Water Resources Development Directorate Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Civil And Construction
Eprocure
Opening Date20 Sep 2024
Closing Date21 Oct 2024
Tender Amount₹ 22,20,713 
Notes
Download

Costs

Summary

Re-drilling, Installation And Development And Connection Of Dtw/hdtw Of Size 355.6 Mm X 219.1 Mm O.d With Erw Pipe Including Construction/maintenance Of Pump House Including Wiring And Water Transmission System And Supply Of Necessary Materials At Va

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(iv) beyond 90 metres and upto 120 metres N.B. :- (a) The rates are inclusive of all reaming operations in case of Direct Circulation Rig. (b) For Siliguri Sub-Divn./ Alipurduar Sub-Division/ Malbazar Sub-Division /Chopra Block (under Uttar Dinajpur District) / Birbhum District / Purulia District / Bankura District / Paschim Medinipur District (except Ghatal, Daspur I & II Block), the above rates shall be enhanced by 10%. (c) In case the bore hole is decided to be abundoned by the competent authority due to non-availability of suitable thickness of aquifer capable of yielding desired discharge, the payment for abandoned bore hole shall be made (i) at 100% of the rates in case of drilling by Reverse Circulation Rig, and (ii) at 50% of the rates in case of drilling by Direct Circulation Rig. (d) Measurment will be taken below ground level taking ground level as zero for payment.

21

25148

1197.55

... More
Labour charges for lowering of ERW pipes, strainers, blank pipe etc. and fitting, fixing and jointing of tubewell assembly at site by welding in a manner as will be specified by the Engineer-in-charge. (i) 200 mm OD Bottom Plug

3

707

235.74

... More
(ii) 200 mm OD Slotted pipe

30

7072

235.74

... More
(iii) 200 mm OD Blank pipe

33

7779

235.74

... More
(iv) 350 mm OD Housing pipe

42

21782

518.62

... More
Supplying, fitting, fixing including fabrication with required materials (IS -2800 Part -I with latest amendments) as directed by the Engineer-in-charge and lowering in position etc. (i) 10 mm. thick (355.6 x 219) mm. M.S. OD Reducer of approved quality

1

3754

3754.83

... More
(ii) Centre guide (6 mm thick, 50 mm wide and 125 mm rise of arch) of approved size and quality.

18

4158

231.02

... More
(iii) M.S.Top cap of suitable size (8 mm thick) and approved quality for covering top of housing pipe of 355.6 mm OD (Top cap will be tack welded with housing pipe at 4 points 90° apart).

1

1073

1073.08

... More
(iv) 100 mm width × 12 mm thick Sockets / Wrings made from MS Flats by rolling process and double butt welding for jointing 355.6 mm OD Pipe.

6

4328

721.36

... More
(v) 75 mm width × 10 mm thick Sockets / Wrings made form MS Flats by rolling process and double butt welding for jointing 219 mm OD Pipe.

11

4719

429.04

... More
Supply of gravel for use as pack in tube well of 2 mm to 4 mm size (as per IS: 4097) for Gravel Treatment of Tube well including screening, washing, cleaning etc. of the Gravels at the site, all complete as per direction of Engineer-in-charge. (iii) For site at any district of West Bengal upto 180 km distance from quarry.

20.45

79458

3885.5

... More
Development of tubewell with 150 psi, 300 cfm Air-compressor and 2.5 cusec discharge capacity Vertical Trubine pump and carrying out step-drawdown test, yield test, verticality test and other tests as per prescribed method and as per direction of Engineer-in-Charge, including arranging, installing all equipments and testing instruments as required at site and dismantling the same after successful completion of tests, all complete. (ii) Depth beyond 120 metre and upto 200 metre.

1

44525

44525

... More
Making slots of 75 mm X 1.60 mm size with a minimum clearance of 4.70 mm in between two adjacent slots over the outer surface of 219 mm OD ERW pipes (to be issued departmentally) in 10 (ten) rows (each row consisting of 96 slots) per metre length of ERW pipe with a clearance of 25 mm in between two rows as per drawing and specification including smoothening the edges after slotting,cost of transportation of ERW pipes from Departmental Store to Workshop and back to drilling site, loading, unloading and carrying by head-load where necessary both ways, all complete.

30

28288

942.95

... More
Mobilisation charges for transporting upto site including loading, unloading of all plants, machinaries & equipments required for drilling, development and testing of Tubewells and also the cost of construction temporary roads over field and / or culverts, repairing existing roads and / or culverts all complete, carrying materials on head load, carts or boats as the case may be :- (i) For sites within 4 km from all weather metal road.

1

7625

7625.64

... More
Electrologging of bore hole of different dia tubewell for locating water bearing strata and saline aquifer, if any, after conducting relevant geophysical tests. All test reports and compiled data sheets should be submitted to Engineer-in-Charge (cost is inclusive of all materials, labour & comilation of data sheets. The work should be done as per direction of Engineer-in-Charge including compilation of data.

1

8015

8015.08

... More
Add GST @ 18% :-

1

63660

63660.42

... More
Add CESS @ 1%:-

1

4173

4173.29

... More
PART - B:- Connection of Tube well assembly with Surge Tank by 150 mm dia 3 Meter long M.S. Connection Pipes including installation of Submissible Pump Motor for DTW Centre. Instalation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.) (a) 100/150/200 cubic metre per hour capacity electro motor pumping set. (i) Length of pump assembly of any length exceeding 18 metre length.

1

1510

1510.61

... More
Withdrawal of electro motor submersible pumping set of following capacities from within the tubewell housing pipe of the following length by using all necessary requisites tools and plants and carefully as per direction of Engineer-in-Charge and stacking the same properly at site within the tubewell premises complete. (a)100/150/200 cubic metre per hour capacity electro motor pumping set. (i) Length of pump assembly of any length exceeding 18 metre length.

1

1045

1045.73

... More
Jointing water proof cable with the leads of the motor including soldering with requisite water proof insulation and proper jointing compound/Valcanized rubber tape so that prope water proof insulation is assured.

2

198

99.01

... More
Supplying, fitting and fixing PVC pipes for underground work of approved make (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.). i] PVC pipe a]32 mm dia pipe.

20

5000

250

... More
Supplying, fitting fixing of M.S. Plate 6 mm thick of size 40 cm x 40 cm over housing pipe to rest the clamp with semi circular holes at centre 16 mm dia including fitting fixing of G.I. pipe, elbow, nipple of 40 mm dia for insertion of submersible cable including cost of nuts & bolts, 1 Mtr G.I. pipe of dia 25 mm, elbow, nipple etc. all complete.

1

897

897.69

... More
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq.mtr and above. For supplying fitting and fixing pump protector having outer dia 250 mm, height 250 mm made with 5 nos. vertical member of Indian standard angle (40x40x5 mm), 16 mm dia. M.S. Rod (at top and bottom ) & 25 mm x 6 mm M.S. flat as per direction including cost of labour and materials, welding all complete.

0.1

921

9696

... More
Dismantling the existing G.I./M.S. Delivery Pipe line connection between the existing D.C./Surge Tank/Tripod Set & Tube Well assembly viz Sluice valve, Bend, Surge Tank/Distribution Chamber /Tripod Set Connection pipe etc.and disconnection of delivery side viz. Special bend etc. all complete as per direction of the E.I.C. and stacking all serviceable materials at site.

1

752

752.47

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of E.I.C. (i)(a) 150 mm. dia. ERW pipe.

21

2831

134.84

... More
(i)(a) 150 mm. dia. Special Bend both end flanged

2

162

81.09

... More
Patch/Doubling works complete with 5 mm M.S. plate including welding, gas cutting, fitting, fixing complete. (a) Cost of 5 mm M.S. plate including wastage due to cutting, including labour charges for straightening fitting, fixing in position. .

0.36

1261

3503

... More
(b) Gas cutting to required size of 5 mm thick M.S. plate NSC channel etc. including labour charges, hire charges for all tools and plants.

4.24

992

234

... More
(c) Electric welding charges of 5 mm M.S. plate M.S. channels etc. and other member including hiring charges of all tools and plants.

4.24

2319

547

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.

4.84

577

119.27

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

3.37

1101

327

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. a) Pakur Variety

0.34

1905

5605.86

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

2.34

11587

4952

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar. (c) 20 mm thick plaster

10.5

1732

165

... More
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.

10.5

357

34

... More
Jointing plain end of 300 mm / 200 mm / 150 mm. Dia. M.S. special bend from surge tanks / shore manifold with underground R.C.C. pipe lines of 450mm. / 300mm. / 225 mm. dia. by jamming with cement concrete (1:2:4) with 10 mm. down stone chips mixed with approved water proofing compound (5% by weight of cement) of adequate thickness to provide a leak proof joint including carrying the special bend from departmental store to site, curing etc. as per direction of Engineer-in-Charge..

2

167

83.92

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

14.13

409

29

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. includingusing of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : (other than hi-gloss) - (i) Two coats (with any shade except white)

14.13

1017

72

... More
c) 150 mm dia (OD 278 mm) 12 mm thick M.S. plate Flange with 8 Nos. drilled holes equally spaced.

5

3553

710.7

... More
Add : Water transmisssion arrangement @ 3%

1

721

721

... More
Add GST @ 18% :-

1

7384

7384.3

... More
Add CESS @ 1%:-

1

484

484.08

... More
PART - C:- Internal Wiring:- Drawing sub-merssible cable of motor & pump through 40 mm dia. Standard P.V.C pipe for DTW/HDTW(newly drilled) to Starter making necessary connection & also drawing 8 SWG G.I. wire for earthing attachment at existing pump house including cost of cutting/laying the pipe below ground level of average 1 mtr. depth.

15

645

43

... More
Supplying & fitting E.I danger board on wall. 20 cm x 30 cm (8" x 12")

2

170

85

... More
M.S. Structural works….less than 22.50kg/m

16

1161

72.6

... More
Meter loop connection with 1.1 K.V. Gr. 3½ core 25 sq. mm. P.V.C insulated & sheathed and armoured cable from Meter to incoming Main Switch/Terminal copper cable

2

660

330.03

... More
Earthing with 50 mm. dia GI pipe 3.64 mm thick × 3.04 mts long and 1 × 4 SWG G.I. (Hot Dip) wire (4 mts. Long), 13 mm dia. × 80 mm. long G.I. bolts, double nuts, double washers including supplying and fixing 15 mm. dia G.I. Pipe protection (1 mt. long) to be filled with bitumen, partly under the ground level and partly above the ground level, driven to an average depth of 3.65 metre below the ground level and restoring the surface duly rammed as below: (For soft soil). By ISI-Medium GI pipe

2

2738

1369

... More
Supplying and fixing earth busbar of galvanized (Hot Dip) M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes on the busbar complete with G.I. bolts, nuts, washers spacing insulators etc. as required.

0.5

78

156

... More
Connecting the equipments to earth busbar including supplying and fixing G.I.(Hot Dip) Wire of size as below on wall/floor with stapples buried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good damages. No. 8 SWG

14

126

9

... More
Supplying, and fixing sheet steel Main Switchs on Iron legs on wall 240 Volt D.P. with fuse on L & N, 15/16 Amps Havells. .

1

576

576

... More
Distribution wiring in 1.1 KV grade 2x 22/0.3 (1.5 sq mm) single core standard 'FR' PVC insulated and unsheathed copper wire (approved make) in suitable size PVC casing-capping (Precision make) with 1x22/0.3(1.5sqmm)single core standard 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on sheet steel fabricated switch board with bakelite/perspex (wall matching colour) top cover 3 mm thick on wall including necessary connections and making earthing attachment and mending good the damages to building works. A) average run 8 mts

5

4245

849

... More
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sq mm) single core standard 'FR' PVC insulated and unsheathed copper wire (approved make) in suitable size PVC casing-capping (Precision make) with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC including necy. PVC clips, fittings, etc. to 5A 3 pin flush type plug socket & Piano Key type switch (Anchor make) fixed on steel fabricated M.S. C.R.C.sheet metal (16 SWG) switch board cum J.B on wall including bakelite/perspex (wall matching colour) top cover 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment and incl. painting the MS box and mending good the damages to original finish of building works. [PVC casing-capping and plug box both on surface] A) On Board

1

67

67

... More
Supplying and fixing out door type CFL luminaire (Bajaj make-524020/020168 with epaxy power coated sheet alu,imium housig,aluminium reflector & cleat acrylic cover and accessories inclu. For 11/13 walls cfl s/l type including S&F 15 mm dia. G.I. pipe bracket clamp nuts & bolt and fixing 250 V, 100 Amp Lamp as per direction of E.I.C.

2

2276

1138

... More
Angular batten holder…….wall/cutting.

1

38

38

... More
Fixing only Iron Clad / Sheet Steel Main switches /Isolators on Iron Legs/Flat Iron Frame/Angle Iron Frame on wall. a) 63 Amps On angle iron frame 500V DP

1

215

215

... More
b) 20 H.P Oil Immersed Starter

1

240

240.45

... More
Fixing Voltmeter/Ammeter/Energy meter with necessary screws & other fixing materials & making holes where necessary including making connections. a) 0-50 Amp Ammeter

1

57

57

... More
b) 0-500 Voltmeter

1

57

57

... More
Distribution wiring in 1.1 KV single core strandaed 'FR' PVC insulated & unsheathed copper wire (approved make) in 20 mm size PVC rigid conduit 'FR' (precision Make) incl. necy. fittings as required in 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC in 20 mm Rigid conduit ( Domestic Main Switch Loop connection from pump controller to domestic Main Switch.)

2

238

119

... More
Add @ 2%

1

197

197.58

... More
Add GST @ 18%

1

2481

2481.43

... More
Add CESS @ 1%

1

162

162.67

... More
PART - D:- Maintenance of water transmission system ( WTA ) for DTW Centre :- Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm. thick

0.63

591

939

... More
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.

1.52

679

447

... More
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.

5.04

95

19

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.

39.74

4739

119.27

... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand.

11.72

7684

655.71

... More
Single Brick Flat Soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

175.03

57234

327

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works . (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. ( Upto roof of ground floor )

53.38

17615

330

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. a) Pakur Variety

17.6

98663

5605.86

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth(G.Floor)

2.21

10943

4952

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

141.91

96356

679

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (a) 20 mm thick plaster [Gr floor )

75.06

12384

165

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (a) 15 mm thick plaster [Gr floor )

363.88

52398

144

... More
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

438.94

14923

34

... More
Carriage of Departmental materials from the Deparmental Store to the work site and return back the damaged/replaced and unused materials to store including loading & unloading complete at both sides by Tempo/Van Rikshaw/Mini Truck etc. upto 25 Km distance in one way. i) For Delivery pipe, Surge Tank, Bend, Valve etc.

1

905

905.23

... More
Earth work in excavation of field trenches as per designed section & alignment for laying of pipe lines (PVC, RCC, ACP etc) upto a depth of 1500 mm in all sorts of soils including removing, spreading or stacking extra earth as directed. The item includes necessry trimming of sides trenches, levelling, dressing and ramming the bottom as required complete.

