Water Resources Development Directorate Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Civil And Construction
Excavation
Eprocure
Opening Date28 Feb 2025
Closing Date17 Mar 2025
Tender Amount₹ 18,71,854 
Notes
Download

Costs

Summary

Re-drilling Against Tubewell At Goalbari D.t.w. (bn- 285) Under Manteswar Development Block

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
150 mm dia Galv. MS Flanged pipes (4.8 mm Wall Thickness) as per ISI marked - IS:1239 , Galv -IS 4736 with latest Amendments thereof duly welded on both sides of pipe on inside & outside with corresponding diameter of M.S Flanges as per IS- 6392/1971, Table- 17 with latest amendments thereof. Both Galv. MS pipes & Flanges should be duly ISI certification marked. Length of the Flanged Galv. M.S Pipes should be 6 meter + - 10 mm

18

3800

68400

... More
Supply of 90 degree G.I Bend as per ISI marked IS : 1239 Galv -IS : 4736 with latest Amendments thereof duly welded on both sides of pipe on inside & outside with corresponding diameter of M.S Flanges as per IS- 6392/1971, Table- 17 both bend & Flanged duly galv. IS 4736 150 mm dia

1

8175

8175

... More
Supplying ISI marked C.1. Sluice Valve with hand wheel, for water works purpose CI flanged type conforming to IS: 14846/2000 with Amdt no 1 & 2 components /parts of sluice valves shall be manufactured from basic materials given in table 1 of IS 14846 /2000 with Amdt. 1 & 2. The valves shall be tested for (closed end test) against hydrostatic test equipments. including cost of carriage, loading & unloading of materials of 150 mm Nominal size (PD)

4

9950

39800

... More
Supply of fabricated and manufactured M.S. Surge Tank as per drawing (Annexure-H), the body of which made of 3 mm th. sheet and top & bottorm cover are made of 5 mm thick M.S. Sheet welded with the body and strengthened with rib etc. All joints must be electrically welded to a leak proof condition and joints must be capable of withstanding pressure of 50 PSI. The surge tank should be fitted with all accessoriees as specified in the drawing. Entire Surge Tank is to be painted with two coats of anticorrosive paint both inside and outside over a coat of priming as per direction of Engineer-in-Charge including cost of carriage , loading & unloading an all taxes of materials

1

17580

17580

... More
Supply of MS Hexagonal head Bolts & Nuts bearing IS-1363(Part-1)/1992 of product grade C with latest amendments for Bolts and IS 1363 (Part-3)/1992 of product grade C with latest amendments for Nuts properties/class for Bolt 4,6 for Nut 4,5 both Bolts & Nuts of various sizes ( M 10 to M24) incuding cost of carriage, loading & unloading of materials

30

195

5850

... More
Supply & transport of Rubber Insertion 5 mm Thuick with proper re-inforcement 2 (Two) ply conforming to IS 638/79 with latest ammendments duly ISI marked suitable for raised surface of M.S Flange as per IS 6392/1971 with standard drilled hole (Table 5)

30

195

5850

... More
Supply of C.I NTP valve as per drawing (Annexture-E) with MS Spindle and weight of the bottom disc to be fitted with rubber washer which will be fitted tightly at the closing of NTP valve. There shoulbe arrangement of square type key holder made of MS, complete including two course of painting over a coat of priming. approxiate weight weight 20 kg excluding Keys Including cost of carriage , loading & unloading and all taxes 150mm dia.

