West Bengal State Marketing Board Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

West Bengal State Marketing Board - WBSMB Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date11 Dec 2024
Closing Date7 Jan 2025
Tender Amount₹ 1,98,16,734 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

445.85

77

34571.21

... More
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

419.44

521

218557.6

... More
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) (b) (i) With carried earth arranged by the contractor within a radius of 3 km. including cost of carried earth.

170.46

379

64744.12

... More
(c) Anti termite treatment to the top surface of the consolidated earth within plinth walls withchemicalemulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)

355.71

110

39128.1

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

1196.85

324

387779.4

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

934.37

24

22424.88

... More
Cement concrete with graded stone ballast (40 mm size) excluding shuttering ground floor and foundation with Proportion(6:3:1) (B) With N.B. Variety stone metal.

123.49

3575

441476.75

... More
Controlled Cement concrete with well graded stonechips (20mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete asper IS:456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as perdirection of Engineer-incharge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubicmeter of controlle concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 25 Grade (i) Pakur Varity

340.25

6620

2252706.79

... More
In 1st Floor.

1.18

6715

7924.57

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.

2561.78

328

840263.84

... More
1St Floor

13.5

346

4671

... More
Hire and labour charges for shuttering with centering and necessary staging 4m using approved stout props and thick hard wood planks of approved thickness with require bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, and striking out after completion of works ( up to roof of ground floor). (c)9 mm to 12 mm thick approved quality ply board shuttering in any concrete work (upto roof of ground floor)

390.49

363

141747.87

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. floor/upto 4 m Tor steel/Mild Steel (JSW/JSPL/SHYAM/ SRMB/ BMASL/ ELECROSTEEL/SSL)

51.84

58260

3020198.4

... More
1St Floor

0.19

58690

10857.65

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

135.74

4850

658339

... More
b) Superstructure Ground Floor

88.21

5073

447489.33

... More
In superstructure, 1st floor

8.27

5184

42845.76

... More
Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth

2.52

5103

12859.56

... More
125 mm. thick brick work with 1st classbricks in cement mortar (1:4) in ground floor.

205.27

666

136709.82

... More
125 mm thick brick work with 1st class bricks in cement morter (4:1) in ground floor

11.34

678

7688.52

... More
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]

862.94

1008

869843.52

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (2) With 1:6 Cement morter (a) 20 mm thick plaster

2335.22

157

366629.54

... More
1St Floor

33.06

161

5322.66

... More
(ii) With 1:4 cement mortar(c) 15 mm thick plaster, Ground floor

277.63

153

42477.39

... More
For Mumty Room

37.36

157

5865.52

... More
(ii) With 1:4 cement mortar (b) 10 mm thick plaster , ceiling

144.69

123

17796.87

... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

339.71

33

11210.43

... More
Supplying fitting and fixing 600 mm (+- 30 mm) diametre R.B.T (Reinforced Barbed Tape Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T stands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as C clips R.B.T clips etc.) .

80

408

32640

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white

75.9

1036

78632.4

... More
Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling]Red Variety(ii) 30 mm. thick

19.98

498

9950.04

... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-incharge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)

6.4

9077

58092.8

... More
(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required), For Stall..

136.92

257

35188.44

... More
Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receiveDistemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per manufacturer's specification andas per direction of the EIC. (In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer, Measurement takig vide item no.12-13

495.05

30

15247.54

... More
Applying decorative cement based paint of approved quality afterpreparing the surface including scraping the same thoroughly(plastered or concrete surface) as per manufacturer's specification.In Ground floor: (iii) Two coats.

508.49

49

24916.01

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (b) Two Coats, For Shed

1158.2

45

52234.82

... More
i) One Coat for Stall

470.1

31

14761.14

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat) a) Normal Acrylic Emulsion , For Shed..

1613.9

67

108131.3

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S.flats as collapsible bracings properly rivettedand washered including 38mm steel rollersincluding locking arrangements, fitted andfixed in position with lugs set in cementconcrete and including cutting necessaryholes, chasing etc. in walls, floors etc. andmaking good damages complete.

4.2

4351

18274.2

... More
(a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.

46.08

3270

150681.6

... More
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. (i) 66mm x 90mm

5.1

497

2534.7

... More
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor. (i) 32 mm thick

1.64

2763

4531.32

... More
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending gooddamagestomatchwith existingsurface completein allrespect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the and horizotal glazing bars]

1.8

2199

3958.2

... More
Supplying,Fitting & Fixing UPVC pipes A- Type and fittings confirming to IS : 13592 - 1992 with all necessary clamps nails,including making holes in wall, Floor etc. cutting trenches in any soil through masonry concrete structures etc. if necessary and mending good damags including joining with jointing materials (Spun Yarn,Valamoid/Bitumen/M-Seal etc.)Complete.A) UPVC Pipes (ii) 110 mm dia

224

251

56224

... More
© Bend 87.5 degree(ii) 110 mm dia

64

160

10240

... More
(d) Shoe (ii) 110 mm dia

48

111

5328

... More
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoot hening surfaces by sand papering etc. Rooling Shutter

114.05

29

3307.45

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) Ground floor

114.05

79

9009.95

... More
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. Ii) For roof truss works c) Span up to 12 Mtr

12

74284

891408

... More
M.S. structural works in columns, beams etc. with simple rolledstructural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.For structural members of specified sections weighing less than22.5 Kg./m MS Angla of size - 75mm x 75 mm x 6 mm

0.6

74571

44742.6

... More
Supplying , fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc.complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). In Roof:-With 0.5 mm thick sheet

29.1

896

26073.6

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.

0.49

10021

4910.29

... More
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

605.65

29

17563.85

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (iv) Two coats

608.71

79

48088.09

... More
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:-

924.6

896

828441.6

... More
Supplying, Fitting Corrugated Zinc Alluminium alloy coloured sheet ridging fitted with necessary bolts, Screws, washers etc complete. (225 mm end lapping) 300 mm lapping each way with 0.60 mm sheet. A) 300 mm lapping each way (a) With 0.60 mm sheet

138

520

71760

... More
Zinc Aluminium alloy Colour coated steel sheet vally gutter with perimeter not less than 750 mm with 225mm lap each way fitted & fixed with necessary bolts, nuts,screws, Etc complete. Vallygutter made of 0.63mm. Thick sheets (300mm in lapping)

276

621

171396

... More
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.(ii) 20 mm dia bolt. (c) 600 mm long

384

279

107136

... More
I.C.B Pavement

-

-

-

... More
Earth work in excavation of foundation trenches or drains in all sorts of soil ( including mixed soil but excluding laterite or sand stone ), including removing, spreading or stacking the spoils with in a lead of 75 m. as directed and including trimming the side of trenches, leveling, dressing the bottom, bailing out water etc. as required complete. (a) Depth of excavation not exceeding 1500 mm

244

119

29101.88

... More
Compacting original ground supporting subgrade Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Clause 305.3.4 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).

810

55

44955

... More
Water Bound Macadam Base Course Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density. (iii) Grading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm) Using manual means:

162

1444

234025.2

... More
Supplying and Laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks ( with concrete grade as specified as per Table 1 of IS 15658:2006) manufactured in steel mould clumped to a vibrating table by hydraulic pressure (as per cl. No. 6.30 of IRC:SP:63 (2018), from BIS licensee manufacturer, with spacer nib (Small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per CL NO. 3.26 of IS:15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per CL. NO. 3.3 of IS:15658) as per Table 2 of IS:15658 with flexural strength / breaking load as epr Annexure G of IS:15658, on the prepared base course of specified CBR as per Table 1 of IRC SP 63 (2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35 mm thick (grading of the bedding sand as per Clause 6.5.1 of IRC SP-63) and filling up the gaps in between paver blocks with joint filing sand (the grading of the joint filling sand will be as per Clause 6.5.2 of IRC SP63) and completing the edges with cut blocks as per CL. NO. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edge gap. 50 mm thick. Grey

810

751

608310

... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 for Rural Roads of MORD including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

50.4

104

5241.6

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches

125.98

24

3023.52

... More
Cement concrete with graded stone ballast (40 mm size) excluding shuttering ground floor and foundation with Proportion(6:3:1) (B) With N.B. Variety stone metal.

45.45

3575

162483.75

... More
Controlled Cement concrete with well graded stonechips (20mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete asper IS:456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as perdirection of Engineer-incharge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubicmeter of controlle concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 25 Grade (i) Pakur Varity

122.4

6298

770996.38

... More
Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approved stout props with wooden planks/ply wood/steel sheet plate with required bracing for any kind of plain or reinforced concrete works in all sorts of minor structure including culvert, box culvert, crossdrain etc. The rate is inclusive of fitting, fixing and striking out after completion of work as per specification and direction.(b) Where staging is not required.

360

214

77040

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. floor/upto 4 m Tor steel/Mild Steel (JSW/JSPL/SHYAM/ SRMB/ BMASL/ ELECROSTEEL/SSL)

0.15

58260

8739

... More
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes, 20 mm

125

143

17875

... More
Bituminous filler of approved type in expansion joints of dummy joints including finishing the top surface as directed.

0.32

46603

14679.95

... More
Electrical Work

-

-

-

... More
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required

41

185

7591.15

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required, 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC

396

74

29601

... More
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC

720

109

78660

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish(2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC), Average run 9 mtr

186

1220

226947.9

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC, On Board

11

87

961.4

... More
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles, 25 mm dia 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire

1116

90

101388.6

... More
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (All L&T make), 100AMP

1

8439

8439.85

... More
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required ( Alluminiuam). 4 bars,415 V, 200 A Dimension of Al. bars [85mm long] Dimension of Sheet Metal Box.300x150mm

1

3199

3199.3

... More
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+6 way

10

1382

13823

... More
Supplying and fixing 240V MCB Isolator on din rail of existing DBs and necessary connection. 40 Amp

29

362

10505.25

... More
Supplying and fixing 2 WayMCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment

19

310

5899.5

... More
Supplying and fixing 415 V MCB Isolator on din rail of existing DBs and necessary connection. Supplying and fixing 6-32 A 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection

16

184

2944

... More
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.

9

200

1800.9

... More
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.

9

271

2442.6

... More
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m.Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in- Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor

2

2533

5066.66

... More
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.

9

43

393.3

... More
Supply of 2 Core 4 Sq mm Alluminium XLPE /PVC Armoured cable for 16 A DP main switch to Out side DP Main Switch and Out Side DP Main Switch to Different Wall Bracket Light Point.

379

106

40174

... More
Laying of cable 2 core 4 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting

379

65

24843.45

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables of 2 core 4 sqmm

24

72

1738.8

... More
Finishing the end of 2 core 4 sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials

24

35

855.6

... More
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamp with bolts, nuts etc. including painting with anticorrosive paint

12

526

6320.4

... More
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite / Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. Supply & Fixing 240 V 16A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required

1

323

323.15

... More
Supply of 45 watt FREEDOM NEO LED streetlight made up of pressure die cast housing with toughened glass and high power LEDs with secondary optics with IP65 protection. External SPD can be ordered separately. Efficacy ≥ 110LPW. Model No.LSTS-45-CDL-M

12

5502

66033

... More
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.

12

928

11136.6

... More
Excavation of soil for installation of Earth Electrode and filling & ramming for soft Soil.

8

247

1978

... More
Earthing with 50mm dia G.I. pipe (TATA-M) 3.64mm thick * 3.04 Mtrs. Long and 1*4 WG wire (4 Mtr. Long) 13mm dia * 80mm long G.I. bolts double washers incl. S&F dia pipe protection (1Mtr long) to be filled with bitumen partly under the G.L. and partly above G.L. driven to an average depth of 3.65Mtrs .below the G.L. and restoring the surface duly remmed

4

1752

7010.4

... More
Extra treatment of soil by using salt and charcoal for pipe electrode as required.

4

610

2442.6

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe

4

1052

4209

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required

2

248

496.8

... More
Connecting the equipments to early busbar incl. S&F No. 8 SWG G.I. wire on wall /floor with stapels as per G.S.

40

10

414

... More
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required, 40 mm dia

36

282

10184.4

... More
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish, From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.

40

146

5842

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below, For 3 core, upto 16 sqmm

6

151

910.8

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials, 4 core16 sqmm cable

16

109

1748

... More
Supplying of one no 4 core 16 sqmm Alluminiuam armoured cable. Make : Havells/ Mascab/ Pollycab.

40

259

10360

... More
Supply of 40 watt TRIMLINE is a robust and high performance batten. This LED luminaire comprises of extruded channel in thermally conductive material. High translucent serrated milky white diffuser is used to get glare free and smooth light distribution. Efficacy : 100 lumen/watt Model No.CCS-100-40-40-SL-DP-NWH

23

990

22770

... More
Supply & Installation of Solar Standalone Street Light system with inbuilt AH LI FE PO4 battery, mentioned below. Includes LED street Light with in-built battery, SCC, SPV Panel, GI Tubular Pole. Luminaire Wattage 30 ; System Voltage 12 ; Lumen 4095 ; Solar Panel Wp 125 ; Battery Ah 12v/24 AH LIFEPO4 ; Battery should be placed in the Luminarie ; GI Tubular Pole above ground 6 M TUB Pole total pole length 7 mtr. Make approved by EIC

10

75402

754020

... More
Add SGST @ 9%

1

1488929

1488929.37

... More
Add CGST @ 9%

1

1488929

1488929.37

... More
Add 1% L.W Cess

1

195215

195215.18

... More
Service Connection (Payment will be made on rceipt of original document against expenditure)

1

100000

100000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.