Zilla Parishad Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Zilla Parishad - ZP Tender
Civil And Construction
Eprocure
Opening Date21 Jan 2025
Closing Date4 Feb 2025
Tender Amount₹ 9,79,047
Costs
EMD
₹ 19,581Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_ZPHD_804135_3Tender No
3982/HS/APDZPTender Authority
Zilla Parishad ViewPurchaser Address
-Website
http://http://alipurduarzp.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.b) River Bazree:
0.26
4006
1041.56
... More
125 mm. thick brick work with lst class bricks in cement mortar (1:4) in ground
floor.
5.2
674
3504.8
... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.b) River Bazree:
2.35
4745
11150.75
... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a)For works in foundation, basement and upto roof of ground floor/upto 4 m(i) Tor steel/Mild Steel.II. .(JSW/JSPL/SHYAM/ SRMB/
BMASL/ ELECROSTEEL/SSL)
0.22
59102
13002.45
... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(f) 25 mm to 30 mm shuttering without staging in foundation
5.4
205
1107
... More
(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of
Engineer-In-Charge.
17.41
328
5710.48
... More
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification.(iii) Two coats. a) Normal Acrylic Emulsion
4
49
196
... More
(A)Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc including using of approved putty etc the surface,if necessary.(b)On steel or other metal surface:With super gloss (hi-gloss)(4)Two coats (with any shade except white)
30
79
2370
... More
(A)M.S or W.I. Ornament grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows,railing etc.fitted and fixed with necessary screws and lugs in ground floor.(add extra @1%for each addl.floor upto 4th floor and @1.25%for each addl.floor above 4th floor)(1)grill weighting above 10kg/sq.mtr and upto16kg/sq.mtr.the weight of grill per sq.m will be determined by taking the physical weight of fabricated grill and diving the same by covered area of the same.
0.12
10021
1202.52
... More
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering et
30
29
870
... More
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) ..................... all incidental chages (such as electricity, labour insurance) etc. complete. i) For roof truss works
0.45
74284
33427.8
... More
Supplying P.V.C water storage tank of approved quality with closed top with lid
(Black) - Multilayer 3000 liter capacity
1
15635
15635
... More
Labour for hoisting plastic water storage tank approved qualityb with closed top
with lid
4
154
616
... More
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary
accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,
reducing socket, reducing tee, short piece etc. fitted with holder bats clamps,
including cutting pipes, making threads, fitting, fixing etc. complete in all respect
including cost of all necessary fittings as required,jointing materials and two coats
of painting with approved paint in any position above ground. (Payment will be
made on the centre line measurements of total pipe line including all specials. No
separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work.15 mm dia. medium quality
8
192
1536
... More
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary
accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,
reducing socket, reducing tee, short piece etc. fitted with holder bats clamps,
including cutting pipes, making threads, fitting, fixing etc. complete in all respect
including cost of all necessary fittings as required,jointing materials and two coats
of painting with approved paint in any position above ground. (Payment will be
made on the centre line measurements of total pipe line including all specials. No
separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work. 40 mm dia. medium quality
15
415
6225
... More
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary
accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,
reducing socket, reducing tee, short piece etc. fitted with holder bats clamps,
including cutting pipes, making threads, fitting, fixing etc. complete in all respect
including cost of all necessary fittings as required,jointing materials and two coats
of painting with approved paint in any position above ground. (Payment will be
made on the centre line measurements of total pipe line including all specials. No
separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work. 25 mm dia. medium quality
10
305
3050
... More
Supply of G.I. plain equal elbow of approved brand and make elbow. 40mm dia.
10
89
890
... More
Supplying, fitting and fixing push cock of heavy quality and of approved make and
brand. (a) Cast iron
8
201
1608
... More
a) Supplying & fitting 2.5 Sq.m. 3 core PVC flat copper submersible cable (make :-
Finolexl Havels! Polycab/ Mescab)
50
126
6300
... More
b) Supply & fixing 25 mm dia G.I. pipe ( TAT A) cor calbe protection.
