Water Resources Development Directorate Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Civil And Construction
Irrigation Work
Eprocure
Opening Date29 Mar 2025
Closing Date19 Apr 2025
Tender Amount₹ 25,64,134.6 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Coupler(Cl-II) for 140 mm. dia P.V.C. pipe ( extra) I.S. 10124/2009, Part- II with free solvent cement.

11

130

1430

... More
Coupler(Cl-II) for 110 mm. dia P.V.C. pipe ( extra) I.S. 10124/2009, Part- II with free solvent cement.

50

67

3350

... More
110x110x 110 mm. P.V.C. Tee (Part-V) with free solvent cement,I.S. 10124/2009 (Cl-II)

9

347

3123

... More
140x140x 140 mm. P.V.C. Tee (Part-V) with free solvent cement,I.S. 10124/2009 (Cl-II)

3

712

2136

... More
140 x 110 mm Reducer(cl-II) with free solvent cement,I.S. 10124/2009

4

283

1132

... More
140 mm. dia 900 bend (cl-II) ( IS. No. 10124/ 2009 Part- 8 with latest amendment ),with free solvent cement.

2

647

1294

... More
110 mm. dia 600 bend(cl-II) ( IS. No. 10124/ 2009 Part- 8 with latest amendment ) with free solvent cement.

6

378

2268

... More
110 mm. dia 900 bend(cl-II) ( IS. No. 10124/ 2009 Part- 8 with latest amendment ) with free solvent cement.

13

378

4914

... More
140 mm. dia IS. NO. 10124/ 2009 Part- 4 with latest amendment End cap (Cl-III) with free solvent cement.

1

330

330

... More
110 mm.dia IS.NO.10124/2009 Part-4 with latest amendment.PVC End Cap.(Cl-III) with free solvent cement.

2

230

460

... More
110 mm. dia ( IS. No 10124/2009 Part- 6 with latest amendment) F.T.P.(Cl-II) with free solvent cement.

9

310

2790

... More
140 mm. dia ( IS. No 10124/2009 Part- 6 with latest amendment) F.T.P.(Cl-II) with free solvent cement.

2

462

924

... More
Solvent cement extra (Medium duty)

3

425

1275

... More
MS/G.I Accessories G.I. Tripod set and Inlet & outlet Pipe Fittings as per drawing and Specification

1

202000

202000

... More
150 mm dia G.I E.R.W. Flanged Pipe with flange as per IS 1239 (Part-I)/2004 & 6392/1971, table 17 Specification. ISI MARKED

48

3800

182400

... More
100 mm dia G.I E.R.W. Flanged Pipe with flange as per IS 1239 (Part-I)/2004 & 6392/1971, table 17 Specification.ISI MARKED

24

2474

59376

... More
150 mm dia 90° G.I. bend both end flanged as per IS 1239 (Part-II)/2011, Galv-IS 4736-1986 with latest ammendments. ISI MARKED

4

8175

32700

... More
150 mm. dia I.S.I. 14846/2000 Amd No. 1&2 mark ISI mark and specification PN- 1.6 sluice valve .

2

9950

19900

... More
100 mm dia C.I. Sluice Valve I.S.I. 14846/2000 Amd No. 1&2 mark and specification PN- 1.6 sluice valve .

2

6300

12600

... More
100 mm dia NTP /Alfa-Alfa Valve as per technical specification

9

3300

29700

... More
80X65mm M.S. flanged reducer (Flange having ISI Marked)

2

1381

2762

... More
100X80mm M.S. flanged reducer (Flange having ISI Marked)

4

1633

6532

... More
M.S Foundation Bolt for Pump Motor sets manufactured from 20 mm nominal diameter M.S Rod as per IS 2026/1992. Total length of bolts is 275+10 mm in length & 20 mm in nomonal diameter with Nuts & 2 nos washer,the average weight of such bolt 1.1 kg per bolt with tolerance in weight of each bolt @ +/-10%

8

223

1784

... More
Foundation Bolt, For Distrubution Chamber Quadruped (1.1 Kg each) manufactured from 20 mm nominal dia MS rod as per IS 2062/2002.Total length of the bolt is 375+_ 10mm having welded head 80+- 10 mm in length and 20 mm nominal dia with Nut & 2 Nos. Washer.

