Water Resources Development Directorate Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date30 Jan 2024
Closing Date12 Feb 2024
Tender Amount₹ 16,35,608 
Notes
Download

Costs

Summary

Renovation Of Kurmile Dtw Under Balurghat Block Through Redrilling Installation Renovation Of Wta Pump House Replacement Of Submersible Pump Motor Set Electrical Accessories Supply Of Material Under Balurghat Ai Subdivn Balurghat Ai Divn Raiganj A

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 150 mm nominal size (PD) ISI marked sluice valve pressure designation PN 1.6 with hand wheel for water works purpose, CI flange type conforming to IS:14846/2000 with amendments nos. 1 & 2 components/parts of sluice valves shall be manufactured from basic materials given in table 1 of IS:14846/2000 with amendments 1 & 2. The valves should be tested for (closed end test) against Hydrostatic test requirement.

4

39800

9950

... More
Supply of 150 mm (NB) MS Special Bend both end flange welded. 150 mm (NB) ERW pipe should be conforming to IS1239(Part-I)/2004 medium and 12 mm nominal thickness MS Flange conforming to IS6392/1971, Table-17.

3

22050

7350

... More
MS Surge tank the body of which made of 3 mm thick MS sheet and bottom cover are made of 5 mm MS sheet welded with the body and strenghthen with rib etc. All joint must be electrically welded to a leak proof condition and joint must be capable of withstanding pressure of 50 PSI. The surge tank should be fitted with all accessories as specified in the drawing. Entire surge tank is to be painted both inside and outside over a coat of priming

1

14710

14710

... More
150 mm (NB) MS plate flange duly ISI marked as per IS 6392/ 1971

13

12649

973

... More
Supply of 150 mm dia NB column pipe (nominal wall thickness 4.8 mm) one end welded with non-standard flange and other end welded with standard flange (3.0 metre long) as per table and IS specification [Annexure-F & TSP-3]. TOP

1

13461

13461

... More
Supply of 150 mm dia NB column pipe (nominal wall thickness 4.8 mm) one end screwed and other end welded with non- standard flange (3.0 metre long) as per table and IS specification . BOTTOM

1

12218

12218

... More
Supply of 90° M.S. short bent made from 150 mm (NB) single pieces black steel tube ( medium) wall thickness 4.8 mm manufactured by means of electro resistance welding Bolt and welded with standard flange of thickness 16 mm OD 285 mm with 8 Nos. equally spaced 16 mm dia hole ERW pipe should conform to IS 1239 (Part-I)/ 1990 with latest ammendments thereof]

1

8175

8175

... More
Supply of 150 mm dia NB heavy duty supporting clamps in two halves made of M.S. flats for holding column pipes

1

3253

3253

... More
150 mm dia Alfa-Alfa Valve C type

15

66525

4435

... More
MS Hexagonal head bolts and nuts conforming to IS 1363 (Part-I)/1992 of product grade C with latest amendments for bolts & nuts are duly ISI certified mark. (Full threaded)

-

-

-

... More
M16 X 50

15

2550

170

... More
M16 X 65

25

4250

170

... More
M16 X 80

15

2550

170

... More
Supply and transport of Rubber Insertion 150 mm dia (NB) X 5 mm thick with proper reinforcement reinforced with 2 ply conforming to IS 638/1979 with latest amendment duly ISI mark suitable for MS flange as per IS 6392/1971 with standard drilled holes (Table No 5, 11, 17)

50

5450

109

... More
96 x 96 sq. mm Flush mounting Ameter (range 0-50/100 Amps) MIAC, Accuracy within ± 1.5% and confirming to IS: 1248/1968.

1

504

504

... More
96 x 96 sq. mm Flush mounting Voltmeter (range 0-500 Volts) MIAC, Accuracy within ± 1.5% and confirming to IS: 1248/1968.

1

504

504

... More
Sheet Metal enclosed re-wireable type Fuse, Main switch, 415 VLTS, 3 Phase, 50 Cycle AC Supply confirming to IS: 13947(Part-3)/1993. 100 Amps AC, TPN

1

15267

15267

... More
3 core 6 Sq.mm copper PVC insulated (Heavy Duty) Flat Weather proof Electric cable duly ISI certification mark as per IS 694/1990.

