Zilla Parishad Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Zilla Parishad - ZP Tender
Civil And Construction
Building Construction
Eprocure
Opening Date2 Sep 2024
Closing Date17 Sep 2024
Tender Amount₹ 19,52,919
Costs
EMD
₹ 39,058Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ZPHD_741260_1Bid Award Id
ViewTender No
WBZP/15/DE-ET/COB/2024-25Tender Authority
Zilla Parishad ViewPurchaser Address
-Website
http://http://www.coochbeharzillaparishad.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Submit Documents like PAN, GST,ITCC,TL, P.DEED,WorkOrder,Credential,PC,FORMs, Annex,PLBsheet etc.
BOQ Items
Cement concrete with 30 mm down graded shingles
excluding shuttering. In ground floor 1:3:6 proportion
20.39
100969
4951.93
Ordinary Cement concrete (mix 1:1.5:3) with graded
stone chips (20 mm nominal size) excluding
shuttering and reinforcement, if any, in gound floor
as per relevant IS codes.
38.86
218969
5634.83
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. TATA/SAIL/RINL
3.66
262757
71752.32
Hire and labour charges for shuttering with
centering and necessary staging upto 4 m using
approved stout props and thick hard wood planks
of approved thickness with required bracing for
concrete slabs, beams and columns, lintels curved
or straight including fitting, fixing and striking out
after completion of works (upto roof of ground floor) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. (ground Floor).
135.94
53140
390.91
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating, nosing and drip course where necessary (ground floor). With 1:6 cement mortar 20 mm thick plaster
85.75
16044
187.11
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating, nosing and drip course where necessary (ground floor). With 1:6 cement mortar 15 mm thick plaster
85.75
14103
164.47
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In ground floor,( 25 kg /M2 & 16 kg /M2 )
0.53
4813
9168.52
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor, (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr
4.8
41062
8554.74
Lime punning about 3 mm. thick with stone lime and shell lime (1:2)
171.5
16556
96.54
P.V.C Partition:
Supplying,fitting and fixing the partition,frame will be made with rectangular steel tube of size 50mm x 25mm with wall thickness not less than 1.00mm. The vertical members duly welded to the horizontal members shall be placed between
1000mm to 1200mm apart the entire partition frame will be securedly fixed to the wall, ceiling and floor using rawlplug or wooden gutties and screws etc.the frame will be painted with synthetic paint, the section of the partition frame will then fitted with PRINTED LAMINATED P.V.C extruded hollow section of size 100mmx25mm. panel with approved quality fixed in the place by means of P.V.C extruded beading on both sides or P.V.C extruded angles (20mmx18mm) on one side and P.V.C extruded beading (9mmx9mm) on other side ,angle/beading will be fixed to the steel frame by 19mm (nos.6) self tapping steel screw placed at an interval of 450mm and complete in all respect as per direction of Engineer-inCharge with all labour and materials In ground floor..
28.8
67652
2349.04
Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted
and fixed complete as per design (excluding the supporting framework but
including local sal wood battens of size 37.5mmx25mm).
In ground floor. (a) 19mm mesh
27
12839
475.53
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (b) Two Coats,i) Water based interior grade Acrylic Primer
85.75
4517
52.68
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor:(b) Two Coats
85.75
4609
53.75
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
85.75
7154
83.43
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.
In Ground floor (Two Coat) a) Normal Acrylic Emulsion
85.75
6847
79.85
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
75
2592
34.56
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) -(ii) Two coats (white in shade)
52.2
4790
91.77
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work (c) (i) With carried earth arranged by the contractor within a radius of 1 km. including cost of carried earth
44.63
16633
372.69
Brick work with 1st class bricks in cement mortar (1:6). In foundation and plinth
6.15
35511
5774.27
125 mm thick Brick work with 1st class bricks in cement mortar (4:1) in Ground floor.
67.65
53857
796.12
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer....., labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e)I (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colour
105
158176
1506.44
P.V.C- False Ceiling :
Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended .......including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineerin-Charge . In ground floor.
105
174443
1661.37
Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping) (A) 300 mm lapping each way, (c) With 0.80 mm sheet
17
9097
535.12
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:- a) With 0.5 mm thick sheet
196.5
339573
1728.11
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved
make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes t..... The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or parthereof. i) For roof truss works a) Span up to 12 Mtr
1.65
124044
75178.74
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) ...... on finished length of the work).
(A) In 10-12 Micron thickness Annodizing film
I) Natural white,c) 4- track sliding window
-
-
-
i) Bottom frame
24
10754
448.12
ii) Top and side frame.
48
18534
386.14
k) Movable door shutte,i) Door frame. (Top & sides).
5.4
2027
375.42
ii) Shutter :
-
-
-
Top rail
1.2
434
362.31
Bottom rail
1.2
640
533.93
Lock rail
1.2
539
449.31
Door vertical
4.2
1661
395.68
Glazing cleap
18
1072
59.59
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium
sections for the following units:-
(A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter f...... all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. ii ) 3 /4 track sliding window.
28.8
32298
1121.48
Supplying heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge
1
2060
2060.62
Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction of Engineer-in-Charge,(c) 300 mm long
2
176
88.19
Supplying PVC rollers for sliding windows as per direction of Engineer in charge.
80
1335
16.69
Supplying maruti lock (100mm)
80
4385
54.82
Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.i) For sliding windows,b) 'U' shaped EPDM gasket for frames.
144
2574
17.88
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987,viii) 8mm thick coloured / tinted / smoke glass.
31.32
40388
1289.53
Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width,(a) Ground Floor
4.2
345
82.23
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements