Water Resources Development Directorate Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Water Resources Development Directorate - WRDD Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date18 Jul 2024
Closing Date26 Jul 2024
Tender Amount₹ 19,67,782
Costs
EMD
₹ 40,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WRDD_715933_1Bid Award Id
ViewTender No
WBWRIDD/EEAM /RAIGANJ (AM)/ eNIT NO.-57/2024-25(3rd Call)Tender Authority
Water Resources Development Directorate ViewPurchaser Address
-Website
http://http://wbwridd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and Delivery of 20 H.P Electro Motor Pump set having capacity of 200 cubic meter per hour discharge at 18 meter total head. The Motor shall be designed for operation at 415 V (+10%), 3 Phase, 50 Cycles per Sec (+-5%), A.C Supply 1500 r.p.m. The Motor shall be TEFC, ISI marked as per IS 12615 with latest amendments thereof. The Pump (Model of size 150x150mm) shall be horizontal, single stage, split casing, conforming to ISI specification as per IS-6595/1993 with latest amendments hereof. Pump should be directly coupled with Motor and mounted on a common fabricated M.S Base frame.
2
353800
176900
Supply and Delivery of Sheet metal enclosed re-wireable type Fuse, Main switch, 500 VOLTS, 3 phase, 50 Cycles A.C Supply conforming to IS:60947 (part-3)/1993 for-100 Amps 415 volts A.C TPN Main Switch.(Havells Make)
1
16260
16260
Supply and Delivery of Sheet metal enclosed re-wireable type Fuse, Main switch, 415 VOLTS, 3 phase, 50 Cycles A.C Supply conforming to IS:60947 (part-3)/1993 for-63 Amps 415 volts A.C TPN Main Switch.(Havells Make)
2
16836
8418
Supply of 20 HP Electromagnetic Star-Delta mottor controllers with 4 pole heavy duty Power Contactor, single phasing preventer and normal protective features, MCB, Indicators, push buttons, Ammeter, & Voltmeter, all in IP54 enclosure of min 16swg. C R sheet steel, 10 tank process powder coat painted and as per technical specification, as per IS: 60947.
2
49400
24700
Supply and Delivery of 12 mm thickness Busbar Chamber (100Amps, 500Volts) chamber 300 mm x 250 mm x105mm in size fitted with 12 mm x3 mm x230 mm copper bar (4bars) supplied with requisite brass nuts & bolts equivalent to bore size with at least 2 nos. of putter and 1 no inlet holes of 1-1/4" size on iron legs on w. board including arrangement of double earthing by 10 SWG GI wires.
1
9697
9697
Total Cost of Procurement of electrical Items
1
445993
445993
Construction of New Pump House
-
-
-
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.
21.42
2120
99.01
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
0.1
4874
48741
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
44.16
14307
324
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
3.45
20514
5946.34
Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
8.52
55411
6503.67
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering for pump house.
55.58
18230
328
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steel ( Other than SAIL/ TATA/RINL) i)For foundation Blocks of Water Distribution System
0.54
32209
60205
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete.a) In foundation & plinth.
11.02
54725
4966
b) In superstructure ground floor
15.13
78509
5189
Plaster (to wall, floor, ceiling etc.) with (1:6) sand and cement mortar including rounding off or chamfering corners, as directedand racking out joints or roughening of concrete surface including throating. Nosing and drip course as necessary at ground floor. a) 15 mm thick with 1:6 cement mortar.
87.2
12556
144
b) 20 mm thick with 1:6 cement mortar.
101.69
16880
166
c) 10 mm thick with 1:4 cement mortar.
21.22
2737
129
25 mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Water proofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
6.1
1256
206
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thick
46.53
12283
264
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
22.85
776
34
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor.(ii) Grill weighing above 16 Kg./sq.mtr and above.
3.96
29159
7371
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150 mm apart complete in all respect as per design including cost of all labour and materials.
10.4
10327
993
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete A) UPVC Pipes:(i) 75 mm. Dia
6
1128
188
B) UPVC Fittings:a) Plain Tee (i) 75 mm. Dia
2
204
102
c) Bend 87.5 degree (i) 75 mm. Dia
2
190
95
Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation.
14.88
982
66.01
Priming one coat on steel or other metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surfaces by sand papering etc.
32
928
29
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. Two coats (super gloss hi- gloss except white)
32
2400
75
White washing including cleaning and smoothening surface thoroughly (5 parts of stone lime and 1 part of shell lime should be used in finishing coat) all floor
0.97
1940
2001
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification.
97.79
4791
49
Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.
