West Bengal State Marketing Board Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

West Bengal State Marketing Board - WBSMB Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Dec 2024
Closing Date8 Jan 2025
Tender Amount₹ 1,64,25,696 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

193.2

753

145661.21

... More
Pre-constructional antitermite measures :-(b) Anti termite treatment to back filling of the masonry foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrates ( 1% concentration) with water by weight at the rate of 7.5 Litres per sq. m. of the vertical surface of the substructure for each side of the foundation.. The work shall be carried out as per specification described in 6.2.2. of code IS-6313 (part -II) 1981. (Mode of measurment will be vertical area treated.)

276

130

35880

... More
Anti-termite treatment to the outside of foundations with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1%concentration) with water by weight including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm. from the ground level by rodding with 12mm. dia. M.S. rod at 150mm.interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the back fill earth by directing the spray of the imulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 4.3.1.1 of code IS-6313 (Part-III) 1981.

98.5

72

7092

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

637.28

322

205204.16

... More
Supplying and laying Polythene Sheet (150gm/sq.m) over damp proof course or below flooring or roof terracing or in foundation trenches.

637.28

24

15294.72

... More
Cement concrete with graded stone ballast (40 mm size) excluding shuttering ground floor and foundation with Proportion(6:3:1) (B) With N.B. Variety

75.93

3485

264677.55

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety

168.78

6513

1099264.14

... More
b) Ground Floor

127.48

6513

830277.24

... More
c)1st floor

2.77

6606

18298.62

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.

1560.19

328

511742.32

... More
a) 1st Floor

31.8

346

11002.8

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. floor/upto 4 m Tor steel/Mild Steel (JSW/JSPL/SHYAM/ SRMB/ BMASL/ ELECROSTEEL/SSL) a)Ground Floor

40.7

58260

2371182

... More
a)1st Floor

0.38

58690

22302.2

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

47.28

4845

229071.6

... More
b) Superstructure

47.76

5068

242047.68

... More
c) 1st Floor

47.53

5179

246157.87

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

286.65

674

193202.1

... More
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).

60.35

203

12251.05

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]

-

-

-

... More
20 mm thick plaster 1:6 (internal) a) Ground Floor

1151.54

161

185397.94

... More
b) 1st Floor

194.87

165

32153.55

... More
15 mm thick plaster 1:6 External) a) Ground Floor

661.76

141

93308.16

... More
b) 1st Floor

198.78

145

28823.1

... More
10 mm thick plaster (Ceiling) 1:4 a) Ground Floor

553.53

126

69744.78

... More
a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.

1

7371

7371

... More
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]

460.41

1012

465934.92

... More
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone.

348.2

224

77996.8

... More
Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps.

460.41

209

96225.69

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC Two coats .

860.54

45

38810.35

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer., In Ground floor (Two Coat), a) Normal Acrylic Emulsion

860.54

67

57656.18

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats ii) Solvent based interior grade Acrylic Primer

1898.56

44

83916.35

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :i) Standard Quality (Two coats)

1898.56

62

117710.72

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.

7.2

3773

27165.6

... More
(a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved

225.99

2170

490398.3

... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in- charge.Weight of Strainless Steel railing per metre 6.5 Kg (approx)

13

7677

99801

... More
Supplying,Fitting & Fixing UPVC pipes A- Type and fittings confirming to IS : 13592 - 1992 with all necessary clamps nails,including making holes in wall, Floor etc. cutting trenches in any soil through masonry concrete structures etc. if necessary and mending good damags including joining with jointing materials (Spun Yarn,Valamoid/Bitumen/M-Seal etc.)Complete.

-

-

-

... More
A) UPVC Pipes (ii) 110 mm dia

49

251

12299

... More
© Bend 87.5 degree (ii) 110 mm dia

14

160

2240

... More
(d) Shoe (ii) 110 mm dia

14

111

1554

... More
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each i) For trusses spanning up to 12.00 m

0.38

74920

28469.6

... More
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

355.99

29

10323.71

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) Ground floor

355.99

79

28123.21

... More
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:- a) With 0.5 mm thick sheet

33

896

29568

... More
Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification onsmooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point 150 deg C, Cold Flexibility -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse)

527.16

407

214554.12

... More
Compacting original ground supporting subgrade Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Clause 305.3.4 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).