3
249
747
... More
c) Supply &fixing 25 mm dia elbow (ISI) for cable protection.
1
74
74
... More
d) Supply & fixing 25 mm dia union (ISI) for cable protection.
1
74
74
... More
Supply of Submersible pump controler single phase 2 HP 240 V, 50 HZ, CAT No.
SS97723 panle MR - G2 ( L& T make) as per direction of EIC.
1
5200
5200
... More
Lowering the submersible pump motor set 2 HP with 50 mm dia GI column pipe 450 ft. long & cable & refitting the plumbing line & electrical power line by own tools & takles as instruction of EIC
1
1449
1449
... More
Solar Moduie: Supply, transport, installation and commissionirgof MNRE(Ministry
of Renewable Energy, Govt of India)/IEC approved Solar Module of multicrystaline
cell with min efficiency of 15% and fill factor more than 70%, laminated between
sheet of -EthyleneVinyl Acetate (EVA)md higt rmsmissivity 3.2mm tempered
Igtass, flmed in anodizec aluminium frame .The power output of individual PV
I modules used in the PVmay, under STC, should be a minimum of 300 Watt 1 peak, with adequateprovision for me6urement tolerilces Modules supplied with the SPV system should have certificate a ftr IEC61215 specification or equivalent
INationat or Intemational standards Modules must qualify to IEC61 730 part I and
I part II for safety qualification testing md Salt Mist Comosror Testinguper ItEC61701nS 1701.and having waranty for outpul wattage,which should not be
lless than 90% at the end of 10 years and 80% at the end of 25 years Necessary
jcertificate also to be supplied a) For 2 HP Off-grid SolarWater Pumping system
I (with Surface pump-motor set - 2400WP with 300 WP SPV Panel
4800
33
160944
... More
Module Mounting Structure or 211P, 3HPadSHP Solar Wate Pumping System): Suppiy, trdspofr , installationof weather proo mmualtrackiag structu.e made of
MS chamels,angles anr pipesetc. duI) IS msked cha,nels md mgle(ls8o8) to hold SP
Module with MS hearry duty pipes not less than OD125mm as pe IS1239 md
platesof 15226 Structure like Cmopy supported witl a RCC columnis to beinstalled to limit lild requirement with i height of placement of poel ior free human
movement &( natural air cooling will be happening to Bet the maximun eificiency
Aom the modules.Tlls structure to be desIgned considering all the possibl loads on the solar paels and on tbe structure itself includrnl wind load uth boicwild velocity
150km,4rr. The steel smcturi of suitable sIze is to be protected with minrmum 80
microt galvmisation and provided wth dual axis mmual trackinl arangeme.t three
rimes in a Cay od semonal tilting ue to br provided to face rhe sun optimally The
weight of the Moduie Mounting Structui having 4 Module structure of 320/325+p
poels shouid not b less than 1 45K9, 6 Module st ucrure of 20/325wp panels shoul
not ile less thm 191Kg and 8 Module structure of 300wp panel should aot be less
thm 263Kg
100
120
12000
... More
Foundation of Module Mounting Structure: Suitabie and stablr Reintbrced Cement Concrete loundation for dual urs mmua tracking SPV Moduie structure 6 per approved drawing. For 8 module stnrchrre havins maximrrm canAcrto
of 2400 Wp
2
10000
20000
... More
Power conditioning unit including MPPT, Data logger and IIP5,1 enclosure: Supply , trmsport , installation and I
commissioning of [P 54 proiected enclosured Inverter Unil
qualifoing IEC 616&3-Efficief,cy measurement and rEC 600682- Environment Stedard , safety standdd suitable for 3 Phase A C.motor, 1GBT bred high voltage switching inverter with MPPT technology,to take cae of the varialion of Sunlight ed will be suitably mounted inside the metal enclosure Inveftei should have
protection against Dry run, Overcunent. Undercunerl Overuoltage, Underuoltage,
Shon circuit etc. Sys&m should be able to run at low sunshine md minimum 7 to 8
hours a day run should be possible during nomal sunshine condition. Inve.ter
should have option to auto start for any short trIP off due to low light/ cloudy
situation exceptfor dry run. Inverter should be provided with a display to show
the various parameter by the user such oVoitage, Curent, Solar panel DC voltage,
Invefter 1GBT temperature, Out put AC voltage, Outpul tiequency, Pump flow
(direct or calculated method), Iradiation etc. The system should be capable to
store the data at a sel tnterval md transfer it in a pendrive through USB pon it
should also monitor and save total tun time, total water pumped etc. Ihere
should be provision for interfacins GPRS bced data
2
18700
37400
... More
Supplying, fitting md fixings of UV rated Copper Cable lair inside HDPE conduit @d other accessories o per following with necessary connection with the Sola PV Module, MPPT etc. L 4.0 Sqmm single core multi studs- 10 Mtrs (Minimum) 11 6 0 Sqmm single core multi studs-5 Mtrs (Minimum) III. Lugs, HDPE Pipe, Flexible
Pipe, Saddle, Cabletie etc a)For 2 HP oer structure
1
2070
2070
... More
Lightring protection (Pole mounted): Lightning protection with 3. Xl.5' G.lpip€ of4 mts height with boe flmge in proper RCC foundation ed S & F LightninC Conductor Air Teminal made of 20 mm dia 1000mm long GI pipc (ISI Medium) having five dischage prongs of 4SWG Gl (Hot Dip) wre a1 top duly soldered Mth 7/16
stranded Gl (Hol Dip) wire and 85 mm dia 6 mm thick GI bme plate at bottom
Inci. necessary hoies etc. Earthing Mth 65 mm dia GI pipe (Medium) 3.0 Mts. long
md 1 x 19/10 standed Gl (Hot Dip) wire (.1 Mts. long), 20 mm dia x 125 mm long
galvmized bolt. double nuts, double wchem including socketing at both ends ol
stranded Gl (Hot Dip) wire by crimping sockets/ thimbles and S& 1 40 mm dIa GI
pipe (ISI-Medium) protection (3 Mts. long)to be 611ed uith bitumen partly ulder
the ground level and partly above ground level to m average depth o{ 3.65 Mts.
(Provision of on€ iightning protection for each stnrctr.e) For 2HP per structure
1
7080
7080
... More
MS KIOSK of size ..............controlled and other accessories, complete wth steel door including necessary fittings and locking mangemnets, etc. and ily other incidental chages a requi.ed to meeT the rcquirements of ihe speci+ied drawings md technical specitications, o per the direction ofthe Engirreer-In- chage.
1
5500
5500
... More
Supply of M.S.E R.W. Pipe duly ISI Certification maked. Both Ends Plarn lengh of Prpe shoull be o per 1 S Speci ficalon requirement of Ordering Aulhority IS
427012001 uith. Latest mendments thereof At,olowd Rdte of14BADMIP Proiect
of Conchhehnr Dirlrict
1
2804
2804
... More
Earthing wth 50 mm riia GI pipe 3.64 mm thick x 3.04 Mts. long md 1 x 4SWG Gl
(Flot Dip) wire (4 Mts. iong), 13 mm dia x 80 mm long GI bolts, double Euts,
double wmhers roci S & F 15 mm dia GI prpe protection (1 Mts long) to be filled
Mth brtumen panly undel the ground level and partly above ground lercl driven to
d average depth of3.65 Mts. below the ground level a beiow: (a) By ISI-Medium GI
pipe including excavation of soil lor iistallation of Earth Elecrode ad filling &
rmming and cornecting to individual sructure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dlp) MS flat on wall/floor with GI saddles 4 reqsrred
md connection to equipments rncl. drilling.holes, with boits. nuts, washers etc.
1
1980
1980
... More
Supply of Lay Flat hose .of 75 mm nominal size polyster reinforced lay flat house
(the house should has wall thickness 1.3 +- 0.3 mm working pressure 3.0 kg/ m2
& brusting pressure (9 kg/m2). The Lay flat hose shouid have a standard length of
100/200 m roll (Ref No Approved rate of SE (AI) Raiganj (AI) Circle
100
163
16300
... More
Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750
x 37 mm. thick made with RCC 1:1%:3 with pakur variety stone chips reinforced
with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts &
bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top
750 mm. is of section 100 x 13 mm. and 1.90 metre above GL & 0.75 metre below
GL including digging hole, repacking the same with cement concrete 1:3:6 with
jhama khoa or with local stone chips etc. complete including painting two coats
on both faces lettering sign marks etc. as per direction of the Engineer-in-Charge.
1
2230
2230
... More
Labour for punching hole in plastic water storage tankup to 50mm dia
4
19
76
... More
RIG BORE TUBE WELL WITH MARK II PUMP Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (a) For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 metre). (i) First 50 metre
50
1014
50700
... More
(ii) Next 50 metre
50
883
44150
... More
(iii) Next 50 metre
50
1055
52750
... More
2. Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge (a) 100 mm nominal dia (i) 6.0 mm wall thickness
12.2
1638
19983.6
... More
3.Supplying, fitting and fixing heavy type bell mouth reducing socket. (iii)100 mm X 150 mm
1
455
455
... More
Supplying M.S. male /female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per direction of Engineer - in Charge (i) 100 mm
2
2628
5256
... More
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
1
2235
2235
... More
Providing 200 mm centre guide. i) With Clamp
23
128
2944
... More
(A) Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of
of TATA make (heavy quality) as per standard specification, 5 mm thick. (i) 100 mm dia. (internal)
142
1045
148390
... More
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.
cu. m. 2029.00
Note: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water.complete.
4
2029
8116
... More
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete
4
417
1668
... More
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
2
7538
15076
... More
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
1
916
916
... More
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
1
1231
1231
... More
13. Supplying, fitting and fixing G.I. cap at top (ii) 150mm
1
139
139
... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80
(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats lamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint
in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work (i) 40mm dia.
100
283
28300
... More
ii). 15 mm dia
10
106
1060
... More
Supply & fixing & installation on CC muffing of feeder piller (2'x2.5'x1') box febricated by 14SWG MS sheet with angle for main switch starter as stated below with hinged door and locking arrangment as per direction of EIC a) 230/250V,15A,SPN SFU with re-wireable fuse(L&T) b) 230V,1.5HP, DOL Starter with A&V meter (L&T) c) Dener board-1set.
1
11560
11560
... More
supply & saying 1.1KV rgade 2x10 sqmm PVC/A AI cable in UG treanch as to GS with 1x6SWG GI wire.
35
367
12845
... More
Supply & fixing of compressive type cable gland as to GS for 2x10 PVC/A cable.
2
75
151.8
... More
Finishing the cable end by crimping method as to GS.
2
52
105.6
... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Lomg and 1x4 SWG GI (Hot Dip) wire (4 Mts. Lomh), 13 mm dia x 80 mm long GI bolts double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Nts. Long) to be filled with betumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe.
1
1650
1650
... More
Supply, Installation, tesing & lowering of 1.5 HP water filled submersible pump motor set complete having suitable discharge as per yeld of well. Submerisble cable of 30mtr 3 core 2.5 sqmm that cable (Finolex) with MOC ber chart (Crompon make Pump) and necessary control panel and starter as per manufacturar specifications.( Rate arrived after quatation which is enclosed)
1
25000
25000
... More
Add GST@18%
1
147867
147867.47
... More
Add CESS@1%
1
9693
9693.53
Evaluation Notes How It Works ?