1
942
942.95
4% Extra Carraige (except item no 3.01, 3.04, 3.05, 3.21 & 3.26)
1
12016
12016.74
Add GST @ 18%
1
70633
70633.31
Add Cess @ 1%
1
4630
4630.41
Total value of Pump House
1
467671
467671.02
Electrical Connection to Motor & Internal wiring
-
-
-
Supply with Fitting & fixing of fabricated wooden pannel board of size 6 ft x 4 ft x1 inch with M.S. clamp on the wall of pump house/kiosk box in barge including jumming 2'-1" long 4 nos. angle made of 50mm x 50mm x 6mm M.S. angle welded with the pannel board for jamming in the wall by cement concrete (4:2:1). necessary arrangements will be made by the contractor at his own cost for fitting fixing the following electrical equipments/ meatrials in to the pannel board including 2 coats of painting of synthetic enemal paints of approved quality over one coat of primar including smoothening surface as per direction of Engineer In Charge.
1
5850
5850
Supplying, fitting & fixing of 32 Amps / 63 Amps / 100 Amps / 415V rewireable type porcelain body Fuse top & base complete set confirming to IS: 13947/ Part-4/Sec-I/1993 over wooden plank/ board on wall and making necessary connection with the electrical cables as per direction of E.I.C.
i) 100 Amps.
3
2212
737.39
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall.
a) 16 Amps Havells make.
1
576
576
Wiring in 1.1 KV grade single core stranded 'FR' PVC
insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. i)2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) (from cut out to 16 Amp Main Switch)
1
102
102
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5Amp 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/ perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to originalfinish [PVC casing capping and Switch board both on surface]
(i) Avg Run 7.5 meter.
4
3952
988
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
3
114
38
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set.
3
1737
579
Fixing only of 100 A, 415 V sheet steel TPN main switch on Angle iron Frame on wall.
1
215
215
Fixing only of 63 A, 415 V sheet steel TPN main switch on Angle iron Frame on wall.
2
430
215
Fixing only of 100 A, 415 V sheet steel Busbar Chamber (4 bars) on Angle iron Frame on wall.
1
486
486
Fixing only 20 HP Motor controller comprising of Oil immersed / Air break starters on Angle iron frame on wall
2
430
215
Meter loop connection with 1.1 K.V. Gr. 3½ core / 4 core 10 Sqmm to 50 Sq mm. P.V.C./ XLPE insulated & sheathed and armoured Aluminium/Copper Cable from Meter to incomming TPN Main Switch / Terminal. (Brand: Gloster/Havells/Finolex)
6
2919
486.56
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socketetc. conforming to IEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex)
[a] For Major RLI i)4Cx 25 sqmm Copper cable conforming to IS 694 [ Cut out to 100 A Main Switch and 100 A TPN Main switch to Bus-bar]
3
4684
1561.53
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socketetc. conforming to IEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex)
[a] For Major RLI i) 3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TPN Main switch and 63 A TPN Main switch to Motor Controller]
6
4763
793.96
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socketetc. conforming to IEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex)
[a] For Major RLI
i) 2 X 3C X 10 sqmm copper cable conforming to IS 694 (Motor Controller to Motor)
10
9269
926.92
Supplying & fixing of EI Danger board (20 cm. x 30 cm. )in four distinguishing position . As per IEE regulation.
2
170
85
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium G.I. Pipe.
4
5476
1369
Supplying and fixing earth bar of galvanized (hot dip) M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes on busbar complete with G.I. bolts, nuts, washers spacing insulators etc. as required for tapping.
1
156
156
Connecting the equipments to earth busbar including supplying and fixing G.I. (hot dip) Wire on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages.By Solid 8 S.W.G. GI Wire.
20
180
9
Insulation testing of internal wiring of Pump House/Kiosk Boxincluding wiring of electric Motor & other ancilary equipments by means of Megger.
1
165
165.02
Placing and positioning the Centrifugal pump motor set on the pump base/pump house floor, alligning properly with necessary packing and fixing the set with holding down nuts and washer including cutting holes of requisite size in the floor / base, grouting the bolts and mending good all damages- complete as per direction of Engineer-in-Charge.
2
1289
644.98
Extra rate add @ 7 % on every items from Sl. no-6.01 to 6.21 excluding item nos. 4.01, 4.02, 4.12, 4.13, 4.14, 4.15, 4.20, 4.21 (for Uttar Dinajpur District)
1
981
981.68
GST @18%
1
8308
8308.75
Labour Welfare Cess @ 1%
1
544
544.68
Total value of Internal wiring
1
55013
55013.17
Evaluation Notes How It Works ?