116.25

55

6451.88

... More
Construction of Sub Base using Local Materials, spreading in uniform layers with Motor grader on prepared surface, including screening the metal as necessary, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, lighting, guarding and barricading including cost and carriage of all materials and making necessary earthen bundh of one metre wide on each side to protect the edges complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).i) For Construction of Sub Base by compacting 1st class brick aggregates (40 mm down) and sand (in proportion of 60:40).

193.75

1733

335768.75

... More
Water Bound Macadam Base Course Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of cifications for Road & Bridge Works of MoRT&H (5th evision). (iii) Grading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm) B. Manual Means

193.75

3993

773754.19

... More
Supplying and Laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks ( with concrete grade as specified as per Table 1 of IS 15658:2006) manufactured in steel mould clumped to a vibrating table by hydraulic pressure (as per cl. No. 6.30 of IRC:SP:63 (2018), from BIS licensee manufacturer, with spacer nib (Small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per CL NO. 3.26 of IS:15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per CL. NO. 3.3 of IS:15658) as per Table 2 of IS:15658 with flexural strength / breaking load as epr Annexure G of IS:15658, on the prepared base course of specified CBR as per Table 1 of IRC SP 63 (2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35 mm thick (grading of the bedding sand as per Clause 6.5.1 of IRC SP-63) and filling up the gaps in between paver blocks with joint filing sand (the grading of the joint filling sand will be as per Clause 6.5.2 of IRC SP63) and completing the edges with cut blocks as per CL. NO. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edge gap. 80 mm thick. Grey

775

1184

917600

... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 for Rural Roads of MORD including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

104.63

104

10881.52

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches

139.5

24

3348

... More
Cement concrete with graded stone ballast (40 mm size) excluding shuttering ground floor and foundation with Proportion(6:3:1) (B) With N.B. Variety stone metal.

13.95

3485

48627.05

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety

62.78

6513

408886.14

... More
Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approved stout props with wooden planks/ply wood/steel sheet plate with required bracing for any kind of plain or reinforced concrete works in all sorts of minor structure including culvert, box culvert, crossdrain etc. The rate is inclusive of fitting, fixing and striking out after completion of work as per specification and direction.(b) Where staging is not required.

465

214

99510

... More
Electrification works

-

-

-

... More
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required ( Alluminiuam).

-

-

-

... More
4 bars,415 V, 200 A Dimension of Al. bars [85mm long] Dimension of Sheet Metal Box.500x150mm

3

3060

9180.6

... More
4 bars,415 V, 100 A Dimension of Al. bars [85mm long] Dimension of Sheet Metal Box.500x150mm

3

2730

8190.6

... More
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles

-

-

-

... More
19 mm dia 3 mm thick polythene pipe without earth continuity wire

900

69

62370

... More
25 mm dia 3 mm thick polythene pipe without earth continuity wire

2790

84

236313

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required

-

-

-

... More
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC

900

71

64350

... More
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC

2700

104

282150

... More
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC

90

542

48807

... More
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required

62

827

51286.4

-

-

-

... More
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (All L&T make)

-

-

-

... More
63 AMP

3

4545

13635.6

... More
160AMP

3

8802

26406.6

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish(2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC)

-

-

-

... More
Average run 8 mtr

176

1063

187211.2

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC

-

-

-

... More
On Board

62

83

5183.2

... More
SPN DB

-

-

-

... More
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.

-

-

-

... More
2+4 way

66

1217

80368.2

... More
Supplying and fixing 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection

-

-

-

... More
40 Amp

132

895

118192.8

... More
Supplying and fixing 2 WayMCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment

66

297

19602

... More
Supplying and fixing 6-32 A 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection

132

176

23232

-

-

-

... More
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting

31

266

8252.2

... More
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.

31

259

8047.6

... More
FITTINGS :

-

-

-

... More
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.

14

94

1324.4

... More
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.

62

218

13571.8

... More
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.

31

41

1295.8

... More
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set.

38

636

24202.2

... More
Supply of 20 watt SECURE LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy of 100 lumens/W. Model No.LTT8-20

76

701

53276

... More
Supply of 20 watt ECO Compact industrial batten suitable for single T8 LED tube.Model No.DIJB12LT8-20

76

330

25080

... More
Supply of 15 watt CLASSY LED 3 star Lamp. Model No-LHLDEUEEML8R015

31

248

7688

... More
Supply of 2 core 6 Sq mm XLPE AL Armoured Cable

320

139

44480

... More
Laying of cable 2 core 6 Sq mm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting

320

62

20064

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :2 core 6 Sq mm

30

74

2244

... More
Finishing the end of 2 core 6 Sq mm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials

30

35

1056

... More
Supplying and Fixing 200 x 150 x 100mm GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket ining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting

12

547

6573.6

... More
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.

12

887

10652.4

... More
Supply of 45 watt RAPTOR PRO street lights are aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. Efficacy ≥ 110/125/135LPW, 10KV SPD Included. Model No-CRP-409-45-57-SL-GL-NSG

12

4950

59400

... More
Supplying & Fixing CRC sheet metal 150 mm x 100 mm x 65 mm (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. kelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works

3

228

686.4

... More
Earthig arangement

-

-

-

... More
Excavation of soil for installation of Earth Electrode and filling & ramming for soft Soil.

16

236

3784

... More
Earthing with 50mm dia G.I. pipe (TATA-M) 3.64mm thick * 3.04 Mtrs. Long and 1*4 WG wire (4 Mtr. Long) 13mm dia * 80mm long G.I. bolts double washers incl. S&F dia pipe protection (1Mtr long) to be filled with bitumen partly under the G.L. and partly above G.L. driven to an average depth of 3.65Mtrs .below the G.L. and restoring the surface duly remmed

8

1676

13411.2

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe

8

1006

8052

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required

3

237

712.8

... More
Connecting the equipments to early busbar incl. S&F No. 8 SWG G.I. wire on wall /floor with stapels as per G.S.

120

9

1188

... More
Supply, Installation, Testing & Commissioning of 4.5 Kg Co2 Type Fire Extinguisher capacity IS 15683 : 2006 made from seamless cylinder conforming to IS : 7285 duly approved by Chief Controller of Explosive , Operating between -30°C to + 55 °C , Fire rating Class - 34B , Make : Fireshield Engineers (India ) Limited.

2

4657

9314

... More
Supply, Installation, Testing & Commissioning of 6 Kg ABC Stored Pressure Type consisting cylinder Fire Extinguisher capacity IS 15683 , Operating between -30°C to + 55 °C , Fire rating Class - 3A & 89 B , Make : Fireshield Engineers (India ) Limited.

2

1705

3410

... More
Supply, Installation, Testing & Commissioning of 9 Kg Volman Red Galvanized-Iron Safety Fire Bucket, Colour- Red, Material- Iron , Make- Generic or Equivalent

2

4708

9416

... More
Supply, Installation & Commissioning 9.9 Kw Roof Top Three Phase On Grid Solar System of cumulative roof top of elevated structure for 9.9 Kw for solar power plant with poly crystaline modules, Solar PV modules 330 wp 30 Nos, AJB, 2 I/P 2 O/P, with Fuse, SPD Type-II 1 No., Grid Connect Solar Inverter (1X5 Kw, 230 V AC 50 Hz MPPT) DC:AC=1:3 max 1 no., Dongle GPRS (wifi enable) 1 set, ACDB with SPD 3ph 1 set, Lightening Arrestor Height 2 Mtrs Conve 1set, Installation Kit (Comm Cable etc) 1 set . Make : Tata Power Solar System or Equivalent.

1

710446

710446

... More
CGST @ 9%

1

1236627

1236627.47

... More
SGST @ 9%

1

1236627

1236627.47

... More
Labour Welfare Cess @ 1%

1

162135

162135.6

... More
Service Connection (Payment will be reimburse on actual basis)

1

50000

50000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.