Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date17 Jan 2025
Closing Soon31 Jan 2025
Tender Amount₹ 25,25,435 
Notes
Download

Costs

Summary

Re-drilling, Installation And Development Of 2 Nos. Dtw Of Chakdaha Blocks Of Nadia District Under Kalyani (ai) Division Under Core Sector Programme For The Financial Year 2024-25.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(ii) beyond 90 metres and upto 120 metres.

30

1197

35926.5

... More
(iii) beyond 120 metres and upto 150 metres N.B. :- (a) The rates are inclusive of all reaming operations in case of Direct Circulation Rig. (b) For Siliguri Sub-Divn./ Alipurduar Sub-Division/ Malbazar Sub-Division /Chopra Block (under Uttar Dinajpur District) / Birbhum District / Purulia District / Bankura District / Paschim Medinipur District (except Ghatal, Daspur I & II Block), the above rates shall be enhanced by 10%. (c) In case the bore hole is decided to be abundoned by the competent authority due to non-availability of suitable thickness of aquifer capable of yielding desired discharge, the payment for abandoned bore hole shall be made (i) at 100% of the rates in case of drilling by Reverse Circulation Rig, and (ii) at 50% of the rates in case of drilling by Direct Circulation Rig. (d) Measurment will be taken below ground level taking ground level as zero for payment.

27

1206

32588.46

... More
Labour charges for lowering of ERW pipes, strainers, blank pipe etc. and fitting, fixing and jointing of tubewell assembly at site by welding in a manner as will be specified by the Engineer-in-charge. (i) 200 mm OD Bottom Plug

3

235

707.22

... More
(ii) 200 mm OD Slotted pipe

30

235

7072.2

... More
(iii) 200 mm OD Blank pipe

69

235

16266.06

... More
(iv) 350 mm OD Housing pipe

42

518

21782.04

... More
Supplying, fitting, fixing including fabrication with required materials (IS -2800 Part -I with latest amendments) as directed by the Engineer-in-charge and lowering in position etc. (i) 10 mm. thick (355.6 x 219) mm. M.S. OD Reducer of approved quality

1

3754

3754.83

... More
(ii) Centre guide (6 mm thick, 50 mm wide and 125 mm rise of arch) of approved size and quality.

23

231

5313.46

... More
(iii) M.S.Top cap of suitable size (8 mm thick) and approved quality for covering top of housing pipe of 355.6 mm OD (Top cap will be tack welded with housing pipe at 4 points 90° apart).

1

1073

1073.08

... More
(iv) 100 mm width × 12 mm thick Sockets / Wrings made from MS Flats by rolling process and double butt welding for jointing 355.6 mm OD Pipe.

6

721

4328.16

... More
(v) 75 mm width × 10 mm thick Sockets / Wrings made form MS Flats by rolling process and double butt welding for jointing 219 mm OD Pipe.

16

429

6864.64

... More
Supply of gravel for use as pack in tube well of 2 mm to 4 mm size (as per IS: 4097) for Gravel Treatment of Tube well including screening, washing, cleaning etc. of the Gravels at the site, all complete as per direction of Engineer-in-charge. (iii) For site at any district of West Bengal upto 180 km distance from quarry.

30.35

3885

117924.93

... More
Development of tubewell with 150 psi, 300 cfm Air-compressor and 2.5 cusec discharge capacity Vertical Trubine pump and carrying out step-drawdown test, yield test, verticality test and other tests as per prescribed method and as per direction of Engineer-in-Charge, including arranging, installing all equipments and testing instruments as required at site and dismantling the same after successful completion of tests, all complete. (ii) Depth upto 120 metre .

1

44525

44525

... More
Making slots of 75 mm X 1.60 mm size with a minimum clearance of 4.70 mm in between two adjacent slots over the outer surface of 219 mm OD ERW pipes (to be issued departmentally) in 10 (ten) rows (each row consisting of 96 slots) per metre length of ERW pipe with a clearance of 25 mm in between two rows as per drawing and specification including smoothening the edges after slotting,cost of transportation of ERW pipes from Departmental Store to Workshop and back to drilling site, loading, unloading and carrying by head-load where necessary both ways, all complete.

30

942

28288.5

... More
Mobilisation charges for transporting upto site including loading, unloading of all plants, machinaries & equipments required for drilling, development and testing of Tubewells and also the cost of construction temporary roads over field and / or culverts, repairing existing roads and / or culverts all complete, carrying materials on head load, carts or boats as the case may be :- (i) For sites within 4 km from all weather metal road.

1

7625

7625.24

... More
Electrologging of bore hole of different dia tubewell for locating water bearing strata and saline aquifer, if any, after conducting relevant geophysical tests. All test reports and compiled data sheets should be submitted to Engineer-in-Charge (cost is inclusive of all materials, labour & comilation of data sheets. The work should be done as per direction of Engineer-in-Charge including compilation of data.

1

8015

8015.08

... More
Add GST @ 18% :-

1

80511

80511.98

... More
Add CESS @ 1%:-

1

5278

5278.01

... More
PART - B: Supply and delivery of 350 mm nominal dia & 200 mm nominal dia E.R.W pipe Supply & delivery of 200mm. nominal outer dia M.S.E.R.W. Pipe of wall thickness 5.40 mm duly certification marked. Both Ends Plain. legth of Pipe should be as per I.S.Specification 4270/2001 with latest ammedments thereof. inclusive of all duties and taxes.

102

3214

327828

... More
Supply & delivery of 350mm. nominal outer dia M.S.E.R.W. Pipe of wall thickness 8.00 mm duly certification marked. Both Ends Plain. legth of Pipe should be as per I.S.Specification 4270/2001 with latest ammedments thereof. inclusive of all duties and taxes.

42

7007

294294

... More
Part-C: Maintenance of R.C.C pipe line in place of T. defunct one. Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m In ground floor including roof. (a) upto 150 mm. thick

3.6

939

3380.4

... More
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.

1

447

447

... More
Dismantling of Existing G.I. connection, Sluice valve, etc by mending good damages etc all complete.

1

752

752.47

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.

143.65

119

17133.14

... More
Repairing of leakages in collar joints of R.C.C. Pipe line by opening the joints fully by chipping out the old morter, cleaning the pipe recesses and collar properly, and thereafter positioning and levelling the pipes and collar, filling the annual spaces of joints with jute braiding dipped in cement slurry and grouting with (1:2) cement morter mixed with approved quality water proofing compound (5% by wt. of cement) and curing all complete as per direction of Engineer-in-Charge. 225 mm dia R.C.C Pipe.

40

67

2715.6

... More
Laying and joining of R.C.C. spun pipes with matching collars of different sizes mentioned below in field trenches including handling and carrying the pipes and matching R.C.C. collars from field stack, lowering the same within the trench, property positioning and levelling on bricks laid flat, filling the annular space between collar and the pipe joint with Jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved quality water proofing compound (5% by weioght of cement) and curing all complete as per direction of Engineer-in-Charge(cost of bricks for levelling and jute braiding are included). 1830 mm long 225 mm dia

146.4

32

4728.72

... More
Taking out the damaged R.C.C. Pipe and two collars by dismantling two joints carefully, carrying and stacking the same near the pump house, carrying new pipe and collars from the field stack, lowering the same within the trench, properly positioning and levelling on bricks laid flat, between collar and the pipe joints with jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved quality water proofing compound (5% by weight of cement) and curing all complete as per direction of Engineer-in-Charge. 225 mm dia R.C.C pipe

80

115

9278.4

... More
Taking out the condemmed 150 mm dia. N.T.P./T.P./ Alfa-Alfa valve from 150 mm dia. M.S./G.I. pipe of existing spout chamber by careful chiseling with least disburbance to the existing system of structure upto required limit and fitting, fixing of new one with 150 mm dia. M.S./G.I. pipe in proper position of the spout chamber using havoc zinc jute so as to make the joint leak proof including mending good all damages and returning back the condemned materials at store as per direction of Engineer-in-Charge.

10

81

810.9

... More
Jointing plain end of 300 mm / 200 mm / 150 mm. Dia. M.S. special bend from surge tanks / shore manifold with underground R.C.C. pipe lines of 450mm. / 300mm. / 225 mm. dia. by jamming with cement concrete (1:2:4) with 10 mm. down stone chips mixed with approved water proofing compound (5% by weight of cement) of adequate thickness to provide a leak proof joint including carrying the special bend from departmental store to site, curing etc. as per direction of Engineer-in-Charge.

3

83

251.76

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (iv) 150mm. dia. C.1.sluice valve

4

54

218.76

... More
(v) 150mm. dia. C.1.NTP/Alfa-Alfa valve.

12

54

656.28

... More
(vi) 300 mm /200 mm / 150mm. dia. M.S. special bend.

