Zilla Parishad Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Zilla Parishad - ZP Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date11 Nov 2024
Closing Soon18 Nov 2024
Tender Amount₹ 3,46,169
Costs
EMD
₹ 6,923Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ZPHD_767942_3Tender No
WB/JAL/SADAR/A.G.P./04/2024-25 3rd callTender Authority
Zilla Parishad ViewPurchaser Address
-Website
http://http://jalpaigurizp.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. in foundation Base.
4.35
324
1409.4
Cement concrete (1:3:6) with 30mm size down graded shingles excluding shuttering, N.B. Variety.
a) 1:3:6 proportion In ground floor. In foundation Base.
0.68
3393
2290.28
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending
to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.
I. SAIL/TATA/RINL
(a) For works in foundation, basement and upto roof of ground floor/ upto 4m (i))Tor Steel/ Mild Steel
0.05
66502
3325.1
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).
(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
4.6
328
1508.8
25mm to 30mm thick Shuttering without staging in foundation.)
1.6
205
328
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS code with River Bazree
0.6
4745
2847
Brick work with 1st class bricks in cement mortar (1:4)
(a) In foundation and plinth
1.4
5172
7240.8
(b) In superstructure, ground floor
2
5395
10790
Filling in foundation or plinth by silver sand in layers not exceeding 150mm as directed & consolidating same by thorough saturation with water ramming complete incl. the cost of supply of sand.
Plinth Filling:-
0.9
753
678.55
25mm thick damp proof with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10mm nominal size.] & admixture of water proofing compound as per manufacturer’s specification followed by two coat of polymer based paint,(1st coat after 4 to 5 days of concrete laying & 2nd coat just before brick masonry work) as directed.
1.41
194
273.54
125 mm brick work with 1st Class Brick in Cement mortar (1:4).
1
674
674
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
(b) 15 mm thick plaster with cement mortar (1:4).
21
157
3297
(c) 10 mm thick plaster with cement mortar (1:4).
4.6
126
579.6
Neat cement punning about 1.5 mm thick in wall, dado, window, sills, floor, drain etc.
NOTE: Cement 0.152cu.m. per 100 Sq.M.
5
34
170
Artificial stone in floor, dado, staircase etc. With cement concrete (4:2:1) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and including application of cement slurry before flooring works, using cement @ 1.75 Kg/ Sq.M. all complete including all materials and labour. 3mm thick topping.
Using grey cement.
(ii) 25 mm Thick
1.3
269
349.7
M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S./W.I. flats & bars of windows, railing etc. Fitted and fixed with necessary screws and lugs in ground floor.
(i) Grill weighing upto 16 kg/sqm
0.22
10021
2204.62
ORIGINAL WORKS
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle,
channel sections conforming to IS: 226, IS: 808 & SP(6)- 1964 connected to one another with bracket,
gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite
shape and length, fabrication with necessary bolting,
metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and
brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost
of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and
plants and labour required for the work including all incidental charges such as electricity charges, labour
insurance charges etc.
I) For structural members of specified sections weighing less than 22.5 Kg./m
0.04
74571
2982.84
Supplying 1.50mm thick M.S sheet fitting & fixed one or both faces of MS/WI Gate etc, with paint, welding at not more than 150 mm apart complete in all respect as per design including cost of all labours and materials.
1.3
1304
1695.2
Colour washing with "ELLA" with a coat of white wash priming including cleaning and smoothening surface
thoroughly: Internal (all floors) (b) Two coats
33.6
21
731.47
Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smoothening surface by sand papering etc. Metal Surface
2.6
29
75.4
Painting with best quality synthetic enamel paint of approved make & brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:
(b) On steel or other metal surface:
With super gloss (hi-gloss)-
(iv) Two coats (with any shade except white)
2.6
79
205.4
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) – Multilayer
(b) 1000 litre capacity
1
5128
5128
Labour for hoisting plastic water storage tank. i) up to 1500 ltr capacity a) up to 1st storied from ground floor.
1
96
96
Labour for punching hole in plastic water storage tank upto 50 mm dia.
3
19
57
(a) Original Works
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.
(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia.
(ii) 100 mm dia. boring etc. top enlargement
41.7
426
17764.2
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS: 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbow, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted including cost of all materials, jointing materials, cutting pipes, making threads cutting trenches up to 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes
(Dia)
32 mm
24
250
6000
100 mm
39
1162
45318
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and
threaded to match with GI Pipes as per IS : 1239(Part - I).
(K) End Plug
100 mm dia
6
220
1320
Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications. (iv) 100 mm dia
6
1319
7914
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbow, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads fitting, fixing etc. complete in all respect including cost of all necessary fittings as required jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials. Payment for painting will be made separately) (a) For Exposed Work PVC Pipes (Dia) : 25 mm
30.5
177
5398.5
PTMT (Polytetra Bib Cock / Stop Cock (Prayag or equivalent)
(e) 15 mm
4
154
616
Supplying, fitting and fixing of Sand Filter - Manual as per IS:14606
Sand Filter10m³/hr-M Single
1
17192
17192
Connecting the equipment to the earth busbar incl. S&F GI wire of size bellow on wall /floor as required and making connection to the equipment with bolts, washers, cable lugs etc. as required and mending good damages.
No 4 SWG GI wire
20
19
385.2
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By ISI-Medium GI pipe
1
1464
1464.83
Supplying 1 m × 0.6 m × 24 swg MS board containing list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house
1
1000
1000
Supply of 1 HP water fill stainless steel AC solar submersible pump motor set complete having suitable discharge as per yield test of well. Submersible cable of 30 mtr 3 core 2.5 sq. mm that cable (Finolex) with MOC bar chart (Kriloskar/Amrut Make Pump) (Rate to be fixed as per separate quotation excl.)
1
22000
22000
Supply, transport, installation and commissioning of Solar PV installation for water pumping system with fixed structure consisting of solar panels framed in anodized aluminium frame mounted on stable hot dipped galvanized (with 80 micron thickness) mild steel structure of sufficient strength which can withstand load of modules and high wind velocities upto 150 Km/hr, having RCC foundation designed against all possible loads (Dead, Live and imposed load). Modules supplied with the SPV system should have certificate as per IEC 61215 specification or equivalent National or International standards and must be interconnected with 4/6 sq.mm cables routed in PVC conduits properly fitted along the G.I. structure to provide a good aesthetic view. Modules must qualify to IEC 61730 part I and part II for safety qualification testing. The power output of individual PV modules used in the PV array, under STC, should be a minimum of 250 Watts peak, with adequate provision for measurement tolerances. Solar cells should be crystalline silicon cell with min. efficiency of 14% and fill factor more than 70%, should be laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2mm tempered glass including appropriate DC to AC inverter and power controlling unit (protected with IP65 class enclosure) with MPPT technology to run at low sunshine and minimum 5 hours a day run with all necessary accessories suitable for solar + grid operation and including all protections of AC induction motor pump. There should be a display of all measurable parameters including storing of data at a set interval and transfer it in a pen drive through USB port. There should also be provision of interfacing GPRS based data transmission. (The rate is inclusive of manufacturer's warranty and comprehensive maintenance
975
116
113100
Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tube well housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tube well and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants) b) 30 cubic metre per hour capacity electro motor pumping set.(i) Length of pump assembly not exceeding 18 metre length
1
617
617
Providing Sign Board /Display Board size 0.75 m x 0.50 m etc. at worksite including all complete.
1
1000
1000
Add GST @ 18%
1
52282
52282.57
Add Cess @ 1%
1
3427
3427.41
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%