14

223

3122

... More
M.S. Hexagonal Head Bolts & Nuts conforming to IS-1363 (Part-I) 1992 product grade - C with latest ammedments for boths IS-1363 (Part-3) / 2002 of product grade C with latest amount for nuts properties / class for bolt 4.62 nuts for 4.5. ISI Marked. M-20 X 80 mm

45

176

7920

... More
M-20 X 100 mm

8

176

1408

... More
M-16 X 65 mm

38

176

6688

... More
M-16 X 80 mm

10

176

1760

... More
M-16 X 50 mm

16

176

2816

... More
Foot valve leather washer 100mm dia,

2

234

468

... More
Compresed Asbestos fibre jointing for Quadruped & Tripod set( for raised surface of Flange as per IS-6392) 300mm.dia(Table-5)

2

1018

2036

... More
Rubber Insertion I.S. 638/1979 with latest amendment sheet 5 mm. 2 Ply. ( for raised surface of Flange as per IS-6392) i) 150 m dia Ruber Insertion(Table-17)

18

166

2988

... More
ii) 150 m dia Ruber Insertion(Table-5)

8

166

1328

... More
iii) 100 m dia Ruber Insertion(Table-17)

21

129

2709

... More
iv) 80 m dia Ruber Insertion (Table-17)

11

95

1045

... More
Electrical Accessories (ii) 3CX4sqmm copper cable conforming to IS 694 [Busbar to 21A, TP Main switch to Motor starter]

3

239

717

... More
(iii) 2X3CX2.5 sqmm copper cable conforming to IS 694 in 25 mm GI conduit (ISI-Medium quality) [Star-Delta Motor starter to Motor]

10

326

3260

... More
Laying of WTA: Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing or pumping out water etc as required complete. (a) Depth of excavation not exceeding 1500 mm. i) For Foundation Blocks of Tripod

2.61

119

311.29

... More
ii) For spout chambers

6.14

119

732.08

... More
Earthwork in excavation of field trenches as per designed section & alignment for laying of pipe lines(PVC,RCC,ACP etc.) upto a depth of 1500 mm in all sorts of soil including removing, spreading or stacking extra earth as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom as required complete.

903.6

99

89465.44

... More
Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) or plinth with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work)

888.33

66

58638.66

... More
Laying of UPVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittigs and solvent cement to be supplied by deptt.) all complete asper direction of Engineer-In- charge. 140 mm.OD.

252

10

2555.28

... More
110 mm. OD.

1200

8

10464

... More
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. i) For Foundation Blocks of Tripod

3.48

361

1256.28

... More
ii) For Spouts Chambers

37.25

361

13447.25

... More
Filling in foundation or plinth by Silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity) i) For Foundation Blocks of Tripod

0.26

936

243.41

... More
ii) For spout chambers

4.67

936

4372.1

... More
Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips (20 mm. normal size) excluding shuttering and reinforcement, if any, in ground floor. as per relevent IS Code. a) Pakur Variety i) For Foundation Blocks of Tripod

0.52

6055

3148.82

... More
Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevent IS codes.Pakur Variety i) For Fpimdatopm Blocks of Tripod

1.03

5548

5725.85

... More
ii) For Spout Chambers

3.14

5548

17421.66

... More
iii) Drop Wall

0.58

5548

3218.01

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (When the height of a particular floor is more than 4m. the equivalent floor ht. shall be allowed under 16 (c) for every 4 m. or part thereof.) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-in-charge. i) For Foundation Blocks of Tripod

5.28

335

1768.8

... More
For Spout

7.97

335

2669.95

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild Steel i) For Foundation Blocks of Tripod

0.04

55066

2257.72

... More
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete in foundation and plinth. (a) In foundation & plinth

7.9

5413

42762.7

... More
125 mm. thick brickwork with 1st class bricks in cement mortar (1 : 4) in ground floor including, saffolding, racking out joints etc. complete.

10.8

736

7948.8

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints, including throating, nosing and drip course, scaffolding/staging where necessary (ground floor) excluding cost of chipping over concrete surface. (ii) with (1:6) cement mortar, (b) 15 mm. thick plaster

56.34

151

8507.34

... More
(iii) with (1:6) cement mortar, (b) 20 mm. thick plaster

59.58

175

10426.5

... More
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.

115.92

34

3941.28

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. 150 mm. dia. ERW pipe.

48

134

6472.32

... More
100 mm dia. NB ERW/MS Pipes

24

82

1980.24

... More
Erection, fitting, fixing of set of M S tripod inlet and outlet pipe fittings for MDTW/MINI RLI Scheme. (Rate inclusive of transportation from departmental store to work site).

1

12466

12466.74

... More
Labour charges for fitting, fixing 100 mm. Dia. Alfa-Alfa valve with 110 mm. dia.P.V.C. pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C.End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. Complete.

9

112

1009.89

... More
Fitting and fixing of M.S. / G.I. / C.I.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge. 150 mm dia and 100 mm dia sluice valve.

4

54

218.76

... More
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include one materials and labour complete as per drawing and direction of EIC.

1

3677

3677.51

... More
Extra transportatation charges for carriage of of construction materials of repairing and maintenance of pipe line (except departmentaly supplied materials earth cutting and earth filling @ 4% on all actual executed item by cart/ boat/ head load with proper approval of EIC. WRDD (WB) [Excl. Item No. 34,35,36,48,49&52]

0.04

143364

5734.58

... More
Solar: Solar Module: Supply , transport , installation and commissioning of ISI marked Solar Modules as per following specification: 1. Cell: Indigenous mono crystalline silicon SPV cells 2. Solar Module: Monocrystalline cell with PERC technology / module with bifacial cell. 3. Standards: ISI marked as per IS 14286 and having certification of IEC 61853(1), 61730(1&2), 61710 4.Modules must qualify to IS 170210 (Part 1) 5.Min. Efficiency: 19.5%. 6. Fill factor: More than 75% 7. Module wattage mismatch in the SPV array: within ±3% 8. Wattage output warranty:Should not be less than 90% at the end of 10 years and 80% at the end of 25 years. 9.The power output of individual PV modules used in the PV array, under STC: minimum 300 Wp. Necessary test certificates also to be supplied. For detail information please see Cl. no. 2.1 of technical specification . d)For 5 HP Off-grid / On-grid Solar Water Pumping System with Monocrystalline/ Monocrystalline PERC/bifacial SPV modules - 5400-5800 Wp.

11000

32

355190

... More
Module Mounting Structure: Supply , transportation & installation of G.I manual tracking/ Fixed structure made of MS hollow sections, pipes, plates, angles etc as per IS 4923, IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Module as per drawing and specification . The steel structure is to be protected with minimum 80 micron galvanisation(hot dip) and provided with fixed arrangement or dual axis manual tracking arrangement for three times in a day and seasonal tilting are to be regulated to face the sun optimally. [The weight of the Module Mounting Structure given in Clause no. 5.1 should be followed. (1 no. 6 module + 1 no. 4 module Fixed str. - 2 sets)]

1140

157

178980

... More
Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per approved drawing. For 4 module structure

2

9136

18272.94

... More
For 6 module structure

2

11566

23132

... More
Power conditioning unit with enclosure : Supply , transport , installation and commissioning of Solar Power conditioning Unit consisting of following components and features: 1) Variable frequency Drive with inbuilt MPPT, voltage range suitable for operating pump-motor set of 1HP to 20 HP, detail mentioned in 2) Power input : DC source for 1HP, 2HP and 3HP. 3) Power input : AC / DC source or hybrid for 5HP and above. 4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.5HP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5) Incomer: AC MCB 4 pole 16 amp for 5.0 HP, 25 amp for 7.5HP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 6) Type II DC SPD of 40 KA. 7) Type II AC SPD of 40 KA for AC/ DC or Hybrid input. 8) Dual input (solar/Grid) 25 amp changeover switch for 5HP and 7.5 HP, 40 amp for 10 HP, 63 amp for 15 to 20 HP 9) Reverse protection diode 1600 VDC with heat sink. 10) Data Logger. 11) Remote monitoring system. 12) Should have built –in EMC filters . 13)IP 65 glands for cable in and out. 14) Min. IP 54 enclosure. For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standards to be qualified, etc. please refer to Cl. 6.1 of technical qualification. Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(g), to 3(l). For 5 HP capacity Pump-motor set with DC input

2

56882

113764

... More
Cable and Accessories : Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5m(for 1HP/2HP/3HP) & 20m(for 5/7.5/10/15/17.5/20 HP) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc for 2 or more Structure per Structure with 9 m distance between structures.

4

3434

13736

... More
Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

4

2661

10644

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of 8 swg on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages

80

13

1040

... More
a) Lighting System at Scheme: (with lighting Pole) : Dusk to dawn lighting arrangement of at 4 mts height above ground level, with Hot dip galvanised 80 mm x 50 mm , medium duty pipe, with 12 V, 15Ah 2-in-1 Lithium ion/ Ferro- Phosphate battery with in-built 7-11watt LED lamp , 50 Wp solar panel (min 19% Eff.) to cover the scheme area. The lighting system should be warranted for 5years from the date of installation.

1

19030

19030

... More
b) Lightning protection (Pole mounted): Lightning protection with 3" X 1.5" G.I pipe of 6m + 1 m height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. including connection to earth electrodes with 25 X 6mm G.I strip. (Provision of one lightning protection for each scheme as per drawing)

2

10683

21366

... More
Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:- c) 5 HP ISI marked 3 phase AC 415 V Pump-Motor set having discharge at required head as below:- i) Monoblock Surface Pump-motor set ISI marked as per IS: 9079 for mini RLI scheme with discharge of 13.8 Lps at 18 mts. total head with 100/80 mm dia. reinforced PVC suction pipe (20m) and delivery pipe(10mts), foot valve, nipple, priming bend Cable and all other required accessories to complete connection of suction and delivery side .

2

62406

124812

... More
Testing and commissioning of scheme after completion of all work

1

2000

2000

... More
b) Supply fitting and fixing of Hot dip Galvanised ( min 80 micron) / Powder Coat painted / Galvanised M.S Kiosk Box of 800(L) X 500(W) X 650(H) and total height with legs is 950mm (above ground) including foundation(as per drawing) for mounting of motor-pump set including transportation, - For 5 HP surface pump.

2

14157

28314

... More
Comprehensive maintenance charges for 5 years (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time) c) For 5 HP both for Submersible & Surface pump Note:1 Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit. Comprehensive maintenance charges will be released @ i) Rs 0.80 for 2 HP, ii) Rs.0.80 for 3 HP, iii) Rs.0.60 for 5 HP / 7.5/ 10 HP / 15HP / 17.5HP and 20 HP Submersible & Surface per Wp per year at the end of each maintenance period i.e.at the end of 1st year, 2nd year, 3rd year, 4th year& 5th year. In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited

11000

3

33000

... More
Insurance @ 2% for Item No. 54,57,61 and 63 for a period of 5 years. Note:2 Ist year's Insurance charge is to be paid on production of Original Receipt of premium payment. Remaining 4 years Insurance payment is to be withheld which will be released during 2nd, 3rd , 4th & 5th year on production of Original Receipt of premium payment.

612796

-

12255.92

... More
Remote monitoring for 5 years: Provision for remote monitoring for the pumps must be made in the pump controller through an integral arrangement having following basic functions: a. Controller must be assigned with a unique serial number and its live status must be observed remotely on online portal through login credentials. b. Live status must indicate whether controller is ON/ OFF. The parameters i.e. the water output, water flow rate, in fault condition, array input voltage/ current, power and motor frequency should at logged at an interval of 10 minutes c. Controller must have a back up to store the data locally ( at least for 1 year) supply & installation of GSM/GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameters to central server from the solar pumping system with time stamp at user-defined interval and report generation at the buyer end. (Refer Technical Spec.)

1

21850

21850

... More
Cleaning and washing of modules once in a month with clear water to remove deposited dust and dirt on the module surface and keep the modules clean throughout the year. The activity to be performed for eight months in a year excluding four monsoon months. A log book should be maintained at thr site for the said purpose.

160

300

48000

... More
WUA: Campaigning in the command area of Mini RLI Sub-project by community workers for mass awareness , capacity building to achieve sustainability of Sub-projects. Cost include wage payment to community workers, transportaton, leaflet etc.

2

2600

5200

... More
Demarcation of command area, selection of beneficiaries and preparation of land schedule within the Command area of New Major RLI having CCA 20 Ha

1

3500

3500

... More
Meeting Cost for WUA formation, cost including Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charges

1

3000

3000

... More
Registration Cost for WUA under suitable act ( Society ) deed writing including registration charge, conveyance cost & opening of Bank A/C Charges etc

1

1200

1200

... More
Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge ( rate on meeting )

4

3000

12000

... More
Meeting and onsite demonstration for operation & maintenance of one Mini RLI , water manangement and mode of collection of water tax, building of corpus fund etc

2

3000

6000

... More
IEC Materials ( Leaflet, poster, notebook )= 8 meetings, for SL - 71 and SL-73

55

35

1925

... More
Documentation Cost for activities of WUA Scheme - by still photography, report booklet etc in both hard and soft copy.

1

1000

1000

... More
Impact study & monitoring of scheme by site visit of 2 Community workers during 3 years' period

8

1200

9600

... More
Add GST @ 18 % on all item from (34 to 69)

1

242681

242681.37

... More
Add Cess @1% on all from item from (34 to 69) & 81

1

15909

15909.11



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.