3

49

147.09

... More
(vii) 150mm. dia.90° M.S. bend with flanged ends

1

49

49.03

... More
(viii) 150mm. dia. M.S. riser pipe with flanged ends

12

49

588.36

... More
(iii) 80 mm dia 3 Mtrs long G.I.Pipe with one end flanged.

1

54

54.69

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

118.78

77

9210.2

... More
Single Brick Flat Soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

118.52

361

42785.72

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. a) Pakur Variety

14.6

5695

83150.8

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

4.92

5413

26631.96

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

138.29

736

101781.44

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners, as directed and racking out joints or roughening of concrete surface including throating, nosing and drip course as necessary at ground floor. (a) with (1:6) cement mortar. (ii) 15 mm. thick plaster.

424.28

151

64066.28

... More
Supplying fitting & fixing the following at site. Nuts & bolts different Size

16

140

2240

... More
(b) 150 mm dia Rubber Insertion (5 mm thick) with proper reinforcement 2 ply and standard 8 nos drilled hole equally spaced as per ISI 638/79 with latest amendments duly ISI marked suitable for M.S. Flange as per IS : 6392/71 with standard drilled holes (Table 11, 17.)

30

110

3300

... More
150 mm (NB) Standard M.S. Boss Flange duly ISI marked as per IS-6392/1971 (Table-6).

2

710

1421.4

... More
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.

424.28

34

14425.52

... More
Patch/Doubling works complete with M.S. plate including welding, gas cutting, fitting, fixing complete. (a) Cost of 5 mm M.S. plate including wastage due to cutting, including labour charges for straightening fitting, fixing in position.

0.29

3503

998.35

... More
(c) Electric welding charges of upto 8 mm M.S. plate M.S. channels etc. and other member of the barge including hiring charges of all tools and plants.

0.8

547

437.6

... More
Labour charges for clearing inside of 225 mm dia R.C.C. Pipeline by any suitable method like inserting bamboo or iron rope, as the case may be, by taking out RCC Pipes at 15 m intervals carefully dismantling Collar joints and mending good refixing the same after clearance of any silt, sand, iron incrustation or brick bats, etc.

105

38

4059.3

... More
Supplying, fitting & fixing of M.S. plate of size 40 cm x 40 cm, thickness 6 mm, consisting of two equal halves (40cm x 20cm), placed over Housing Pipe of HDTW/ MDTW to rest the supporting clamps, with semi circular hole of 170 mm dia. at centre including locking arrangement between the two halves on both sides, including fitting, fixing of 40 mm dia. G.!. bend by making a hole on plate for passing submersible cable smoothly and complete in all respect.

1

897

897.69

... More
GI Holding Clamp IS 1239, Galv - IS 4736, 150mm dia

2

3253

6506

... More
Painting with ready mixed Black Japan Paint of approved make and brand including smoothening surface. Two Coats

8.28

56

463.68

... More
Taking out the damaged R.C.C. Tee and 3 nos. collars by dismantling three joints carefully, carrying and stacking the same near the pump house, carrying new R.C.C. Tee and collars from the field stack, lowering the same within the trench, properly levelling and positioning on bricks laid flat, filling the annual space betwen pipe fitting and collars with jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved water proofing compound (5% by weight of cement) and curing etc. complete as per direction of Engineer-in-Charge. 225 mm x 225 mm x 150 mm R.C.C. Tee

6

148

893.94

... More
Jointing the undermentioned R.C.C. pipe fittings (pipeline specials) in the R.C.C. pipe line with matching RC.C. collars including handling and carryingthe fittings and matching R.C.C. collars from field stack, lowering in thetrenches, properly levelling and positioning on bricks laid flat, filling the annularspace between pipe fitting and collars with Jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved waterproofing compound (5% by weight of cement) and curing etc. complete as perdirection of the Engineer-in-Charge (Cost of bricks for levelling and Jute braiding are included). (iii) 225 mm x 225 mm x 225 mm. R.C.C. Tee

2

58

116.92

... More
(iv) 225 mm x 225 mm x 150 mm. R.C.C. Tee

4

57

230.08

... More
Add : Water transmisssion arrangement @ 3%

1

11008

11008.35

... More
Add GST @ 18%

1

72426

72426.68

... More
Add CESS @ 1%

1

4888

4888.41

... More
Part-D: Supply and delivery of accessories towards repair of Pipe Line to be drilled in place of T.defunct one NP-2 class 225 mm bore dia R.C.C spun pipe of length 1.83 Mtr, thickness 25 mm with matching collar as per IS: 458/1988 with latest amendments thereof including all taxes and transportation cost, etc.

