West Bengal State Marketing Board Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
West Bengal State Marketing Board - WBSMB Tender
Civil And Construction
Building Construction
Eprocure
Opening Date13 Jun 2024
Closing Date10 Jul 2024
Tender Amount₹ 43,62,510
Costs
EMD
₹ 87,250Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBSMB_693217_1Bid Award Id
ViewTender No
WB/Pur.BZRMC/e-NIT-01/2024-25Tender Authority
West Bengal State Marketing Board ViewPurchaser Address
-Website
http://wbtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
(b) For additional depth beyond 1.5 m. and upto 3.00
m
26.51
11374
429
Earth work in filling in foundation trenches or plinth
with good earth, in layers not exceeding 150 mm.
including watering and ramming etc. layer by layer
complete. (Payment to be made on the basis of
measurement of finished quantity of work). (a) With earth obtained from excavation of foundation.
298.48
23143
77.54
Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. In Ground floor.(Pakur variety). (a) 6:3:1 proportion.
17.6
82768
4703
Ordinary Cement concrete [ Mix 3 : 1.5 : 1 ] with graded stone chips(20 mm.size) excluding shuttering and reinforcement, if any, in ground floor.as per Is Codes. a) Pakur Variety.
173.97
982032
5645
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. i) Foundation and Plinth.
370.73
134575
363
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. i) Ground Floor
734.75
266712
363
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (i) Tor steel/Mild steel. (a) For works in foundation, basement and upto roof of ground floor / upto 4m.
16.39
891261
54385
Brick work with 1st class bricks in cement mortar (6:1) . a) In Foundation and plinth.
41.64
198497
4767
Brick work with 1st class bricks in cement mortar (6:1) . b) In Super structure Ground floor
27.16
135543
4990
Brick work with 1st class bricks in cement mortar (6:1)
11.86
63130
5323
125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in ground floor including for using approved H.B netting in every third layer above in any floor. i) Ground Floor
72.59
50665
698
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) .(ii) With 4:1 cement mortar. 15 mm thick with cement mortar(External). Ground Floor.
451.1
66762
148
(ii) With 6:1 cement mortar. (b) 20 mm. thick plaster (Internal). Ground Floor
384.99
58517
152
Above 2nd Floor
57
9348
164
(ii) With 4:1 cement mortar. (c) 10 mm. thick plaster. Ground Floor
329.88
39915
121
Above 2nd Floor
19.38
2576
133
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.
348.77
11509
33
Artificial stone in floor, dado, staircase etc. with cement concrete (4:2:1) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and including application of cement slurry before flooring works,using cement @1.75 kg./sq.m. all complete including all materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted) with ordinary cement. Using grey cement. a) 35 mm. thick. Ground Floor
266.4
83649
314
(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive &waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
196
50373
257
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.
10.16
50598
4979.22
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive
(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cementmand colouring pigment to match with colour of tiles / epoxy
grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. A) Deep Colour & WhiteFloor Ground Floor.
13.55
22797
1682
(B) Wall With Sand Cement Morter (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sq.m & joint filling using white cement slurry @ 0.20 kg/Sq.m.(b) Area of each tile above 0.09 sq.m.ii) Other than Coloured decorative including white. Ground Floor.
37.54
26202
698
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
27.77
27881
1004
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. Ground Floor
0.58
5695
9888
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
3.15
4107
1304
Supplying fting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straitning if required, fixing lugs in cement concrete ( 4:2:1) with stone chips 19 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Flash butt welded windows and ventilators.(no shop priming will be allowed to facilitate inspection of workmanship).Without integrated grills.(b) Openable steel windows as per IS sizes with side hunge shutters and horizotal glazing bars, with or outhout fixed type ventolators ( the extra rate admissible for the openable portion only.)
3.6
7916
2199
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins
and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(i) 66mm x 90mm.
9.9
4920
497
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor. 32 mm thick
3.15
8703
2763
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible
bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.
2.52
10911
4330
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).
(e) Sal : Malayasian`
0.08
6121
75572
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm
wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or
similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other
fittings in ground floor.
5.04
11889
2359
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc.
15.12
438
29
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary .On Steel Surface.With super gloss (hi-gloss).(iv) Two coats (with any shade except white).
157.68
12456
79
Priming one coat on timber, plastered surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc.
18.14
689
38
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary .On timber surface.With super gloss (hi-gloss).(iv) Two coats (with any shade except white).
18.14
1469
81
Supplying, fitting and fixing M.S. clamp for fixing door and window frame made of flat bent bar, end bifurcated, fixed in cement concrete with stone chips (4:2:1) fitted and fixed complete as per direction. (a) 40mm. X 6mm, 250mm. Length.
16
464
29
Anodised aluminium barrel/ tower/ socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws. (ix) 300mm long x 10mm dia. bolt.
12
1188
99
Anodised aluminium Aldrop/Sliding bolts of approved quality manufactgured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (i) 300 mm x 16 mm dia.
2
462
231
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws.(v) 100 x 63 x 3.2 mm
8
576
72
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete.(a) With continuous plate base (hexagonal/round rod).(i)150 mm grip x 12 mm dia
6
666
111
(i) Door stopper (Brass)
(iii) steel body foot-door holder
2
234
117
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the Engg-in-charge. In ground floor
451.1
20344
45.1
Protective and decorative acrylic exterior emulsion paint of approved quality as per manufacturers specification and as per EIC to be applied over acrylic primer as required. The rate includes cost of materials, labour, scaffolding and all incidental charges but excluding the cost of primer. In ground floor( two coats). a) Normal Acrylic Emulsion. Ground Floor.
451.1
30223
67
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor). b) Two Coats. i) Water based interior grade Acrylic Primer.
404.36
12454
30.8
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
404.36
28305
70
Supplying,Fitting & Fixing UPVC pipes A- Type and fittings confirming to IS : 13592 - 1992 with all necessary clamps nails,including making holes in wall, Floor etc. cutting trenches in any soil through masonry concrete structures etc. if necessary and mending good damags including joining with jointing materials (Spun Yarn,Valamoid/Bitumen/M-Seal etc.)Complete.110 mm Dia.
58.8
14758
251
B) UPVC Fittings Bend 87.5 degree, 110mm dia
14
1960
140
Shoe, 110 mm dia
14
1554
111
Supplying fitting fixing fan hook for ceiling with 1 metre long 16 mm dia rod complete including mending damages.
60
6000
100
Total Amount of Sanitary and Plumbing
1
50000
50000
Total Amount of Electrification
1
50000
50000
Add GST @ 18%
18
658878
3660437.7
Add Labour Welafare Cess @ 1%
1
43193
4319316
Evaluation Notes How It Works ?