10

4782

47820

... More
Drilling :- Drilling of bore hole 55.88 cm dia through any kind of soil by adopting any method of drilling (by Direct or Reverse Circulation Rotary Rig) upto required depth including digging trenches and pits etc. all complete. (I) Upto 30M below GL

30

1169

35077.8

... More
(ii) Beyond 30M upto 60M

30

1159

34794.9

... More
(iii) Beyond 60M upto 90M

30

1178

35360.7

... More
(iv) Beyond 90M upto 120M

30

1197

35926.5

... More
Labour charges for lowering of M.S. E.R.W. pipes, strainers, blank pipe etc. and fitting, fixing and jointing of tubewell assembly at sites by welding etc. as per direction of the Engineer-in-Charge. 200 mm NB Blank pipe,Slotted pipe & Bottom Plug

72

235

16973.28

... More
350 mm NB Housing Pipe

42

518

21782.04

... More
Supplying fitting fixing including fabrication with required materials (IS: 2800 Part-I with latest amendments) as directed by the Engineer-in-Charge and lowering in position etc. (I) (i) 10 mm. thick (350 mm x 200 mm) NB M.S. Reducer of approved quality including socket.

1

3754

3754.83

... More
(ii) M.S. Centre guide (consisting of 3 nos., 6 mm thick, 50 mm wide, not less than 600 mm long and 125 mm rise of arch) of approved quality

24

231

5544.48

... More
(iii) MS Top cap of suitable size (8mm thick) and approved quality for covering top of housing pipe of 350mm NB (Top cover will be tack welded with housing pipe at 4 points 90 Degree apart)

1

1073

1073.08

... More
(iv)100 mm width x 12 mm thick Sockets / Rings made from MS Flats by rolling process and double butt welding for joining 350 mm NB Housing Pipe.

6

721

4328.16

... More
(v) 75 mm width x 10 mm thick Sockets / Rings made form MS Flats by rolling process and double butt welding for ioining_200 mm NB Pipe.

15

429

6435.6

... More
Supply of gravel for use as pack in tube well of 2 mm to 4 mm. size (as per IS: 4097) and gravel treatment of tubewell including screening, washing, cleaning etc. of the gravels at the site, all complete as per direction of the Engineer-in-Charge. For sites any district of West Bengal upto 120 km distance from quarry

35

3411

119402.5

... More
Development of tubewell in accordance with IS: 2800 (part 1j and IS: 11189 to establish maximum rate of usable water yield without sand content beyond permissible limit with required capacity of compressor ( about 200 psi, 375 cfm Aircompressor, actual psi and cfm depend on tube well head conditions),running the compressor for required time till well is fully developed and followed by development of tube well by over pumping with 15% to 25% higher discharge than expected discharge of tube well capacity and Vertical Trubine pump and carrying out step-drawdown test, yield test, verticality test etc. as per prescribed method all complete including hire & labour charges of compressor, tools & accessories etc. all as per requirement and direction of Engineer In Charge. Depth upto 120 metre.

1

36469

36469

... More
Electrologging of bore hole of different dia tubewell for locating water bearing strata and saline aquifer, if any, after conducting relevant geophysical tests. All test reports, compiled data and raw data sheets should be submitted to the Engineer-in-Charge (Cost is inclusive of all charges for equipments, labour, data aquisition & compilation of data sheets as per direction of the Engineer-incharge)

1

8015

8015.08

... More
Making slots of 75 mm X 1.60 mm size with a minimum clearance of 4.70 mm in between two adjacent slots over the outer surface of 200 mm NB ERW pipes (to be issued departmentally) in 10 (ten) rows (each row consisting of 96 slots) per metre length of ERW pipe with a clearance of 25 mm in between two rows as per drawing and specification including smoothening the edges after slotting, cost of transportation of ERW pipes from Departmental Store to Workshop and back to drilling site, loading, unloading and carrying by head-load where necessary both ways, all complete.

30

942

28288.5

... More
Mobilisation charges for transporting upto site including loading, unloading of all plants, machinaries and equipments required for drilling, development and testing of Tubewells and also the cost of construction of temporary roads over field and lor, culverts, repairing existing roads and I or culverts all complete, carrying materials on head load, carts or boats as the case may be :- (i) for sites within 4 km from all weather metal road)

1

7625

7625.64

... More
Supplying, fitting and fixing M.S. clamps for fixing Starter & main switch. made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. 40mm X 6mm, 125mm Length

6

20

120

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. l) 3 x 80/0.4 (10 sqmm)

6

302

1816.92

... More
Fixing only Voltmeter/Ammeter/Energy meter with screws & other fixing materials incl. making necessary holes and connections

2

58

117.42

... More
Supply & Fixing EI danger board on wall b)15 cm x 10 cm (6"x4")

2

56

113.3

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe

2

1410

2820.14

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required

0.3

160

48.2

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. iii) No. 8 SWG

10

9

92.7

... More
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 240V DP with fuse on L&N 15/16 A (Standard)

1

534

534.57

... More
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.

9

39

352.26

... More
Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.) (a)100/150/200 cubic metre per hour capacity electro motor pumping set. (i) Length of pump assembly of any length exceeding 18 metre length.

1

1510

1510.61

... More
Supplying, fitting & fixing 350 mm x 250 mm x 25 mm size Wooden Plank on wall (for fitting & fixing of electrial equipments as necessary on the plank).

6

413

2478.06

... More
Supplying, fitting & fixing of 32 Amps / 63 Amps / 100 Amps, 415V rewireable type porcelain body Fuse top & base complete set conforming to IS: 13947/Part-4/Sec-I/1993 over wooden plank/ board on wall and making necessary connection with the electrical cable as per direction of the EIC 100 Amps

4

737

2949.56

... More
Joining water proof cable with the leads of the motor including soldering with requisite water proof insulation and proper joining compoundNulcanized rubber tape so that proper water proof insulation is assured.

6

150

900

... More
Fixing only Sheet Steel Main Switch (Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall 415V TP/TPN 100/63 Amps On angle iron frame

1

221

221.45

... More
Supplying, fitting & fixing of M.S. plate of size 40 cm x 40 cm, thickness 6 mm, consisting of two equal halves (40cm x 20 cm), placed over Housing Pipe of HDTW/ MDTW to rest the supporting clamps, with semi circular hole of 170 mm dia. at centre including locking arrangement between the two halves on both sides, including fitting, fixing of 40 mm dia. G.I. bend by making a hole on plate for passing submersible cable smoothly and complete in all respect.

1

897

897.69

... More
Withdrawal of electro motor submersible pumping set of following capacities from within the tubewell housing pipe of the following length by using all necessary requisites tools and plants and carefully as per direction of Engineer-in-Charge and stacking the same properly at site within the tubewell premises complete. (a)100/150/200 cubic metre per hour capacity electro motor pumping set. (ii) Length of pump assembly of any length exceeding 18 metre length.

1

1045

1045.73

... More
Fitting & fixing of Starter (Direct on Line or Star-Delta/Auto-Transformer) with Nuts & Bolts fixed on Angle iron frame on wall and making necessary connection with the lectrical ii) Star-Delta / Auto-Transformer Starter (Above 15 HP upto 25 HP)

1

240

240.45

... More
Patch/Doubling works complete with M.S. plate including welding, gas cutting, fitting, fixing complete. (a) Cost of 5 mm M.S. plate including wastage due to cutting, including labour charges for straightening fitting, fixing in position.

0.3

2432

729.84

... More
(b) Gas cutting to required size of upto 8 mm thick M.S. plate, Channel, Angle etc. including labour charges, hire charges for all tools and plants.

5

185

928.8

... More
Welding in MS structural work with gas or electric b) continuous weld

650

9

5850

... More
Supply of high density poly- ethylene pipe conforming to IS 4984-1985 , 6 kg / Sq cm ( working pressure) 40 mm dia for laying 3x 6 sqm flat cable of submersible pump motor.

35

72

2520

... More
Labour for fitting and fixing high density poly- ethylene pipe for under ground work including cutting trnches upto 1.50 mtr and refilling the same and also fixing all necessary specials, cutting pipes, making threads in all completeas per direction of the EIC

35

37

1295

... More
Cutting trench through passage upto 40 mm wide including refilling,watering & ramming

35

29

1015

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i)(a) 150 mm. dia. ERW pipe.

