Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Zilla Parishad - ZP Tender

Works
Civil And Construction
Eprocure
Opening Date4 Oct 2024
Closing Date24 Oct 2024
Tender Amount₹ 74,23,764 
Notes
Download

Costs

Summary

Construction Of Solar Base Drinking Water Scheme 5 Nos. At Different Places Within Cooch Behar

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

130.07

49913

383.76

... More
Cement concrete with 30 mm down graded shingles excluding shuttering In ground floor 1:3:6 proportion

9.76

39446

4043.77

... More
Brick work with 1st class bricks in cement mortar (1:6). In foundation and plinth

16.71

97474

5835.05

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Ground Floor

41.72

238984

5728.98

... More
First Floor.

19.59

114472

5843.39

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction TATA/SAIL/RINL

4.91

365259

74390.95

... More
First Floor.

2.31

172652

74903.42

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) 25 mm to 30 mm shuttering without staging in foundation

88.6

21645

244.31

... More
25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. (ground Floor)

236.55

92469

390.91

... More
First Floor.

182.45

75235

412.36

... More
125mm thick Brick work with 1st class bricks in cement mortar (4:1) in Ground floor

206.2

165634

803.27

... More
First Floor.

66

53959

817.57

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (First floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar 20 mm thick plaster Ground floor

260.3

49946

191.88

... More
First Floor.

66

12978

196.64

... More
With 6:1 cement mortar. 15mm thick plaster Ground floor

240.3

40380

168.04

... More
First Floor.

66

11405

172.81

... More
With 4:1 cement mortar 10 mm thick plaster. Ground floor

100.15

15038

150.16

... More
First Floor.

159.55

24908

156.12

... More
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. Ground floor

390

15802

40.52

... More
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats

586

48889

83.43

... More
Applying Exterior grade Acrylic primer of approved quality and brandon plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterioremulsion paint including scraping and preparing the surface throughly,complete as per manufacturer's specification and as per direction of the EIC Two Coats

306.3

16463

53.75

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer Premium 100% Acrylic Emulsion

306.3

30663

100.11

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. (20mm thick) 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary

51.55

15215

295.16

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame Sal: Siliguri

0.51

43706

85698.76

... More
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) 40mm X 6mm, above 170mm upto 250mmLength

70

2335

33.37

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 58mm. X 1.90mm.

60

3360

56.01

... More
75mm. X 40mm. X 1.12mm.

40

1334

33.37

... More
Iron socket bolt of approved quality fitted and fixed complete. 150mm long x 10mm dia bolt.

20

1501

75.08

... More
Iron socket bolt of approved quality fitted and fixed complete. 225mm long x 10mm dia bolt.

5

456

91.27

... More
Iron catch hook of approved quality fitted and fixed to shutter and chowkat. 6mm dia x 225mm long.

10

762

76.27

... More
Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. 300mm long

5

989

197.83

... More
Iron door ring of approved quality fitted and fixed with nut and washer complete. 75mm dia.

10

333

33.37

... More
50 mm dia.

40

810

20.26

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: With round base: 150 mm grip x 10 mm dia rod.

20

2049

102.49

... More
Z-batten shutters of door and window as per design havings tongued and groove-half lap jointed as per direction of the Engineer-in-Charge including fitting and fixing shutter in position, but excluding the cost of hinges and other fittings in ground floor. Shutter with 25mm thick planks, 19mm thick battens. Sishu, Gamar, Champ, Badam, Bhola, Morga, Hallak.

19.3

60172

3117.74

... More
M.S. structural works with hollow sections ( square or rectangular shape) conforming to IS: 806-1957 & IS:1161-1958) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.

1732.8

153387

88.52

... More
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. For depth upto 150 metre for 80 mm dia. Tube well with top enlargement of 150 mm dia. 80 mm dia. boring etc

360

84520

234.78

... More
150 mm dia. boring etc. top enlargement

120

97965

816.38

... More
Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications. 80 mm dia.

30

29318

977.28

... More
Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. 75 mm

5

2401

480.3

... More
Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm.(vi) 50 mm

5

13127

2625.53

... More
Supplying, fitting and fixing heavy type bell mouth reducing socket. 75 mm X 150 mm

5

3670

734.15

... More
Supplying, fitting and fixing G.I. cap at top 150 mm

5

2997

599.48

... More
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.

5

44918

8983.78

... More
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.

5

12090

2418.16

... More
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.

5

7335

1467.1

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). PVC Pipes (Dia) 80 mm

300

206658

688.86

... More
150 mm

120

203082

1692.35

... More
Solar Module: Supply, transport, installation and commissioning of lSI marked as per IS 14286 and IEC 61853(1). 61730(1&2), 61710 certified Solar Module of Multi crysta lin elM anocrvs tilIIine/ Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity .3.2/4: mm tempered glass, framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. (As per direction of EIC) c)For 1 HP Off-grid Solar Water Pumping System with Monocrystalline/ Monocrystalline PERC/bifacial SPV modules - 5600-5700 Wp. W.R.I D.D. Schedule of Rates 2021,ch. 12, item no. 1) C) BRAND-HAVELS/ PHILIPS

10000

384800

38.48

... More
Power conditioning unit with IP54 enclosure: Supply, transport, installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine. condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc. The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRSbased data transmission. b) For 1 HP capacity Pump-motor set (As per direction of EIC) W.R.I D.D. Schedule of Rates 2021,ch. 12, item no.3

5

191266

38253.2

... More
Cable and Accessories: Supplying, fitting and fixings of UV rated Copper Cable laid inside HOPEconduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5 Mtrs (Minimum) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc W.R.I D.D. Schedule of Rates 2021,ch. 12, item no. 4

5

6757

1351.5

... More
Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:- iii) Open well sub mersible pump set IS 14220 for PWD with discharge of 6.5-7.14 Lps 18 mtr. total head with required quantity of flexible delivery pipe (15mtr.) clamp bend foot valv and all other assessories to complete connection of suction and delivery. Ref:WRDD/SOR/8/iii

5

177804

35560.93

... More
Supplying,Fitting Fixing & Installation of Iron Removing Filter Plant Capacity 1500 LPH IR Media Filter Working -Downilow Max Flow Rate -3m3/hr Working Pressure-1-3 kg/cm2 Size -14"X65" Make Pentair (BIS Standards & Including 1 Year Warranty)

5

226442

45288.4

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) 15mm dia

100

13944

139.44

... More
25 mm dia

100

22763

227.63

... More
50 mm dia

750

360217

480.29

... More
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) 80 mm dia

2525

2392387

947.48

... More
Supplying, fitting and fixing brass ferrule including connection with P.V.C. pipe of approved make upto 450 mm long with plumbing joint,brass over C.P. coupling at both ends, with cap and lining complete in all respect, including cutting trenches in all sorts of soil and filling up trenches as per direction of the Engineer-in-charge. 25 mm dia.

20

43500

2175.03

... More
Solvent Cement 250 Gm.

100

15493

154.93

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 1500 litre capacity

10

93437

9343.71

... More
Labour for punching hole in plastic water storage tank upto 50 mm dia

30

679

22.64

... More
Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L.

10

1144

114.41

... More
Supplying, fitting and fixing push cock of heavy quality and of approved make and brand. Cast iron 15 mm

100

23955

239.55

... More
Supply of G. I. pipes of TATA make including necessary sockets 32 mm dia. Medium quality

90

27459

305.1

... More
C.I. sluice valve with flanged ends drilled to as per I.S. 1358/62 and having all cast iron components as per I.S. 780/71 solid forged bronze inside screw spindle having ultimate tensile strength not less than 4.72 MT per sq. cm. Spindle nut valve and seat faces of hard wear resisting, manufactured from best quality gunmetal conforming to I.S. 780/71, painted black all over with asphalt base paint tested to 21 kg (hydraulic pressure) per sq. cm., valve opening to anticlockwise direction, fitted and fixed complete. 50mm

5

16428

3285.79

... More
80 mm dia

5

22983

4596.77

... More
Sluice valve chamber with C.I. heavy cover with locking arrangement, (weight not less than 25 kg) (size of chamber 450 mm X 600 mm inside upto 900 mm depth) 250 mm thick cement brick walls (6:1), 150 mm thick cement concrete (6:3:1) bed with stone chips, 20 mm thick cement plaster (6:1) for inside wall and 15 mm thick cement plaster (4:1) for outer walls including rounding corners.

5

62325

12465.03

... More
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 80 mm dia

5

33316

6663.35

... More
50 mm dia

5

13568

2713.72

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. Area of each tile upto 0.09 Sq.m Coloured decorative

49.9

44301

887.89

... More
Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. Area of each tile upto 0.09 Sq.m Coloured decorative

56.7

49937

880.74

... More
Construction of street stand post 150mm x 150mmx 1200mm size with 900mm x 900mm size platform with drain.

70

333704

4767.2

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL)

5

92430

18486.01



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.