Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Zilla Parishad - ZP Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date24 Apr 2023
Closing Date8 May 2023
Tender Amount₹ 12,84,585 
Notes
Download

Costs

Summary

Banarhat/bdo/nit-002/23-24 (2nd Call)/03

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
P 47,It No. 3 SSupplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

154.61

3710

24

... More
P 34,It No.22 (II) Cement concrete with 30 mm down graded shingles excluding shuttering ( N.B. Variety.) In ground floor (1:3:6 proportion

12.82

43498

3393

... More
(Item No.- 4; Page No.- 24 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (b) River bazree Plinth Protection

2.89

11577

4006

... More
P 26,It No.10 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size)excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (ii ) River Bazree

32.6

154687

4745

... More
P 43,It No.40 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. other than steel JSW/JSPL/SHYAM/SRMB/BNASL/Ecectrosteel/SSL

3.07

197226

64243

... More
P42,It No.36 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation

57.45

11777

205

... More
(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.

182.03

59705

328

... More
P 150 It No.8 Brick work with 1st class bricks in cement mortar (1:6) In superstructure, ground floor

7.22

35349

4896

... More
P 16 It No.16 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

112.74

75986

674

... More
P 189,It No.1 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar(For Exterior Wall)

76.32

9616

126

... More
10 mm thick plaster(For New Work)

221.21

34729

157

... More
15 mm thick plaster(Outside)

140.16

25368

181

... More
20 mm thick plaster

23.4

795

34

... More
P 192,It No.15 Neat cement punning about 1.5mm thick in wall, Neat cement punning about 1.5mm thick in wall, dado, window,sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.

4.99

44632

8948

... More
I- 12, P- 104 M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame) with or without intermediate flat bar stiffener and fixed with necessary screws etc. complete, as directed.

19.95

26014

1304

... More
I- 15, P- 105 Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.

5.01

50205

10021

... More
It.- 13; P No.- 104 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.

52.65

38908

739

... More
(Item No.- 35; Page No.- 64 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative

23.08

17194

745

... More
(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative

7.17

12102

1688

... More
(Item No.- 36; Page No.- 66 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (A) Deep Colour & White

27.73

12949

467

... More
(Item No.- 46; Page No.- 74 Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling Red Variety (i) 25 mm. thick

69.69

2021

29

... More
P 200,It No 1 a)Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

69.69

5505

79

... More
P 200,It No 2 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary (b) On steel or other metal surface : [With super gloss (hi-gloss)] (iv) Two coats (with any shade except white)

114.64

13986

122

... More
IT - 5, P-198 Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)

114.64

8024

70

... More
P 196 It No10 Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification), including cleaning and smoothning of surface. Two Coats

118.63

5350

45.1

... More
P 196,It No8 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (b) Two Coat

118.63

7948

67

... More
IT-17, Page- 197 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.

7.2

3715

516

... More
IT-19, Page- 128 Supplying, fitting & fixing factory made foam PVC (density shall not be less than 600 kg/cum) door frame (finished weight of 2.73 kg/mtr.) of size 100mm X 45mm made off with 5mm thick extruded foam PVC sheet, mitre cut at junction of horizontal and vertical member and joined them by heat welding. Entire door frame profiles to be reinforced with steel primer coated 19 SWG 40mm X 20mm M.S. tube. An additional 5mm thick PVC sheet with desired colour/shade to be provided at the exposed surface and three nos 5mm thick PVC sheet to be provided as gap insert. The door frame to be fixed with wall by using 8mm dia. and 100mm long strainless steel screws and PVC fasteners. A minimum of 4 nos. screws to be provided for each vertical member & 2 nos. for horizontal member all complete as per direction of Engineer-in-Charge. (a) Plain Colour.

3.15

7679

2438

... More
IT-16, Page- 126 Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in Charge.

1

7000

7000

... More
Bala model painting (As per voucher)

1

20000

20000

... More
ECCE Materials(Toys for kids, Outdoor Playing equipments, Portable Playing equipments, Ghonta /Bell, with wooden hammer, Water Purifier, Display board. Pressure Cooker 5 ltr, Wall Clock, Mirror, Steel Food Containers etc. (Payment will be made asper voucher)

1

9000

9000

... More
Gas connection with fire extinguisher (Payment will be made asper voucher)

1

15000

15000

... More
Electrification (Payment will be made asper voucher)

1

33283

33283

... More
SANITARY & PLUMBING WORKS IT-3, Page- 88 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. i) For 10 users B) With Bazree (N.B Varity) (Other than SAIL/TATA/RINL)

1

15431

15431

... More
IT-4, Page- 89 Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. Other than SAIL/TATA/RINL)

1

2584

2584

... More
Item-6/ Page-37 Supplying PVC water storage tank of approved quality with closed top with lid (black)-multilayer. a) 500 litre capacity

1

96

96

... More
IT-10, Page- 37 Labour for hoisting plastic water storage tank i) Upto 1500 litre capacity (a) Upto 1st story from G.L.

1

19

19

... More
IT-13, P- 38 Labour for punching hole in plastic water storage tank upto 50 mm dia.

10

890

89

... More
IT-7fii, Page- 6 (ii) Polythene Bib Cock / Stop Cock with plastic inlet (EMCO / ATLAS or equivalent) 15 mm

1

1522

1522

... More
IT-4, Page- 79 Orissa Pattern W.C in white glazed vitreous chainaware of approved brand.....i) 580mm x 440 mm (ii) 530 mm X 410 mm

18

1818

101

... More
Item-19(i)/ Page-12 Supplying ,fitting & fixing PVC pipes of approved make of (medium duty) conforming to ASTMD-1785 and threaded to match GI pipes as per IS: 1239 (part-I). With all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple...........................(payment will be made on the centre line measurment of total pipe line including all specials.. a) for exposed work PVC pipes 15mm dia

14

2478

177

12

2832

236

1

948

948

... More
IT-14, Page- 65 Supplying,fitting and fixing cast iron 'P' or 'S' trap conformimg to I.S. 3989/ 2009 and 1729/ 2002 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). A) 'P' Trap iii) 100 mm

1

688

688

... More
IT-1, Page- 60 Supplying, fitting & fixing Cast iron soil pipe only conforming to I.S. 3989/ 2009 and I.S. 1729/2002 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the center line of the total pipe line in fitted condition including specials,payment for specials & Painting will however be paid seperately). (ii) 100 mm dia. (internal)

1

848

848

... More
IT-11, Page- 53 Supplying, fitting and fixing chech valve (vertical) G.M. tested to 21 kg per sq. cm. v) 40 mm

1

450

450

... More
Buster pump for uplifting water from hand tubewell to over haed tank

1

1590

1590

... More
IT-5, Page- 5 Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (v) 40 mm dia

1

2297

2297

... More
Item-1/ Page-36 S/F/F white vitreous china best quality approved make wash basin with C.I brackets on 75x75mm wooden blocks C.P waste fittings of 32mm dia, one approved quality brass C.P pillar cock of 15mm dia , C.P chain with rubber plug of 30mm dia approved quality PVC waste pipe with C,P nuts 32mm dia, 900mm long approved quality PVC connection pipe with heavy brass C.p nut including mending good all damages and painting the brakets with two coats of approved paint. S/F/F 0.50HP pump

1

5000

5000

... More
(Hand Tubewell) IT-1, Page- 49 Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (i) 40 mm dia. boring etc.

35

3150

90

... More
IT-1, Page- 102 Supply of G. I. pipes of TATA make including necessary sockets e) 40 mm dia. ii) Medium quality

1

291

291

... More
IT-19(i), Page- 12 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) 40 mm

32

9344

292

... More
IT-6, Page- 52 Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. i) 40 mm dia.

1.8

527

293

... More
IT-10, Page- 53 Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. (i) 40 mm

1

51

51

... More
IT-9, Page- 53 Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. i) 40 mm dia.

1

124

124

... More
IT-14, Page- 54 Supplying, fitting and fixing popular Maya pump no-6 or similar. (i) For 40 mm dia. tube well

1

1596

1596

... More
P 14,It No 1 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

2.5

810

324

... More
P 34,It No.22 (II) Cement concrete with 30 mm down graded shingles excluding shuttering ( N.B.Variety.) In ground floor (1:3:6 proportion)

0.5

1696

3393

... More
P 48,It No.6 Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item isnot permitted with ordinary cement).Using grey cement i)25 mm. thick

4

1080

270

... More
Add:- GST @ 18%

1

194013

194013.47

... More
Add:- Cess @ 1%

1

12718

12718.66



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.