24

134

3236.16

... More
150 mm dia. E.R.W. pipe 90° bend, both ends flanged.

2

49

98.06

... More
150mm. dia. C.I. Sluice valve.

5

54

273.45

... More
150 mm. dia. special bend, both ends flanged.

3

81

243.27

... More
Carriage of Departmental materials from the Deparmental Store to the work site and return back the damaged/replaced and unused materials to store including loading & unloading complete at both sides by Tempo /Van Rikshaw/Mini Truck etc. upto 25 Km distance in one way. Pump-Motor Set (this item is applicable only for burnt/damaged Pump-Motor Set)

1

1037

1037.25

... More
For Delivery pipe, Surge Tank, Bend, Valve etc.

1

905

905.23

... More
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

4.25

324

1377

... More
Brick work with 1st class bricks in cement mortar (1:6) (b) In foundation & plinth,Gr. floor.

2.6

4812

12511.2

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety.

0.75

5237

3928.05

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface. (i)(b)15 mm. thick plaster, with (1:4) cement mortar.

20.25

152

3078

... More
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.

20.25

34

688.5

... More
Dismantling the existing G.I.lM.S. Delivery Pipe line connection between the existing D.C.lSurge Tank!Tripod Set & Tube Well assembly viz Sluice valve,Bend, Surge ank/Distribution Chamber !Tripod Set Connection pipe etc. disconnection of delivery side viz. Special bend etc. all complete as per direction of the E.!'C. and stacking all serviceable materials at site

1

752

752.47

... More
Installation / Erection of SurgeTank / Shore manifold (to be supplied from Deptt. free of cost) over a rigid base of ordinary cement concrete (1:2:4) with graded stone chips (20mm. nominal size) of pakur varity of 1250 mm X 1250 mm X 150 mm. over a single layer of brick flat soling and embedding the legs of the surge tank/shore manifold within the concrete base including cost of all materials and labour and as per direction of Engineer-in-Charge.

1

2263

2263.08

... More
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Approved make) of following sizes in suitable size PVC casing-capping (Precision make) including. necy. PVC clips, fittings etc. [Main switch to switch board] c.) 2 X 36/0.3 (2.5 Sq.mm.) + 1 X 22/0.3 (1.5 Sq.mm.)

3

105

315.18

... More
Distribution wiring in 1.1 KV grade 2 X 22 / 0.3 (1.5 Sq.mm.) single core stranded 'FR' PVC insulated and unsheathed copper wire (Approved make) in suitable size PVC casing-capping (Precision make) with 1 X 22/0.3 (1.5 Sq.mm.) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] a). Avarage Run 5.00 Mtr.

6

594

3565.86

... More
Distribution wiring in 1.1 KV grade 2 X 22 / 0.3 (1.5 Sq.mm.) single core stranded 'FR' PVC insulated and unsheathed copper wire (Approved make) in suitable size PVC casing-capping (Precision make) with 1 X 22/0.3 (1.5 Sq.mm.) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to 5 A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with Perspex/bakelite (Wall maching colour) top cover of 3mm. thk. flushed in wall by housing the board after cutting brick wall incl. necy. connections and making earthing attachment painting and mending good damages to building works. [PVC casing-capping and Plug Box both on surface] a. On Board

2

69

138.02

... More
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. ncluding stacking of steel bars.

3.26

1956

6374.6

... More
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.

3.41

447

1525.16

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

18.28

324

5921.1

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety.

1.48

5237

7761.83

... More
Brick work with 1st class bricks in cement mortar (1:6) including racking out joints scafolding and other incidental works etc complete In foundation and plinth

1.14

4812

5490.49

... More
Superstructure in Ground floor

6.27

5035

31584.56

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. Steel Surface

30.5

29

884.5

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

6.15

664

4083.6

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety.

3.96

5792

22928.13

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams,columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 37.5 mm. thick wooden shuttering. In ground Floor

28.12

328

9224.18

... More
25 mm to 30 mm thick wooden shuttering without staging in foundation

9.45

205

1937.66

... More
Reinforcement for reinforced concrete work in all sorts of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening of bend bars excluding coil bars and removal of loose rust (if necessary) cutting to requisite length, hooking, bending to correct shape, placing in proper position and binding with 1.626 mm (16 SWG) black annealed wire at every inter section complete as per drawing and direction including cost of wire upto 1st floor level. For For Tor steel SAIL/ TATA/ RINL

0.42

60433

25381.86

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners, as directed and racking out joints or roughening of concrete surface including throating, nosing and drip course as necessary at ground floor. with (1:4) cement mortar. (a) 20 mm. th. plaster.

55.25

174

9613.5

... More
with (1:4) cement mortar. (a) 15 mm thick plaster.

85.65

152

13018.8

... More
with (1:4) cement ortar.(a) 10 mm. thick plaster.

20.5

123

2521.5

... More
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete. Outside, inside, plinth portion, appron and drain.

55.25

34

1878.5

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)

30.5

79

2409.5

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as ecessary) and marble dust in proportion (1:2) including smooth finishing and founding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement 25 mm th.

19.25

264

5082

... More
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification Two coats ii) Internal & External surface (Ground floor)

104.25

49

5108.25

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.110 mm. Dia.

3

251

753

... More
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, abrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. For structural members of specified section weighing less than 22.5 kg/m MS angle size For door 40 x 40 x 6 mm & Window - 30 x 30 x 4 mm (Frame)

0.07

72603

5082.21

... More
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, Angle, W.I. Flats , bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (For Door, window frame of shutter , window grill & ver Grill)(ii) Grill weighing above 10 Kg./sq. mtr. & upto 16 kg/sq.mtr.

3.75

9888

37080

... More
Supplying 1 .5mm thick M.S. sheet fitted and fixed on one faces of M.S./ W.I.gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labourand materials.

5.75

1304

7498

... More
Cement washing including cleaning and smoothening surface thoroughly (cement to be used @15 kg./100 sq.m. of surface for one coat and @25 kg./100 sq.m of surface for two coats):(b) Two coats (on new works only).

1.06

1424

1513

... More
(A) Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

4.37

640

2800.56

... More
N.B.:- The tubewells are generally installed in cultivable field located at remote places, away from town. So it involves extra carriage by cart / boat / head load besides initial transport of construction materials by truck. Therefore for Water Transmission Arrangement of Tubewells following extra rate should be allowed over the scheduled rates, save and except for earth works. i) H.D.T.W. / M.D.T.W. - 3% excluding sl.no 62,63,

1

6286

6286.7

... More
Dismantling all types of masonry exception cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 mtrs a)In ground floor including roof.

3.39

447

1515.33

... More
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m In ground floor including roof.(a) upto 150 mm. thick

1.35

939

1264.83

... More
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils within a lead of 75m. as directed. The item includes nesessary trimming the sides of trenches, levelling, dressing and ramming the bottoms, bailing out water as required complete. Depth of excavation not exceeding 1.5 metre.

1.13

119

134.78

... More
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

25.55

324

8278.2

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety.

4.13

5237

21630.46

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

7.75

4812

37288.19

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

24.15

664

16035.6

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed andraking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Groundfloor).[Excluding cost of chipping over concrete surface(ii) with (1:4) cement mortar. (a) 20 mm. thick plaster.

18

174

3132

... More
(b) 15 mm. thick plaster.

134.42

152

20431.84

... More
Neat cement punning about 1.5mm thick

152.42

34

5182.28

... More
Earth work in excavation of field trenches as per design section and alignment for laying of pipe lines (PVC, RCC, ACP etc.) upto a depth of 1500 mm all sorts of soils including removing, spreading or stacking extra earth as directed. The item includes necessary trimming of sides trenches, levelling, dressing and ramming the bottom as required complete

507.96

99

50293.12

... More
Repairing of leakages in collar joints of R.C.C. Pipe line by opening the joints fully by chipping out the old morter, cleaning the pipe recesses and collar properly, and thereafter positioning and levelling the pipes and collar, filling the annual spaces of joints with jute braiding dipped in cement slurry and grouting with (1:2) cement morter mixed with approved quality water proofing compound (5% by wt. of cement) and curing all complete as per direction of Engineer-in-Charge. (i) 225 mm dia. R.C.C. Pipe.

300

67

20367

... More
Taking out the damaged R.C.C. Pipe and two collars by dismantling two joints carefully, carrying and stacking the same near the pump house, carrying new pipe and collars from the field stack, lowering the same within the trench, properly positioning and levelling on bricks laid flat, between collar and the pipe joints with jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved quality water proofing compound (5% by weight of cement) and curing all complete as per direction of Engineer-in-Charge.(c) 225 mm dia. R.C.C. Pipe.

10

115

1159.8

... More
Removing of Chokage due to sludge, mud, sand or any other forign materials deposition from the underground 450 / 300 /225/ 150 mm dia. R.C.C. Pipe Line with split bamboo, wire brush, coir rope etc. along with suitable cleaning agent as necessary as per direction of E.I.C. (This item includes cost of earth cutting & back filling of trenches and required materials for cleaning but excluding the cost for taking out 1 full length of RCC Pipe by dismantling of 2 nos. of Collars & re- fitting the RCC pipe with new two nos. collar). iii) For 225 mm dia. RCC Pipe

200

38

7732

... More
Taking out the damaged R.C.C. Tee and 3 nos. collars by dismantling three joints carefully, carrying and stacking the same near the pump house, carrying new R.C.C. Tee and collars from the field stack, lowering the same within the trench, properly levelling and positioning on bricks laid flat, filling the annual space betwen pipe fitting and collars with jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved water proofing compound (5% by weight of cement) and curing etc. complete as per direction of Engineer-in-Charge (a) 225 mm × 225 mm × 150 mm R.C.C. Tee.

2

148

297.98

... More
Taking out the condemmed 150 mm dia. N.T.P./T.P./ Alfa-Alfa valve from 150 mm dia. M.S./G.I. pipe of existing spout chamber by careful chiseling with least disburbance to the existing system of structure upto required limit and fitting, fixing of new one with 150 mm dia. M.S./G.I. pipe in proper position of the spout chamber using havoc zinc jute so as to make the joint leak proof including mending good all damages and returning back the condemned materials at store as per direction of Engineer-in-Charge.

10

81

810.9

... More
Jointing the end of 150 mm. dia. M.S. extension pipe for spout chamber with 150mm. end of R.C.C. Tee including carrying the M.S. extension pipe from store to site, levelling and positioning the end of extension pipe concentrically with 150mm. end of R.C.C. Tee on bricks laid flat within the field trench and jamming the joints with cement concrete (1:2:4) with stone chips 10 mm. down mixed with approved water proofing compound 5% by weight if cement) of adequate thickness to provide a leak proof joint as per direction of Enginer-in-Charge (Cost of bricks for levelling is included).

5

81

405.45

... More
Earth work in filling in trenches after laying pipe lines (PVC, RCC, ACP etc.) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished .quantity of work.)

507.96

66

33530.44

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation.

0.01

7754

65.91

... More
Due to extra carriage by cart / head load besides initial transport of construction materials by truck. Therefore add extra @ 3 % over the schedule rates except item no 88,89,90,98,106,107

1

5710

5710.22

... More
Add GST @18% (CGST 9% AND SGST 9%) for works Items

1

166117

166117.03

... More
Add Labour Welfare Cess @1%

1

10889

10889.89



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.