146.25

14480

99.01

... More
Taking out the damaged R.C.C. Pipe and two collars by dismantling two joints carefully, carrying and stacking the same near the pump house, carrying new pipe and collars from the field stack, lowering the same within the trench, properly positioning and levelling on bricks laid flat, between collar and the pipe joints with jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved quality water proofing compound (5% by weight of cement) and curing all complete as per direction of Engineer-in-Charge. i) 225 mm dia. R.C.C. Pipe.

55

6378

115.98

... More
Taking out the damaged R.C.C. Tee and 3 nos. collars by dismantling three joints carefully, carrying and stacking the same near the pump house, carrying new R.C.C. Tee and collars from the field stack, lowering the same within the trench, properly levelling and positioning on bricks laid flat, filling the annual space betwen pipe fitting and collars with jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved water proofing compound (5% by weight of cement) and curing etc. complete as per direction of Engineer-in-Charge. (i) 225 mm × 225 mm × 150 mm R.C.C. Tee.

1

148

148.99

... More
(ii) 225 mm × 225 mm × 225 mm R.C.C. Tee.

1

162

162.19

... More
Taking out the condemmed 150 mm dia. N.T.P./T.P./ Alfa-Alfa valve from 150 mm dia. M.S./G.I. pipe of existing spout chamber by careful chiseling with least disburbance to the existing system of structure upto required limit and fitting, fixing of new one with 150 mm dia. M.S./G.I. pipe in proper position of the spout chamber using havoc zinc jute so as to make the joint leak proof including mending good all damages and returning back the condemned materials at store as per direction of Engineer-in-Charge.

5

405

81.09

... More
Removing of Chokage due to sludge, mud, sand or any other forign materials deposition from the underground 450 / 300 / 225/ 150 mm dia. R.C.C. Pipe Line with split bamboo, wire brush, coir rope etc. along with suitable cleaning agent as ecessary as per direction of E.I.C. (This item includes cost of earth cutting & back filling of trenches and required materials for cleaning but excluding the cost for taking out one full length of RCC Pipe by dismantling of 2 nos. of Collars & refitting the RCC pipe with new two nos. collar). i) For 225 mm dia. RCC Pipe

150

5799

38.66

... More
Repairing of leakages in collar joints of R.C.C. Pipe line by opening the joints fully by chipping out the old morter, cleaning the pipe recesses and collar properly, and thereafter positioning and levelling the pipes and collar, filling the annual spaces of joints with jute braiding dipped in cement slurry and grouting with (1:2) cement morter mixed with approved quality water proofing compound (5% by wt. of cement) and curing all complete as per direction of Engineer-in-Charge. (a) 225 mm dia. R.C.C. Pipe.

10

678

67.89

... More
Jointing the under mentioned R.C.C pipe fittings(pipe line specials) in the R.C.C pipe line with matching R.C.C Collars including handling and carrying fittings and matching R.C.C Collars from field stack, lowering in the trenches properly leveling and positioning on bricks laid flat, filling the annular space between pipe fitting and collars with jute braiding dipped in cement slurry, grouting with cement and sand mortar(1:2) mixed with approved water proofing compound(5% by weight of cement0 and curing etc. complete as per direction of the Engineer-In- Charge(cost of bricks for leveling and jute braiding are included). (i) 225 mm × 225 mm × 225mm R.C.C. Tee.

1

58

58.46

... More
(ii) 225 mm × 225 mm × 150mm R.C.C. Tee.

2

115

57.52

... More
(iii) 225 mm R.C.C. Bend.

1

57

57.52

... More
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i) 150mm. dia. C.1.sluice valve

3

164

54.69

... More
Earth work in filling in trenches after laying pipe lines (PVC, RCC, ACP etc) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, ncluding watering & ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished quantity of work.)

136.38

9002

66.01

... More
Supplying, fitting & fixing including transportation of sign board for identifying the exact location of MINI RLI scheme ( one at road side and other at site ) the board will be made 3 mm thick MS Plate of size 300mm X 600mm and fitted and fixed on 50mm GI pipe of IS 1239/90 (Part-I) including cutting, welding and writting of both sides of sign board . Base - Yellow and Words - Red. Both Bottom end of the stands pipe will be grouted in 1:2:4 CC on single brick flat soling. This will include one materials and labour complete as per Drawing & direction of E.I.C.