78

1887

147186

... More
NP-2 class 225 mm bore dia R.C.C Collar of length 0.15 mtr., thickness 25 mm as per IS: 458/1988 with latest amendments thereof including all taxes and transportation cost, etc.

50

249

12450

... More
NP-2 Class 225 mm x 225 mm x 150 mm dia. R.C.C Tee of lenth 0.90 mtr. For 225 mm bore dia sides and 0.20 mtr. For 150 mm bore dia side as per IS : 458/1988 with amendments thereof.

6

1801

10806

... More
MS Surge Tank as per Drawing (Annexure-H), the body of which made of 3mm thick MS sheet and Top and Bottom cover are made of 5 mm thick MS sheet welded with the body and strengthened with ribs, etc. All joints must be electrically welded to a leak-proof condition and joints must be capable of withstanding pressure of 50 psi. The Surge Tank should be fitted with all accessoriesas specified in the drawing. Entire Surge Tank is to be painted both inside and outside over a coat of priming.

1

12041

12041

... More
80 mm dia M.S. Surge Pipe of 3 metre long made from 80 mm NB ERW pipe conforming to IS 1234 (Pt-1), 2004, Medium quality one end 80 mm flange welded of 10 mm thickness conforming to IS: 6392/71, Table-17.

1

3066

3066.73

... More
C.I.N.T.P. Valve as per Drawing (Annexure-E) with MS Spindle and weight of the bottom disc to be fitted with rubber washer washer which will be fitted tightly at the closing of NTP Valve. There should be arrangement of square type key holder made of MS, complete including two course of painting over a coat of priming. Approximate weight 20 Kg excluding key.

11

2669

29359

... More
Supply & Delivery of 150 mm (4.8 mm thick) Galv MS flanged pipe ISI marked IS 1239 Galv - IS4736

36

3800

136800

... More
150 mm Nominal size (PD) ISI marked Sluice Valve Pressure Designation P.N. 1.6 with Hand Wheel for water works purpose, C.I. Flange type conforming to IS-14846/2000 with amendment no. 1 & 2. Components/parts of Sluice Valve shallbe manufactured from basic materials given in table-1 of IS-14846/2000 with amendment no. 1 & 2. The Valve shall be tested for (Close End Test) against hydrostatic test requirement.

4

9950

39800

... More
Nuts & bolts different Size

20

140

2800

... More
GI 90 degree GI bend both end flanged ISI marked IS 1239, Galv - IS 4736, 150mm dia

1

8175

8175

... More
Part-E: Repairing of damaged Pump house at DTW to be drilled in place of T.defunct one. Earthwork in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sand stone), including removing, spreading or stacking the spoils within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottoms, bailing out water as required complete. (a)Depth of excavation not exceeding 1,500 mm.

0.53

119

63.21

... More
Single Brick Flat Soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

7.11

361

2566.71

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

1

5413

5413

... More
(b) In superstructure, ground floor

0.5

5636

2818

... More
a) 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately) .( Chequering not required over concrete or painted surface).

2.5

263

657.5

... More
b) Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.

1.25

119

148.75

... More
125 mm. thick brickwork with 1st class bricks in cement mortar (1:4) in ground floor .

2.68

736

1972.48

... More
Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 15 cm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation.

0.11

77

8.53

... More
Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. (a) Pakur variety

1.28

5695

7289.93

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping using grey cement 35 mm thick

19.68

337

6632.16

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and racking out joints including throating,nosing and drip course,scaffolding/staging where necessary( Ground floor) (i) With (1:6) cement mortar (c) 15 mm. thick plaster.

48.64

151

7344.64

... More
Neat cement punning about 1.5 mm. thick in wall,dado, window, sills, floor,drain etc.

8.48

34

288.32

... More
Decorative cement based paint Inside

48

49

2352

... More
Decorative cement based paint Outside

41

49

2009

... More
A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. includingusing of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : (hi-gloss) -(iv) Two coats (with any shade except white)

7.5

72

540

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. (i) 75 mm. Dia

7

188

1316

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.B) UPVC Fittings: a) Plain Tee, (i) 75 mm. Dia.

2

102

204

... More
d) Shoe, (i) 75 mm. Dia.

2

78

156

... More
Add extra carriage by cart/boat/head load for Water transmission arrangement of DTW @3% extra over the scheduled rates

1

1251

1251.25

... More
Add GST @18%

1

7745

7745.69

... More
Add Cess @ 1%

1

507

507.77

... More
Part-F: Supply and delivery of Submersible Pump & Motor Set for installation of DTW to be drilled in place of T.defunct one. Submersible pump motor sets ISI marked as per IS 8034 for pump and IS 9283 for motor read with latest amendments (150-115 Cum/Hr 17-28m) 20 HP with 150 mm outlet (350 mm)

1

111292

111292

... More
Supply & Delivery of 3c x 6mm2Copper PVC Insulated (Heavy Duty) weather proof Flat Electric Cables suitable for working upto and including 1100Volts duly ISI MARKED as per IS No. 694/1990 and latest amendments

125

352

44000

... More
20 HP electromagnetic star delta motor controllers with 4 pole heavy duty power controller single phasing preventor and normal protective

1

24700

24700

... More
Supply & delivery of Switch Fuse Unit ISI msrked IS 60947, 63 Amp Switch Fuse Unit TPN

1

8418

8418

... More
Part-G: Supply and Delivery of Accessories for lowering Submersible Pump and Motor Set for installation of HDTW to be drilled in place of T. defunct one Galv M5 column pipe ISI marked IS 1239 Galv - IS 4736, 150 mm dia one end screwed & other end non standard flange 3 m long (Bottom).

1

12218

12218

... More
Galv M5 column pipe ISI marked IS 1239 Galv - IS 4736, 150mm dia both end non standard flanged 3 m long (Middle)

8

13058

104464

... More
Galv M5 column pipe ISI marked IS 1239 Galv - IS 4736, 150mm dia one end standard & other end non standard flanged 3 m long (Top)

1

13461

13461

... More
90 degree GI bend both end flanged ISI marked IS1239 Galv IS 4736, 150 mm dia.

1

8175

8175

... More
Nuts & bolts different Size

15

140

2100

... More
PART - H:- Internal Wiring:- Drawing sub-merssible cable of motor & pump through 40 mm dia. Standard P.V.C pipe for DTW/HDTW(newly drilled) to Starter making necessary connection & also drawing 8 SWG G.I. wire for earthing attachment at existing pump house including cost of cutting/laying the pipe below ground level of average 1 mtr. depth.

15

43

645

... More
Supplying & fitting E.I danger board on wall. 20 cm x 30 cm (8" x 12")

2

85

170

... More
M.S. Structural works….less than 22.50kg/m

16

72

1161.65

... More
Meter loop connection with 1.1 K.V. Gr. 3½ core 25 sq. mm. P.V.C insulated & sheathed and armoured cable from Meter to incoming Main Switch/Terminal copper cable

2

330

660.06

... More
Earthing with 50 mm. dia GI pipe 3.64 mm thick × 3.04 mts long and 1 × 4 SWG G.I. (Hot Dip) wire (4 mts. Long), 13 mm dia. × 80 mm. long G.I. bolts, double nuts, double washers including supplying and fixing 15 mm. dia G.I. Pipe protection (1 mt. long) to be filled with bitumen, partly under the ground level and partly above the ground level, driven to an average depth of 3.65 metre below the ground level and restoring the surface duly rammed as below: (For soft soil). By ISI-Medium GI pipe

2

1369

2738

... More
Supplying and fixing earth busbar of galvanized (Hot Dip) M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes on the busbar complete with G.I. bolts, nuts, washers spacing insulators etc. as required.

0.5

156

78

... More
Connecting the equipments to earth busbar including supplying and fixing G.I.(Hot Dip) Wire of size as below on wall/floor with stapples buried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good damages. No. 8 SWG

14

9

126

... More
Supplying, and fixing sheet steel Main Switchs on Iron legs on wall 240 Volt D.P. with fuse on L & N, 15/16 Amps Havells. .

1

576

576

... More
Distribution wiring in 1.1 KV grade 2x 22/0.3 (1.5 sq mm) single core standard 'FR' PVC insulated and unsheathed copper wire (approved make) in suitable size PVC casing-capping (Precision make) with 1x22/0.3(1.5sqmm)single core standard 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on sheet steel fabricated switch board with bakelite/perspex (wall matching colour) top cover 3 mm thick on wall including necessary connections and making earthing attachment and mending good the damages to building works. A) average run 8 mts

5

849

4245

... More
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sq mm) single core standard 'FR' PVC insulated and unsheathed copper wire (approved make) in suitable size PVC casing-capping (Precision make) with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC including necy. PVC clips, fittings, etc. to 5A 3 pin flush type plug socket & Piano Key type switch (Anchor make) fixed on steel fabricated M.S. C.R.C.sheet metal (16 SWG) switch board cum J.B on wall including bakelite/perspex (wall matching colour) top cover 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment and incl. painting the MS box and mending good the damages to original finish of building works. [PVC casing-capping and plug box both on surface] A) On Board

1

67

67

... More
Supplying and fixing out door type CFL luminaire (Bajaj make-524020/020168 with epaxy power coated sheet alu,imium housig,aluminium reflector & cleat acrylic cover and accessories inclu. For 11/13 walls cfl s/l type including S&F 15 mm dia. G.I. pipe bracket clamp nuts & bolt and fixing 250 V, 100 Amp Lamp as per direction of E.I.C.

2

1138

2276

... More
Angular batten holder…….wall/cutting.

1

38

38

... More
Fixing only Iron Clad / Sheet Steel Main switches /Isolators on Iron Legs/Flat Iron Frame/Angle Iron Frame on wall. a) 63 Amps On angle iron frame 500V DP

1

215

215

... More
b) 20 H.P Oil Immersed Starter

1

240

240.45

... More
Fixing Voltmeter/Ammeter/Energy meter with necessary screws & other fixing materials & making holes where necessary including making connections. a) 0-50 Amp Ammeter

1

57

57

... More
b) 0-500 Voltmeter

1

57

57

... More
Distribution wiring in 1.1 KV single core strandaed 'FR' PVC insulated & unsheathed copper wire (approved make) in 20 mm size PVC rigid conduit 'FR' (precision Make) incl. necy. fittings as required in 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC in 20 mm Rigid conduit ( Domestic Main Switch Loop connection from pump controller to domestic Main Switch.)

2

119

238

... More
Add @ 2% (Except WRDD Schedule)

1

197

197.58

... More
Add GST @ 18%

1

2481

2481.43

... More
Add CESS @ 1%

1

162

162.67

... More
Part-I: Connection of Tube well assembly with Surge Tank by 150 mm dia 3 Meter long M.S. Connection Pipes including installation of Submissible Pump Motor at newly drilled HDTW in place of defunct one. Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.

3.79

119

452.03

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

1.67

361

602.87

... More
125mm thick brick work with 1st class bricks in cement mortar (1:4) , in ground floor

1.56

736

1148.16

... More
Brick work with 1st class bricks in cement mortar (1:6), (a) In foundation and plinth

7.86

5413

42546.18

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. a) Pakur Variety

0.8

5695

4556.21

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar, (c) 15 mm thick plaster

13.3

151

2008.3

... More
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.

13.3

34

452.2

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). (a) With earth obtained from excavation of foundation.

0.11

77

8.53

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of E.I.C. (i)(a) 150 mm. dia. pipe.

20

134

2696.8

... More
(i)(a) 150 mm. dia. Special Bend both end flanged

3

81

243.27

... More
Supplying, fitting and fixing the following materials at site. a) 20 mm x 50 mm nuts and bolts having approved standard thread (TATA) or approved make or 16 mm x 75 mm nuts and bolts or as per direction of Engineer-in charge

12

140

1680

... More
b) 150 mm dia rubber insertion with standard 8 Nos. drilled hole equally spaced (5 mm thick, reinforcement 2 Ply) as per I.S.I. 638 - 1965

12

110

1320

... More
c) 150 mm dia (OD 278 mm) 12 mm thick M.S. plate Flange with 8 Nos. drilled holes equally spaced.

4

710

2842.8

... More
Instalation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.) (a) 100/150/200 cubic metre per hour capacity electro motor pumping set. (i) Length of pump assembly of any length.

1

1510

1510.61

... More
(h) Jointing water proof cable with the leads of the motor including soldering with requisite water proof insulation and proper jointing compound/Valcanized rubber tape so that prope water proof insulation is assured.

2

150

300

... More
Installation / Erection of SurgeTank / Shore manifold (to be supplied from Deptt. free of cost) over a rigid base of ordinary cement concrete (1:2:4) with graded stone chips (20mm. nominal size) of pakur varity of 1250 mm X 1250mm X 150 mm. over a single layer of brick flat soling and embedding the legs of the surge tank/shore manifold within the concrete base including cost of all materials and labour and as per direction of Engineer-in-Charge.

1

2263

2263.08

... More
Add : Water transmisssion arrangement @ 3%

1

1749

1749.78

... More
Add GST @ 18% (except Supply item)

1

10896

10896.45

... More
Add CESS @ 1%

1

777

777.07



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.