West Bengal Electronics Industry Development Corporation Limited Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
West Bengal Electronics Industry Development Corporation Limited - WEBEL Tender
Software and IT Solutions
Eprocure
Opening Date20 Jun 2024
Closing Date5 Jul 2024
Tender AmountRefer Documents
Costs
EMD
₹ 35,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Webel/eot/com/23-24/00099r(2nd Call)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WEBEL_697285_1Bid Award Id
ViewTender No
WEBEL/EOT/COM/23-24/00099R(2nd Call)Tender Authority
West Bengal Electronics Industry Development Corporation Limited ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Request for Proposal for setting up of IT infrastructure works at STP-II building for office setup of Directorate of Registration and Stamp Revenue, GoWB
BOQ Items
... More
PART-B: Data (LAN & WiFi) Networking- SITC of Layer 2, PoE enabled, with PD: minimum 370 Watt (should have minimum 15.4 Watt per Port), fully managed, 1RU, GE Switch to be operated on 200-240VAC, 50 Hz Supply, with perpetual license of OEM, having minimum technical specification:
a) 24 x 10/100/1000Base-T Mbps PoE enabled host ports (Minimum); b) 2 x 1GE SFP+ port; c) Forwarding performance/stacking bandwidth/ backplane speed (Minimum) of 95.2Mpps; d) Fanless operation with operating temperature up to 45°C; e) DRAM and Flash RAM as per OEM; f) Software support with IPv4 routing (542 routes), multicast routing (IGMP) including necessary software license; g) Minimum switching capacity of 216Gbps; h) Number of VLAN Supported: 64 (Minimum).; i) Total number of MAC Address: 8,000 (Minimum); Including Centralised VMS Software. Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
1
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of Layer 2, Switch 1RU, GE Switch to be operated on 200-240VAC, 50 Hz Supply, with perpetual license of OEM, having minimum technical specification:
a) 24 x 10/100/1000Base-T Mbps ; b) 2 x 1GE SFP+ port; c) Forwarding performance/stacking bandwidth/ backplane speed (Minimum) of 95.2Mpps; d) Fanless operation with operating temperature up to 45°C; e) DRAM and Flash RAM as per OEM; f) Software support with IPv4 routing (542 routes), multicast routing (IGMP) including necessary software license; g) Minimum switching capacity of 216Gbps; h) Number of VLAN Supported: 64 (Minimum).; i) Total number of MAC Address: 8,000 (Minimum); Including Centralised VMS Software. Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
1
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of Dual Band Wireless Access Point 802.3ax GIGABIT.
Dual-band radios; supports 256-QAM 2X2 MIMO with 2 Spatial Streams; 20, 40, and 80 MHz Channels; 1.488 Gbps data rates on dual concurrent radio operations; Packet Aggregation (AMSDU, AMPDU); Reduced Interface Spacing; Layer 2 and Layer 3 Layer 3 routing, 802.1q, DynDNS, DHCP server/client, BOOTP client, PPPoE and LLDP; Security: Stateful Firewall, IP filtering, NAT, 802.1ax, 802.11i, WPA2, WPA TripleMethodology Rogue Detection: 24x7 dual-band WIPS sensing, on-board; IDS, and secure guest access (hotspot); Quality of Service (QoS) WMM, WMM-UAPSD, 802.1p, Diffserv, and TOS; Operating Channels: 2.4 GHz band: channel 1 through channel 13, 5.2 GHz band: channel 36 through channel 165. Including Centralised VMS Software.
Licence: 03(Three) Years subscription with 24x7 Comprehensive on-site support for 03(Three) Years.
3
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of Networking Horizontal unArmoured Cable, 1000Base-T (Gigabit Ethernet), 100Base-T (Fast Ethernet), 10Base-T (Ethernet), 1-500 MHz (Minimum), Category 6A, 4-Pair, F/UTP, 23 AWG solid bare copper conductors with FEP insulation, polyester separator, overall shield, Flame arrest jacket LSZH OUTER sheath COVERas to standard of ISO/IEC 11801Ed. 2.0, EN 50173-1 and TIA/EIA 568C.
Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
10
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of CAT 6 Information Outlet die-cast Jack with dust cover, 180° cable exit faceplate & backbox Make: Belden,Comscope,Panduit, Siemon
Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
3660
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of CAT 6 F/UTP 24 Port Modular fully loaded patch Panel ISO 11801 AMD 1 Class EA TIA-568-C.2 Cat 6 ANSI/EIA-1069-A IEC 606037
Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
84
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of PATCH CHORD Category 6 4-Pair, SF/UTP, Horizontal cable, 23 AWG solid bare copper conductors WITH RJ45 CONNECTOR AT BOTH END 1 MTR LENGTH Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
4
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of PATCH CHORD Category 6 4-Pair, SF/UTP, Horizontal cable, 23 AWG solid bare copper conductors WITH RJ45 CONNECTOR AT BOTH END 2 MTR LENGTH
Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
84
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of Floor Mounted Cross Connect Equipments Network Rack
42U x 600 x 800 Rack - Front Glass Door with Cam Lock - Fan Unit of 360CFM(Min) / 230 Volt - 4no - 6; Way 5A PDU, along with input Cable - 2no - H/w Packet of 20 - 8no - 1U PVC Cable Manager - 6no. Warrenty: 03 (Three) Years onsite comprehensive OEM warranty with parts and service.
84
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of 10Gb Duplex Multi mode 50/125 OM3 LSZH Armoured Fiber Patch Cable, SC-SC/ SC-LC/ LC-LC as per sites requirements - 3 MTR
Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
1
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of 10G Base SR Multi Mode modular and field replaceable SFP module of same rating of Ethernet Switch & OEM
Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
6
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of Network Security Firewall having minimum technical specification of Hardware & Software:
IPS Throughput: 1.4 Gbps or higher; NGFW Throughput :1 Gbps or higher; Threat Protection Throughput: 900 Mbps or higher; Firewall Throughput: 10 Gbps or higher; IPsec VPN Throughput: 6.5 Gbps or higher; Firewall Latency: 3.3 μs or better; Concurrent Sessions (TCP): 1.5 Million; New Sessions/Second (TCP): 45,000; Firewall Policies: 5,000; Application Control Throughput (HTTP 64K): 1.8 Gbps; Gateway-to-Gateway IPsec VPN Tunnels: 2,000; Client-to-Gateway IPsec VPN Tunnels: 50,000; SSL-VPN Throughput: 900 Mbps; Concurrent SSL-VPN Users: 5,000; SSL Inspection Throughput: 630 Mbps; SSL Inspection CPS: 4,000; SSL Inspection Concurrent Session: 300,000; Application Control Throughput: 12 Gbps; CAPWAP Throughput: 14.8 Gbps; Virtual Domains (Default/Max): 10/10; Maximum Number of Switches: 72 Maximum Number of APs (Total / Tunnel): 512 / 256; Maximum Number of Tokens: 5,000; High Availability Configurations: Active-Active, Active-Passive, Clustering; Interfaces and Modules: 1x CPUs, 2 x physical cores, 4 virtual cores; 6x 10/100/1000Base-T RJ45 port card; ; IPv6 Ready: Yes; Compliance: FCC Part 15 Class A, RCM, VCCI, CE, UL/cUL, CB; Certifications: ICSA Labs: Firewall, IPsec, IPS, Antivirus, SSL-VPN; USGv6/IPv6; Details of the Firewall Policies for the Firewall provided with the License: UTM Protection (24x7 Care plus Application Control, with Security Gateway Feature of Firewall, Identity Awareness, IPsec VPN, Advanced Networking & Clustering, Mobile Access, IPS, Application Control, Content Awareness, URL Filtering, Antivirus, Anti-Spam, Anti-Bot, SandBlast Threat Emulation, SandBlast Threat Extraction, Network Policy Management, Logging & Status, Web Filtering and Antispam and Sandbox Cloud) including all necessary accessories as per site requrement.
Licence: 03(Three) Years Advanced Bundle (24x7 Care plus Application Control, with Security Gateway Feature of Firewall, Identity Awareness, IPsec VPN, Advanced Networking & Clustering, Mobile Access, IPS, Application Control, Content Awareness, URL Filtering, Antivirus, Anti-Spam, Anti-Bot, SandBlast Threat Emulation, SandBlast Threat Extraction, Network Policy Management, Logging & Status, Web Filtering and Antispam and Sandbox Cloud) subscription with Comprehensive on-site support for 03(Three) Years.
6
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC: 20kVA (2 x 20 kVA) Online Modular UPS (3-ph input, 3-ph output) System with 62400 VAH (Min) Back-up Battery, Rack, Links, Cables & Other Accessories having minimum technical specification:
Capacity (in kVA / kW): 20 kVA 3-Phase Input / 3-Phase Output Digital Signal Processing (DSP) controlled IGBT based technology true On-line, Load Sharing Mode (1+1) configuration enabled. Each Module of 20KVA. Nominal Input Voltage: 380 / 400 / 415V AC; Input Voltage Range: 300 - 477 V AC (On Full Load), 210 - 477 V AC (On 70% Load); Nominal Input Frequency: 50 / 60 Hz (Auto selectable); Input Frequency Range: 45 to 55 Hz; Input Power Factor: 0.99 on Full resistive load; Input Current Harmonic Distortion (THDi): 5 % on Full Load (with Mains THDu less than 1%); Generator Compatibility: Compatibility to genset supply required; Input Protection (Thru In-built 3P MCCB: Input to Rectifier, Input to Bypass, Manual Bypass (In-built); Nominal Output Voltage: 380 / 400 / 415V AC (Selectable); Output Voltage Regulation: +/- 1%; Nominal Output Frequency: 50 / 60 Hz (Selectable); power factor: 0.9PF (full load), Output Frequency Regulation: +/- 0.05 Hz (Free Running / Self Clocked Mode), + / - 5 % (Synchronized to Mains Mode, Selectable); Output Voltage Distortion (THDu): = 3% (For 100% Linear / Resistive Load), = 5% (For 100% Non- Linear / RCD Load); Operating Temperature: 0 to 40 deg C; Operating Humidity: 0 to 90% RH (Non-condensing); Protection Class: IP – 20; Noise Level: 75 dbA at I meter distance; Reliability: MTBF greater than 100000 hours; Certification (Manufacturer): QMS: As per ISO 9001: 2008; EMS: As per ISO 14001: 2004; OSHAS: As per ISO 18001: 2007; Product: Safety: As per EN62040-1-2; EMC: As per EN62040-2; ESD: As per
IEC61000-4-2 Level 4; RF: As per IEC61000-4-3 Level 3; FT/Burst: As per IEC61000-4-4 Level 4; Surge: As per IEC61000-4-5 Level 4; CE: Declaration of Conformance;
A single Modular UPS Chassis (minimum 80kVA) with minimum 4no of bay and must have 02(two) no vacant bay of same UPS rating with all accessories. Separate Battery bank with all necessary accessories. Including Battery Rack, Inbuilt Transformer Less Isolation, SNMP Card with Preputial licence for remote monitoring, Automatic Changeover Switch or UPS parallel kit, Wire, etc & all necessary Earthing arrangement.
40kVA (2 x 20 kVA) 3Ø/3Ø (Phase input/output) with 62400 VAH (2 x 31200 VAH) (Min) Battery Backup or equivalent VAH or Higher, DC BUSBAR VOLTAGE ±480 or higher; 12V SMF Battery, with MS-Rack, Interlink Nyvin Cable, Connector, Special battery terminal insulation cover, Battery isolation DC MCB and other accessories. Warranty: 03(Three) years on UPS & 03(Three) years on Battery onsite warranty with parts and service except force majeure.
1
-
-
... More
PART-B: Data (LAN & WiFi) Networking SITC of UPS Point for Server Room, Conference Room and Workstation with Cable, Switch Board, MCB DB as required
90
-
-