West Bengal State Marketing Board Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

West Bengal State Marketing Board - WBSMB Tender

Works
Civil And Construction
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date10 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 3,11,38,154 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceedin 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work)(ii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.

4699.6

419

1971858.17

... More
(c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration ) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part - II) 1981. (Mode of measurment will be per Sq.m. of plan area of plinth treated.)

1651.69

110

181685.9

... More
Post-construction Anti-termite measures (a) Anti-termite treatment to the outside of foundation with chemical emulsion by admixing chloropyrefos emulsifiable concentrates (1% concentration) with water by weight including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm from the ground level by rodding with 12mm dia. MS rod at 150mm interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the backfill earth by directing the spray of the emulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 4.3.1.1 of code IS-6313 (Part-III)-1981.

250.3

72

18021.6

... More
Filling in foundation and plinth by silver sand in layers not exceeding 150 mm as directed and consolidating same by through saturation with water ramming complete, including the cost of supply of sand.(Payment to be made on measurement of finished quantity)

1764.49

521

919421.76

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

359.5

24

8628

... More
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

1678.22

324

543744.25

... More
Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. In Ground floor.(Pakur variety). (a) 6:3:1 proportion.

172.42

4703

810910.07

... More
Ordinary Cement Concrete [ Mix 3 : 1.5 : 1 ] Cement concrete with graded stone chips (20 mm.size) excluding shuttering and reinforcement, if any, in ground floor.

19.84

5169

102552.96

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade,(i) Pakur Variety

622.57

5674

3532456.51

... More
1st Floor

7.14

5769

41184.89

... More
Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approved stout props with wooden planks/ply wood/steel sheet plate with required bracing for any kind of plain or reinforced concrete works in all sorts of minor structure including culvert, box culvert, crossdrain etc. The rate is inclusive of fitting, fixing and striking out after completion of work as per specification and direction.

198.4

214

42457.6

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. i) Foundation and Plinth.

1695.27

363

615384.1

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. i) Ground Floor

1559.56

363

566120.64

... More
1st Floor

80.55

381

30689.55

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (i) Tor steel/Mild steel. (a) For works in foundation, basement and upto roof of ground floor / upto 4m.(JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL)

97.74

54385

5315753.06

... More
1st Floor

0.84

54815

46099.42

... More
Brick work with 1st class bricks in cement mortar (6:1) . a) In Foundation and plinth.

346.39

4767

1651231.6

... More
Brick work with 1st class bricks in cement mortar (6:1) . b) In Super structure Ground floor

96.28

4990

480442.19

... More
Brick work with 1st class bricks in cement mortar (6:1) . c) In 1st floor

42.57

5101

217144.47

... More
125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in ground floor including for using approved H.B netting in every third layer above in any floor.

231.02

698

161249.87

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) .(ii) With 6:1 cement mortar. 15 mm thick with cement mortar(External). Ground Floor.

693.21

134

92890.14

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) .(ii) With 6:1 cement mortar. 15 mm thick with cement mortar(External). 1st Floor

317.92

138

43872.68

... More
(ii) With 6:1 cement mortar. (b) 20 mm. thick plaster (Internal). Ground Floor

1771.56

152

269277.12

... More
(ii) With 6:1 cement mortar. (b) 20 mm. thick plaster (Internal). 1st Floor

46.3

156

7222.8

... More
(ii) With 4:1 cement mortar. (c) 10 mm. thick plaster. Ground Floor

762.53

121

92265.53

... More
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.

478.38

33

15786.38

... More
Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point 150 deg C, Cold Flexibility -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse)

829.81

407

337731.04

... More
(a) Supplying fitting and fixing steel rolling shutter profile type with 18 B.G . Of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.

107.52

3270

351590.4

... More
Supplying fitting approved type ventilator in position after cutting holes in walls, setting in cement mortar mending damages to wall and plaster and two coats of paint of approved brand sand shade. Payment of mending two damages of wall & plaster and painting to be made separately. (b) R.C.C ventilator of 20 mm. thick.

22

108

2376

... More
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]

865.26

1004

868724.05

... More
1st Floor

40.89

1016

41544.24

... More
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. Ground Floor

2.31

9986

23109.64

... More
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.

5.04

1304

6572.16

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.

15.84

4330

68587.2

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc.

81.09

29

2351.61

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary .On Steel Surface.With super gloss (hi-gloss).(iv) Two coats (with any shade except white).

81.09

79

6406.11

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the Engg-in-charge.

693.21

45

31263.77

... More
In 1st floor

46.3

45

2121

... More
Protective and decorative acrylic exterior emulsion paint of approved quality as per manufacturers specification and as per EIC to be applied over acrylic primer as required. The rate includes cost of materials, labour, scaffolding and all incidental charges but excluding the cost of primer. In ground floor( two coats). a) Normal Acrylic Emulsion. Ground Floor.

693.21

67

46445.07

... More
In 1st floor

46.3

67

3134.97

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor). b) Two Coats. i) Water based interior grade Acrylic Primer.

2126.64

30

65500.36

... More
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats

2126.64

70

148864.45

... More
Supplying,Fitting & Fixing UPVC pipes A- Type and fittings confirming to IS : 13592 - 1992 with all necessary clamps nails,including making holes in wall, Floor etc. cutting trenches in any soil through masonry concrete structures etc. if necessary and mending good damags including joining with jointing materials (Spun Yarn,Valamoid/Bitumen/M-Seal etc.)Complete.110 mm Dia.

50.4

251

12650.4

... More
B) UPVC Fittings Bend 87.5 degree, 110mm dia

14

140

1960

... More
Shoe, 110 mm dia

14

111

1554

... More
Supplying fitting fixing fan hook for ceiling with 1 metre long 16 mm dia rod complete including mending damages.

32

100

3200

... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)

33.8

9077

306802.6

... More
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).In Roof,a) With 0.5 mm thick sheet

146.02

896

130832.13

... More
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)

81.6

665

54264

... More
Compacting original ground supporting subgrade Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Clause 305.3.4 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).

231

55

12820.5

... More
Construction of Sub Base using Local Materials, spreading in uniform layers with Motor grader on prepared surface, including screening the metal as necessary, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, lighting, guarding and barricading including cost and carriage of all materials and making necessary earthen bundh of one metre wide on each side to protect the edges complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (i) For Construction of Sub Base by compacting 1st class brick aggregates (40 mm down) and sand (in proportion of 60:40).

385

1604

617540

... More
Water Bound Macadam Base Course Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (iii) Grading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm) B. Manual Means

385

2264

871640

... More
Supplying and Laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks ( with concrete grade as specified as per Table 1 of IS 15658:2006) manufactured in steel mould clumped to a vibrating table by hydraulic pressure (as per cl. No. 6.30 of IRC:SP:63 (2018), from BIS licensee manufacturer, with spacer nib (Small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per CL NO. 3.26 of IS:15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per CL. NO. 3.3 of IS:15658) as per Table 2 of IS:15658 with flexural strength / breaking load as epr Annexure G of IS:15658, on the prepared base course of specified CBR as per Table 1 of IRC SP 63 (2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35 mm thick (grading of the bedding sand as per Clause 6.5.1 of IRC SP-63) and filling up the gaps in between paver blocks with joint filing sand (the grading of the joint filling sand will be as per Clause 6.5.2 of IRC SP63) and completing the edges with cut blocks as per CL. NO. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edge gap. 80 mm thick. Grey

1540

1107

1704780

... More
Labour for boring through any type of soil for sinking Tube - Well of required dia with top enlargement by rig boaring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants stagging, force pumping set and making arrangements for water required for boring etc. complete and lowring of pipes, strainer, blind pipes etc. complete. (a) For depth up to 250 M. for 100 mm. dia tube well with top enlargement of 200 mm. dia. (up to 50 M.)

-

-

-

... More
for first 50 Mtr.

50

1014

50700

... More
for next 50 Mtr.

50

883

44150

... More
for next 50 Mtr.

50

1055

52750

... More
for rest 100 Mtr.

100

1091

109100

... More
Supplying fitting and fixing PVC pipes of approved make of (medium duty) conforming to ASTMD - 1785 & Threaded to match with GI pipes as per IS : 1239 (Part - I). With all nacessary accessories, specials viz socket, bend, tee, union, cross, elbo, nipple, longscrew, R/socket, R/tee, short piece etc. fitted with holder bats clamp, including cutting pipes, making threads, fitting fixing etc. complete in all respect including cost of all necessary fittings as required jointing materials and two coats of paiting with approved paint in any position above ground. (Payment will be made on centre line measurement of the total pipeline including all specials.No separate payment will be made for accesories, specials.)

-

-

-

... More
a) 200 mm.internal dia

48

2716

130368

... More
b) 100 mm. internal dia

165

1162

191730

... More
Supplying of High Density Polythene stainer of approved make with adapter conforming to I.S.specifications.

-

-

-

... More
(II) 100mm. dia

30

1319

39570

... More
Supplying, G.I. TATA Pipe ( 150 mm dia.)

2

1510

3020

... More
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg. per sq.cm. (for water lines only) .(iv) 50 mm. Dia.

1

2277

2277

... More
Supplying, Fitting & Fixing Steel cutter Piece upto 450 mm long (50 mm dia.)

1

189

189

... More
Supplying, Fitting & Fixing 200 X100 mm dia Reducing socket

1

865

865

... More
Washing and developing Tube - Well with air compressor pump and engine for 8 ( eight) hours continious pumping per ay with necessary arrangement for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required. For 3 (Three day's)

3

7538

22614

... More
Packing the annular space between the out side of the Tube Well pipe and strainers and the bore ith pea size washed gravel of approved quality having size from 2 mm. to 5 mm. or the size approved by the Engineer - in charge including cost of all materials labour and equipment complete.

5

2029

10145

... More
Geophysical Investigation of the acquifer by electrologging system with all tools & plants as necessary including supply of necessary report.

1

8247

8247

... More
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.

1

1231

1231

... More
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required

106

165

17577.98

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required

-

-

-

... More
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC

1408

66

94265.6

... More
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC

720

97

70452

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish(2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC)

-

-

-

... More
Average run 9 mtr

186

1092

203266.38

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC

-

-

-

... More
On Board

18

78

1409.04

... More
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles

-

-

-

... More
25 mm dia 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire

2128

81

173155.36

... More
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (All L&T make)

-

-

-

... More
100AMP

2

7559

15118.34

... More
200AMP

1

10712

10712

... More
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required ( Alluminiuam).

-

-

-

... More
4 bars,415 V, 200 A Dimension of Al. bars [85mm long] Dimension of Sheet Metal Box.300x150mm

2

2865

5730.92

... More
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.

-

-

-

... More
2+6 way

17

1238

21047.02

... More
Supplying and fixing 240V MCB Isolator on din rail of existing DBs and necessary connection.

-

-

-

... More
40 Amp

49

324

15898.05

... More
Supplying and fixing 2 WayMCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment

32

278

8899.2

... More
Supplying and fixing 415 V MCB Isolator on din rail of existing DBs and necessary connection.

-

-

-

... More
Supplying and fixing 6-32 A 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection

102

164

16809.6

... More
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.

64

179

11470.08

... More
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.

64

243

15557.12

... More
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m.Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in- Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor

4

2533

10133.32

... More
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.

16

39

626.24

... More
Supply of 2 Core 4 Sq mm Alluminium XLPE /PVC Armoured cable for 16 A DP main switch to Out side DP Main Switch and Out Side DP Main Switch to Different Wall Bracket Light Point.

482

106

51092

... More
Laying of cable 2 core 4 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting

482

58

28298.22

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables of 2 core 4 sqmm

24

64

1557.36

... More
Finishing the end of 2 core 4 sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials

24

31

766.32

... More
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamp with bolts, nuts etc. including painting with anticorrosive paint

12

471

5660.88

... More
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite / Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. Supply & Fixing 240 V 16A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required

1

289

289.43

... More
Supply of 45 watt RAPTOR PRO street lights are aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. Efficacy ≥ 110/125/135LPW, 10KV SPD Included. Model No-CRP-409-45-57-SL-GL-NSG

12

4928

59142.6

... More
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.

12

831

9974.52

... More
Excavation of soil for installation of Earth Electrode and filling & ramming for soft Soil.

8

221

1771.6

... More
Earthing with 50mm dia G.I. pipe (TATA-M) 3.64mm thick * 3.04 Mtrs. Long and 1*4 WG wire (4 Mtr. Long) 13mm dia * 80mm long G.I. bolts double washers incl. S&F dia pipe protection (1Mtr long) to be filled with bitumen partly under the G.L. and partly above G.L. driven to an average depth of 3.65Mtrs .below the G.L. and restoring the surface duly remmed

4

1569

6278.88

... More
Extra treatment of soil by using salt and charcoal for pipe electrode as required.

4

546

2187.72

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe

4

942

3769.8

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required

2

222

444.96

... More
Connecting the equipments to early busbar incl. S&F No. 8 SWG G.I. wire on wall /floor with stapels as per G.S.

40

9

370.8

... More
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required

-

-

-

... More
40 mm dia

36

253

9121.68

... More
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish

-

-

-

... More
From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.

40

130

5232.4

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below

-

-

-

... More
upto 16 sqmm

6

135

815.76

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials

-

-

-

... More
4 core16 sqmm cable

16

97

1565.6

... More
Supplying of one no 4 core 16 sqmm Alluminiuam armoured cable. Make : Havells/ Mascab/ Pollycab.

40

259

10360

... More
Supply of 40 watt TRIMLINE is a robust and high performance batten. This LED luminaire comprises of extruded channel in thermally conductive material. High translucent serrated milky white diffuser is used to get glare free and smooth light distribution. Efficacy : 100 lumen/watt Model No.CCS-100-40-40-SL-DP-NWH

106

990

104940

... More
Supply& Fixing of 9M high mini mast suitable for wind speed 50m/s made up of IS 5986/IS 2062/IS 1239 or Eqiv from Hot dip galvanized iron -IS 4759 with head fram suitable for fixing 4 nos solar plate and luminaries carrige suitable to install 4 nos. luminaries in symmetrical arrangement with ss rope and trun buckle softy arrangement.The shaft ill be bottom diameter-320mm top diameter 120mm thikness 4mm, base plate 520mmx520mm and 16 mm thickness . The mini mast should have inbuilt Junction box for termination of cable, battery box structure for accomodating rotorised 4 nos solar battery and ladder arrangement for maintenance of solar plates, luminaries etc, L type foundation bolt M24x800mm (4 Nos) is to be supplied with the mast as required ( Make: Kolkata Pole Corporation/Transrail/Utkasrh/BPC)

2

42032

84064

... More
construction of suitable shallow reinforced foundation as per standerd design as per the manufacturer with 1:1½:3 cement concrete M-20 Gr, for the High Mast considering the safe soil bearing capacity at site as 10T/ Sq mtr. TMT steel as per IS(0.5% of CC Volume) and about said depth along with suitable dimension that confirms safe bear of high mast with height of 300 mm above ground incl all materials and labour complete in all respect as per direction of E.I.C. the civil foundation work incl. for erection of upto 9 mtr high mast tower by earth work in excavation of foundation trench approx. Total foundation is 800x800x1500mm with 800x800x900mm below GL zone including earth work in excavation , single brick flat soiling, shuttering with centering reinforcement for reinforced concrete work in all sorts of structures,ordinary cement concredte (Mix1:1½:3) with gradded stone chipes( 20 mm size) and making 15mm thick pplaster complete as per modern engineering practice.

2

17484

34968

... More
Supply & installation Solar Mini mast Lighting system ( fixed type) with 4 nos 33w DC LED flood light having initial luminaire lumen output of minimum 4500LM (As per LM79 report of NABL Approved lab) and IP65 protection ( As per test report). With lithum ferro phosphate battery operating at 25.6 v with solar charge controller having the bluetooth based system health scanner and programmer for the monitoring of 12.76kwh capacity of 200wp or higher battery & sollar pannel performance parameters via Android App based mobile application on mobile phone and tablet to monitor the health condition & performance . All the components like PV MODULE, Battery, Luminaries & charge controller will be supplied by the companey and 2 yeard comprehensive warranty againest any manufacturing defects . Make : Philips/ Wipro/ Havells

2

237796

475592

... More
Erection, testing & commissioning of 9 mtr length mini mast solar panel LED flood light along with 3x1.5 sqmm copper with Co's own tools, trackles, crane including labour charges & carrying as per direction of EIC

2

6500

13000

... More
Excavation of soil for installation of earth electrode and filling & ramming for Morrum soil

4

215

860

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04Mts long with ISI Medium GI Pipe as per GS

2

1369

2738

... More
Connecting the equipments to earth busbar including S&F solid GI (Hot Dip) wire of sixe as bellow as per GS 7/14SWG stransed Gi wire

10

16

160

... More
Extra for providing masonary encloser on the top of the earth electrode of overall size 86.36cmx 86.36cm x 46cm deep (below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement GI reducer including drilling of 46nos 12 mm dia holes on the Gi pipe.

2

915

1830

... More
Add SGST @9.00%

1

2343878

2343878

... More
Add CGST @9.00%

1

2343878

2343878

... More
Add LWS @1.00%

1

307308

307308.44

... More
Electrical Service Connection (Payment as per actual demand of WBSEDCL )

1

100000

100000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.