Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Zilla Parishad - ZP Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date3 Jan 2024
Closing Date18 Jan 2024
Tender Amount₹ 2,30,352
Costs
EMD
₹ 4,600Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Installation Of Spot Drinking Water Point Near Lohapota Kabar Sthan
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ZPHD_635703_4Bid Award Id
ViewTender No
SGP/22/5THSFC/2023-24Tender Authority
Zilla Parishad ViewPurchaser Address
-Website
http://wbtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Brick work with 1st class bricks in cement mortar (1:6)
(i) In superstructure, ground floor
1.88
9440
5035
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
4.35
2887
664
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
(i) Pakur Variety
0.24
1377
5740.15
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.
(a) For works in foundation and upto roof of ground floor/upto 4 m II. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL
8.95
537
60
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
A. 25 mm to 30 mm shuttering without staging
0.74
150
205
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
7.59
182
24
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
13.98
1718
123
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per 100 sq.m.
6.99
237
34
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification.
In Ground floor: Two Coats
7.44
364
49
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (a) For depth upto 150 metre. 40 mm dia. boring etc
30.5
4514
148
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. 100 mm dia. boring etc. top enlargement
36.59
15587
426
Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. 40 mm dia.
1
124
124
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). PVC Pipes 40 mm dia.
12.2
2525
207
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). PVC Pipes 100 mm dia.
36.59
31979
874
Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications.PVC Pipes 40 mm dia.
18.3
5361
293
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). PVC Pipes 32 mm dia.
30.49
5152
169
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). Reducing Socket 100 mm X 40 mm
1
202
202
Supply of G. I. pipes of TATA make including necessary sockets. (i) Medium quality 100 mm dia.
0.3
249
830
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately). For Exposed Work of 25 mm dia.
5
885
177
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 1000 litre capacity
1
5128
5128
Labour for hoisting plastic water storage tank.
(i) Upto 1500 litre capacity
1
96
96
Labour for punching hole in plastic water storage tank upto 50 mm dia.
1
19
19
Supplying, fitting and fixing alloy iron with brass spindle bib cock / stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. 15 mm dia.
4
676
169
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required. For 4 Hours
0.5
3769
7538
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
1
1231
1231
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.
I) For structural members of specified sections weighing less than 22.5 Kg./m 50 mm X 50 mm X 5 mm
146.53
10638
72.6
Solour Module: Supply, Transport, Installation and Commissioning of MNRE / IEC approved Solar Module of multi Crystaline cell with min efficiency of 15% & fill factor more than 70%, laminated between sheet of eethylene vinyl acetate (EVA) and high transmissivity 3.2 mm tempered glass, framed in anodised Aluminium frame. The power output of individual PV modules used in the PV array, under STC, should be minimum of 300 watt peak, with adequate provision for measurement tolerances. Modules supplied with the SPV system should have certificate as per IEC 61215specification or equivalent National or International standards, Modules must quality to IEC 61730 part-I and part-2 for safety qualification testing and Salt Mist Corrosion Testing as per IEC 61701 / IS 61701 and having warrenty for out put wattage , which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied for 1 HP Off grid Solar Water Pumping System
1300
43589
33.53
Power Conditioning unit including MPPT, data logger and IP-54 enclosure; Supply, transport, installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683 - Efficiency measurement and IEC 600682 - Environment Standard, safety standard suitable for I phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under Current, Over voltage, Under voltage, shot circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a dry run should be possible during normal sunshine condition. Inverter Should have option to auto start for any short trip off due to low light / cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar Panel DC voltage, inverter IGBT temperature, output AC voltage, output frequency, Pump flow (direct or calculated method), irradiation etc. The system should be capable to store the data at a set interval and transfer it in a pendrive through USB port. It should also monitor and save total run time, total water pumped etc. The controller must have AC-DC change over switch of current 25 Amp (Test certificate of VFD IEC and CE certificate should be submitted at the time of delivery) as per direction of EIC. For 1 HP Capacity Submersible Motor Set.
1
51750
51750
Supply and instalation of 80 mm bore well 1 HP / 0.75 KW Submesible pump Single Phase 220 volt along with necessary accessories complete set suitable for solar operation including loading unloading transportation etc asper direction of EIC
1
16000
16000
Eathing with 50mm dia. GI pipe 3.64 mm thick x 3.040 Mts long and 4 SWG GI (Hot Dip) wire (4 Mts long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the groundlevel as below.
1
1570
1570
Lighting protection (Pole mounted): Lightining protection with 3" x 1.5" G.I. pipe of 4 mts. Height with base flange in proper R.C.C. foundation and S & F Lightining Conductor Air Terminal made of 20 mm dia 100 mm long GI pipe (ISI medium) having five discharge points of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 standard GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base palte at bottom including necessary holes etc. Earthing with 65 mm dia GI pipe (medium) 3.0 Mtr long and 1 X 19/10 standard GI (Hot Dip) wire (4 mtr. long) 20 mm dia X 125 mm long galvanised bolt, double nuts, double washer including socking at both ends of standard GI (Hot Dip) wire by crimping socket / thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mtr. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts
1
7080
7080
Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750 x 37 mm. thick made with RCC 1:1½:3 with pakur variety stone chips reinforced with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts & bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750 mm. is of section 100 x 13 mm. and 1.90 metre above GL & 0.75 metre below GL including digging hole, repacking the same with cement concrete 1:3:6 with jhama khoa or with local stone chips etc. complete including painting two coats on both faces lettering sign marks etc. as per direction of the Engineer-in-Charge. (The rate is inclusive of cost of reinforcement, concrete, shuttering, nuts & bolts, washer etc. complete.)
1
2230
2230