Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

West Bengal State Cooperative Marketing Federation Limited - BENFED Tender

Works
Civil Works Others
Eprocure
Opening Date7 Sep 2020
Closing Date28 Sep 2020
Tender Amount₹ 5,16,75,032 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity

23.62

-

54351

... More
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) Pakur Variety (1:3:6) In ground floor

196.8

-

4737

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision (ii) Grading-I Aggregate (63 mm to 45 mm) Using B. Manual Means Stone Screening Type B (11.2 mm)

196.8

-

3631.36

... More
(iii) Grading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm B. Manual Means

46

-

3661.98

... More
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in Charge. [Note: Subgrade CBR shouldnot be less than 5] (ii) Coloured Decorative

1800

-

1587

... More
GODOWN

-

-

-

... More
Earth work in excavation of foundation trenches or drains . In all sorts of soil (including mixed soil but excluding laterite or sandstone )including removing . Spreading or stacking the spils within a lead of 75 m . As directed . The item includes necessary trimming the sides of trenches. leveling. dressing and ramming the bottom . bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm

10.86

-

11927

... More
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm but not requiring shoring

3.44

-

19238

... More
Earth work in filling in foundation trenches or plinth with good earth. in layers not exceeding 150 mm . Including watering and ramming etc. layer by layer complete . (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

13.94

-

7754

... More
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity

9.13

-

71181

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand

1744.77

-

348

... More
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) Pakur Variety (1:3:6) In ground floor

188.14

-

4737

... More
Anti termite treatment to bottom surface ( in case of masonry foundation and basements) and the sides ( upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 6.2.1. of code IS-6313 (part -II) 1981.( Mode of measurment will be the plan area of foundation treated.)

1216.08

-

93

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture (b) M 25 Grade FOUNDATION

704.6

-

7241.79

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs .beams .columns.lintels curved or straight including fitting .fixing and striking out after completion of worka.(upto roof of ground floor) (c ) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work upto 1st fl

2338.59

-

359

... More
Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary ),cutting to requisite length . hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor /upto 4 m. (ì) Tor steel/Mild steel III. OTHER MANUFACTURERS NOT SPECIFIED Foundation UPTO 1ST floor ( gf roof)

105.69

-

70536.44

... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.

303.81

-

34

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (iii) 35 mm. thick

1254

-

324

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

1213.92

-

24

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

231.79

-

5198

... More
(b) In superstructure, ground floor

125.52

-

5420

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) gr floor

148.95

-

712

... More
Plaster (to wall,floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface. Including throating, nosing and drip course where necessary (¡) With 6:1 cement mortar (internal), 15mm plaster GR.FL

862.55

-

139

... More
(ii) With 1:4 cement mortar, ceiling, 10 mm thk GR. FLOOR

675.71

-

125

... More
(¡) With 6:1 cement mortar ( external) 20 mm. thick plaster gr floor

1246.4

-

159

... More
Labour for Chipping of concrete surface before taking up Plastering work.

675.71

-

21

... More
(a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. Ground Floor

30

-

3270

... More
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] GR FL

26.88

-

2199

... More
Supplying best Indian Sheet glass 5 mm thick including cutting to required sizes,setting on putty bases and fitted and fixed with teak glazing beads (19 mm x 12 mm) including putty and nails as necessary complete. (In all floors for internal wall & upto 6 m height for external wall)

26.88

-

948

... More
(vi) steel peg stay 300 mm long including fitting and fixing

56

-

25

... More
(v) Two point nose aluminium handle including fitting and fixing

56

-

40

... More
Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5mmx25mm). In ground floor (b) 25mm mesh at gr fl

26.88

-

378

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S.flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.

30

-

4330

... More
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof c) Span beyond 20 Mtr and up to 30 Mtr

52

-

77823

... More
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed 16mm bolt (b) 450 mm long

36

-

165

... More
(iv) 32 mm dia: (b) 500 mm long

48

-

508

... More
ROOFING AND SIDE SHEETING Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make(excluding the supporting frame work) fitted and fixed with55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). a) With 0.5 mm thick sheet

1329.36

-

896

... More
Galvanised corrugated iron sheet work (excluding thesupporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to be supplied by contractor (ii) In wall:- c) With 0.80 mm thick sheet

86.4

-

791

... More
Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping (B) 450 mm lapping each way (c) With 0.80 mm sheet

56.5

-

593

... More
Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping)

113

-

543

... More
Applying decorative cement based paint of approved quality after mpreparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification (iii) Two coats gr. Floor

1468.15

-

49

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (i) Internal surface (All floors) (b) Two coats i) Water based interior grade Acrylic Primer GR FL

14.68

-

4420

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC (a) TWO Coat GR.FL

12.46

-

4510

... More
Protective and Decorative Acrylic exterior emulsion paint of approvedN quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion GR FLOOR

1246.4

-

84

... More
a) Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces by sand papering etc.

2000

-

29

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary (b) On steel or other metal surface With super gloss (hi-gloss (iv) Two coats (with any shade except white)

2000

-

79

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match withGI Pipes as per IS : 1239 (Part -I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrewreducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately (a) For Exposed Work 200 mm

23.6

-

2703

... More
(D) Long Bend (90 Degree)

8

-

3179

... More
TOILET BLOCK & OFFICE

-

-

-

... More
Earth work in excavation of foundation trenches or drains . In all sorts of soil (including mixed soil but excluding laterite or sandstone )including removing . Spreading or stacking the spils within a lead of 75 m . As directed . The item includes necessary trimming the sides of trenches. leveling. dressing and ramming the bottom . bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm

0.49

-

11927

... More
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm but not requiring shoring

0.15

-

19238

... More
Earth work in filling in foundation trenches or plinth with good earth. in layers not exceeding 150 mm . Including watering and ramming etc. layer by layer complete . (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

0.49

-

7754

... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity DO BY FINE SAND

0.48

-

71181

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand

90.15

-

348

... More
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) Pakur Variety (1:3:6) In ground floor

7.44

-

4737

... More
Anti termite treatment to bottom surface ( in case of masonry foundation and basements) and the sides ( upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 6.2.1. of code IS-6313 (part -II) 1981.( Mode of measurment will be the plan area of foundation treated.)

36.43

-

93

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture (b) M 25 Grade FOUNDATION

40.2

-

7241.79

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs .beams .columns.lintels curved or straight including fitting .fixing and striking out after completion of worka.(upto roof of ground floor) (c ) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work FOUNDATION

122.51

-

359

... More
Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary ),cutting to requisite length . hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor /upto 4 m. (ì) Tor steel/Mild steel Foundation UPTO 1ST floor ( gf roof)

5.43

-

70536.44

... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.

27.84

-

34

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

90.15

-

24

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

5.5

-

5198

... More
(b) In superstructure, ground floor

21.73

-

5420

... More
c) at 1st floor

5.44

-

5531

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) gr floor

8.68

-

712

... More
Plaster (to wall,floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface. Including throating, nosing and drip course where necessary (¡) With 6:1 cement mortar (internal), 15mm plaster GR.FL

74.92

-

139

... More
1ST FL.

24.15

-

143

... More
(ii) With 1:4 cement mortar, ceiling, 10 mm thk GR. FLOOR

36.43

-

125

... More
(¡) With 6:1 cement mortar ( external) 20 mm. thick plaster gr floor

113.04

-

159

... More
1st floor

30.19

-

163

... More
Labour for Chipping of concrete surface before taking up Plastering work.

36.43

-

21

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals (c) Sal : Siliguri

0.15

-

87222

... More
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) (iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak

5.25

-

2789

... More
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] GR FL

4.68

-

2199

... More
Supplying best Indian Sheet glass 5 mm thick including cutting to required sizes,setting on putty bases and fitted and fixed with teak glazing beads (19 mm x 12 mm) including putty and nails as necessary complete. (In all floors for internal wall & upto 6 m height for external wall)

4.68

-

948

... More
(vi) steel peg stay 300 mm long including fitting and fixing

4

-

25

... More
(v) Two point nose aluminium handle including fitting and fixing

4

-

40

... More
Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5mmx25mm). In ground floor (b) 25mm mesh at gr fl

4.56

-

378

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile above 0.09 Sq.m

48.12

-

901

... More
WALL With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile above 0.09 Sq.m (i) Coloured decorative

51.4

-

1097

... More
Applying decorative cement based paint of approved quality after mpreparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification (iii) Two coats gr. Floor

111.35

-

49

... More
1st floor

24.15

-

56.1

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (i) Internal surface (All floors) (b) Two coats i) Water based interior grade Acrylic Primer GR FL

1.11

-

4420

... More
1ST FL

0.3

-

4420

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC (a) TWO Coat GR.FL

1.13

-

4510

... More
1st floor

0.3

-

4581

... More
Protective and Decorative Acrylic exterior emulsion paint of approvedN quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion GR FLOOR

113.04

-

84

... More
1ST FLOOR

30.19

-

91.1

... More
BOUNDARY WALL

-

-

-

... More
Earth work in excavation of foundation trenches or drains . In all sorts of soil (including mixed soil but excluding laterite or sandstone )including removing . Spreading or stacking the spils within a lead of 75 m . As directed . The item includes necessary trimming the sides of trenches. leveling. dressing and ramming the bottom . bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm

4.94

-

11927

... More
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm but not requiring shoring

0.58

-

19238

... More
Earth work in filling in foundation trenches or plinth with good earth. in layers not exceeding 150 mm . Including watering and ramming etc. layer by layer complete . (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

4.21

-

7754

... More
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) Pakur Variety (1:3:6) In ground floor

32.9

-

4737

... More
Batch Mixed Concrete of M30 grade with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture (b) M 30 Grade FOUNDATION

152.66

-

7241.79

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs .beams .columns.lintels curved or straight including fitting .fixing and striking out after completion of worka.(upto roof of ground floor) (c ) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work FOUNDATION

784.7

-

359

... More
Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary ),cutting to requisite length . hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor /upto 4 m (ì) Tor steel/Mild steel Foundation UPTO 1ST floor ( gf roof)

17.98

-

70536.44

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

98.44

-

5198

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) inground floor.

315

-

712

... More
Plaster (to wall,floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface. Including throating, nosing and drip course where necessary (¡) With 6:1 cement mortar (internal), 15mm plaster GR.FL

564

-

139

... More
(¡) With 6:1 cement mortar (internal), 20mm plaster

676.8

-

159

... More
Labour for Chipping of concrete surface before taking up Plastering work.

390.2

-

21

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor Ground Floor (ii) Grill weighing above 16 Kg./sq.mtr and above

15

-

9696

... More
Applying decorative cement based paint of approved quality after mpreparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification (iii) Two coats gr. Floor

564

-

49

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (i) Internal surface (All floors) (b) Two coats i) Water based interior grade Acrylic Primer GR FL

5.64

-

4420

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC (a) TWO Coat GR.FL

6.77

-

4510

... More
Protective and Decorative Acrylic exterior emulsion paint of approvedN quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion GR FLOOR

676.8

-

84

... More
a) Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces by sand papering etc.

56

-

29

... More
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. I) For structural members of specified sections weighing less than 22.5 Kg./m

3.37

-

72603

... More
Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T(Reinforced Barbed Tape) Concertina fencing on wall top usingconcertina coils stretched to approx.6 meters length at site clippedwith two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc

564

-

408

... More
SANITARY & PLUMBING

-

-

-

... More
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbow, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials. Payment for painting will be made separately) (A) For Exposed Work h (ii) 80 mm dia. medium quality

15

-

818

... More
g (ii) 65 mm dia. medium quality

15

-

665

... More
f (ii) 50 mm dia. medium quality

11

-

540

... More
e (ii) 40 mm dia. medium quality

25

-

415

... More
(ii) 32 mm dia. medium quality

30

-

355

... More
(B) For concealed work c) 25 mm. dia Medium Quality

20

-

364

... More
Labour for fitting and fixing G.I. specials including cost of jointing materials (b) Socket, Reducing socket, Bend, Plain equal elbow, Reducing elbow, Nipple, Short piece (iii) Above 50 mm upto 80 mm dia

30

-

11

... More
(ii) Above 25 mm upto 50 mm dia

66

-

10

... More
(i) Upto 25 mm dia

20

-

7

... More
(d) Cross, Union, Long screw (iii) Above 50 mm upto 80 mm dia

4

-

11

... More
(ii) Above 25 mm upto 50 mm dia

4

-

10

... More
(a) Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With ‘P’ trap

2

-

1421

... More
Supplying fitting and fixing 10 litre porcelain low down cistern of approved make with either side or bottom inlet, side over flow, brackets complete with all internal fittings i) white

2

-

2297

... More
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) Pakur Variety (1:3:6) In ground floor

4.5

-

4912

... More
Closet seat of approved make with lid & C.p. hinges, rubber buffer and brass screws supplied, fitted and fixed complete. i) Bestolite ( solid type ) White

2

-

715

... More
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete ii) C. P. Flush Pipe

2

-

295

... More
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. Brackets on 75 mm. x 75 mm wood blocks,C.P. waste fittings of 32 mm dia, one approved quality brass C.P. pillar cock of 15 mm dia, C.P. chain with rubber plug of 30 mm dia, approved quality P.V.C. waste pipe with C.P. nut 32 mm dia, 900 mm long approved quality P.V.C. connecton pipe with heavy brass C.P nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size

2

-

2208

... More
Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality) (a) Chromium plated Bottle trap 32 mm with 190 mm long connecting pipe and wall flange (Equivalent to Code No. 545 & Model - Tropical / Sumthing Special of ESSCO or similar brand

2

-

629

... More
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm (i) Recessed soap tray of size 150 mm X 150 mm

2

-

613

... More
Supplying, fitting and fixing porcelain soap tray of approved make (i) Recessed soap tray of size 150 mm X 150 mm

2

-

338

... More
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete (i) 635 mm X 395 mm X 420 mm

2

-

2869

... More
Supplying, fitting and fixing urinal flush pipe fittings of approved brand (c) C.P. urinal flush pipe fittings range of three

2

-

1248

... More
Supplying, fitting and fixing towel rail with two brackets. b) ALUMINIUM (iii) 25 mm dia. and 750 mm long

2

-

187

... More
Supplying, fitting and fixing 18 mm thick marble partition slab with chawk doongri marbel square cut, both sides polished with two front corners rounded and edges polished

2

-

1426

... More
Supplying,fitting &fixjng Half round channel with or without outlet as required set in cement concrete ( 6 ;3;1 ) with jhama chips complete (i) 600mmx100mm white vitreous chinaware

2

-

466

... More
H.C.I. bell mouth plain trap supplied, fitted and fixed with lead jointing complete 100 mm dia and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid separately).

2

-

845

... More
Supplying, fitting and fixing Aluminium domical grating i) 125 mm

8

-

56

... More
Supplying, fitting and fixing bib cock or stop cock C (ii) Chromium plated Bib Cock with wall flange (Equivalent to Code No. 5047 & Model - Florentine of Jaquar or similar brand).

8

-

861

... More
Supplying, fitting and fixing bib cock or stop cock (ii) Chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand

8

-

953

... More
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S.painting two coats to the exposed surface with approved paint complete (payment of painting will however be paid seperately ) b) 100 mm. dia

1

-

367

... More
Supplying, fitting and fixing peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg. sqcm.) (Note; item (i), (ii) and (III) to be done as per speciffic diirection of the Superintending,Engineer) vi) 32 mm.

4

-

1258

... More
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only) (ii) 80 mm dia

2

-

5591

... More
(iii) 65 mm dia

2

-

3929

... More
(iv) 50 mm dia

2

-

2277

... More
(v) 40 mm dia

4

-

1590

... More
Supplying PVC water storage tank of approved quality with closed top with lid (black-multi layer)4000 lt. capacity.

2

-

20821

... More
Labour for hoisting P.V.C water storage tank from G.L. to the roof 2500 lt. capacity. a) Upto 1st storey from G.L. (ii) Above 1500 litre upto 5000 litre capacity

2

-

154

... More
b)Labour for punching hole upto 50mm dia.

6

-

19

... More
Supplying, fitting and fixing approved brand P.V.C. Connector white flexible with both end coupling with heavy brass over C.P. nut 15 mm. dia. a) 750 mm. long

6

-

117

... More
Supplying, fitting and fixing approved brand 32mm P.V.C. waste pipe with coupling at one end fitted with neessory clamps. a) 750 mm. long

6

-

59

... More
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. ii) C. P. Flush Pipe

2

-

295

... More
Supplying, fitting and fixing self closing C.P. water tap of approved brand and make - 15 mm dia.

2

-

273

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately (a) For Exposed Work 100 mm

60

-

1134

... More
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials (i) 200 mm

300

-

2716

... More
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code (vi) For 100 users A) With Pakur variety. (SAIL/TATA/RINL)

2

-

108891

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia (SAIL/TATA/RINL)

2

-

16137

... More
Earth work in excavation of foundation trenches or drains . In all sorts of soil (including mixed soil but excluding laterite or sandstone )including removing . Spreading or stacking the spils within a lead of 75 m . As directed . The item includes necessary trimming the sides of trenches. leveling. dressing and ramming the bottom . bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm

0.2

-

11927

... More
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials i) With Pakur variety (Other than SAIL/TATA/RINL).

8

-

6987

... More
iii) Extra for each additional depth of 150 mm or part thereof beyond initial 600 mm depth.( 2 TIMES)

8

-

1238

... More
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only (i) 900 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 150 mm dia. of approved make A) With Pakur variety. (Other than SAIL/TATA/RINL)

2

-

11361

... More
ROAD

-

-

-

... More
Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary (a) Depth up to 150 mm.

1625

-

14.4

... More
(b) For each additional Depth of 150mm and part therof

1625

-

19

... More
Extra for manual compaction of earth by rammers / hand roller in 250 mm layers including watering etc. if required. (Borrow pit measurement

3250

-

20

... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity DO BY FINE SAND

4.81

-

71181

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision (ii) Grading-I Aggregate (63 mm to 45 mm) Using Stone Screening Type B (11.2 mm) B. Manual Means

112.5

-

3631.36

... More
(iii) Grading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm B. Manual Means

112.5

-

3661.98

... More
Supplying and laying brick Khoa of ordinary bats of size (38 mmx 63 mm)of approved quality in 100 mm layer (loose) filling in gaps with small ones rammed and compact as directed true to level and grade

1125

-

159

... More
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) (B) With N.B. Variety stone metal In ground floor

93.75

-

4737

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture (b) M 25 Grade

234.38

-

7241.79

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs .beams .columns.lintels curved or straight including fitting .fixing and striking out after completion of worka.(upto roof of ground floor) (c ) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work

146.88

-

359

... More
Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary ),cutting to requisite length . hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor /upto 4 m.

23

-

70536.44

... More
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (The rate is inclusive of cost of all materials, labour, hire and usage charges of machinery and all incidental charges in this connection.) A) Using Concrete Mixer

60

-

280

... More
Supplying and laying open mesh Jute Geotextile (JGT) for slope protection in road embankments, having overall weight of 500gm/m2, thickness 5 mm, width 1220 mm, strength 10 KN/m (in warp direction) and 7.5 KN/m (in weft direction) on slopes of embankments dressed and cut to a stable gradient, providing side lapping of 100 mm and horizontal lapping of 250 mm including cutting and anchoring trenches upto 150 mm depth at top and bottom of slope and refilling the same with excavated earth as per direction complete.

362.5

-

29.6

... More
Bituminous filler of approved type in expansion joints of dummy joints including finishing the top surface as directed

0.75

-

46603

... More
TUBE WELL

-

-

-

... More
Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. a) For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 metre). (i) First 50 metre

50

-

1014

... More
(ii) Next 50 metre

50

-

883

... More
(ii) Next 50 metre

50

-

1055

... More
(iv) Rest 50 metre

100

-

1091

... More
Supplying, fitting and fixing in position G.I.pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials, cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately)80 mm dia medium quality (ix) 150 mm dia. medium quality

100

-

1510

... More
(ix) 100 mm dia. medium quality

100

-

1006

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). 200 mm

50

-

2134

... More
Supplying G.I. pipe strainer with brass net & jacketted of approved quality. (iii) 80 mm dia

25

-

1875

... More
Supplying, fitting and fixing plug of approved make conforming to I.S. specifications.50mm dia

4

-

71

... More
Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm.50mm dia

4

-

2203

... More
Supplying, fitting and fixing heavy type bell mouth reducing socket.ii) 50 mm X 100 mm

4

-

455

... More
Supplying, fitting and fixing G.I. cap at top 100mm

4

-

139

... More
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.

3

-

7538

... More
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.

6

-

1231

... More
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.

2.2

-

2029

... More
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.

1

-

417

... More
Providing and fixing bell plug as required upto 250 mm (internal) dia. ERWMS pipe including cost of materials and labour complete.

3

-

431

... More
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.

3

-

2235

... More
Providing 200 mm centre guide.with clump

3

-

128

... More
Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.

4

-

8247

... More
Supplying KSB Submersible Pump and Motor Set (Model Cora 7C/10 5 H.P. Star Delta Starting, 440 Volts, having capacity: 7 m3/hr @ 48 mtrs head. It includes Copper Cable 1 X 3 X 1.5 SQ. MM and Control Panel DOL starting with all necessary fittings complete.

1

-

45000

... More
ELECTRICAL WORKS

-

-

-

... More
MCB DISTRIBUTION BOARD

-

-

-

... More
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.

-

-

-

... More
125A (Siemens or equivalent)

2

-

9370.2

... More
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment

-

-

-

... More
12 way (Legrand or equivalent)

2

-

14721

... More
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection

-

-

-

... More
125A (Legrand or equivalent)

2

-

8545.95

... More
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.

-

-

-

... More
2+8 way Enclosure (607711).

10

-

1550.85

... More
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment

-

-

-

... More
4 way Enclosure (607715).

10

-

2993.55

... More
MCB

-

-

-

... More
Supplying and fixing 240/415V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection

-

-

-

... More
6-32 A SP.

150

-

199.5

... More
6-32 A DP.

20

-

573.3

... More
32 A TP.

15

-

888.3

... More
32 A FP.

10

-

1255.8

... More
MCB ENCLOSURE

-

-

-

... More
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment

-

-

-

... More
2 Way.

5

-

283.5

... More
WIRING WITH PVC INSULATED & UNSHEATHED SINGLE CORE STRANDED COPPER WIRE ‘'FR' – IN PVC RIGID CONDUIT 'FR' (ISI MARKED) ON WALL/CEILING

-

-

-

... More
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required

-

-

-

... More
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC

200

-

107.1

... More
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC.

750

-

124.95

... More
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC.

300

-

156.45

... More
Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire ‘'FR' – in PVC Rigid Conduit 'FR' (ISI Marked) on wall/ceiling

-

-

-

... More
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.

-

-

-

... More
One light control by 1 switch

60

-

725.55

... More
Two light control by 1 switch

45

-

891.45

... More
Three light control by 1 switch

30

-

1057.35

... More
Supply & Fixing 240 V, 6/16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular typeswitch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

45

-

478.8

... More
1NO BLANK PLATE.(1M)

50

-

30

... More
Supplying,installation,testing and commissioning of = Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.

-

-

-

... More
1 output per phase and suitable for single phase supply

3

-

3657

... More
MV CABLE

-

-

-

... More
Supply of 1.1KV 4Cx6sqmm XLPE Armoured Al. cable as directed by EIC.

500

-

81.03

... More
Supply of 1.1KV 3.5Cx50sqmm XLPE Armoured Al. cable as directed by EIC.

200

-

225.17

... More
SCHEDULE OF RATES FOR LAYING OF XLPE/PVC INSULATED AND ARMOURED CABLES

-

-

-

... More
LAYING ON WALL / SURFACE WITH SADDLES / CLAMPS

-

-

-

... More
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting

450

-

63

... More
Laying through Underground Trech

-

-

-

... More
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed

150

-

180.6

... More
COMPRESSION GLAND

-

-

-

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :

-

-

-

... More
For 4 core - upto 6 sqmm.

25

-

120.75

... More
For 3.5 core - upto 50 sqmm

10

-

206.85

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :

-

-

-

... More
4 core 6 sqmm cable.

30

-

65.1

... More
3½ core 50 sqmm cable

10

-

219.45

... More
FINISHING COPPER WIRE ENDS

-

-

-

... More
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.

-

-

-

... More
2.5sqmm.

800

-

6.3

... More
4sqmm.

125

-

7.35

... More
SURFACE LUMINAIRE

-

-

-

... More
Supply of surface mounted LED light fixture with 2x20Watt LED Lamp.( CROMPTON-IGP162LT8-16 + LGT8-20-865-2 OR APPROVED BY EIC)

180

-

1262.8

... More
Supply of surface mounted LED light fixture with 1x20Watt LED Lamp.( CROMPTON-IGP161LT8-16 + LGT8-20-865-2 OR APPROVED BY EIC)

15

-

828.71

... More
Supply of wall mounted outdoor type 60watt LED Floodlight fixture. (CROMPTON- LFL-60-CDL/60-M OR APPROVED BY EIC)

20

-

4893.35

... More
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.

195

-

105

... More
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.

135

-

162.75

... More
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required

20

-

224.7

... More
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.

20

-

480.9

... More
EARTHING INSTALLATION – WITH PIPE ELECTRODE :

-

-

-

... More
Earthing with 50 mm dia GI pipe (TATA-Medium) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level (2Nos for Electrical equipment and 2nos for MS structure with shed).

10

-

1600.2

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.

10

-

960.75

... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.

10

-

557.55

... More
EARTH CONTINUTY CONDUCTOR:

-

-

-

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages

-

-

-

... More
No. 8 SWG

300

-

9.45

... More
EQUIPMENT EARTHING:

-

-

-

... More
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

125

-

144.9

... More
Add 12% G.S.T. + 1 % L.W.Cess

1

-

5993426.73



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.