Zilla Parishad Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Zilla Parishad - ZP Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date10 Feb 2025
Closing Soon24 Feb 2025
Tender Amount₹ 9,87,694 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of single storied AWC at various locations in the district of Malda
Construction of single storied AWC at Sibrampur Jabar, Mouza- Baharal Plot No.269. Khatian No.l, JI No.l 17 at Baharal GP Under Ratua-1 Dev. Block, Malda.(AWC code-19332220407)
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powered earth or local sand, as per direction of Engineer-in-Charge.

24.81

322

7988.82

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

46.31

24

1111.44

... More
Cement Concrete with graded stone ballast (40 mm size) excluding shuttering etc. as per direction of Engineer-in-In 6:3:1 proportion.charge, complete. In 6:3:1 proportion.

5.94

4246

25221.24

... More
Ordinary Cement Concrete ( Mix 3:1.5:1) with graded stone Chips 20 mm size excluding shuttering & reinforcement, if any as per IS 456-2000. Using Stone material of Rajmahal variety.

22.65

5086

115197.9

... More
Hire and Labour Charges for shuttering with centering and necessary staging up to 4 m using approved stout props and thick hard wood planks of approved thickness with required bracings for concrete slabs, beams, columns, lintels, curved or straight including fitting, fixing and striking out after completion of works. Using 25 mm to 30 mm thick wooden shuttering as per direction of EIC, complete. (A) 25 mm to 30 mm shuttering without staging in foundation

15.52

205

3181.6

... More
(B) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.

183.04

328

60037.12

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. of .Engieer-in-Charge.

2.04

62759

128028.36

... More
Brick work with 1st class bricks in cement mortar (6:1) in Foundation and Plinth

3.91

4919

19233.29

... More
Brick work with 1st class bricks in cement mortar (6:1) in Superstructure.

16.98

5142

87311.16

... More
125 mm thick Brick work with 1st class brick in Cement Mortar (4:1). In Ground Floor

28.32

676

19144.32

... More
Plaster ( to wall, floor , ceiling etc. ) with sand cement mortar including Rounding off or chamfering corners as directed and racking out joints or roughening of concrete surface, including threading nosing and drip Course where necessary.

209.59

163

34163.17

... More
B) 15 mm thick plaster in sand cement morter (1:6)

119.51

142

16970.42

... More
c) 10 mm thick plaster in sand cement morter (1:6)

72.33

127

9185.91

... More
Artificial stone in floor, dado, Stair case etc. with cement concrete ( 4:2:1) with stone chips, laid in panels as directed with topping made with ordinary or white cement ( as necessary ) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and including application of cement slurry before floring works using cement @ 1.75 kg. per sqm. all complete including all materials and labour. 3 mm thick topping ( high polishing grinding on this item is not permitted with ordinary cement)./ 25 mm thick

49.42

251

12404.42

... More
Neat Cement punning (about 1.50 mm thick) on wall, dado.

60.83

34

2068.22

... More
Wood work in door & window frame fitted & fixed complete including a protective of painting at the contact surface of the frame (i) Other Local Wood.

0.42

36302

15246.84

... More
Panel shutter of door and window as per design (each panel consisting of Single plank with out joint) including fitting and fixing the same in position but excluding the cost of hinges and other fittings. (ii) 35 mm thick shutters with 19mm thick panel of size 30 to 45 cm (c) Other Local Wood.

12.89

1601

20636.89

... More
Supplying, Fitting & Fixing Factory made P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm, PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15 mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm long M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer‟s specification and direction of Engineer-in-Charge.

4.95

305

1509.75

... More
Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge. In ground floor

1.44

1943

2797.92

... More
M.S. or W. I. ornamental grill of approved design joints continuously welded with M.S., W.I. flats and bars for windows,railing etc fitted & fixed with necessary screws and lugs i ) Grill weighing above 16 kg./ Sqm.

2.53

9827

24862.31

... More
Supplying , fitting and fixing M.S. Clamp for fixing door and window frame made of flat bend bar ,end bifurcated , fixed in cement concrete with stone chips (1:2:4) fitted and fixed complete as per direction (cost of cement concrete will be paid separately ). ii ) 40 mm x 6mm, 200 mm.length.

46

25

1150

... More
Iron but hinges of approved quality fitted & fixed with steel screws with ISI mark in position, complete. 100 mm. x 75mm. x 3.50 mm size

37

66

2442

... More
Anodised aluminium barrel tower /Socket bolt (Full Curved )of approved quality manufactured from extruded section confirming to I.S. 204/74 fitted and fixed with cadmium plated screw 300 mm. long x 10 mm.dia bolt

20

99

1980

... More
Anodised aluminium D-type handle of approved quality manufactured from extruded Section conforming to I. S.Specification (I.S.230/72) fitted and fixed complete with continuous plate base ( Hexagonal /rounded) a) 150 mm grip X 10 mm dia rod. For Door

6

97

582

... More
Iron Hasp Bolt of approved quality fitted & fixed complete (Oxidised) with 16 mm dia rod with centre bolt and round fitting. I) 250 mm long.

3

159

477

... More
Supplying anodised aluminium catch hook with eye fitted and fixed to shutter and chowkat complete of best quality. /150 mm. long a )150 mm. long

34

37

1258

... More
Supplying fitting & fixing UPVC pipes (A Type ) & fittings conforming to IS 13592-1992 with necessary clamps nails including making holes in walls etc. and cutting trenches in any soil through masonry concrete structure etc. if necessary and mending good damages including jointing with jointing materials ( Spun yarn , valamoid , bitumen IM seal etc. ) complete A) ( i ) Single Socketed 3 meter Length i) 110 mm.dia pipe

10

251

2510

... More
ii) UPVC fitting , 110 mm.dia Shoe

3

111

333

... More
iii) UPVC fitting ,Bend 110 mm.dia

3

160

480

... More
Priming one coat on steel or other metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surfaces by sand papering etc. i) On Steel Surface

16.17

29

468.93

... More
Priming one coat on timber, plastered with synthetic enamel / oil bound primer of approved quality including smoothening surfaces by sand papering etc. i) On Wooden Surface

41.97

38

1594.86

... More
Painting with best quality Synthetic Enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc on the surface if necessary. A) On timber or plastered surface with Super Gloss (Hi-gloss), Two coats (with any shade except white).

41.97

81

3399.57

... More
b) On steel or other metalled surface with Super Gloss (Hi-gloss), Two coats (with any shade except white).

16.17

79

1277.43

... More
Applying decorative cement based paint of approved quality including cleaning the surface including scraping the same thorougly ( plastered or concrete surface ) as per manufacturer's specification.

340.6

49

16689.4

... More
Construction of septic tank of different capacities as per approved drawing with Ist class brick work in cement mortar (4:1) including two 560 mm dia RCC manhole cover of approved make supplied, fitted and fixed in the top slab with necessary fittings, 19 mm thick cement plaster (4:1) with neat cement finish to the internal surfaces and 12 mm thick cement plaster (4:1) to outside wall upto 200 mm below GL floor finished with 25 mm hick grey artificial stone including supplying, fittings and fixing all necessary specials, fittings, SW tees, CI foot rest etc. including excavating earth in all sorts of soil, shoring, bailing and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tank with earth, removing spoils, filling up the chabmer with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring to be done with admixture of water proofing compound @ 5% by weight of cement, complete in all respect as per directionof Engineer-in-charge / TATA / SAIL/ RINL. a ) 10 Users

1

33876

33876

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid ( Black )– Multilayer a ) 500 litre capacity

1

2584

2584

... More
Labour for hoisting P.V.C. water storage tank . i ) Upto 1500 litre capacity a ) Upto Ist storey from G.L

1

96

96

... More
Labour for punching hole in P.V.C. water storage tank upto 50 mm. dia.

3

19

57

... More
Supplying , fitting and fixing Bib Cock or Stop Cock i ) Polythene Bib Cock with plastic inlet quality ( EMCO / ATLAS or equivalent ) 15 mm

10

89

890

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) A ) For Exposed work a) 15 mm dia

20

101

2020

... More
b) 25 mm dia

15

177

2655

... More
c) 32 mm dia

10.98

236

2591.28

... More
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing). (i) 530 mm X 410 mm

1

1522

1522

... More
Supplying,fitting and fixing cast iron 'P' or 'S' trap conformimg to I.S. 3989 / 1970 and 1729 / 1964 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). (A) 'P' Trap /100 mm

1

948

948

... More
Supplying , fitting and fixing check valve ( vertical ) G.M. tested to 21 kg. per sq.cm.b) 40 mm dia

1

848

848

... More
Supplying fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg. per sqm. ( for water line only ) A) 25 mm dia

2

778

1556

... More
B) 20 mm dia

1

604

604

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soil with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (6:1) band all around and cement brick work (6:1) upto 0.90 metre from top with 19 mm thick cement plastering (4:1) to inside face upto the depth of cement brick work, 12 mm thick cement plaster (4:1) on outer face from top of the wall upto GL and 6 mm thick cement plaster (4:1) on top of the RCC cover slab including filling bottom 1.00 metre of inside of the well with brick metal ( 50 mm to 63 mm size) including RCC cover slab of designed thickness with cement Concrete (4:2:1) with stone chips with necessary reinforcement and shuttering including one 560 mm dia RCC manhole cover of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making necessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the excess eatth from the premises as per direction complete in all respect with all costs of labour & materials.With 250 mm. thick dry brick work and 250 mm. thick cement brick work (6:1) and 1.00 metre inside dia

1

15346

15346

... More
Construction of Inspect Pit of inside measurement 600 mm X 600 mm X upto 600 mm (depth) with 250 mm thick at 1st class brick work in cement mortar (6:1) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (6:3:1) with jhama khoa over a layer of jhama brick flat soling, 12 mm thick (4:1) cement plaster to insidewalls and out-side walls upto GL and 20 mm thick (4:1) plaster to bottom of the pit, providing necessary invert with cement concrete (4:2:1) with jhama chips as per direction, neat cement finishing to entire internal surfaces, top of the pit cover with 100 mm thick RCC slab (4:2:1) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (4:1) in all external surface of the slab & ne 560 mm dia RCC manhole cover of approved makes supplied fitted & fixed in the slab with necessary fitings, necessary earth work in excavation in all sorts of soil, filling sides of pit with earth and removing spoils after work complete in all respect. with pakur variety / TATA/SAIL/RINL

1

6674

6674

... More
Labour for boring tube will of required dia by water jet System through any type of soil strata including hire & labour charges for boring pipe , scaffolding , tools & plants as necessary and taking out them and lowering pipes ,strainers , blind pipe etc. & filling and fixing the same complete including bucket washing and other incidental works in this connection . The Tube Well should have an maximum 50 mm. gap in between the out side of the tube well and the bore. A) For the depth upto 150 m. For 50 mm. dia Tube-well with top enlargement of 100 mm. dia i) 100 mm.dia boring

30

426

12780

... More
ii) 50 mm. dia boring

40

287

11480

... More
Supply of PVC pipes and fittings Schedule 80 ( medium duty ) conforming to ASTMD-1785 and threaded to match with GI Pipes as per IS : 1239 ( Part-1 ) a) 100 mm dia

30.3

874

26482.2

... More
b) 50 mm dia

67.81

282

19122.42

... More
Supplying high density polythene stainer of approved make with adapter conforming to I.S. specification. 50 mm dia. a ) 50 mm dia

5.49

532

2920.68

... More
S/F/F steel cutter piece up to 450 mm long with socket. 50 mm dia.

1

189

189

... More
Supplying and installation of K.S.B. Sub-mersiable pump including connecting cable panel etc. all complete i ) 1.00 H.P. capacity ( Single phase )

1

14000

14000

... More
Supplying, fitting and fixing PVC insulated & sheathed Flexible three core flat cables of area 2.5 mm sqm as per stranded & bunched Type A of IS 5831/1984 & Sheathing to IS 8130/1984 for higher flexibility. are used to connect underwater as per ST I Type of IS 5831/1984.

43

90

3870

... More
Supplying , fitting and fixing Single Phasing VOLTAGE SENSING PREVENTER & AUTO START UNIT Submersible pump control panel (1/2 H.P. TO 2.0 H.P.range ) of L & T brand of an influential electronic circuit which keeps three stage worked electrical machines from single stage cut off, stage succession inversion and lopsided voltage.

1

4500

4500

... More
Supplying , fitting and fixing G.I. cap at top. i ) 100 mm dia.

1

139

139

... More
Supplying , fitting and fixing check valve ( vertical ) G.M. tested to 21 kg. per sq.cm. b) 40 mm dia

1

848

848

... More
Supply of PVC pipes and fittings Schedule 80 ( medium duty ) conforming to ASTMD-1785 and threaded to match with GI Pipes as per IS : 1239 ( Part-1 ) i) Reducing Socket 50 mm x 100 mm.

1

171

171

... More
Washing and developing tube well with air compressor pump and engine for 8 ( eight ) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with V-notch including hire and labour charges for all tools and plants and scaffolding as required complete in all respect.

0.25

7538

1884.5

... More
Packing the annular space between the outside of the tubewell pepes and strainers and bore with pea size washed gravels of approved quality having size from 2 mm. to 5 mm. the size approved by E.I.C. including cost of materials labours & equipment complete

1.26

2029

2556.54

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision)..

0.33

9356

3087.48

... More
Sub Total

-

-

-

... More
GST 18%

1

149173

149173.45

... More
Cess 1%

1

9779

9779.15



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.