Water Resources Development Directorate Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Water Resources Development Directorate - WRDD Tender
Civil And Construction
Eprocure
Opening Date3 Oct 2024
Closing Date19 Oct 2024
Tender Amount₹ 2,07,841.89 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 19,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Installation Of Solar Operated 150 Mm X 100 Mm Nominal Diametre Size Light Duty Tubewell (ldtw) Scheme Up To A Depth Of 150 Mtr. With Upvc Pipe, At Mouza - Kusturi Bani
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WRDD_759534_4Bid Award Id
ViewTender No
WBWRIDD/EE(AI) /e NIT- 09 / Jhargram / 2024-25Tender Authority
Water Resources Development Directorate ViewPurchaser Address
-Website
http://http://www.wbwridd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (J) Threaded End Cap 100 mm Dia.
1
145
145.14
Casing Pipes lSI marked- IS12818
g). 150 x 100 Socket (CD)
1
1469
1469
Supplying, fitting and fixing G.I. cap at top.
(iii) 150 mm
1
593
593.54
3C Flat water proof CU.cables lSI marked-IS 694. b) 3C X 2.5 sq. mm (N. B. - This material will be supplied Departmentally) [ Department Supply ]
55
-
-
Galv. M S Column pipe, 1S1 marked -1239, Galv- IS4736.g) 80 mm dia both end screwed & one end socketted 3m long (bottom) (N. B. - This material will be supplied Departmentally) [ Department Supply ]
15
-
-
Supplying 80 mm dia GI plain bend with ISI mark.
1
1726
1726.34
GI. Holding Clamp- IS 1239, Galv- IS4736 c) 80 mm dia [ Department Supply ]
1
-
-
P.V.C.Flexible Hose pipe, lSI marked -IS 15265 c) 100 mm dia lay Flat Hose (Non-lSI)
100
17000
170
Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (a) For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 metre). (i) First 50 metre
50
50700
1014
Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (a) For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 metre). (ii) Next 50 metre
50
44150
883
Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (a) For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 metre). (iii) Rest 50 metre
50
52750
1055
Electrologging of bore hole of different dia tubewell for locating water bearing strata and saline aquifer, if any, after conducting relevant geophysical tests. All test reports, compiled data and raw data sheets should be submitted to the Engineer-in-Charge (Cost is inclusive of all charges for equipments, labour, data aquisition & compilation of data sheets as per direction of the Engineer-incharge
1
8015
8015.08
Supply of gravel for use as pack in tube well of 2 mm to 4 mm. size(as per IS: 4097) and gravel treatment of tubewell including screening, washing, cleaning of the gravels at the site, all complete as per direction of the Engineer-in- Charge
5.14
14998
2917.5
Washing and development by pumping with 30 cum per hour capacity pump for a period till sand free water comes out and the discharge is about 30 cum per Each 4563.88 hour, followed by final yield test; inclusive of all tools, plants and scaffolding and Tube-well hire charge of submersible pump, generator etc. all complete.
1
4563
4563.88
Supplying fitting and fixing including transprtation of sign board for identifying the exact location of MINI RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm * 600 mm and fitted and fixed on 50 mm GI pipe of IS 1239/90 (part-1) including cutiing, welding LS and writing of both sides of sign board. Base-yellow, and words- Red. Both bottom end of the stands pipe will be grouted in 1: 2: 4 CC on a single brick flat soling. This will include one materials and labour complete as per drawing and direction of E.I.C
1
3677
3677.51
Painting block letters or digits in Black Japan or any approved paint as per direction. a) Size 2 cm. to 2.5 cm.
150
900
6
Painting block letters or digits in Black Japan or any approved paint as per direction. b) Size above 2.5 cm. and upto 4 cm.
150
1200
8
Mobilisation charges for transporting upto site including loading, unloading of all plants, machinaries & equipments required for drilling, development and testing of Tubewells and also the cost of construction temporary roads over field and / or culverts, repairing existing roads and / or culverts all complete, carrying materials on head load, carts or boats as the case may be :
(i) For sites within 4 km from all weather metal road.
1
7625
7625.64
Solar Photovoltaic Installation : Supply, transport, installątion and commissioning of ISI marked Solar Modules as per following specification:1. Cell: Indigenous mono crystalline silicon SPV cells 2. Solar Module: Monocrystalline cell with PERC technology/module with bifacial cell. 3. Standards: 1st marked as per IS14286 and having certification of IEC 61853(1), 61730(1&2),61710 4.ModuIes must qualify to lS170210 (Part 1)5. Min. Efficiency: 19.5%. 6. Fill factor: More than 75%. 7. Module wattage mismatch inthe SPV array: within -t3% 8. Wattage output warranty: ShouId not be less than 90% at the end of10 years and 80'Xat the end of 25 years.9. The power output of individual PV modules used in the PV array, under STC: minimum 300 Wp. Necessary test certificates also to be supplied. For detail information please see CI. no. 2.1of technical specification
d) For 5 HP Off- grid Solar Water Pumping System with
Monocrystalline/ Monocrystalline PERC/ bifacial SPV modules-5400-5800Wp.
5400
174366
32.29
Module Mounting Structure ( For 2HP, 3HP and 5HP Solar Water Pumping System): Supply , transportation & installation of G.I manual tracking structure made of MS hollow sections, pipes, plates, angles etc as per IS:4923, IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Module as per drawing and specification of MNRE. The steel structure is to be protected with minimum 80 micron galvanisation (hot dip) and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be regulated to face the sun optimally. The approximate weight of the Module Mounting Structure given in Technical Specification Clause no. 5.1. - For 5 HP – should be 280 kg 1 no MMS of 4 Modules ( Manual Tracking Structure) & 350 kg 1 no MMS of 6 Modules ( Manual Tracking Structure)
630
98910
157
Foundation of Module Mounting Structure: Suitable
and stable Reinforced Cement Concrete foundation for
dual axis manual tracking SPV Module structure as per approved drawing.
a ) For 6 module structure.
1
11138
11138.59
Foundation of Module Mounting Structure: Suitable
and stable Reinforced Cement Concrete foundation for
dual axis manual tracking SPV Module structure as per approved drawing.
a ) For 4 module structure.
1
9381
9381.38
Power condltlonlng unit with enclosure: Supply, transport, installation and commissioning of Solar Power conditioning Unit consisting of following components and features:
1) Variable frequency Drive with Inbuilt MPPT, voltage range suitable for operating pump-motor set of 1HP to 20 HP, detail mentioned In cl.6.1
2) Power Input : DC source for 1HP, 2HP and 3HP.
3) Power input : AC / DC source or hybrid for SHP and above.
4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.SHP and 10 HP, 40 amp
for 15 to 20 HP as per IS/IEC 60947-2
5) Incomer: AC MCB 4 pole 16 amp for 5.0 HP, 25 amp for 7.5HP and 10 HP, 40 amp for IS to 20 HP ar per IS/IEC 60947-1
6) Type II DC SPD of 40 KA.
7) Type II AC SPD of 40 KA for AC/ DC or Hybrid Input.
8) Dual Input (solar/Grid) 25 amp changeover switch for SHP and 7.5 HP, 40 amp for 10 HP, 63 amp for 1S to 20 HP
9) Reverse protection diode 1600 VDC with heat sink.
10) Data Logger.
11) Remote menltoring system.
12) Should have built -In EMC filters .
13)IP 65 elands for cable In and out.
14) Min. IP 54 enclosure.For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standards to be qualified, etc. please refer to CI. 6.1 of technical qualification.
Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(I).
g) For 5 HP capacity Pump-motor set with AC / DC or hybrid input
1
66381
66381
Cable and Accessories:
Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPEconduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc.
i. 4.0 Sq mm single core multi studs - 5 m (for 2HP) & 20 m (for 3/5 HP) ii. Lugs, HOPEPipe, Flexible Pipe, Saddle, Cable tie etc b) For two (2) or more number of structures - per structure with 9 m distance between them
1
3434
3434
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
(a) By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
1
2661
2661
a) Lighting System at Scheme: (with lighting Pole) :
Dusk to dawn lighting arrangement of at 4 mts height with 75 min x SOrnrn G.!. pipe with 12 V, 40Ah 2-in-1 Lithium ion/ Ferro- Phosphate battery with in-built 11 watt LED lamp, 50 Wp solar panel to cover the scheme area. The lighting system should be warranted for syea,.s from the date of installation.
1
19030
19030
a) Lightning protection (Pole mounted):Lightning protection with 3" X 1.5" G.I pipe of 6m + 1 m height with base flange In proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dla 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers Including socketing at both ends of stranded GI (Hot Dip) wire by crimplng sockets/ thlmbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. including connection to earth electrodes with 25 X 6mm G.I strip. (Provision of one lightning protection for each scheme as per drawing)
1
10683
10683
Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:- c) 5 HP 151marked 3 phase 415 V Pump-Motor set having discharge at required head as below:- iii) SubmersiblePump-motor set for lDTW lSImarked as per IS:8034 with dischargeof 7.5 tps- 5.83 lps at 30 mts.- 40 mts. total head with cable, cover plate, Socket, Flanged Nipple, Rubber Insertion, Nuts& bolts and all other accessoriesincluding transportation of Bend, Column Pipes,cable, Sluicevalve, lay flat hose pipe etc. from Deptt. Store to site within 100 krn.
1
46339
46339
Testing and commissioning of scheme after completion of all work
1
2000
2000
Comprehensive maintenance charges for 5 years (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time) a) For 2 HP both for Submersible & Surface pump
Note:l Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit. Comprehensive maintenance charges will be released @ i) Rs 0.80 for 2
HP, ii) Rs. 0.80 for 3 HP, iii) Rs. 0.60 for 5 HP/ 7.5/ 10HP/ 15HP/ 17.5HP and 20HP Submersible & Surface per Wp per year at the end of each maintenance period i.e. at the end of 1st year, 2nd year, 3rd year, 4th year & 5th year. In case the "Bidder" does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited.
5400
16200
3
Insurance @ 2%for Item No.3.01, 3.04, 3.08, and 3.09 for a period of 5 years.
Note:2
1styear's Insurancecharge is to be paid on production of Original Receipt of premium payment Remaining4 years Insurancepayment is to be withheld which will be releasedduring 2nd, 3rd ,4th & 5th year on production of Original Receiptof premium payment.
306116
6122
0.02
Making 80 mm dia GI Colum Pipes for LDTW : Labour charges for loading of 80 mm dia GI Pipe into trucks, carts, boats etc. at lifting point and unloading the materials at the destination and stacking the same as per direction including carriage by head load upto a lead of 100 metres at each end.(To & Fro).
84
554
6.6
Carriage of 80 mm dia GI Pipe over pucca road upto 5 km distance.(To & fro).
84
435
5.19
Cutting out & threading 80 mm GI Pipe.
28
896
32
Labour charges for fitting & fixing of 80 mm dia GI Socket .
14
154
11
Supply of 80 mm dia GI Socket with ISI Mark.
14
3164
226
Add GST @ 18% or as applicable as per Govt. rule.
660431.63
118877
0.18
Add Labour well fare Cess @1% of Gross Bill Value
779309.32
7793
0.01