Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Zilla Parishad Tender
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date22 Dec 2023
Closing Date6 Jan 2024
Tender Amount₹ 3,49,852
Costs
EMD
₹ 6,997Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Solar Mini High Mast Street Light
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_ZPHD_628996_2Bid Award Id
ViewTender No
NIT NO_E_15_2023_24 SL_1Tender Authority
Zilla Parishad ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approved stout props with wooden planks/ply wood/steel sheetplate with required bracing for any kind of plain orreinforced concrete works in all sorts of minor structure including
culvert, box culvert, cross-drain etc. The rate is inclusive of fitting, fixing and striking out after completion of
work as per specification and direction.
13.79
3369
244.32
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction. for works in foundation,basement and upto roof of ground floor / upto 4.0m. i. Tor steel / Mild steel ( TATA/ SAIL/RINL
0.2
14565
71752.32
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. River bazree.
4.6
25920
5634.83
Supply of 9 m high mast shaft suitable for wind speed as per IS 875 Part-3 with raising lowering system comprising , head frame ,luminaries carriage suitable to install 6 No luminaries in symmetrical arrangement , double drum winch , 6mm diameter SS wire rope. Trailing cable, connector, manual handle junction box, lightening finial etc as required. junction box, lightening finial etc as required. Diameter 420mm , Top diameter 180mm, Pole type Octagonal with galvanizing and corrosion Resistance, Bottom plate 540 x 540 x 20 mm Baseplate 540 mm dia, baseplate thickness- 25 mm. hole dia- 26 mm, foundation bolt size 24 mm dia Bolt length 850 mm, No of hole 12 nos. Foundation bolt 12 nos. Wire rope 6mm SS 304 grade.
1
79850
79850.6
Erection of 9 m high mast with all acc with the help of suitable equipments or with the help of modern engineering practices
1
25027
25027.8
Supply & Installation of indigenous modules shall be used in the project. SPV module aggregate capacity 1000 Wp (250 Wp X 4 Nos.) at 16.4 +_ 0.2 Volt under STC. Module Voc at least minimum of 21V. Only indigenous modules (Make in India) of reputed brand IEC Tested shall only be used in the project. C. Latest edition of IEC 61215 edition II / IS 14286 for Crystalline and shall be certified by MNRE authorized test center . PV modules must quality to IEC 61730 Part 1- requirements for construction & Part 2 – requirements for testing, for safety qualification.
1
57206
57206.4
Li Ferro Phosphate batteries of capacity 12.8 Volt, 12.8V, 120 Ah x 4 nos. Battery shall be Lithium Ferro phosphate (LiFePo4) with maximum Depth of Discharge 90%, the batteries should conform to the latest BIS /International standards, copy of the same relevant test certificate for the battery should be furnished. The battery should be tested by authorized MNRE test center. The battery shall be of LiFePo4 storage batteries as per MNRE with control electronics, BMS, inter-connecting wires/cables properly sealed.
4
52391
13097.88
White Light Emitting Diode (W-LED) 4*60 Watt( LED +Driver) Using LEDs which emits ultraviolet light will not be Permitted Only Nichia/ Osram/ Philips Lumileds/ Cree/ Seoul/ Everlite /eqivalent make LED’s shall be used for light.The light source will be of white LED type The color temperature of white LEDs used in the system should be in the range of 5500 degree K – 6500 degree K. The LED of make Nichia/Osram/Philips Lumileds/Cree/Seoul/ Everlite having LM 80 test report shall only be used. All LED in circuit must be connected in series only. It must incorporate fail short mechanism in all LEDs. The LEDs used in the luminary should have life time more than 50,000 hrs.
4
42904
10726.2
MPPT charge controller to maximize energy drawn from the Solar PV array. The MPPT charger shall be microcontroller based. The MPPT should have four stage charging facilities i.e Bulk, Absorption, Float and Equalization. The auto equalization facilities for every (30+_3 days) and provision to verify it during testing.
4
18115
4528.84
Two vented metallic box of 20 SWG thick made of pre coated galvanized ms sheet with 60 microns thickness for housing the storage battery outdoors should be provided with proper lock and key. The boxes should be inscribed with JREDA written on at least two faces. The size of box should be as per battery size (including vent plug/level indicator) providing minimum clearance of 25 mm on all sides. The battery box is to be properly rest/mounted on pole at 03 meters of height from ground level.
4
21452
5363.1
Supplying and erection of Earthing station with 50 mm dia. GI pipes 3.65 mm thick, 3M long and 1no. 4 SWG G.I wire 4 M long, 13mm dia, 80 mm long G.I bolt double washers, nuts, S&F 15 mm dia G.I pipe protection , to be field with bitumen, partly under ground and partly above above ground level driven to an avarage depth 3.65 m below the ground level including excavation of soil
2
3263
1631.57