1

3677

3677.51

... More
Add Water transmission arrangement @ 3%

1

11234

11234.71

... More
Add GST @ 18%

1

76964

76964.73

... More
Add CESS @ 1%

1

5045

5045.47

... More
PART - E:- Repair and maintenance of Pump House for DTW Centre :- Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared).

330

3630

11

... More
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof.

2.72

5320

1956

... More
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m . a) In ground floor including roof.

4.41

1971

447

... More
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm. thick

1.08

1014

939

... More
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.

60.6

1151

19

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.

41.95

13843

330

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. (a) Pakur variety

3.33

20486

6152.12

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (i) Tor steel/Mild Steel a) For works in foundation and upto roof of ground floor/ upto 4 m II. Other than SAIL/ TATA / IRINL

0.3

16331

54439.07

... More
Earthwork in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sand stone), including removing, spreading or stacking the spoils within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottoms, bailing out water as required complete. (a)Depth of excavation not exceeding 1,500 mm.

0.98

116

119.27

... More
Single Brick Flat Soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

12.96

4237

327

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. (a) Pakur variety

2.42

13566

5605.86

... More
125 mm. thick brickwork with 1st class bricks in cement mortar (1:4) in ground floor .

14.42

9791

679

... More
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure ground floor

0.38

1966

5174

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and racking out joints including throating,nosing and drip course,scaffolding/staging where necessary( Ground floor) (i) With (1:6) cement mortar (a) 20 mm. thick plaster.

36

5940

165

... More
(i) With (1:6) cement mortar (b) 15 mm. thick plaster.

73.61

10599

144

... More
(i) With (1:6) cement mortar (b) 10 mm. thick plaster.

14.4

1843

128

... More
Neat cement punning about 1.5 mm. thick in wall,dado, window, sills, floor,drain etc.

14.45

491

34

... More
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.

3.48

4537

1304

... More
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing aove 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.

0.17

1680

9888

... More
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq.mtr and above . & (b) Extra for work in grill gate. (I) For hanging and locking arrangements including supply of materials and labour complete. (15% extra over the corresponding item of grill ) ( In including locking arrangement )

0.89

9923

11150

... More
Scraping and removing greasy sootfrom walls or ceiling of kitchen or similar smoke affected rooms and preparing the surface.

12.5

137

11

... More
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. [Gr floor ) i) Two coats

131.16

6426

49

... More
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

8.74

253

29

... More
A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. includingusing of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)

8.74

629

72

... More
Painting block letters or digits in Black Japan or any approved paint as per direction

160

1760

11

... More
Add : Water transmisssion arrangement @ 3%

1

3729

3729.3

... More
Add GST @ 18%

1

25448

25448.51

... More
Add CESS @ 1%

1

1668

1668.29

... More
PART - F:- Procurement of different Type of materials for DTW Centre :- Supply & delivery of 200mm. nominal outer dia M.S.E.R.W. Pipe of wall thickness 6.40 mm duly certification marked. Both Ends Plain. legth of Pipe should be as per I.S.Specification 4270/2001 with latest ammedments thereof. inclusive of all duties and taxes.

66

212124

3214

... More
Supply & delivery of 350mm. nominal outer dia M.S.E.R.W. Pipe of wall thickness 8.00 mm duly certification marked. Both Ends Plain. legth of Pipe should be as per I.S.Specification 4270/2001 with latest ammedments thereof. inclusive of all duties and taxes.

42

294294

7007

... More
Supply & Delivery of 150 mm (N.B.) (166.5 mm O.D.) GI MS flange pipe, 3.00 M long duly ISI certification marked as per IS: 1239(Part-I)/2004 with latest amendments, thereof, wall thickness 4.80 mm & both end welded with 12 mm thick standard flange.

21

79800

3800

... More
90 degree G.I Bend (both end flanged - ISI marked - IS 1239, Galv- IS4736 :- Supplyand delivery of 150 mm dia long bend (with priming)

2

16350

8175

... More
C.I N.T.P. Valve as per Drawing (Annexure-E) with MS Spindle and weight of the bottom disc to be fitted with rubber washer washer which will be fitted tightly at the closing of NTP Valve. There should be arrangement of square type key holder made of MS, complete including two course of painting over a coat of priming. Approximate weight 20 Kg excluding key.

5

13345

2669

... More
150 mm Nominal size (PD) ISI marked Sluice Valve Pressure Designation P.N. 1.6 with Hand Wheel for water works purpose, C.I. Flange type conforming to IS-14846/2000 with amendment no. 1 & 2. Components/parts of Sluice Valve shallbe manufactured from basic materials given in table-1 of IS-14846/2000 with amendment no. 1 & 2. The Valve shall be tested for (Close End Test) against hydrostatic test requirement.

3

29850

9950

... More
Galv. M S Column pipe, ISI mar ed -1239, Galv- IS4736 :- Supplyand delivery of 150 mm dia one end screwed & non-std flange 3 mt long (bottom)

1

12218

12218

... More
Galv. M S Column pipe, ISI mar ed -1239, Galv- IS4736 :- Supplyand delivery of 150 mm dia both end with non-std lange 3 m long (middle)

6

78348

13058

... More
Galv. M S Column pipe, ISI mar ed -1239, Galv- IS4736 :- Supplyand delivery of 150 mm dia one end std& other en non std flange (top) 3m long (middle)

1

13461

13461

... More
M.S / G.I. Holding Clamp :- Supply of GI Holding Clamp IS 1239, Gavl- IS4736, :- 150 mm dia.

1

3253

3253

... More
Nuts & Bolts (G.I) :- Supplying, fitting and fixing the following materials at site - a) 20 mm x 100 mm nuts and bolts having approved standard thread approved make or 16 mm x 80 mm nuts and bolts or as per direction of Engineer-in charge

36

5040

140

... More
Supply and Delivery of Submersible Pump sets, ISI Marked - as per IS 8034 for Pump and IS: 9283 for motor ( Read with latest ammendment for all IS ). a) (180 - 125 m3 / Hr , 20 - 35 m ) ( 25 HP ) with 150 mm outlet ( 350 mm )

1

120578

120578

... More
Supply & Delivery of 3c x 6mm2Copper PVC Insulated (Heavy Duty) weather proof Flat Electric Cables suitable for working upto and including 1100Volts duly ISI MARKED as per IS No. 694/1990 and latest amendments

100

35200

352

... More
Supply and delivery of MOTOR CONTROLLER, IS 60947 3Q electromagnetic Star- Delta starters for 25HP motor

1

27820

27820

... More
Supplyand delivery of ' Sheet Metal Enclosure 415 volt, 3 Phase,50 Cycles(Hz)with rewireable type T.P. Fuse T.P.N Main V Switch 63 Amp A.C. conforming to IS: 60947.

1

8418

8418

... More
b) 150 mm dia rubber insertion with standard 8 Nos. drilled hole equally spaced (5 mm thick, reinforcement 2 Ply) as per I.S.I. 638 - 1965

30

3300

110

... More
NP-2 class 225 mm bore dia R.C.C spun pipe of length 1.83 Mtr, thickness 25 mm with matching collar as per IS: 458/1988 with latest amendments thereof including all taxes and transportation cost, etc.

55

99990

1818

... More
NP-2 class 225 mm bore dia R.C.C Collar of length 0.15 mtr., thickness 25 mm as per IS: 458/1988 with latest amendments thereof including all taxes and transportation cost, etc.

10

2410

241



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.