Zilla Parishad Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Zilla Parishad - ZP Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date16 Jul 2024
Closing Date23 Jul 2024
Tender Amount₹ 2,25,442
Costs
EMD
₹ 5,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Drinking Water Facility At Puchiara
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ZPHD_715148_16Bid Award Id
ViewTender No
02/IPS/2024-2025 Dated-10/07/2024Tender Authority
Zilla Parishad ViewPurchaser Address
-Website
http://http://www.birbhumzp.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply fitting & fixing of pvc pipes …...…100mm as per LMR ex/c taxes
33
17836
540.5
80mm polythene strainer as per LMR ex/c taxes
6
2652
442
100mm polythene strainer as per LMR ex/c taxes
3
1830
610
32mm [Sch-80 ] hanging as per LMR ex/c taxes
36
6408
178
Excavetion of soil & Installing with civil Materials for foundation and charges (4 Piller each) including Labour charges: Earth work filling in foundation or plinth by fine sand in layers not exeeding 150mm as directed and consolidating the same by through saturation with water ramming complete including the cost of supply of sand , and filling by Ordinary Cement concrete(mix 1:1.5:3)with graded stone chips(20mm normal size) excluding shuttering and rainforcement, Hire and labour charges for shoring work, Rainforcement for rainforced concrete work in all sorts of structure including distribution bars,stirrups are in 8mm,binders,main bars 16mm, base bars 12mm etc as per in Degine. with as per LMR ex/c taxes
1
10000
10000
72/144cell Total 1.34KWp Solar Panel(ERTL & Flash Tested IEC-61215 Certified) with built-in 2/3 bypass Blocking Diode, IP68 rated split J-Box, MNRE approved grade SPV anel. Module efficiency 20%, Capacity: The power output of the module(s) should not be less than 335wp each. The operating voltage corresponding to the power utput(Vmp)per Module should be 35.0 volt. The Voc of the PV module under STC should be 44.0 Volts,lmp 9.4A, MSV1500VDC, Temparet ure Coefficient(Isc)0.05%/OC, Wind Load up to 2400Pa*, Warrenty 10years on met erials and workmanship and 25years on liner power performance (Brand: HR/ Canadian/Sova or Equivalent Company). There should be a name plate/Sticker fixed inside the Module (with bercode)which will provided:-) Name of the Manufacturer or Distinctive Logo, i)Model no, ii)Serial no, iv) Year of manufacturer. as per LMR ex/c taxes
4
38201
9550.35
Installation of 1 Hp Solar grade Submersible pump(Fully SS body), @30Mtr head, max shut off head 50Mtr, Star Cunection 3Phase 80 110 Volt AC/DC, Total warrenty for Motor Pump Controller minimum 5 years in written/Manufacturer /Supplyer warrenty. Water output is not less than 3000LPD@25Mtrs head. MAKE Any reputeted Indian company with MNRE Standered & BIS aproved Model. as per LMR ex/c taxes
1
14000
14000
Pump pou Controller for 1Hp Submersible Pump. Inbuilt MPPT controller,input De voltage should be 80-170 volt, out put Ac Voltage should be as per motor voltage configaretion. I/P max 10amps Max SCC, Over load Protection, Surge Protection, Reverse Polarity, Over/Under Voltage, Surge Portection (Class D), System Protection: Over Temperature, Degree Of Protection- IP-56, with inbuilt On/Off Switch. In Contrroler must provided with SPD, sort circuit protection with IP56 Grade Insulated box. with 2years manufacturer warrenty.with flat & autocut sensor. as per LMR ex/c taxes
1
12800
12800
Wirring meterial for Load output cunection, Electrical equipments & acsesaries inclushive installation, The electric Motor cable used shall be Tripple core PVC insulated copper cable of Size 2 50sqmm (35mtr)for Pump output(From Controller to Motor)Cables as per requirement (Havels/Polycab/Finolex/CRI) and Accessories as required, From SPV Module intercunection and to motor controller must be conect with 4.05qmm and above (DC copper Solar standerd Cable with MMC4 cunector with heat soldered(not punch type). The Earthing for Contraller and SPV Module must be with 1X45WG Copper rod/wire. as per LMR ex/c taxes
1
7000
7000
Gl structure (conforming 80micron conting) for water storage tank and SPV module Each base plate size 210 x 210 x 18mm with M24 x 915 x 4nos Anchore bolt, The Gl structure should be 3.5mtr hight(from Base plate to Water tank Floor)and can rest 2000ltr capacity water storage tank, with fixing of nessesary Gl relling & installation of SPV module top of structure 29 with 40degree angle and minimum 1500mm hight from tank floor on south side, the main piller section each 90mm X 90mm X 3.5mm thik Squre Tube, each and every pilar must cunected with Xcross type with rectangle pipe minimum thik 2.8mm, and as mentioned in deging. ALadder(into 2 section) must be attached with structure. The total structure weight not less than 200Kgs as per LMR ex/c taxes
220
21753
98.88
Construction of platform for stand post
2
1800
900
75 mm steel plug cutter.. S&P p-53, it-9/iii
1
403
403
80mm dia g.i clamp..LMR ex/c taxes
1
200
200
80mm x 100mm reducing socket….LMR ex/c taxes
1
321
321
gravels as per LMR ex/c taxes
15
600
40
carriage of tubewell and other material..LMR ex/c taxes
1
200
200
Pumping out water till sand free water obtained… LMR ex/c taxes
1
150
150
Supplying P.V.C. water storage tank, 2000 ltrs. with closed top s&P-p/it -37/6
1
10434
10434
Labour for hoisting plastic water storage tank...s&P-p/it -37/10
1
154
154
Plumbing works. Supply fitting & fixing of pvc pipes as required [ as per LMR ex/c taxes] + Labour cost as per S&P p-11, it-18.........15 mm dia [Rs. 52.5+26]
2
157
78.5
20 mm dia [Rs. 70+27]
15
1455
97
25 mm dia [Rs. 103+28]
10
1310
131
Polythene Bib Cock / Stop Cock with plastic inlet, p-6,it-7/f
2
178
89
Other G.I/PVC fittings required for installation or fitting & fixing of pipe line [Payment will bemade as per S&P sch. or LMR ex/c taxes]
1
500
500
Writing matter on wall and taking photography
1
250
250
Add GST @ 18.00%
1
34049
34049.07
Add Labour welfare cess @ 1.00 %
1
2232
2232.11