100

35200

352

... More
PART-B. Re-drilling and Installation of Heavy Duty Tube well:- Drilling of bore hole 55.88 cm dia through any kind of soil by adopting any method of drilling (by Direct or Reverse Circulation Rotary Rig) upto required depth including digging trenches and pits etc. all complete

-

-

-

... More
(i) Upto 30 metres below G.L.

30

35077

1169.26

... More
(ii) beyond 30 metres and upto 60 metres.

30

34794

1159.83

... More
(iii) beyond 60 metres and upto 90 metres

30

35360

1178.69

... More
(iv) beyond 90 metres and upto 120 metres

20

23951

1197.55

... More
Labour charges for lowering of M.S. E.R.W. pipes, strainers, blank pipe etc. and fitting, fixing and jointing of tubewell assembly at sites by welding etc. as per direction of the Engineer-in-Charge.

-

-

-

... More
(i) 200 mm NB Bottom plug

3

707

235.74

... More
(ii) 200 mm NB Strainer

30

7072

235.74

... More
(iii) 200 mm NB Blank pipe

28

6600

235.74

... More
(iv) 350 mm NB Housing pipe

39

20226

518.62

... More
Supplying, fitting, fixing including fabrication (IS -2800 Part -I with latest amendments) with required materials as directed by the Engineer-in-charge and lowering in position etc.

-

-

-

... More
(i) 10 mm. thick (350 mm x 200 mm) NB M.S. Reducer of approved quality including socket.

1

3754

3754.83

... More
(ii) M.S. Centre guide (consisting of 3 nos., 6 mm thick, 50 mm wide, not less than 600 mm long and 125 mm rise of arch) of approved quali!y

10

2310

231.02

... More
(iii) M.S.Top cap of suitable size (8 mm thick) and approved quality for covering top of housing pipe of 350 mm NB (Top cap will be tack welded with housing pipe at 4 points 900 apart).

1

1073

1073.08

... More
(iv) 100 mm width x 12 mm thick Sockets / Rings made from MS Flats by rolling process and double butt welding for joining 350 mm NB Housing Pipe

6

4328

721.36

... More
(v) 75 mm width x 10 mm thick Sockets / Rings made form MS Flats by rolling process and double butt welding for ioining_200 mm NB Pipe.

10

4290

429.04

... More
Supply of gravel for use as pack of tube well of 2mm to 4 mm size (as per IS: 4097) and gravel treatment including screening, washing, cleaning etc, all complete as per direction of Engineer-in-Charge. From sites within 4 km with all weather metal road

30

86970

2899

... More
Development of tubewell in accordance with IS: 2800 (part 1j and IS: 11189 to establish maximum rate of usable water yield without sand content beyond permissible limit with required capacity of compressor ( about 200 psi, 375 cfm Aircompressor, actual psi and cfm depend on tube well head conditions),running the compressor for required time till well is fully developed and followed by development of tube well by over pumping with 15% to 25% higher discharge than expected discharge of tube well capacity and Vertical Trubine pump and carrying out step-drawdown test, yield test, verticality test etc. as per prescribed method all complete including hire & labour charges of compressor,tools & accessories etc. all as per requirement and direction of Engineer -In -Charge.

-

-

-

... More
(i) Depth upto 120 metre

1

36469

36469

... More
Making slots of 75 mm X 1.60 mm size with a minimum clearance of 4.70 mm in between two adjacent slots over the outer surface of 200 mm NB ERW pipes (to be issued departmentally) in 10 (ten) rows (each row consisting of 96 slots) per metre length of ERW pipe with a clearance of 25 mm in between two rows as per drawing and specification including smoothening the edges after slotting,cost of transportation of ERW pipes from Departmental Store to Workshop and back to drilling site, loading, unloading and carrying by head-load where necessary both ways, all complete.

30

28288

942.95

... More
Mobilisation charges for transporting upto site including loading, unloading of all plants, machinaries and equipments required for drilling, development and testing of Tubewells and also the cost of construction of temporary roads over field and lor, culverts, repairing existing roads and I or culverts all complete,carrying materials on head load, carts or boats as the case may be :- (i) For sites within 4 km from all weather metal road.

1

7625

7625.64

... More
Electrologging of bore hole of different dia tubewell for locating water bearing strata and saline aquifer, if any, after conducting relevant geophysical tests. All test reports, compiled data and raw data sheets should be submitted to the Engineer-in-Charge (Cost is inclusive of all charges for equipments, labour, data aquisition & compilation of data sheets as per direction of the Engineer-incharge)

1

8015

8015.08

... More
Add GST @ 18% ( It 2-9)

1

62444

62444.81

... More
Add LABOUR Cess @ 1% (It 2-10)

1

4093

4093.6

... More
PART- C Construction of Pump house

-

-

-

... More
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils within a lead of 75 M as directed. The item includes necessary trimming the sides of the trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1.50 M.

10.55

1258

11927

... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (Payment to be made on the basis of measurement of finished quantity of work).

4.22

3002

71159

... More
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.

28.43

9209

324

... More
Brick work with first class bricks in cement mortar (1:6).

-

-

-

... More
(a) In foundation & plinth

1.32

6494

4919.88

... More
(b) In Superstructure, Ground Floor

9.21

47355

5142.88

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety

2.13

11832

5555.22

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

6.83

4605

674.33

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams,columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). b) 25 mm to 30 mm thick wooden shuttering as per decision and direction of E.I.C

73.69

24170

328

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4m (i) Tor steel/Mild Steel II. Other than SAIL/ TATA/RINL

0.82

46587

56953.46

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety (for 35 Km Distance)

8.7

52738

6061.92

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]

-

-

-

... More
(i) With 1:6 cement mortar (b) 20 mm thick plaster.

72.78

11837

162.65

... More
(i) With 1:6 cement mortar (c) 15 mm thick plaster

46.29

6549

141.48

... More
(ii) With 1:4 cement mortar (c) 10 mm thick plasterr

14.44

1826

126.48

... More
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In ground floor(Door & Window)

1.9

19304

10160

... More
Atificial stone in floor, dado,staircase etc. with cement concrete 1:2:4 laid in panels as directed with topping made with ordinary 0r white cement (as directed) and marble dust in proportion (1:20 including smooth finishing and rounding off concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sqm all complete including all materials and labour. 25 mm thick artificial stone flooring ( using grey cement ) In ground floor, 3 mm thick topping ( high polishing grinding on this item is not permitted with ordinary cement) Using grey cement (a) 35 mm thick.

14.44

4519

312.96

... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

14.7

480

32.72

... More
Supplying fitting and fixing of Mild steel Joist (150 mm x 80 mm x 6.8 mm) with RCC pillars at the roof of pump house for fitting device including hoisting and lifting.

47.14

3842

81.5

... More
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly ( plastered or concrete surface) as per manufacturer's specification.( Inside & Outside) iii) Two coats

133.51

6541

49

... More
a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

9.3

269

29

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With other than hi-gloss (hi-gloss) - (iv) Two coats (with any shade except white)

9.3

716

77

... More
Painting block letters or digits in black japan or any approved paint as per direction. (e) Size above 7.5 Cm and upto 10 cm.

100

1300

13

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

6.58

510

7754

... More
Add Cost of carriage of constructional material for It 14-30 @ 3%

1

7895

7895.55

... More
Add GST @ 18% ( It 13-32)

1

49112

49112.84

... More
Add LABOUR Cess @ 1% (It 13-33)

1

3219

3219.62

... More
PART D-Renovation of WTA

-

-

-

... More
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils within a lead of 75 M as directed. The item includes necessary trimming the sides of the trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1.50 M.

437.63

52196

11927

... More
Laying of P.v.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, ee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge. 140 mm dia

600

6084

10.14

... More
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.

28.17

9127

324

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety

2.82

15649

5555.22

... More
Brick work with first class bricks in cement mortar (1:6) (a) In foundation & plinth

8.12

39964

4919.88

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

8.1

5462

674.33

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

361.21

28008

7754

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams,columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). b) 25 mm to 30 mm thick wooden shuttering as per decision and direction of E.I.C

9.18

3011

328

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (c) 15 mm thick plaster

101.31

14333

141.48

... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

101.31

3314

32.72

... More
Removing of chokage due to sludge, mud, sand or any other forign materials deposition from the under ground 450/ 300/ 225/ 150 mm dia. RCC pipe line with split bamboo, wire brush, coir rope etc. along with suitable cleaning agent as necessary as per direction of Engineer-in-charge. ( This item includes the cost of earth cutting and back filling of trenches and required materials for chokage cleaning but excluding the cost for taking out 1 full length of RCC Pipe by dismantling 2 nos Collars and refitting the RCC Pipe with new two nos collar).

-

-

-

... More
225 mm RCC Pipe Line

300

11598

38.66

... More
Repairing of leakages in collar joints of R.C.C. Pipe line by opening the joints fully by chipping out the old morter, cleaning the pipe recesses and collar properly, and thereafter positioning and levelling the pipes and collar, filling the annual spaces of joints with jute braiding dipped in cement slurry and grouting with (1:2) cement morter mixed with approved quality water proofing compound (5% by wt. of cement) and curing all complete as per direction of Engineer-in-Charge.

-

-

-

... More
225 mm RCC Pipe Line

10

678

67.89

... More
150 mm RCC Pipe Line

30

1470

49.03

... More
Taking out the damaged R.C.C. Pipe and two collars by dismantling two joints carefully, carrying and stacking the same near the pump house, carrying new pipe and collars from the field stack, lowering the same within the trench, properly positioning and levelling on bricks laid flat, between collar and the pipe joints with jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved quality water proofing compound (5% by weight of cement) and curing all complete as per direction of Engineer-in-Charge.

-

-

-

... More
225 mm RCC Pipe Line

10

1159

115.98

... More
150 mm RCC Pipe Line

15

1301

86.75

... More
Taking out the condemmed 150 mm dia. NTP/Alfa-Alfa valve from 150 mm dia MS/GI pipe of existing spout chamber by carefully chiseling with least disturbance to the existing system of structure upto required limit and fitting, fixing of new one with 150 mm dia MS/GI pipe in proper position of the spout chamber using havoc zink jute so as to make the joint leak proff including mending good all damages and returning back the condemmed materials at store as per direction of Engineer-in-charge.

11

891

81.09

... More
Jointing the end of 300 mm / 200 mm / 150 mm dia MS Special bend from surge tank/ shore manifold with under ground RCC pipe lines of 450 mm/ 300 mm / 225 mm dia by jamming with cement concrete (1:2:4) with 10 mm down stone chips mixed with approved water proofing compound of adequete thickness to provide a leak proof joint including carrying the special bend from departmental store to site, curing etc. as per direction of Engineer-in-charge.

3

251

83.92

... More
Fitting and fixing of MS/GI/CI accessories and special in pipe line (accessories and special to be supplied departmentally) including supply of jointing materials viz. rubber insertion, nuts and bolts, havoc zink complete as per direction of Engineer-in-charge.

-

-

-

... More
300 mm/ 200 mm/ 150 mm dia MS Special Bend

3

147

49.03

... More
150 mm dia CI Sluice Valve

4

218

54.69

... More
150 mm dia Alfa-Alfa Valve

12

656

54.69

... More
Installation/ Erection of Surge Tank / Shore manifold ( to be supplied from Deptt. Free of cost) over a rigid base of cement concrete (1:2:4) with stone chips 20 mm. down of 1250x1250x150mm. Over a single layer of brick flat soling and embedding the legs of the surge tank/ shore manifold within the concete base including cost of all materials and labour and as per direction of Engineer-in-charge.

1

2263

2263.08

... More
Jointing the end of 150 mm. dia. M.S. extension pipe for spout chamber with 150mm. end of R.C.C. Tee including carrying the M.S. extension pipe from store to site, levelling and positioning the end of extension pipe concentrically with 150mm. end of R.C.C. Tee on bricks laid flat within the field trench and jamming the joints with cement concrete (1:2:4) with stone chips 10 mm. down mixed with approved water proofing compound 5% by weight if cement) of adequate thickness to provide a leak proof joint as per direction of Enginer-in-Charge (Cost of bricks for levelling is included).

11

891

81.09

... More
Dismantling the existing GI/MS delivery pipe line connection between the existing D /Surge tank / Tripod set / Tube Well assembly viz Sluice Valve , bend, Surge Tank/ Distribution Chamber /Tripod Set, Connection Pipe etc. and disconnection of delivery side viz special bend etc all complete as per direction of the E.I.C and stacking all serviceable materials at site.

1

752

752.47

... More
Patch/Doubling works complete with 5 mm M.S. plate including welding, gas cutting, fitting, fixing complete a) Cost of 5 mm MS plate including wastage due to cutting labour charges for straightening fitting, fixing in position.

-

-

-

... More
(b) Gas cutting to required size of 5 mm thick M.S. plate, N.S.C. channel etc. including labour charges, hire charges for all tools and plants.

4

743

185.76

... More
Welding in MS Structural work with Gas or Electric

900

8100

9

... More
Extra rate allowed for It no 38-41 and It No 43-45 and It No 52 and It No 55-56 @ 3% for the district Dakshin Dinajpur

1

3059

3059.03

... More
Add GST @ 18% ( It 36-57)

1

38040

38040.18

... More
Add Cess @ 1% (It 36-58)

1

2493

2493.75

... More
PART E- Electrical wiring and Installation of Pump Motor Set

-

-

-

... More
Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall ( including all materials except equipment ) i) For 100 Amp. Main Switch

1

215

215

... More
Fitting & fixing of Starter (Direct on Line or Star-Delta/Auto-Transformer) with Nuts & Bolts fixed on Angle iron frame on wall and making necessary connection with the electrical cables iii) Star-Delta 1Auto-Transformer Starter (Above 15 HP upto 25 HP)

1

240

240.45

... More
Fixing only Voltmeter/Ammeter/Energy meter with screws & other fixing materials incl. making necessary holes and connections

-

-

-

... More
a) Ammmeter

1

57

57

... More
b) Voltmeter

1

57

57

... More
Meter loop connection with 1.1 K.v. Gr. 31/2 core /4 core 10 Sqmm to 50 Sq mm. p.v.C./ XLPE insulated & sheathed and armoured Aluminium/Copper Cable from Meter to incomming TPN Main Switch /Terminal b) For HDTW/MDTW/MINI RLI Scheme i) 25 Sqmm 31/2 core Core Aluminium Cable

1.5

495

330.03

... More
Supplying & fitting 20 mm × 30 cm( 8"x 12") . E.I. danger board on wall.

2

170

85

... More
Supplying and fixing 240 volt, 15/16 Amps. DP. Sheet Steel Main Switch on flat iron frame on wall. (Havells make.)

1

576

576

... More
Earthing with 65 mm. dia G.I. pipe ( TATA medium) into 3.0 mts . Long and 1 no 50mmx6mm galvanized ( hot deep) steel strip ( 4 metre long) , 20mm dia x125mm long galvized bolt , double nuts double washers including finishing both ends by making holes etc. and S& F 65 mm dia G.I. pipe ( ISI medium) protection ( 3mts long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 mts. (a) For soft soil

1

3868

3868

... More
Supplying and fixing earth bushbar of galvanized (Hot Dip) M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes on the busbar complete with G.I. bolts, nuts, washers etc. , spacing insulators as required .

0.3

46

156

... More
Connecting the equipments to earth busbar including supplying and fixing G.I. (Hot Deep) Wire of size as below on wall/floor with stapples burried inside wall and floor as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good damages. ( a) 6 SWG

10

130

13

... More
Transportation of Submersible Electro Motor Pumping set,column pipe,sluice valve,bend,kiox box,short piece etc. along with all other accessories and equipments over Pucca/Kancha Road from Sub-Divisional Store to worksite including loading at the lifting point and unloading at the delivery point including necessary head load upto 100 metre at both ends.

1

2945

2945.78

... More
Instalation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.) (a) 100/150/200 cubic metre her hour capacity electro motor pumping set. (i) Length of pump assembly of any length exceeding 18 metre length.

1

1510

1510.61

... More
Charges for jointing water proof cable with required water proof insulation and proper jointing compound including supply of other related materials, complete in all respect.

3

127

42.43

... More
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex (wall matching color) top cover of 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] (a) average run 1.5 mtr.

1

268

268

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] (a) average run 5 mtrs. Pump Room - 1 light point, Varandah - 1 light point

2

1154

577

... More
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.

2

76

38

... More
Plain and finished timber planks in partition, shelves etc. fitted and fixed complete as per design (butt joints) in ground floor. (iii) 25mm thick planks (c) other Local wood [Wooden Board in size-900 mm x 1200 mm]

1.08

739

685

... More
Supplying and fixing medium gauge G.I. Pipe (ISI-Medium) protection with necessary fittings and jointing materials. a) 25 mm dia. (G.I. Pipe for passing cable)

3

519

173

... More
Add extra charge @ 7.0 % on PWD (E) items for Dakshin Dinajpur District ( It 65-69 and It 73-75 and It 77)

1

476

476.55

... More
Add GST @ 18% ( It 61-78)

1

2461

2461.02

... More
Add Cess @ 1% (It 61-79)

1

161

161.33



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.