shall be measured and paid seperatly.
200
-
-
... More
S&F in repair cable joint kit 1100 Volts heat shrinkable end termination kit indoor / outdoor type for cable of size 25 to 50 sqmm complete all as directed.
10
-
-
... More
M&L in replacement of Aauminium lugs for LT cables 300 to 500 sqmm complete all as directed.
50
-
-
... More
S&F in repair cable joint kit 1100 Volts heat shrinkable straight through for cable of size 10 to16 sq mm complete all as directed.
10
-
-
... More
S&F in repair cable joint kit 1100 Volts heat shrinkable straight through for cable of size 70 to 150 sq mm complete all as directed
20
-
-
... More
Surface cleaning/site clearance n exc 15 cm in depth in Sub stations area, trenches,sub station rooms, two pole/ four pole structure surroundings to make a over all presentable condition all as directed by Eng In charge.
4000
-
-
... More
M&L in replacement of Aauminium lugs for LT cables 10 to 70 sqmm complete all as directed.
100
-
-
... More
.Supply and lay graded stone aggregate of size 40mm graded layed on ground of yard/ two/four pole structure complete all as specified and directed.
50
-
-
... More
S&F in repair cable joint kit 1100 Volts heat shrinkable straight through for cable of size 25 to 50 sq mm complete all as directed
10
-
-
... More
S & F in repair indicator lamp in differenet colour code LED / Neon type (as per sample) complete (RYB) including wiring with copper conductor cable of suitable size complete all as directed.
25
-
-
... More
M&L for in repairs earthing complete with Galvanized Iron electrode 60cmx60cmx3.15mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GIr strip of size 25x4mm by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dully all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of Soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed.
Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth strip
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements