West Bengal Medical Services Corporation Limited Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
West Bengal Medical Services Corporation Limited - WBMSC Tender
Civil And Construction
Building Construction
Eprocure
Opening Date6 Mar 2024
Closing Date28 May 2024
Tender AmountRefer Documents
Costs
EMD
₹ 90,480Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Repair And Renovation Of Ic Building (gplus4 Storied) Of Medinipur Medical College And Hospital In The District Of Paschim Medinipur-sitc Of Lifts
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBMSC_679959_1Bid Award Id
ViewTender No
WBMSCL/NIT-165/2024 Dated 05/03/2024Tender Authority
West Bengal Medical Services Corporation Limited ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Power Supply: 415 volts, 3 phase, 50Hz, AC
Auxiliary Power Supply: 220 volts, 1 phase, 50Hz, AC
Light: Square LED Light Inside the Car
Fan: Cross Flow Fan
Indicators: Car & Landings: Direction & Position Indicator Display
Audio System: Announcement of Car Position & provision to play song from inside the car
-
-
-
... More
Other Features: Battery Operated Emergency Light & Alarm Call Registration LEDs OSG Electronic Switch Full Length Infra Red Light Curtain Door Safety Fireman Drive Load Weight Device Rescue Device KDS300 Round push Button. Lift Announcement Systems Full Height COP inside the CAR Intercom Telephonic Systems Car Door Lock systems
-
-
-
... More
Supply installation testing & commissioning of New 15 Passenger-1020KG Elevator (G+4 = 5 STOPS) having the following basic features: (Make: Mitsubishi / OTIS / KONE / Schindler / TK Elevator )
1
-
-
... More
Type & Capacity: Passenger 15 Persons – 1020 Kg.
Speed: 1.50 Mtr/Sec
Drive: AC Variable Voltage Variable Frequency Drive with Microprocessor based Simplex Collective Control
Machine type & Location: MR - Gearless machine in machine room located directly above lift well. Travel considered: 17.5 mtrs. (Approx)
Serving: Ground Floor to 4th Floor ( G,1,2, 3, 4) 5 Stops, 5 Levels, 5 Openings
-
-
-
... More
Well Size: 2800 mm (W) X 1950 mm (D) or as per available well size
Car Size (Clear Inside) approx.: 1200 mm Wide x 1400 mm Deep x 2200 mm Height
Pit Depth: 1600 mm
Head Room: 4500 mm
Car Enclosure: SS Hairline + Silver Sky finish for front & back Panel and side panel with SS Honey ComB. Car door: 2 panel automatic center opening/side opening door with ACVF drive in Stainless steel
Landing door: 2 panel automatic center opening door in Stainless Steel Silver Sky finish
Handrail: Round handrail in Stainless Steel finish provided on rear wall of car
Stretcher Impact Protection: Yes
Car suspended ceiling: Stainless Steel Silver Sky finish with Square LED for car lighting & full metal body Cross Flow Fan for air circulation
Car Flooring: 20mm recess provided for granite/marble flooring (Shall be done by the OEM of Lift)
No. of Entrances: One Location – Front.
Car Entrance: Stainless steel Silver Sky finish with Frame
All Landings: Stainless steel Silver Sky finish with Frame
Clear Opening: 800 mm Wide x 2000 mm High / as per standard
Landing operating panel: Individual landing operating panel for each elevator
-
-
-
... More
Power Supply: 415 volts, 3 phase, 50Hz, AC
Auxiliary Power Supply: 220 volts, 1 phase, 50Hz, AC
Light: Square LED Light Inside the Car
Fan: Cross Flow Fan
Indicators: Car & Landings: Direction & Position Indicator Display
Audio System: Announcement of Car Position & provision to play song from inside the car
-
-
-
... More
Other Features: Battery Operated Emergency Light & Alarm Call Registration LEDs OSG Electronic Switch Full Length Infra Red Light Curtain Door Safety Fireman Drive Load Weight Device Rescue Device KDS300 Round push Button. Lift Announcement Systems Full Height COP inside the CAR Intercom Telephonic Systems Car Door Lock systems
-
-
-
... More
Additional Features: 1. ACVVVF closed loop drive
2. Alarm button in car operating panel with battery back-up
3. Automatic operation for car fan
4. Adjustable door open time
5. Anti-nuisance (empty car)
6. Anti-nuisance (car call cancellation at direction reversal)
7. Blower fan in car for ventilation
8. Braille on push buttons
9. Car call cancellation by double pressing floor button in car operation panel
10. Door open and door close buttons in car operating panel
11. Door closing retries
-
-
-
... More
12. Door nudging
13. Emergency light
14. Full load by-pass
15. Home landing
16. Infra-red screen for car door
17. Intercom
18. Jammed landing operating panel call button by-pass
19. Motor overheat protection
20. Overload function with audio-visual indication in car operating panel
21. Phase failure and phase reversal protection
22. Automatic rescue device in case of power failure
23. Attendant control
-
-
-
... More
24. Car arrival chime on car top
25. Red dot matrix scrolling display in car operating panel
26. Red dot matrix scrolling display in landing operating panel on All Floors
27. Fireman control
28. Fireman emergency return
29. BMS Compatibility
30. Independent operation (car VIP function)
31. Parking operation (key switch in landing operating panel) on main floor
32. Voice announcement unit in English language in car
33. RCC Socle for car and counter weight buffers
34. Auto light & fan switch OFF (POD)
35. 3-YEARS WARRANTY FROM THE DATE OF HANDING OVER
-
-
-
... More
Scope of Work:
1. Supply installation, testing and commissioning of elevators at site as listed under Technical Specifications.
2. Material transportation, marine/inland Insurance, unloading of material at site
3. Obtaining Lift License (including all associated fees and expenses).
4. Site security (including security of partial, ongoing and Completed Work)
5. Store security (including on-site/off-site stores and stored Materials/Products within or outside storage area)
6. Provision and availability of safe, dry, weather-proof, lockable store (with sufficient lighting and two numbers three pin plug points) consisting of minimum 50 sqm area per elevator near the elevator shaft on ground or basement floor, for entire installation period.
7. Shifting of Materials/Products within the site (including shifting from existing store to another store or location on client’s request) except for the purpose of Installation of Products.
-
-
-
... More
8. Provision of elevator shaft & pit/ escalator pit duly plastered, white washed, waterproofed, clean/ clear elevator pit/escalator pit, with shaft/pit dimensions as per approved General Arrangement Drawings (“GAD”) and within tolerance level and complete in all aspects without any further need of modification/rectification of shaft, pit, overhead, and entrance wall etc.
9. Provision of electrical power supply, including 230 V Single phase, 5A socket and 415 V three phase 50 HZ AC with earth leakage circuit breaker (ELCB) of required capacity as per GAD within 5 meters of each elevator/ escalator controller for installation, testing and commissioning, Effective double earthing from a separate (independent from other power equipment) earth pit exclusively for elevator(s)/escalator(s) Lightning arrestor and other electrical protective devices necessary to meet local regulatory/statutory requirement. Shaft lighting should be independent of main switch provided for control board.
-
-
-
... More
10. Supply and erection of suitable scaffolding (as per approved GAD) inside elevator shaft/escalator pit for entire installation period and dismantling/removal of the same after completion of Works.
Note: If in company’s’ scope, scaffolding shall be used for elevator installation works only and not for shaft preparation works etc. Also, the company may use scaffoldless method for installation works, at its own discretion.
11. Provision of minor builders’ works (details as per GAD)
12. Provision of dry and clean machine room with provision of cross ventilation (through exhaust fan), sufficient machine room lighting, lockable door (2m x 1m, outside opening type), with provision of rain protection guard on doors and windows, direct approach from terrace to machine room by a stairs or through rigid ladder with handrails and fall protection rails, trap door cover, fire extinguisher, smoke vent of suitable size in shaft covered with wire mesh.
-
-
-
... More
13. Provision and fixing of support structures, hoisting beam/ hook fixed in the roof slab of the machine room, as required. 14a. Provision and fixing of separator channels for common shaft, if required.
14. Provision and fixing of screen between two adjacent shafts and or glass for glass shafts, if required.
15. Provision and maintenance of adequate light points/ lighting and lux level inside elevator shaft (including at each landing, machine room and the elevator pit)/ escalator pit.
16. Provision and availability of Flooring inside elevator car/cabin.
17. Supply of shaft reduction channels.
18. Installation of shaft reduction channels.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements