West Bengal Electronics Industry Development Corporation Limited Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
West Bengal Electronics Industry Development Corporation Limited - WEBEL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Nov 2023
Closing Date9 Jan 2024
Tender Amount₹ 9,35,000
Costs
EMD
₹ 18,700Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ec 07 Stp Ii Civil Maint 2nd Call 23 24 056
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_WEBEL_609290_1Bid Award Id
ViewTender No
EC/07/STP II/ Civil maint/2nd call/23-24/056Tender Authority
West Bengal Electronics Industry Development Corporation Limited ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Taking out and refixing SS plates from column facia with new screws to the MS structural framework ,adjusting, welding, cleaning, cutting holes, mending good damage to match with the existing one complete with all screws, welding etc.
90
-
-
Hire and labour charges for high scaffolding all round (outside) for repairing of column facia
1
-
-
Labour for taking out lowering and stacking after dismantling in parts R.S. joists, channels, angles, tees, plates, ladders etc.complete as directed.
-
-
-
From 1st floor level
4
-
-
Extra for each addl. Floor
7
-
-
Supply, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps/ nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) and taking out of old CI pipes complete. Dia 160 mm
24
-
-
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
150
-
-
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
100
-
-
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar
including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (all floor)
-
-
-
With 1:4 cement mortar, 15 mm thick plaster
150
-
-
With 1:4 cement mortar, 20 mm thick plaster
200
-
-
Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving putty/ primer. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge), all floors (make: Dulux/ Asian Paints)
250
-
-
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
200
-
-
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (all Floors)
One Coat, Water based interior grade Acrylic Primer
300
-
-
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :
(Two coats), standard quality
300
-
-
Supply, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design (for drawers and tables) and as per approval and direction of Engineer-in- Charge.
All floor (Century/ Greenply), 16mm
20
-
-
Supply, fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof.
all floor
Glossy/Matt/Suede excluding surface texture or metallic lustre.
Thickness of laminate 1.5mm (century/ Greenply)
25
-
-
Supplying, fitting and fixing Godrej Multi Lock or equivallent for drawer
20
-
-
Taking out existing partition/ceiling of particle board, masonite board, ply board, soft board, laminate etc. of any thickness and mending damages if any.
25
-
-
Labour for taking out rolling shutter (only shutter portion)
dismantling by parts for repair or (replacement of damaged parts only), rehanging and refitting the same in position after necessary repairs (excluding the cost of supply of new parts).
70
-
-
Renewing seam pipe for rolling shutter as per existing size and
shape fitting, fixing complete.
25
-
-
Renewing side split pin for seam pipe for rolling shutter.
14
-
-
Oiling and greasing of rolling shutter and repair to in side lock.
70
-
-
Renewing spring of rolling shutter as per existing size and shape including fitting fixing complete.
14
-
-
Easing and oiling, cleaning rolling shutters including repair to
inside locks.
70
-
-
1st class brickwork of width 200 mm. with non-modular bricks in cement and sand mortar (1:4)
-
-
-
(a) In foundation and plinth
1.5
-
-
(b) In superstructure ground floor
12
-
-
Asbestos corrugated (Trafford or similar approved quality) sheet (6 mm thick) work (excluding the supporting framework) fitted and fixed with 9.5mm. dia. J or L hook-bolt and nuts, limpet and bitumen washers and putty with 150 mm end lap & one corrugation minimum side lap complete.
(Payment should be made on area of finished work), in roof
25
-
-
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.
In ground floor including roof.
6
-
-
Dismantling carefully wooden walling, flooring or false ceiling and stacking dismantled materials as directed.
70
-
-
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Standard Ceiling Board (Density 1300 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge.
In ground floor
False Ceiling (with 4mm thick Fibre Cement Standard Ceiling Board and EGrid T-2430/1510).
70
-
-
Supplying & laying of approved brand of scratch proof, semi flexible P.V.C. blended homogeneous marble Vinyle flooring in tiles conforming to IS:3461, fixing with synthetic acrylic adhesive after preparing the floor, levelling & smothaning when necessary with suitable putty, as per the design & instruction of the Engineer-in-charge.
