Zilla Parishad Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Zilla Parishad - ZP Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date12 Sep 2024
Closing Date21 Sep 2024
Tender Amount₹ 3,49,986 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
PWD S&P SCHEDULE, PAGE NO. 53, ITEM 10(ii) Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. (ii) 50 mm

1

71

71

... More
PWD S&P SCHEDULE, PAGE NO. 53, ITEM 12(vi) Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm. (vi) 50 mm

1

2203

2203

... More
PWD S&P SCHEDULE, PAGE NO. 54, ITEM 17(i) Supplying, fitting and fixing heavy type bell mouth reducing socket. (i) 50 mm X 100 mm

1

455

455

... More
PWD S&P SCHEDULE, PAGE NO. 56, ITEM 27 Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.

1

2235

2235

... More
PWD S&P SCHEDULE, PAGE NO. 102, ITEM 1 Supply of G. I. pipes of TATA make including necessary sockets (d) 32 mm dia. (ii) Medium quality

12

3072

256

... More
(f) 50 mm dia. (ii) Medium quality

21

8442

402

... More
(i) 100 mm dia. (i) Medium quality

20

16600

830

... More
PWD Building SCHEDULE, Page - 99 / Item -1 M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m

0.7

42161

60230

... More
PWD Building SCHEDULE,Page - 1 / Item -2 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.

6.62

789

119.27

... More
PWD Building SCHEDULE,Page - 35 / Item -22. II) (II) Cement concrete with 30 mm down graded shingles excluding shuttering.

0.91

3087

3393

... More
PWD Building SCHEDULE,Page - 26 / Item -10. ii) Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (ii ) River Bazree

1.71

8113

4745

... More
PWD Building SCHEDULE,Page - 42 / Item -36. Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.

10

3280

328

... More
PWD Building SCHEDULE,Page - 43 / Item -40. Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel II. Other than SAIL/TATA/RINL

0.2

13100

65502

... More
PWD S&P SCHEDULE,Page - 29 / Item -a) ii) Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (ii) CPVC Pipes Class-2,SDR-13.5 From Storage Tank to Stand Post 25 mm

24

4320

180

... More
PWD S&P SCHEDULE,Page - 37/Item -6 Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (b) 1500 litre capacity

1

7840

7840

... More
PWD S&P SCHEDULE,Page - 7 / Item -7. g) (g) Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. (i) 15 mm

2

338

169

... More
PWD Building SCHEDULE,Page - 200/Item -1. a) ((b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)

20

580

29

... More
PWD Building SCHEDULE,Page - 200 / Item - 2. b) iv) (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)

20

1580

79

... More
WRDD SCHEDULE,Page - 109 / Item - 1(b) Supply , transport , installation and commissioning of Solar PV installation for water pumping system with fixed structure consisting of solar panels framed in anodized aluminium frame mounted on stable hot dipped galvanized (with 80 micron thickness) mild steel structure of sufficient strength which can withstand load of modules and high wind velocities upto 150 Km/hr, having RCC foundation designed against all possible loads (Dead, Live and imposed load). Modules supplied with the SPV system should have certificate as per IEC 61215 specification or equivalent National or International standards and must be interconnected with 4/6 sq.mm cables routed in PVC conduits properly fitted along the G.I structure to provide a good aesthetic view. Modules must qualify to IEC 61730 part I and part II for safety qualification testing. The power output of individual PV modules used in the PV array, under STC, should be a minimum of 250 Watts peak, with adequate provision for measurement tolerances. Solar cells should be crystalline silicon cell with min. efficiency of 14% and fill factor more than 70%, should be laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2mm tempered glass including appropriate DC to AC inverter and power controlling unit (protected with IP65 class enclosure) with MPPT technology to run at low sunshine and minimum 5 hours a day run with all necessary accessories suitable for solar + grid operation and including all protections of AC induction motor pump. There should be a display of all measurable parameters including storing of data at a set interval and transfer it in a pendive thru USB port . There should also be provision of interfacing GPRS based data transmission. (The rate is inclusive of manufacturer's warranty and comprehensive maintenance for 1st year and comprehensive maintenace for 4 years beyond Ist year)

1050

121800

116

... More
WRDD SCHEDULE,Page - 114 / Item - 2(i) Supplying , fitting and fixing of Sand Filter - Manual as per IS:14606 Sand Filter10m³/hr-M Single

1

17192

17192.81

... More
PWD Electrical SCHEDULE,Page - G-1 / Item - 2. a Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe

1

1464

1464.83

... More
PWD Electrical SCHEDULE,Page - G-2 / Item - 5. a(i) Connecting the equipment to the earth busbar incl. S&F GI wire of size bellow on wall /floor as required and making connection to the equipment with bolts, washers, cable lugs etc. as required and mending good damages. No 4 SWG GI wire

20

385

19.26

... More
WRDD SCHEDULE,Page - 80 / Item - 2(b)(i) Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.) (b) 30 cubic metre per hour capacity electro motor pumping set. (i) Length of pump assembly not exceeding 18 metre length

1

617

617

... More
WRDD SCHEDULE,Page - 77 / Item - 18 Supplying 1 m × 0.6 m × 24 swg MS board containing list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.

1

1000

1000

... More
Supply of 1 HP oil fill AC solar submersible pump motor set complete having suitable dischage as per yeld test of well. Submerisble cable of 30mtr 3 core 2.5 sqmm that cable (Finolex) with MOC bar chart (Kriloskar make Pump)

1

12500

12500

... More
Add:- GST @ 18%

1

52859

52859.05

... More
Add:- Cess @ 1%

1

3465

3465.2



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.