Zilla Parishad Tender
... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Zilla Parishad - ZP Tender
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date12 Mar 2025
Closing Soon20 Mar 2025
Tender Amount₹ 9,60,215
Costs
EMD
₹ 19,204Document Cost
₹ 750Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_ZPHD_826619_1Tender No
eNIT.28.Solar.5th.SFC.CGPTender Authority
Zilla Parishad ViewPurchaser Address
-Website
http://https://www.udzp.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of ACDB & DCDB : Designed for 10 kWp Hybrid solar power plant with all protections as per MNRE guidelines.DC DPBs shall have sheet from enclosure of dust & vermin proof conform to IP 65 protection. The bus bars are made of copper of desired size. Suitable capacity fuse & MCBs/MCCB shall be provided for controlling the DC power output to the PCU along with necessary surge arrestors and suitable battery MCB's are used between Battery and solar PCU in DCDB . AC Distribution Panel Board (DPB) shall control the AC power from PCU/ inverter, and should have necessary surge arrestors. Interconnection from ACDB to mains at LT Bus bar while in grid tied mode.All switches and the circuit breakers, connectors should conform to IEC 60947, part I, II and III/ IS60947 part I, II and III. All the Panel’s shall be metal clad, totally enclosed, rigid, floor mounted, air - insulated, cubical type suitable for operation on three phase / single phase, 415 or 230 volts, 50 Hz.All indoor panels will have protection of IP54 or better. All outdoor panels will have protection of IP65 or better.
1
19948
19948
... More
Supply of Grid tie solar PCU Rating : 10KW, 1Ph Inverter – 1 Nos with nominal DC voltage 96-120 V DC., Make: Exide/Luminos/Loom/Eapro/Equivalent : Microprocessor /DSP. Hybrid Inverter .Nominal AC output voltage : 230V, 1 Phase, . Output frequency : 50 Hz . Max. DC input Power 6kW. MPPT Voltage Range 60 - 600 VDC. . Output Voltage Range - 180V - 260 V AC. Grid Frequency Synchronization range : +/- 5 %. Ambient temperature considered : -10℃ to 55 ℃. Humidity : 90 % Non-condensing. Protection of Enclosure :: IP-21(Minimum) for Indoor. Grid Frequency Tolerance range : +/- 5 %. Grid Voltage tole rance : 180 V to 260 V. No-load losses : Less than 1% of rated power. Inverter efficiency 92%. THD : 3%. Efficiency Measurement IEC 61683/ Equivalent BIS Std.Environmental testing IEC 60068-2 (1,2,14,30) / Equivalent BIS Std.Interfacing with utility grid IEC 61727. Islanding Prevention Measurement IEC 62116. EMI/EMC : IEC 61000-6-316 Amps IEC 61000-6-416 Amps. Safety: IEC - 62109-1 (2010/4) C - 62109-2 (2011/6). All above IEC’s should be from NABL/ IEC Accredited Testing Laboratories or MNRE Approved Test Centers/ International laboratories.
1
170230
170230
... More
Supply instalation and commissioning 1200 AHM 96V, low maintanence solar tubolar plate battery with battery bank (Make: Exide/Luminos/UTL/Eapro/Equivalent)
8
22196
177568
... More
Supply of System Earthings : Each array structure of the PV yard should be grounded/ earthed properly as per IS:3043-1987. In addition the lighting arrester/masts should also be earthed inside the array field, PCU, ACDB and DCDB should also be earthed properly. Earth resistance shall not be more than 5 ohms. It shall be ensured that all the earthing points are bonded together to make them at the same potential.
3
15988
47964
... More
Lightning Protection: The SPV power plants shall be provided with lightning &overvoltage protection. The main aim in this protection shall be to reduce the over voltage to a tolerable value before it reaches the PV or other sub system components. The source of over voltage can be lightning, atmosphere disturbances etc. The entire space occupying the SPV array shall be suitably protected against Lightning by deploying required number of Lightning Arrestors. Lightning protection should be provided as per IEC standard. The protection against induced high-voltages shall be provided by the use of metal oxide varistors (MOVs) and suitable earthing such that induced transients find an alternate route to earth.
2
8000
16000
... More
Supply of Cables DC & AC: Sizes of cables between array interconnections, array to junction boxes, junction boxes to Inverter, Battery to Inverter etc. shall be so selected to keep the voltage drop of the entire solar system to the minimum. The cables (as per IS) should be insulated with a special grade PVC compound formulated for outdoor use. The size of each type of DC cable selected shall be based on minimum voltage drop however; the maximum drop shall be limited to 1%.
The size of each type of AC cable selected shall be based on minimum voltage drop however; the maximum drop shall be limited to 2 %. i. Shall meet IEC 60227/IS 694, IEC 60502/IS1554 standards.
1
29030
29030
... More
2:1, 3:1, 1:1 Male-female MC4 connector……….etc complete.
40
150
6000
... More
Installation, Testing & Commissioning including Maintenance with Foundation of Mounting Structure..
1
50257
50257
... More
Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750 x 37 mm. thick made with RCC 1:1½:3 with pakur variety stone chips reinforced with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts & bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750 mm. is of section 100 x 13 mm. and 1.90 metre above GL & 0.75 metre below GL including digging hole, repacking the same with cement concrete 1:3:6 with jhama khoa or with local stone chips etc. complete including painting two coats on both faces lettering sign marks etc. as per direction of the Engineer-in- Charge. (The rate is inclusive of cost of reinforcement, concrete, shuttering, nuts & bolts, washer etc. complete.)
1
2230
2230
... More
Add CGST and SGST=9+9=18%
1
145023
145023
... More
Add L.W. Cess=1%
1
9507
9507
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%