2 mm thick
12
-
-
Supply, fitting and fixing chekered plate of thickness 5 mm, fitted in M.S. angle (25 x25 x5 mm) frame and two handles made of 12 mm M.S. round bars for pit covers etc as per drawing & direction of EIC.. All welding spots should be properly filed or rounded smooth including cost of welding rods, two coats of red oxide paint and two coats of synthetic emulsion paint, labour complete with all other incidental costs.
160
-
-
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in all floors as per relevant IS codes
Pakur Variety
5
-
-
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in all floors as per relevant IS codes (in thin sections only upto thickness 65 mm)
Pakur Variety
4
-
-
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (all floors)
25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
50
-
-
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.
all floors, Other than
SAIL/ TATA/RINL
0.4
-
-
Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately)
Above area 2.5 Sq.m
120
-
-
Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete.
Heavy type (I.S.I. size 3)
10
-
-
Supplying heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge.
10
-
-
Supplying heavy duty top pin/set of pivots of local make and approved by the Engineer-in-charge. (This item to be provided where floor spring not used).
20
-
-
Supplying Zinc powered coated star lock
20
-
-
Supplying, fitting and fixing aluminium door lock
20
-
-
Supplying PVC rollers for sliding windows as per direction of Engineer in charge.
40
-
-
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:-
Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers.
Fixed glazing.
12
-
-
Supplying bubble free float glass of approved make and brand
conforming to IS: 2835-1987. 4mm thick clear glass.
20
-
-
Supplying profiles of required section made of Aluminium Alloy
Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). In 10-12 Micron thickness Annodizing film, natural white, Fixed glazing.
-
-
-
Top, bottom and side member.
30
-
-
Mullion.
15
-
-
Glazing clip.
60
-
-
Suuply, fitting & fixing single skin, colour coated trapezoidal profile for wall cladding, roof shall be made of 0.45 mm BMT (base metal thickness), 0.5 mm TCT (total coated thickness excluding paint, G550 (min 550 yield strength), of Zincalume metallic coating (IS 15965) with high solar reflectance index (SRI) value for better coiling as per thermatech technology, 1000-1500 mm effective cover width with five major corrugation, 28 mm high rib spaced at 203 mm c/c with subtle square flunting in the pan and the end rib shall have anti capillary groove and return leg. The sheet shall be fastened with 40 micron zinc coated or 25 micron zinc-tin alloy coated, hex head, self-drilling screw as per IS 3566-2002 Class 3 fastener. The base steel shall be coated with Zinc- aluminium alloy Zincalume (AZ 150), i.e, 55% Al, 43.4% Zinc, 1.6% Si, minimum of 150g/sq cm coating total on both sides, pre painted with colorbond XRW (exterior roofing, walling) paint system of 35 micron super durable polyester paint (SDP) with stable inorganic pigment with no lead contents conforming IS15965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheets at regular interval confirming genuity of the material complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work, laps not payable).
Brand: TATA, colour: Blue, all floors
30
-
-
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary
On steel or other metal surface :
With other than hi-gloss of approved quality
Two coats (with any shade except white)
250
-
-
Painting with ready mixed red lead paint of approved make and brand including scraping of old layer of paint and rust : One coat
250
-
-
M.S. door as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
at all floors
1.2
-
-
Supplying fitting and fixing door frame with M.S. angle (50 mm x 50 mm x 8 mm) as per drawing & direction of required section.The holes for counter sunk machine screw & nuts will be such as to fit 8 to 10 mm Iron screw. The counter sunk nut to be welded . The nuts are to be welded after careful checking with screw.All welding spots should be properly filed or rounded smooth including cost of welding hinges for hinge cleats , lugs for hasp bolt, socket bolt etc. and necessary M.S. clamps of 25mm x 6mm flat 225mm long as per direction welded to the frame fitted and fixed in position excluding cost of concrete
50
-
-
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).
-
-
-
100 mm dia
2
-
-
50 mm dia
2
-
-
32 mm dia
4
-
-
25 mm dia
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements