West Bengal State Fishermens Cooperative Federation Limited Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
West Bengal State Fishermens Cooperative Federation Limited - BENFISH Tender
Civil And Construction
Building Construction
Eprocure
Opening Date23 Feb 2024
Closing Date9 Mar 2024
Tender Amount₹ 12,63,773
Costs
EMD
₹ 25,275Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BENF_673252_1Bid Award Id
ViewTender No
BENFISH/MD/NIT-04(e)/ 2023-24Tender Authority
West Bengal State Fishermens Cooperative Federation Limited ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Rendering the Surface of walls and ceiling with White Cement base
WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
92
11224
122
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement if any, a) in ground flooras per relevant IS codes.(i) Pakur Variety
6.9
42159
6110
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m.using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams,columns, lintels curved or straight including fitting fixing and strking out after completion of works.
25 mm. To 30 mm. Thick wooden shuttering as per decision & direction of EIC a) In Ground Floor
36
12060
335
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars stirrups binders etc, including supply of rods, initial straightening and removal of loose rust (if necessary) cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge annealed wire at every intersection complete as per drawing and direction.
0.35
20387
58249
Supplying and laying Polythene Sheet (150gm/sqm/) over damp proof course or below flooring or roof terracing or in foundation trenches.
28
672
24
Brick work with 1st. Class bricks in cement mortar (4:1)
a) In foundation and Super structure.
6
34788
5798
125 mm. Thick brick work with 1st. Class brick in cement mortar (4:1) a) In Ground Floor
17
12308
724
Plaster (to wall, floor, celling etc. ) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chipping etc. including throating, noising and drip course where necessary. 20 mm thick plaster
256
42752
167
Supply and Installation Digital Fountain Aquarium,Glosine Board and Counter Desk with other Decoration
1
200000
200000
Neat cement punning about 1.5 mm. thick in wall, dado window sills, floor drain etc.
Note : Cement 0.152 cum. Per 100 sqm.
56
1904
34
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
78
1482
19
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
299
26312
88
Wood work in door and window frame fitted and fixed complete including a protective coat of painting at the contact surface of the frame.
Sal : Siliguri
0.32
31395
98112
Supplying fitting & fixing frames for Fire resistant acoustic door shutters 1st class Malaysian Hardwood Frame (densified to 810 kg/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per
IS:1141 of section 120 mm X 70 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with standard double acoustic seal (equivalent to Hafele) placed along two faces of rebate for sound insulation and single row of Brush- Type intumescent strip of size 10 mmx 4 mm affixed in the slit of the
Frame for fire and smoke sealing, etc. complete as per direction of Engineer - inCharge including a protective coat of painting at the contact surfaces of the frame excluding cost of concrete,Iron butt hinges and M.S clamp at Ground Floor. [Note : Specific permission of the Superintending Engineer is required for
execution of this item. ]
6.8
10261
1509
Supplying fitting & fixing frames for Fire resistant door shutters made of 1st class Malaysian Hardwood (densified to 810 kg/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 of section
75 mm X 50mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type intumescent strip of size 10 mmx 4 mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete as per
direction of Engineer -inCharge including a protective coat of painting at the contact surfaces of the frame excluding cost of concrete,Iron butt hinges and M.S clamp at Ground Floor. [Note : Specific permission of the Superintending Engineer is required for execution of this item]
18
19872
1104
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor.(a) 1st class best Indian teak.
4
28964
7241
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mmwide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf)
8
21272
2659
Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receiveDistemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per manufacturer's specification andas per direction of the EIC. (In Ground Floor)b) Two Coatsi) Water based interior grade Acrylic Primer
120
5304
44.2
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.
Two Coats
120
8400
70
(a)Cleaning the walls and ceiling by scraping, sand papering and
smoothening down the surface including putting.
95
1615
17
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(b) Two Coats
166
7486
45.1
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.c) Super Protective 100% Acrylic Emulsion.
166
16102
97
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick
with uniform texture & without decorative veins in columns,
wall, facia,rise etc. with 15 mm thick [avg] cement mortar
(1:2) including making suitable arrangements to hold the
stones properly by brass / copper hooks including pointing in
cement mortar (1:2) (1 white cement : 2 marble dust) with
admixture of pigment matching the stone shades all complete
as per direction of the Engineer-in-charge including cost of all
materials, labours, scaffolding, staging, curing and
roughening of concrete surface complete.
[Using cement slurry at back side of granite @ 4.4 kg/sq.m &
white cement slurry for joint filling @ 1.8 kg/sq.m]
In ground floorb) Area of each Granite slab above 1.00 Square meter.
11
34936
3176
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the
Engineer - in - Charge
155
13950
90
Artificial stone in floor, dado, staircase etc with cement
concrete (1:2:4) with stone chips, laid in panels as directed
with topping made with ordinary or white cement (as
necessary) and marble dust in proportion (1:2) including
smooth finishing and rounding off corners including raking
out joints or roughening of concrete surface and application
of cement slurry before flooring works using cement @ 1.75
kg/sq.m all complete including all materials and labour.In ground floor.
3 mm. thick topping (High polishing grinding on this item is
not permitted with ordinary cement).
Using grey cementiii) 35 mm. thick
135
44550
330
Supplying, fitting & fixing Glass mosaic tiles at finished plain
wall surface of size 20 mm x 20 mm x 4 mm in all colour,
design, fixing in customize design as per direction of Engineer-
in- Charge. The glass mosaic tiles to be fixed on the wall
surface with the help of approved adhesive applied at the rate
of 2.5 kg per sqm and grouting of the same. The rate is
inclusive of all operation, material and required pattern
approved by Engineer-in-Charge. [At Ground Floor]iii) Mural aligned/ CAD Design Type
7.83
28301
3614
Supplying and laying true to line and level Double Charge
Vitrified Tiles of approved brand conforming to IS 15622:
2006 (Group B I a) and tested as per IS 13630:2006 (relevant
parts) [Non-modular sizes for tiles with Water Absorption (av.)
≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of
6mm thick layer applied directly over finished artificial stone
floor/Mosaic etc without any backing course and joints
grouted with admixture of white epoxy grout materials of
approved brand including spacer -2mm as directed and
removal of wax coating of top surface of tiles with warm water
and polishing the tiles using soft and dry cloth upto mirror
finish complete including the cost of materials,Iabour and all
other incidental charges complete as per direction of Engineer-
in-Charge. (Note: This work should not be executed without
specific permission of Superintending Engineer)
75
117450
1566
Supplying,fitting and fixing 1st quality Ceramic tiles in walls and floors to match with the existing work. set in sand cement muter 4 nos. of key stones (10 mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide (if requested) to match the colour of tiles including ...synthetic adhessiie or grout materials etc.
35
40040
1144
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other
incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)(b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating)
11
31658
2878
M.S. structural works in roof trusses with tubular sections
conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one
another with bracket, gusset cleats as per design, direction of
Engineer-in-charge complete including cutting to requisite size,
fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.i) For trusses spanning up to 12.00 m
1.26
74929
59468
S upplying, filling & Fixing of roofing slteet of colour coalted 0.45mm Base Metal Thickness( BMT) (0.53 mm TotaI/ P Tltickness excluding paint(TP1)) of 700 mm effectil•e COl'er wit/tit , 43mm deep rib spaced at 233mm clc along witlt mi cro stiffeners perpendicul"r to ribs for strengtlt. Tlte steel slteet slta /1 ltm• e minimum yield strengtlt of 5501\f Pa, metallic coated of Zincalume , Aluminium Zinc alloy AZ/ 5() , conforms to IS I 596 1, pre-painted with inorgani c pigments super durable
po(rester(SDP) colorbond xrw ( xterior roofing and walling ) with higher SRI ( solar reflecti,•e index) value Tltermatech technology conforms to IS 15965 class 3. The sheets shall be fixed to every pur/i11 by means of clips - K/ .7 0 . The clip Kl - 70 shall he f{IS/ened with nominal 40µm :in c CO{lted or nominal 25µm :i nc- fi n alloy CO{l fed, lfrx head, ulf-drilling screw {IS per AS 3566-2002 Class 3 fasreners. The profile sheer .It al/ he of same parenr of coil. The profile sheet, fastener size ere. shall be appro,•ed by tlte concern aurltori ty. Tlte measurement ., It al/ he b{lse,I on
lr,11is he1ll covered surface"' ea. (Nore: S pecific p,•rmission of theC!ti, f Engineer i.•\ required/or execution of t/ti.,• item)
25
26075
1043
Supplying, fitting & fixing polycarbonate sheet of approved
make & brand conforming to IS: 14443-1997 and having 50
micron UV protection layer under co-extrusion technology,
Fire rating being B-s1 as per EN13501-1 certification, fitted
and fixed with 60mm wide aluminium channel section top
and bottom member in dry-glaze sandwitch system, (unit wt.
of top and bottom members: 0.375 kg/m & 0.69 kg/m) of
approved brand and profile, EPDM quality rubber gaskets,
anti dust tape, end closer "C" channel and 75 mm long Self
tapping screw being drilled through the centre leg of the
bottom section with nuts placed at 300 mm apart without
anyway puncturing the polycarbonate sheet, EPDM Washer
16 mm dia & 3 mm thick washer etc complete strictly as per
manufacturers specification and direction of Engineer-in-
Charge. (Payment to be made on area of finished work) .
In Roof:-
Natural/ Blue/Green/Bronze/Opal/Metallic grey colourb)With 2 wall 8 mm overall thickness
(wt.1.50kg/sqm,Ugvalue being 3.3 W/m2K, Min. cold bending
radius of 1200 mm)
22
29172
1326
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(ii) Double Socketed 3 Meter Length(b) 110 mm
37
11655
315
35 mm. thick (finished) terrazo work, cast in situ in floor and
20 mm. thick (finished) in dado, skirting staircase etc. laid in
panels or pattern using cement concrete (1:2:4)backing with
12 mm stone chips as directed and necessary terrazo topping
with mosaic chips including rounding off corners and high
polishing etc. complete as per specification laid down in I.S :
2114-1962 including raking out joints or roughening of
concrete surface & application of cement slurry before
flooring works using cement @ 1.75 kg./sq.m. all complete
including all materials & labour.
(Add extra @ 1.5% for each additional floor upto 4 th floor
and @ 1.75 % for each addl. floor above 4 th floor)
[White cement for item No 9 of subhead A to be supplied by
the contractor including cost thereof and grey cement willbe
supplied by the Dept at the isuue rat(A) 9 mm. thick terazo topping, laying and finished to 6 mm.
thick after final grinding with 0 to 7 mm. size mosaic chipsv) In pink, green, yellow, light green colour using white
cemeny only and necessary pigment.
160
130720
817
Labour for fitting and fixing U.P.V.C. pipes for above ground work
including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-
charge. (Payment will be made on centre line measurement of the total pipeline including specials.(A) Above ground(ii) 110 mm dia.
11.97
682
57
Supplying bubble free float glass of approved make and brand
conforming to IS: 2835-1987
vii) 8mm thick clear glass.
10
8480
848
M.S. or W.l. ornamental grills of approved design, joints
continously welded with M.S., W.l. flats and bars for
windows, stair railings etc. fitted and fixed with necessary
screws and lugs in any floor.
Grill weighing above 16 kg/sq m and above.
326
32234
98.88
Providing, fitting and fixing in position, medium density fibre board conforming
to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood
fibre bonded with Urea formaldehyde for interior grade and Phenol
Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved
make and brand as per direction of Engineer-in-Charge.n Ground FloorC) Both side decorative laminationII) Interior Grade(ii) 12mm
6
5280
880
Supply Fitting and Fixing Window Cartain with Splited Banboo wooven with Cotton Rope
18
18000
1000
Sanitary Plumbing Work
1
35000
35000