West Bengal State Cooperative Marketing Federation Limited Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
West Bengal State Cooperative Marketing Federation Limited - BENFED Tender
Electrical Goods and Equipments
Eprocure
Opening Date2 Jan 2019
Closing Date18 Jan 2019
Tender Amount₹ 11,12,163 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 22,243Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_SCMFL_204568_1Bid Award Id
ViewTender No
SCMF/ENG/WIF/E/26/18-19Tender Authority
West Bengal State Cooperative Marketing Federation Limited ViewPurchaser Address
-Website
http://https://www.benfed.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply & fixing of 240V /32A sheet steel DP switch fuse unit on angle iron frame . Including making necessary connection & mending good damages to original finish.
1
-
-
Supply & fixing of indoor type LT cubicle pattern wall/Floor mounted panel board complete with Eye bolts, Channels(if required) & all necessary hardware required. The panel board shall be made of sheet steel (CRCA). The thickness of sheet shall be of minimum 2mm . The panel should be finished with powder coated epoxy paints.This panel is to be fixied on wall to receive and distribute power and shall comprise of the following:
a) 415V 250A TPN SDF as incomer
of the LT panel with connection box -1no (if required)
b) 500A TPN Aluminium cubical busbar chamber-1set
c) 415V/63A SDF mainswitch-4 nos
d) 415V/240V/32A DP SDF main switch(As directed by EIC-3 no. e) Suitable range Ammeter & voltmeter with selector switch. f) watt hour meter with suitable connection & range
making complete inter connection with adequate size of copper wire/aluminium bars,jointing materials etc.The shall be duly earthed with 10SWG GI wire incl. mending good damages to original finish.
1
-
-
Supply & laying of 1.1KV grade 2core 10 sq.mm PVC armoured Al. cable in under ground trench 460
X 760mm average depth with brick protection on the top of the cable with 8 nos bricks per mtr filling
the space between the brick and the cable and also the trench with shifted soil & restoring the surface duly rammed.
20
-
-
Supply & laying of 1.1KV grade 2core 6 sq.mm PVC armoured Al. cable in under ground trench 460
X 760mm average depth with brick protection on the top of the cable with 8 nos bricks per mtr filling
the space between the brick and the cable and also the trench with shifted soil & restoring the surface duly rammed.
60
-
-
Supply & laying of 1.1KV grade 2 core 6 sq.mm PVC armoured Al. cables after cutting floor/pavement/wall and making holes incl. embedding the cable at an avg. depth of 75mm and mending good damages to original finish including removing the rubbish from the work place.
90
-
-
Supply & laying of 1.1KV grade 4 core 10 sq.mm PVC armoured Al. cables on wall /surface incl. supply & fixing of M.S. saddles for fixing the cables with earthing attachment with 2 nos 10SWG GI (Hot Dip) wire, making holes etc. as necessary & mending ,good damages & painting the following.
130
-
-
Supply & laying of 1.1KV grade 4 core 10 sq.mm PVC armoured Al. cables after cutting floor/pavement/wall and making holes incl. embedding the cable at an avg. depth of 75mm and mending good damages to original finish including removing the rubbish from the work place.
15
-
-
Excavation of soil for installation of earth electrode and filling and ramming for soft soil.
10
-
-
Earthing with 50mm dia GI pipe (ISI) medium grade
3.64mm thick x 3.04 mts long and 1x4 SWG GI
(hotdip) wire 4mt, 13 mm dia x80mm long GI bolts , double washers incl. supply and fixing 15mm dia GI pipe protection (1mt long) to be filled with bitumen partly under the gr. level and partly above ground level driven to an average depth of 3.65mts below the ground level & restoring the surface duly rammed.
10
-
-
Extra for providing masonry enclosure on the top
of the earth electrode of overall size 86.36cm x86.36
cm x 46 cm deep (below gr. Level) complete with cemented brick work(1:6) of 25cm width duly plaster-
ed with cement morter(inside) CI hinged inspection cover of size 36.56cm x 35.56cm with locking arrangement , GI reducer including drilling of 46nos 12 mm dia holes on the GI pipe.
10
-
-
Extra for treatment of soil by using salt & charcoal or coke for electrode.
10
-
-
Supply & fixing earth busbar of galvanized (Hot dip)
MS flat 25mm x6mm on wall having clearence of 6mm from the incl. providing drilled holes on the busbar complete with GI bolts, nuts, washer , spacing insulator etc. as required.
8
-
-
Connecting the earth busbar incl. supply and fixing GI (hot dip) wire of 8 SWG on floor /wall with staples buried in side wall/floor /as required and making connecting to the Earth electrode with PVC cover ,bolts, nuts, washer , cables lugs etc. as required and mending good damages to original finish.
180
-
-
Supply & drawing of 3x10sq.mm submersible cable suitable for 5HP submersible pump.
30
-
-
Supply & Fixing compression type cable gland complete with brass gland, brass ring
and rubber for dust & moisture proof entry
of PVC armoured cable.
-
-
-
4 core 10 sq.mm PVC/A
6
-
-
2 core 6 sq.mm PVC/A
56
-
-
Finishing of cable ends by crimping method including supply & fixing solder less sockets tape anticorrosive paste and jointing materials.
-
-
-
4 core 10 sq.mm PVC/A
6
-
-
2 core 6 sq.mm PVC/A
56
-
-
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sq. mm ) single core stranded FR PVC insulated and unsheathed copper wire (app. Make) in suitable size of PVC casing capping (precision/AKG make) with 1x22/0.3(1.5 sq.mm) single core stranded FR PVC insulated copper wire for ECC including necessary PVC clips fittings etc. to light/ fan/outdoor light point with piano key type switch(Approved Make) fixed on the sheet metal fabricated switch board with perspex/bakelite top cover on wall/inside the panel box including necessary connection and making earthing attachment and making earthing attachment & making good damages to building works.[PVC casing caping & switch board both on surface.]
-
-
-
Avg. run 5 mtr
18
-
-
Avg. run 6 mtr
6
-
-
Avg. run 9 mtr
8
-
-
Avg. run 12 mtr
10
-
-
Supply & fixing CRC sheet metal (16SWG) JB cum loop box of 150mm x100mm x65mm size complete with three nos suitable size copper bar with holes for ph, N & E fixed on bakelite /Hard Rubber insulator over the MS welded chairs including bakelite/perspex/colour perspex (wall matching colour) top cover 3mm thick flushed in wall /channel/truss/of the godown including making earthing attachment ,painting and mending good damages to original works.
22
-
-
Distribution wiring in 1.1KV grade 2x1.5 sq.mm stranded FR PVC insulated & unsheathed copper wire (Brandapproved by EIC)in suitable size PVC casing cappingwith1.5 sq.mm stranded FR PVC insulated & unsheathed copper wire for ECC, including necessary PVC clips , fittings etc. to 5A/6A pin flush type plug socket with piano type switch(Approved brand) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex top cover of 3mm thick flushed in wall by housing the board after cutting brick wall including necessary connection making earthing attachment , painting & mending good damages to building works.[PVC casing caping & switch board both on surface.]
-
-
-
On board socket
5
-
-
Avg. run 3 mtr
4
-
-
Supply & fixing 240V, 3 nos 6A & 1 no. 20A plug socket with separate 3 nos 6A & 1 no. 20A piano key type switch with indicator (Brand approved by EIC) on sheet metal switch board embedded in wall including supply & Fixing 240mm X 200mm X65 mm MS(16SWG) switch board & bakelite/Perspex top cover of 3mm thick by brass screws after making housing for switch by cutting bakelite/perspex cover & making necessary connections as required.
2
-
-
Supply & fixing 240V, 6A plug socket with separate 6A piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall including supply & Fixing 240mm X 200mm X65 mm MS(16SWG) switch board & bakelite/Perspex top cover of 3mm thick by brass screws after making housing for switch by cutting bakelite/perspex cover & making necessary connections as required.
4
-
-
Supply & Fixing of cubical box type board with 16SWG metal sheet & MS angles on all sides and front hinged cover with locking arrangement . The cubical board will be fixed on to the wall with the cover flush with outside surface of the wall near one of the entrance of the new godown, by concealed system including cutting the wall & plastering the same with neat cement finish. The cubical board shall consist of the following: i) 1 no. 6 way TPN single door DB ii) 63A 4 pole isolator -1no.
iii) 6/16A SP MCB(C series 10KA) - 15 nos
iv) M.S. switch boxes with 16A/6A/10A switch as per requirement /direction of EIC for individual or group lighting (Minimum nos of switch on board is 36 nos it may be extended on site condition for group control & spare in case of individual control switch as per requirements)
v) 440V with Danger plate on board.
vi) wire loop box of suitable size-1 no.
vii) 16A socket with switch on MS box-1 set
All above equipments will be mounted cubicle (totally enclosed type) sheet metal box . The inter- connection between isolator , neutral, bar earthed bar , MCB & switch boxes shall be made with adequate size of copper wire and both ends of wire shall be provided with copper lugs, sockets by crimping method, And covered with coloured PVC insulated tapes . This box is to be painted with two coats of approved anti-corrosive paint over one coat of Red Oxide primer and complete with proper earthing arrangements incl. mending good damages to original finish.
2
-
-
Supply & fixing single rail type LED light fittings complete with 18watt cool white LED tube directly on wall /Hw wooden block with suitable size of fastener.
6
-
-
Supply & fixing 36watt CFL lamp on angular batten holder on wall.
2
-
-
Supply & fixing of 500/600mm sweep wall mounted fan including all necessary accessories and making necessary arrangements and making necessary connections as directed by EIC.
4
-
-
Supply & fixing of Submersible pump panel on flat angle iron suitable for 5HP submesible pump complete with necessary connection arrangement.
1
-
-
Supply & fixing 50mm dia G. I. protection pipe (medium ISI make) for protection the cable under the road & and also used as a riser of the cable incoming including mending good damages to the original finish.
60
-
-
Supply & fixing including wiring of 250V 5 pin 16A flush type plug socket with 16A piano key type (approved make) switch on sheet metal box with bakelite top cover and earthing arrangements incl. supply and fixing of 16SWG metal box and bakelite cover.
5
-
-
Supply drawing 1.1KV grade 2x2.5sq.mm + 1x1.5sq.mm FR PVC strandard copper wire for main line wiring in rigid PVC pipe or casing from MCB DB to the nearest JB/switch board for main line wiring.
210
-
-
Supply drawing 1.1KV grade 3x6sq.mm + 2x4sq.mm FR PVC strandard copper wire for main line supply from meter panel to the nearest incomer of the LT panel.
20
-
-
Distribution wiring through 20mm dia PVC rigid pipe complete with all fittings as necessary recessed in wall /surface with 22 SWG AL saddle incl. supply & laying of 3 nos 1.1KV grade single core stranded FR PVC insulated unsheathed 1.5 sq.mm copper wire (approved make) inside pipe and fittings in loop-in loop-out system to indoor light points of godown including making good damages to original finish.
550
-
-
Distribution wiring with 1.1KV grade 2 core 6 sq.mm PVC armoured aluminium cable on wall/surface/truss including supply and fixing MS saddles with earthing attachment in 10SWG GI (Hot dip) making holes etc. as necessary mending good damages in loop-in loop-out system to indoor light points in godowns.
520
-
-
Supply & fixing cast aluminium out door type bulkhead light fittings including supply of 36watt CFL lamp and this fittings should be held with bracket made from GI pipe of suitable dia complete making connections as required and mending good damages to wall incl. painting.
2
-
-
Supply & fixing of 4 way TPN Double door DB on wall including supply & fixing of 63A 4P isolator & 6 nos 6A SP C series MCBincluding necessary connection arrangements and also keep 6mm clearance from wall.
2
-
-
Supply & fixing of 4 way SPN single door DB on wall including supply & fixing of 40A 2P isolator & 2 nos 6A SP C series MCBincluding necessary connection arrangements and also keep 6mm clearance from wall.
1
-
-
Supply & fixing loop box of suitable size made from CRC sheet in which fuse facility should be provided for individual fittings without distruption of other fitting in the loop -in loop-out system . The box including the cover should be painted with a non-corrosive paint complete with mechanical locking arrangement with earthing attachment and earthing terminal with lug and one neutral link on porcelain insulator etc. incl. mending the good damages to original finish.
24
-
-
Supply of 12ft (less than) self supporting aluminium ladderfor future maintainence purpose.
2
-
-
Supply & fixing of 4"x4" PVC box with cover used as a pull box for long run of PVC copper wire.
16
-
-
Supply & fixing of Dry Chemical Powder(DCP) type fire extinguisher with GM cap and complete refill conforming to IS-15683 validity 1 year's effectiveness for electrical fire and other fire moderate.[capacity not less than 6Kg]
18
-
-
Supply & fixing of Dry Chemical Powder(DCP) type fire extinguisher with GM cap and complete refill conforming to IS-15683 validity 1 year's effectiveness for electrical fire and other fire moderate.[capacity not less than 25Kg] Complete with trolly.
3
-
-
Supply & Installation of fire sand buckets as directed by EIC
50
-
-
Supply & fixing of Industrial box type LED tube set including 2x20w (at least) LED tube to be fixed on the truss/wall inside the godown as per direction of the EIC . The lumenious efficiency of the fittings shall be 100/watt (atleast) or more surge protection 2KV(at least) . THD 10-20% p.f. should be 0.9 , IP 20 LM 79 & LM 80 to be submitted if required. Fittings should be fitted with GI bracket or equivalent of suitable diameter complete with making connection as required and mending good damages to wall including painting . Prior approval of the EIC is required before fixing of the fittings.
21
-
-
Supply & fixing of 45w LED(at least) street light fittings with IP66/IP65 protection to be fixed on the out side wall of the newly constructed godown as per direction of the EIC. The lumenious efficiency shall be 100/watt (at least) or more , surge protection 5KV . THD 10-20% ,p.f. should be 0.9 ,CRI 70, with lense peanut optics . LM 79 & LM80 to be submitted if required .The driver should be BIS certified and silicon filled potted used for vibration and short circuit proof This fittings should be held in place with suitable dia GI pipe bracket (Class B) fixed with minimum 3 nos MS clamp for external/internal light fittings. Complete withmaking connection as required and mending good damages to wall including painting. Prior approval of the EIC is required before fixing of the fittings.
18
-
-
Supply & fixing of Industrial box type LED tube set including 2x20w (at least) LED tube to be fixed on the wall inside the godown as per direction of the EIC . The lumenious efficiency of the fittings shall be 100/watt (atleast) or more surge protection 2KV(at least) . THD 10-20% p.f. should be 0.9 or more IP 20 LM 79 & LM 80 to be submitted if required. .Fittings should be fitted with suitable dia wooden block or equivalent of suitable diameter complete with making connection as required and mending good damages to wall including painting . Prior approval of the EIC is required before fixing of the fittings.
18
-
-
Supply & fixing of 150W(at least) LED flood light fittings to be fixed on the out side wall/pole of the newly constructed godown as per direction of the EIC. The l lumenious efficiency of the fittings shall be 100/watt (atleast) or more surge protection 10KV(at least) THD 10-20% , P.f. should be 0.9 or more IP66/IP65 protection , PDC aluminium housing ,extruded aluminium heatsink, with lense. LM79 & LM 80 to be submitted if required.This fittings should be held in place with suitable dia GI pipe bracket fixed with minimum 3 nos MS clamp or it should be fitted on the tublar pole as per direction of EIC for external/internal light fittings.complete with making connection as required and mending good damages to wall including painting. Prior approval of the EIC is required before fixing of the fittings.
5
-
-
Erection of single steel tubular pole of length as given below with sole plate and cap etc. In C.C. foundation (proportion and dimention indicated below) as to G.S. having 600x600x150 mm thick C.C.(4:2:1) base block sole plate/pole with hard jhama metal including C.C.(6:3:1) muffing 0.30mt(1'ft) dia and 0.30mt(1'ft) above ground lavel including 3mm(1/8") thick neat cemented finish and providing GI earth bolt after making drilled holes etc.On pole & carriage of pole upto 1.6KM from store depot to excavated site including filling up the excavated earth pit with shifted soil and ramming properly.Dimension of pole portion . Dimension of pole portion a) up to 9 mts(6:3:1) : 0.6x0.6x1.70 mt extra on this item for providing C.C. (6:2:1) base block (around the pole)dimension 0.6x0.6x0.76 mt above ground level neatly cementedfinish(3mm thick)at the base of pole(in lieu of C.C h muffing). Suitable for alkathene/polythene pipe entry as directed for street light wiring, including supply and fixing 25cmx25cmx10cm GI loop box , 16swg,and including drilled hole in pole. or as directed by EIC.
4
-
-
Supply & delivery of swaged type steel tubular poles(M.S. Painted) conforming to IS- 2713/1980 Length of the pole should be 7 mtrs (4.00 mtrs bottom+1.5mtrs middle + 1.5mtrs top), outer dia should be 114.3 +88.9+76.1,the thickness of the pole should be 3.65+3.25+3.25 respectively . Approx weightof the pole is 73Kg. It should be fixed with suitable size base plate in bottom, single srm bracket of 1.5mts length on top for mounting the lighting fixture.or as directed by EIC.It is also included on this item painting of steel tubular pole of length and no. of coats of coats of paint , as given below with ready mixed paint/primer of approved make and brand including preparation of surface by sand paper/emery paper, cleaning etc.for receiving fresh coat of paint. a) Up to 9 mtr long pole i) 1st coat of aluminium paint over 1 coat of RO primer ii) 2nd coat of aluminium paint over 1st coat.
4
-
-
Supply & fixing of PVC white round light cover 300mm dia(Minimum) for out door gate light complete with 23watt B22 cool white LED bulb complete fittings for erection purpose supply & fixing of suitable dia pipe , Loop box(connection box) complete with necessary arrangement & mending good damages to original finish. It is also included the Lettering over fittings as per direction of EIC.
2
-
-
Supply & fixing of 18" exhaust fan after making hole in wall and making good damages and smooth cement finish etc. It is also included louver and making necessary connection arrangements.
6
-
-
Connecting the equipments body to earth busbar including Supply & Fixing 25mmx6mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required & connection to equipments including drilling hholes, with bolts,nuts, washer etc.
60
-
-
Supply & fixing lighting conductor Air-terminals made of 15mm dia 1500mm long GI pipe having five prongs of 4 SWG GI (Hot dip) wire at top with 85mm dia 6mm GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1).
2
-
-
Hiring of DG set for testing overall electrical installation and also for use during the erection work , if required.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements